Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | ₹9.2 L | L1 | Accepted-AOC First Lowest |
| 2 | L2₹9.4 LRejected-AOC | ₹9.4 L | L2 | Rejected-AOC Second Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,700
Closing Date
4 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B AND R BR JALANDHAR CANTT
CONSTRUCTION OF ROOM, REPAIR BOUNDARY WALL VRANDA AND ROOF AT GOVERNMENT GIRLS SENIOR SECONDARY SCHOOL ABADPURA JALANDHAR (UNDER RANGLA PUNJAB SCHEME)
2026_CEPW_161982_1
Re-Bid No 50 of 24/02/2026
Open Tender
Civil Works - Buildings
90 days
JALANDHAR
Please refer Tender documents.
13 documents required · 13 mandatory
₹2,000
₹19,700
Yes
16 Apr 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
4 Mar 2026
24 Feb 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR
Name of Work :- DNIT FOR CONSTRUCTION OF ROOM, REPAIR BOUNDARY WALL VRANDA AND ROOF AT GOVERNMENT GIRLS SENIOR SECONDARY SCHOOL ABADPURA JALANDHAR ( UNDER RANGLA PUNJAB SCHEME)
Contract No: Civil Works
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
2 Dismantling of pre-stressed / RCC including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100mtr (By Mechanical Means) 3 Cum Excess(+) Full Conversion INR
3 Dismantling brick work tile, masonry or tile lining (b) In cement 4 Cum Excess(+) Full Conversion INR
4 Cridit of Old Brick 5 Each Excess(+) Full Conversion INR
5 Cridit of Old Brick Bats 6 Cum Excess(+) Full Conversion INR
6 Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base. 7 Sqm Excess(+) Full Conversion INR
7 Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. (a) Doors of area 3 sqm and below. 8 Each Excess(+) Full Conversion INR
8 Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. (b) Windows of area 3 sqm and below 9 Each Excess(+) Full Conversion INR
9 Disposal of Malba outside the premises loading/unloading including all leads as desired by Engineer-in-charge 10 Cum Excess(+) Full Conversion INR
10 Cridit of Old Doors And Windows as Fuel wood 11 Each Excess(+) Full Conversion INR
11 Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. 12 Cum Excess(+) Full Conversion INR
12 Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by manual means 13 Cum Excess(+) Full Conversion INR
13 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. 14 Cum Excess(+) Full Conversion INR
14 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. 15 Cum Excess(+) Full Conversion INR
15 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 16 0.000 Qtl Excess(+) Full Conversion INR
16 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering ) 17 Sqm Excess(+) Full Conversion INR
17 Centering and shuttering for columns (Square or ractangular or poly gonal in plain) 18 Sqm Excess(+) Full Conversion INR
18 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. 19 Sqm Excess(+) Full Conversion INR
19 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 20 Sqm Excess(+) Full Conversion INR
20 First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth 21 Cum Excess(+) Full Conversion INR
21 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level 22 Cum Excess(+) Full Conversion INR
22 12.5 mm thick cement plaster 1:5 23 Sqm Excess(+) Full Conversion INR
23 20mm thick cement plaster 1:5 in two coat work 24 Sqm Excess(+) Full Conversion INR
24 Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified 25 Rmt Excess(+) Full Conversion INR
25 Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 26 Each Excess(+) Full Conversion INR
26 Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) 27 Rmt Excess(+) Full Conversion INR
27 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. 28 Each Excess(+) Full Conversion INR
28 Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge 29 Each Excess(+) Full Conversion INR
29 Earth filling under floors with surplus ordinary soil or soil containing gravel or premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres 30 Cum Excess(+) Full Conversion INR
30 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 31 Cum Excess(+) Full Conversion INR
31 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material 32 Sqm Excess(+) Full Conversion INR
32 Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. a Size 600x600 mm 33 Sqm Excess(+) Full Conversion INR
33 Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. a Size 600x600 mm. 34 Sqm Excess(+) Full Conversion INR
34 Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete (c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. 35 Metre Excess(+) Full Conversion INR
35 Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) 36 Kg Excess(+) Full Conversion INR
36 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 37 Qtl. Excess(+) Full Conversion INR
37 Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make (b) Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area 38 Sqm Excess(+) Full Conversion INR
38 Factory manufactured solid flush door fixed in position iron hinges, etc . (excluding the cost of any fittings other than specified above but including the labour for fxing the same in position a) comercial with elm or gujan facing on both/sides with laminated core and lipped edges. iv) 35mm thick. 39 Sqm Excess(+) Full Conversion INR
39 Providing & Fixing decorative laminated sheet 0.72mm thick and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 40 Sqm Excess(+) Full Conversion INR
40 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) ii) For shutter area above 0.50 sqm 41 Sqm Excess(+) Full Conversion INR
41 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 42 Sqm Excess(+) Full Conversion INR
42 Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) 43 Sqm Excess(+) Full Conversion INR
43 Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm 44 Sqm Excess(+) Full Conversion INR
44 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade 45 Sqm Excess(+) Full Conversion INR
45 Providing and fixing mineral fibre false ceiling tiles at height upto 4 mtr. of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. i With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm 46 Sqm Excess(+) Full Conversion INR
46 ELECTRICAL WORK 47
47 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: 48
48 Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 49
49 Wiring fan point (With fan box) 50 Each Excess(+) Full Conversion INR
50 Wiring light point 51 Each Excess(+) Full Conversion INR
51 Wiring 6Amp. wall socket point 52 Each Excess(+) Full Conversion INR
52 Wiring 6Amp. Plug control comprising wall socket point 53 Each Excess(+) Full Conversion INR
53 Wiring 16/20Amp. power plug control point 54 Each Excess(+) Full Conversion INR
54 RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): 55
55 Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 56
56 Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 57 Each Excess(+) Full Conversion INR
57 PVC INSULATED FR COPPER CONDUCTOR CABLES: 58
58 Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 59
59 Overall size 1.5sq.mm (Un-sheathed) 60 P.Mtr Excess(+) Full Conversion INR
60 Overall size 2.5sq.mm (Un-sheathed) 61 P.Mtr Excess(+) Full Conversion INR
61 Overall size 4sq.mm (Un-sheathed) 62 P.Mtr Excess(+) Full Conversion INR
62 XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): 63
63 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 64
64 Overall size 16sq.mm (2Core) Un-armoured (On-Surface) 65 P.Mtr Excess(+) Full Conversion INR
65 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: 66
66 Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 67
67 Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 68 P.Mtr Excess(+) Full Conversion INR
68 G.I. EARTHING: 69
69 Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). 70
70 Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14Metre in length) 71 Each Excess(+) Full Conversion INR
71 G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- 72
72 Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) 73 P.mtr Excess(+) Full Conversion INR
73 MINIATURE CIRCUIT BREAKERS: 74
74 Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 75
75 MCB Single Pole 6-32amp. (10kA, Curve-C) 76 Each Excess(+) Full Conversion INR
76 MCB Double Pole 50, 63amp. (10kA, Curve-C) 77 Each Excess(+) Full Conversion INR
77 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: 78
78 Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- 79
79 SP&N Double Door Distribution Board 8 way each 80 Each Excess(+) Full Conversion INR
80 Supply and erection of AC Ceiling Fan 1200mm (48")-3star suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. 81 Each Excess(+) Full Conversion INR
81 Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %. complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab. 82 Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_328177.pdf
techsummary_328177.pdf
finance_328177.pdf
BOQ Comparative Chart
xlsx
finsummary_328177.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
BOQ_328177.xls
BOQ • 0.36 MB
Technical_Conditions.pdf
Tender Documents • 0.56 MB
SBD.pdf
Tender Documents • 3.81 MB
Download all tender documents and submit your bid