Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC KILA ROAD 00 00 00 NARNAUL HARYANA 123001 | MAHENDRAGARH | HARYANA | 123001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹46.6 L+₹3.8 L (8.95%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹47.2 L+₹4.4 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.1 L+₹6.3 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
21 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HISAR
HQ CWE HISAR HISAR MIL STATION - 125006
PROVN OF EXTRA HIGH TENSION AUTOMATIC VOLTAGE REGULATOR SYS AT MAIN RECEIVING STN AT HISAR MIL STN UNDER GE HISAR
2022_MES_503069_1
CWE/HSR-32 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE HISAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE HISAR
₹88,000
25 Feb 2022
21 Jan 2022
23 Feb 2022
21 Jan 2022
21 Feb 2022
7 Feb 2022
60 days
Amount
Supplying, laying jointing testing and commissioning of HT underground XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11KV grade (Earthed) of size 185 sqmm 3 core confirming to IS-7098 Pt-II cable laid in trenches/walls/ducts/poles etc. complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil etc complete all as specified and as directed.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed. .
Returning filling in incl spreading levelling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
Supplying and laying reinforced precast concrete cable cover class HV type 1 flat size 300mm x 180mm x 40mm (ISI Marked) complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for in door termination, cold shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 185 sqmm
M&L for providing 100mm PCC platform on top of brick masonry of Size 6x3 mtrs (outer dimensions) and 1.2 mtr high from ground level and 0.5 mtr below ground level for placing RMU, chain-link fencing around the platform fixed to angle iron post 1.8 mtr high using angle iron of size 40mm x 40mm x 6mm and 1.00m away from platform with entry gate and steps and applying a coat of black bituminous paint over a coat of red oxide primer on the steel surfaces complete all as specified and directed including provision as under :- (i) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation of brick wall and fencing post including excavation in earthwork, return filling in and removal of surplus soil. (ii) Brick work with fly ash brick in CM 1:6 including 15mm thick plastering in CM 1:4 over exposed surfaces. (iii) 100mm thick hard core using brick bats of grade n.exc 63mm. (iv) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base. (v) 100mm thick PCC (1:2:4) type D-2 (using 20mm graded stone aggregate) as in flooring finished even and fair. (vi) Two coats of cement base paint over a coat of cement primer over plastered surfaces complete. (vii) Chain link MS galvanised fencing of mesh size 75mm x 75mm and dia of wire 3mm complete.
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth iron strip 24x4mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe medium grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20 mm dia bore for watering funnel with wire mesh. RCC cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion
MAHI PALL CONSTRUCTION COMPANY
fauji electric works
S K CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .