| 1 | L1₹15 LAccepted-Finance 4 KRUSHNANJALI BLDG TAI PINGALE CHOWK NEAR SARVESH HALL DOMBIVLI EAST 421201 | DOMBIVLI | THANE | MAHARASHTRA | 421201 | L1 | Accepted-Finance As per G schedule |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
28 Sept 2026, 9:00 amClosed
PARSHASAK
gram panchayt panchoo
SENGAL DHORA KEPASS TUBEWELLNIRMAN AND COMMISSIONING KA KARY GRAM PANCHAYAT PANCHOO
2026_PRD_598488_1
20
Open Tender
Miscellaneous Works
Percentage
panchoo
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
gram panchayat panchoo , MD RISL
₹30,000
Yes
28 Sept 2026
17 Sept 2026
28 Sept 2026
17 Sept 2026
28 Sept 2026
17 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Tube Well from ground level and up to 100 mtr. depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe.Nominal bore 200 mm dia. | 350 | MTR | 1,104.3 | ₹3,86,505 |
| 2 | Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and up to 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. | 250 | MTR | 165.65 | ₹41,412.5 |
| 3 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes 200 mm dia NB (Thickness of pipe 5.4 mm & mass of tube 28.46 Kg/m) | 259 | MTR | 2,460.6 | ₹6,37,295.4 |
| 4 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 200 mm dia nominal bore of 5.4 mm thickness | 12 | MTR | 285.3 | ₹3,423.6 |
| 5 | Supply & Installation of 3 phase ISI marked submersible motor pump set of five star (if not available then three/ four star whichever higher rating available) rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.15 KW (20 HP) and above, head above 120 mtr. | 15 | KW | 5,688 | ₹85,320 |
| 6 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. Above 15 HP | 1 | EACH | 28,905.3 | ₹28,905.3 |
| 7 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 6.0 Sq.mm | 530 | MTR | 254.7 | ₹1,34,991 |
| 8 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. | 1 | EACH | 626.4 | ₹626.4 |
| 9 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 mm dia | 1 | EACH | 887.4 | ₹887.4 |
| 10 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 65 mm dia | 259 | MTR | 688.5 | ₹1,78,321.5 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tendernotice_2.pdf
PDF • 7.90 MB
BOQ_1061003.xls
BOQ • 0.29 MB
corrigendumm.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .