Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.2 L+₹1.7 L (14.8%)Rejected-Finance MISRA ELECTROSTATE CENTRE BAR ASSOCIATION COMPOUND CIVIL COURT AYODHYA 224123 UP | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹14.5 L+₹3.0 L (25.6%)Rejected-Finance 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹14.8 L+₹3.2 L (28.2%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹15.9 L+₹4.4 L (38.4%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Mar 2023, 6:00 pmClosed
GE (MES) Ayodhya
Garrison Engineer Military Engineer Services Ayodhya
REPAIR MAINT OF LT OVERHEAD LINES, LT POLES, INSULATORS, LT PANELS, MCCBS, ACBS, PAINTING TO POLES AND LT PANELS WITH ALLIED WORKS AT AYODHYA CANTT UNDER GE AYODHYA
2023_MES_581673_1
8358/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Ayodhya
₹50,000
Yes
12 Apr 2023
17 Feb 2023
20 Mar 2023
18 Feb 2023
17 Mar 2023
4 Mar 2023
Amount
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Removing excavated materials (soil) n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness shall only be measured & Paid.
Supply & Laying old size sub class 'B' bricks locally available best quality, laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
Hiring of cable fault detector to detect exact position of fault for XLPE /PVC LT/HT cable, 1100/11000 Volts grade, heavy duty aluminium conductor of any size including to and fro transportation charges etc complete all as specified and directed by Engr-in-Charge.
S&F straight through cable jointing kit for 16 Sqmm 4 core LT U/G cable of following sizes complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 7.00 here-in-before but for 25 to 50 Sqmm 3.5 Core
All as per Srl item No. 7.00 here-in-before but for 70 to 150 Sqmm 3.5 Core
All as per Srl item No. 7.00 here-in-before but for 185 to 240 Sqmm 3.5 Core
All as per Srl item No. 7.00 here-in-before but for 300 to 400 Sqmm 3.5 Core
Horizontal boring in soft/loose soil under roads of any size by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed by Engr-in-Charge. Note : GI pipe shall be measured and paid for separately.
Supply & laying in replacement, 50mm dia bore steel tubing, galvanized, light grade for passing LT/HT cable under road or PCC floor or fixed on wall / pole or across the drain etc or whehrever protection of cable is required including necessary clamps, nut & bolts etc and GI fitting complete all as directed and specified.
All as per Srl item No. 13.00 above but 80mm dia bore tubing
Takingout existing unserviceable cable of any description and Supplying, laying, commissioning & testing 10 Sqmm 2 core LT underground cable 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098 (Part-I) 1998, laid in trenches, ducts, pipes or fixed on poles etc including cable gland, cable lugs, jointing, supporting clamp etc of the under mentioned type and sizes complete all as specified and directed by Engr-in-Charge :-
All as per Srl item No. 15.00 here-in-before but 16.00 Sqmm 4 core
All as per Srl item No. 15.00 here-in-before but 25.00 Sqmm 3.5 core
All as per Srl item No. 15.00 here-in-before but 50.00 Sqmm 3.5 core
All as per Srl item No. 15.00 here-in-before but 70.00 Sqmm 3.5 core
All as per Srl item No. 15.00 here-in-before but 95.00 Sqmm 3.5 core
All as per Srl item No. 15.00 here-in-before but 120.00 Sqmm 3.5 core
S&F in repair, aluminium sector lugs short barrel of 25 Sqmm sizes complete all as specified and directed.
S&F in repair, aluminium sector lugs short barrel of 35 Sqmm sizes complete all as specified and directed.
S&F in repair, aluminium sector lugs short barrel of 50 Sqmm sizes complete all as specified and directed.
S&F in repair, aluminium sector lugs short barrel of 70 Sqmm sizes complete all as specified and directed.
S&F in repair, aluminium sector lugs short barrel of 95 Sqmm sizes complete all as specified and directed.
S&F in repair, aluminium sector lugs short barrel of 120 Sqmm sizes complete all as specified and directed.
S&F in repair, aluminium sector lugs short barrel of 200 Sqmm sizes complete all as specified and directed.
Disconnecting electrically incomming and outgoing LT UG cable of any size from LT panel and replaced burnt/unsv aluminium bus bar of suitable size including all necessary welding work for door hinges, fixing the locking arrangement, scrapping peeled off existng paint, cleaning all inner/outer surfaces of LT Panel and applyin two coats of synthetic enamel paint over one coat of red oxide primer with spray machine / spray gun and reconnecting all incomming / outgoing cables with fixing cable gland of suitable size and aluminium lugs by using crimping tool, nut, bolt washer etc and all necesary work required for smooth functioning of LT panel complete all specified and directed by Engr-in-Charge.
M&L for installing, testing and commissioning of factry made bus bar chamber comprising of 4 Nos aluminium bus bar of 200 Amps rating, supported on insulator and enclosed with steel sheet enclosure, outdoor type, made of 3.15 mm thick CRCA sheet with top edge tappered, dust and vermin proof, having locking arrangement at front and opening arrangement from front & rear both sides including fixing arrangement on pole/gorunting in floor with colour coded FRP compression cable glands for entry & exit of cables, powder coated complete all specified and directed by Engr-in-Charge.
S&F in replacement, Indicator lamp LED type (R,Y,B) with bakelite fuse complete all as specified and directed by Engr-in-Charge.
Labour for cutting/ trimming of tree branches up to 80mm girth along the alignment of LT /HT over head electric line which are going across / touching or falling on ACSR conductor / poles or near by sub stations etc at any height from GL and making at least clearance 1.5m form conductors and removing to a distance up to 100 m where directed by Engineer-In-Charge. Note:- (i) Trimming of the branches on one sides of the conductor. (ii) Actual length of cutting will be measured. (iii) The distance as mentioned above, will be maintained during the contract period & same location subject to at least 6 months period between two trimming / leaping. (iv) Measurement will be taken including all conductor as one only.
Dismantling existing earthing of any description and M&L for new Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick, burried directly in ground vertically to a depth not less than 2.50 m below the ground level with top edge of earth plate at a depth not less than 1.50 m below ground level. Earthing plate surrounded by 15mm thick packed alternative layers of charcoal dust and common salt, connected with GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles at one end and the other end connected to main switch board and protected by 40mm dia bore medium grade GI pipe. Provision of 20mm dia bore light grade GI pipe for watering including GI funnel and wire mesh. The pipe shall be provided vertically upto top level of earthing pit and then taken horizontally to the equipment. Provisionn of cement concrete chamber of iinternal size 300x300x300mm with PCC (1:3:6 ) type C-2 (using 40 mm graded stone aggregate), constructed at 1.00 m metre away from edge of earthing pit with 50 mm thick precast RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) reinforced with 8mm dia TMT bars @ 150mm C/C including all necessary earthwork in soft / loose soil complete all as specified and shown in Electrical Plate No. 3 of SSR Part-1 (2009) and directed by Engr-in-Charge.
S&F in replacement, MCCB, 4 pole, 100 Amps, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA, lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, MCCB, 4 pole, 160 Amps, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA, lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, MCCB, 4 pole, 200 Amps, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA, lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, MCCB, 4 pole, 250 Amps, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA, lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
S&F in replacement, ACB, 4 pole, 1000 Amps, 415V 50Hz with Microprocessor based AHA-10S-CS, EDO, C - power Draw -out ACB including under voltage, rating breaking capacity 65 kA with connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- C&S Cat No. AHA10N4PMP3.1(S) or equivalent in Legrand/L&T.
Servicing/Repair the ACB of various Capacity of outdoor/indoor type, tripping circuit and resetting trip values and the nuemerical relays and checking tripping machnism fully by engaging well experienced technicians as per manufacturer's recommendations complete all as directed by the Engineer-in-Charge.
Providing services by deploying adequate number of manpower for attending day to day complaints/ breakdowns of 'NO LIGHT / SHORT CIRCUIT'' including general maintenance and cleaning and dusting of installation (SS No.2 to 26, 11 KV) and surrounding area at DRC Trg area, 17 Jak Li unit area, 5 Jak Rif Unit area, 141 Bde, 11 Jat Regt , MH Ayodhya, all MD accns ( Offrs, JCOs and ORs), All Unit Offrs mess, EME wksp, Supply depot, Nursing Offr mess of all external electric installations from feeder pillar box to building including LT overhead lines & LT under ground cable jointing, distribution panel board, security/street lights, repairs/replacement of defective componenets, fittings & fixtures and depositing the defective/unserviceable dismantled materials in store yard of AGE E/M Ayodhya complete all as directed by Enginner in Charge comprising of the following:- (a) Electrician (Skilled) for one shift per day (each shift of 08 Hrs) - 01 No. (b) Helper (Un-skilled) for one shift per day (each shift of 08 Hrs). - 02 Nos.
Note :- (i) The Electrician should have good working knowledge of HT 11 KV and LT equipments mentioned as above and ITI qualified. (ii) The Electrician should in possession of all requisite T&P as required at site. All the T&P and equipments to be provided by the contractor at his own cost and the rates shall be deemed to be included all expenses on this account. (iii) The Electrician should wear proper uniform on duty including electric shockproof shoes and the cost there of deemed to be included in the quoted rate (iv) A Penalty for absent in duty shall be Rs 750/- for Electrician and Rs 550/- for Helper per day ad Rs 50/- per day for not wearing of proper uniform (v) The timing of shifts will be 0800 to 1600 Hrs and reliever shall be arranged by the contractor and the cost thereof shall be deemed to be included in the quoted rate (vi) The contractor shall submit proof of payment through bank account, deposition of EPF and IESI/ insurance before claimimg any payment for outsourced staffs (vii) The contractor's representative will report to Engineer-in-Charge / JE EM I/C Ext Electric Supply daily in forenoon and afternoon to collect routine/urgent works related to Ext Elecctric Supply till completion of the contract. The work shall be attended by the contractor immediately. (viii) The complaint shall be rectified within 24 Hrs or otherwise a panelty of Rs 500/- per complaint per day shall be imposed to the contractor for delayed period. (ix) The contractor shall maintain Daily Attendance Register and Complaint Register duly signed by JE I/C and Engineer-in-Charge. (x) The contractor shall provide all the safety equipments to his workers at his own cost and all safety measures shall be adhered to strictly. The department shall not be held responsible for any lapse / mishappening due to lack of safety measures.
M&L for preparation of old painted steel and iron surfaces of HT electric pole 9 to11 m long in existing position and applying one coat of aluminium paint on all exposed surfaces including cross arms, brackets, junction box etc with and including marking 300mm wide strips / bands 3 Nos with post-office red & navy blue colour paint alternatively starting from top of coping, writing Pole No. with black paint in 2.5 cm high figures inside 3" dia circle complete all as directed by Engineer-in-Charge. Note : (i) All necessary safety measures shall be taken by the contractor. (ii) The cost of necessary scafolding, ladders, power lifting etc shall be deemed included in quoted rates.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
MISRA TRADING CORPORATION
M/s RAM LAKHAN GUPTA
m/s allied enterprises
Ajanta Motor Store
His And Her Enterprises
Khan Brothers
ANKIT SHIP REPAIRERS AND SUPPLIERS
Jairajyadav security services
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .