| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹26.1 L+₹1.5 L (5.93%)Rejected-Finance | L2 | Rejected-Finance Not being Lowest | |
| 3 | L3₹27.5 L+₹2.8 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Not being Lowest |
Tender Value
₹24.7 L
EMD Value
₹49,400
Closing Date
24 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME Secunderabad
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
PROVN OF CERTAIN SANCTIONED WORKS UNDER GE MCEME SECUNDERABAD
2020_MES_391092_1
GE/MCEME/19 A OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
Class E Category a(I)
6 documents required · 6 mandatory
₹500
GE MCEME Secunderabad
₹49,400
Yes
18 Dec 2020
29 Oct 2020
26 Nov 2020
29 Oct 2020
24 Nov 2020
11 Nov 2020
60 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard soil/dens soil complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in mass concrete and foundation complete all as specified and directed.
M&L for Stone Masonry Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point in soils complete all as specified and directed.
M&L for brickwork with fly ash bricks old sized, straight or curved on plan exc 6 m mean redius built in cement mortar 1:4 complete all as specified and directed.
M&L for Cement concrete cast-in situ 1:2:4 type B1 using 20mm graded aggregate as in lintels up to 1.5m clear span, cills steps: seimic and other similar bands, plinth courses, string scourses, lacing courses, perapets and railings upto 60cm in height, copings, kneerlers, apex stones, bed plates, kerbs not provided water troughs and thelike including wethering, slightly rounded or chamfred angles and throating as directed (the rate include use of farm work and reinforcement shall be measured separately) complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for 15mm thick in CM 1:4 rendering on brick or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:6 on brick or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of wall surfaces and applying three coats of white wash on wall surfaces complete all as specified and directed.
M&L for two coats of cement based paint over a coat of cement primer on newly plastered surfaces of walls including preperation complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in sub base complete all as specified and directed.
M&L for 20mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 complete all as specified and directed.
S&F PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs complete all as specified and directed.
Complete removal of wall finishes of wall surfaces and applying two coats of OBD on internal wall surfaces on 3mm thick wall care putty & after preparation Priming plastered and other surfaces with alkaliresistant priming paint complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S&F Tubes, 'Medium grade’ galvanised, with all fittings and fixed comp to walls and ceilings or laid in floors of 15mm bore complete all as specified and directed.
S&F Tubes, 'Medium grade’ galvanised, with all fittings and fixed comp to walls and ceilings or laid in floors of 20mm borecomplete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20mm bore complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection/paths etc finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for Hard core of guage n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F of PVC (SWR) bend any radius of bore 110mm complete all as specified and directed.
M&L salt glazed stone wave gully traps square or rounded mouthed type & fix 150x150mm fixed in cement concrete complete all as specified and directed.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregate as in pre-cast cover slabs for manholes incl necessary form work set in CM 1:4 all as specified. (Reinforcement will be measured & paid separately) complete all as specified and directed.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregated) set in CM 1:4 as in benching to manholes/ SEPTIC CHAMBER complete all as specified and directed.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregated) as in copping incl necessary form work complete all as specified and directed.
S&F PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc complete all as specified and directed.
S&F solid PVC Panel Door shutter 30mm thick style consisting of Frame made out of M.S Tube for top & Bottom rails, MS Frame shall be covered with heat moulded, Plain colour PVC ’C’ channel having a PVC Sheets strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for Top rail, lock rail bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour 5mm thick PVC sheet fitted in the MS Frame, welded/ sealed to stiles and rail with suitable PVC sheet beading and jointed together with solvent cement all as per manufacture instruction complete all as specified and directed.
S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F 200mm length of aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm length of extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 etc complete all as spd and directed.
M&L for fixed with screws 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc completed all as specified.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces width or girth exc 10cm including preperation of surfaces complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L glazed ceramic tiles in dado surfaces 300x200x7mm thick over 10mm thick rendering in CM 1:4 to receive tiles set and joint in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
M&L screeding bed or bedding layer 15mm thick CM 1:6 for laying floor finishes complete all as specified and directed.
Demolition of brick work or stone masonry, built in cement mortar complete all as specified and directed.
M&L brick work with Sub Class B bricks old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
Taking down of cement plaster on brick or stone walls,/ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L Rendering 10mm thick in CM 1:3 on brick work or concrete surface on ceiling, inclusding chiken wire mesh fixing to existing slab steel complete finished even and smooth without using extra cement complete all as specified and directed. Note: Scaffolding is included in qouted rate
M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surface on wall, finished even and smooth without using extra cement complete all as specified and directed.
S&F wash hand basin Vitreous china white flat back size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets in repairs complete all as specified and directed.
S&F Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc., Bore of pipes in 32mm, etc complete all as spd and directed.
S&F 15mm dia Pillar taps fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F 15mm bore Bib taps fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F Low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ cm2 laid in trenches, Bore of pipes in 32mm, etc completed all as spd and directed.
S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F 15mm dia brass Stop valves screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed 15mmbore complete all as specified and directed.
S&F Vitreous china Urinal bowl flat back size of 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
Complete removal of existing treatment on walls and applying two coats of cement base paint over one coat of alkali resistantprimer compelete all as directed.
M&L for poly carbonate sheet of 4-5mm thick, fixed at roof top with necessary arrangement comlete all as specified and directed.
M&L for RCC 1:1.5:3 type A1 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in bed block i/coping ncluding form work complete all as specifed and directed.
S&F Framed work with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, etc complete all as spd and directed.
M&L priming plastered roof surfaces with bituminous primer @ 0.3 Kg/sqm as per IS-3384 and providing water proofing treatment by applying mineral finish 3.5 Kg/sqm actatic poly propylene (advanced App torch membrane with fiber glass and finished on top with fiber glass mineral states torch incistern of thickness 3mm by torch bonding complete over and providing necessary slope using WPC @ 3% or as per manufacturer instructions after taking down carefully cement/ cement lime plaster of any thickness of roof incl existing tar felt of any thickness and preparing the surfaces by cleaning of foreign matter by wire brushing roughing surface to receive plastered and scrubbing down with water (IWPC and plaster will be measured and paid separately) complete all as specified and directed.
Supply only WPC complete all as specified and directed.
M&L for coloured tiles, Non-skid Ceramic tiles 7 to 8mm thick area of each tile exc 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.
Cutting holes into or through brick walls/concrete surface built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, superficial area n exc 150 sq cm each complete all as specified and directed.
S&F Vitreous china Squatting pan Orissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding & 'P' traps as required in repairs
Excavating in post holes (or similar holes) each n. exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, soft/ loose soil etc, complete all as specified and directed.
M&L PCC 1:3:6 type C2 (using 40mm graded agg) as in foundation filling and mass concrete etc complete all as spd and directed.
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified etc completed all as specified.
Complete removal of wall finishes of ceiling surfaces and applying two coats of OBD on concrete surfaces/ wall surfaces on wall care putty & after preparation Priming plastered and other surfaces with alkaliresistant priming paint complete all as specifed and directed..
Excavation in trenches n.exc 1.50m wide and n.exc. 1.50m depth and getting out in soft/ loose soil complete all as specified and directed.
S&F for PVC (SWR) vent cowl, bore of pipe in 110mm, etc complete all as specifed and directed.
M&L salt glazed stone ware drain pipes 150mm dia bore (Grade 'A' pipe) laid in trenches and jointed as specified incl demolition complete all as specified and directed.
M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 100 mm dia SWG pipe/pvc PIPE 110 mm dia complete all as specified and directed.
All as per item above but 150 mm dia SWG pipe complete all as specified and directed.
M&L 110mm bore PVC (SWR) bend with oval access doors, incl taking down complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out hard / dense soil complete all as specified and directed.
Excavation over areas & depth not exceeding 1.5 M deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas & depth exceeding 1.5 M and not exceeding 3 M deep and getting out inhard / dense soil complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B1 (using 20 mm graded granite stone aggregate) in floorings including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves incl supports etc for rough finished surface of concrete complete all as specified and directed.
M&L for reinforced cement concrete (Nominal mix) type B1 1:2:4 (20 mm graded aggregate) in lintel bands, roof beams and cantilevers etc complete all as specified and directed.
-Ditto- as per Item no. 59 herein before but 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius as half brick wall built in CM 1:4 complete all as specified and directed.
M & L for plain Cement Concrete Type C1 1:3:6 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded complete all as specified and directed.
S & F for rungs, bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, hains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, AC Sheets any guage, thickness including Nainital or similar pattern roof covering/wall cladding complete all as specified and directed. Note : Height of the bldg truss is upto 6 mtr) complete all as specified and directed.
S&F 0.50mm thick pre painted galvalume sheet aluminium zinc coating GI based plain sheet sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating by manufactureres instruction complete all as specified and directed.
Dismantling of steel work of any description and in any position not otherwise specifically provided for complete all as specified and directed.
S&F Rolled mild steel in joist, channel angle or tee section, flat iron fixed independently quality conforming to Fe 410W (Gde-250) complete all as specified and directed.
M&L for two coat of oil bound distemper on newely plasted surfaces of walls including prepration of surfaces complete all as specified and directed.
S&F Anodised aluminium frame for doors, partitions, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified and directed
supply only sheet glass 5.5 mm thick ordinary quality of size as directedby Engr -in- charge complete shall as specified and directed
M&L for 18mm thick, Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, etc complete shall as specified and directed
M&L for preparation of old decorated surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying two coat of cement base paint complete all as specified.
M&L for reinforced Cement Concrete 1:2:4 20 mm graded aggregate nominal mix for slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like complete all as specified and directed.
S&F GI 5mm dia bars/wire for hanging/drying cloths, cut to length, bent to shape required including cranking bending hooks ends and binding with Mild Steel wire(annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
M&L for coloured tiles, Non-skid Ceramic tiles 7 to 8mm thick ( square or rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.
M&L for preparation of exsiting surfaces of walls and and applying Two coat of oil emulsion distemper (OBD) complete shall as specified and directed
Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
M & L for Point wiring on surface conduit with 1.5 Sq mm copper conductor single core PVC insulated unsheathed 1100 V grade multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 2 mm thick MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for: (a) One light point controlled by one, one way switch 5 A, SP
(b) One ceiling fan/exhaust fan point controlled by one, one way switch
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on same board.
Description all as per item No 100 here-in-before but using 2.5 Sq mm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 5/15 Amps switch socket combination point including running of 2.5 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed.
S & F Switch piano type single pole one way flush type 5 Amps capacity 230 volts complete all as specified and directed.
S & F switch socket combination 2/1 multipurpose 5 Amps flush type, 230 Volts complete all as specified and directed.
S & F switch socket combination 2/1 multipurpose 3/5 pin 5/15 Amps flush type, 230 Volts complete all as specified and directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed.
S & F lamp holder insulated body with back plate for angle/batten fittings fixed with round blocks complete all as specified and directed.
Supply and fix stepped type electronic ceiling fan regulator AC 230 Volts suitable for 1200 / 1400 mm sweep complete all as specified and directed.
S and F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 Volts double door complete all as specified and directed.
Supply & Fix MCB SPN 230 volts 'C' series suitable for fixing on MCB DB's of capacity 32 Amps complete all as specified and directed.
Supply & Fix MCB SP 240 volts suitable for fixing on MCB DB's of capacity 5 to 32 Amps complete all as specified and directed.
Supply and fix sheet metal enclosure vertical MCCB DB TPN 4 Way with 200 Amps rated bus bar 415 volts suitable for and including 125 amps TP MCCB 16 KA as incommer complete all as specified and directed. Note : MCB SP shall be measured and paid seperately.
Supply & Fixing LED tube light fitting retro type single tube 1x18/20watts 230 volts complete with all accessories , prewired fixed to wall/ceiling with 2 Nos PVC round blocks with necessary hanging/fixing arrangements & connecting to the point wiring with necessary flexible copper conductor of multisranded of suitable size and length from fitting to the ceiling rose in and including tube rod 20 W complete all as specified and directed.. Make Havells/CG/Philips/Jaguar
M & L for Submain wiring on Surface with two single core 6 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing complete all as specified and directed. Note :- Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Supply & fix LED energy efficient security light fitting of capacity of 20w with suitable dia GI pipe bracket for fixing the light on wall all as directed. Make : Havells Endura Pearl 20watt/philips/Bajaj. NOTE : quoted rate included the suitble GI pipe bracket,nuts and bolts complete all as specified and directed.
S & fixing the light grade GI tubing of 40 mm dia for protection of the cable all as specified as directed by Engineer-In-Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead 4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 15mm bore from earth elelctrode to DBs/main switch incl provn of concrete pit in PCC , GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4mm size and protection pipe of 25mm bore GI light grade complete all as specified and directed.
M & L for Submain wiring on surface with four single core 6 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 32 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing complete all as specified and directed.. Note :- Four runs of 6 Sqmm cable, one run of 6 Sqmm earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Supply & lay ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing ccomplete all as specified and directed.of size 3.5CX35 Sqmm
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid complete all as specified and directed.
S& Lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm complete all as specified and directed.
S & F ultra modern recess mountingLED luminaire of 42 W,6500 k suitable for armstrong/grid/pop ceiling of 2'x2' complete with electronic driver LEDs complete all as specified and directed.. Make Havells :PLUTONEO2X2PLR42WLED857 or equivalent in CG/Bajaj
Supply and fix 32 Amps TP MCB metallic Plug &Socket complete all as specified and directed.
S&F sheet metal enclosure with 2 pole and Earth Metal Plug & Socket including 20A SP MCB complete all as specified and directed.
S & F TP MCB of capacity 32amps operated at 415 volts C series all as specified and directed
Disconnecting and taking down and refixing the same ceiling fan /Exhaust fan of any sweep from any height, overhauling, including painting of ceiling fan/ exhaust fan complete all as specified and as directed.
NEWS CONSTRUCTIONS
VACON INFRASTRUCTURES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .