| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹29.3 L+₹1.6 L (5.94%)Rejected-AOC 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹32.2 L+₹4.5 L (16.4%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical No, Slow Progress, show cause notice issued QE Mar 2024 Srl No 195 of CEPZ dt 29 May 2024 |
Tender Value
₹49.8 L
EMD Value
₹1 L
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(North) Akhnoor
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
PROVN OF 12 X STEEL TUBULAR POLES ALONGWITH PERIMETER LIGHTS AT 638 SATA BTY INCLUDING SPL REPAIR OF REPLACEMENT OF HIGH BAY LAM WITH HIGH PRESSURE SODIUM VAPOR BULBS TO LUMINOUS LIGHTS OF EQUAL WATTAGE IN BOTH HANGARS OF 257 ARMY AVN SQN AT TANDA AV
2024_MES_665112_1
CA NO- GE(N)/AKH-24/2024-2025
Open Tender
Job Works
Item Rate
180 days
Akhnoor
Class D Cat b i
8 documents required · 8 mandatory
₹500
GE (North) Akhnoor
₹1 L
Yes
22 Nov 2024
10 Jul 2024
11 Sept 2024
10 Jul 2024
4 Sept 2024
24 Jul 2024
Amount
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells/KEI/ Gloster/ Polycab
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 10 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells/KEI/ Gloster/ Polycab
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells, KEI, Gloster, Polycab.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 16 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells, KEI, Gloster, Polycab.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 25 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells, KEI, Gloster, Polycab.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells, KEI, Gloster, Polycab.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 70 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells, KEI, Gloster, Polycab.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells, KEI, Gloster, Polycab.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 120 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells, KEI, Gloster, Polycab.
M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10/16sqmm x 2/4 core cables including testing complete all as specified and as directed.
M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 25 to 50 sqmm x 3.5 core cables including testing complete all as specified and as directed.
M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 70 to 150 sqmm x 3.5 core cables including testing complete all as specified and as directed.
Steel tubular swaged pole type 410 SP-31 (9 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, final taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5m from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5m from ground level/coping and also write the pole No on the surface of pole, complete all as specified and directed.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation of pole,laying of pipe line and getting out in any type of soil complete all as specified and directed.
Description all as per srl item No 14 but beyond 1.5m depth but nexc 3.0m depth
Returining filling in including spreading, levelling, watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Protection to cable with one layer of brick laid flat across the cable using all size sub class 'B' Bricks, complete all as specified and directed .
Sand cushioning to under ground cable, 8 cms thick before laying the cable and 15 cms thick after laying and stretching the cable in trenches including hand punning and consolidating, punned to 18cm thickness, complete all as specified and directed. Note : For payment purpose, only punned thickness shall be measured.
Supply, fabrication and fixing LT feeder pillar box of size 500x450x500mm made out of MS sheet of 3.15mm thick bent to shape & size factory made with welding, bending works suitable for and including 200 Amps rated aluminium bus bar (length of bus bar not less than 40 cm) 4 Nos, making holes of any size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and lenght of angle iron not less than 1 mtr, 0.5 mtr to be embedded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping, from one of the makes as specified in the List of makes enclosed at Appx 'A' complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45cm x 45cm x 45 cm,RCC cover 1:2:4 type B1 of size 45x45x6 cm, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. Note:- The required resistance of Earthing shall be less than 3 ohm, If not found to the required resistance, the contractor has to do re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
S & F , installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer shall share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of panel SHALL submit a copy of ASTA CPRI TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960°C in accordance with 60695-2-11 [flame retardant and self-extinguishing. Make- Hensel/Schneider/ABB/Rittal/Siemens
Incomer i. Main MCCB 125A 4Pole Breaking Capacity 18KA adj. Thermal and Fixed Magnetic Setting with Spreader Links & Rotary Handle – 1 No. ii. Digital VAF Meter with Volt,Amp, Frequency – 1 Nos iii. LED Indicator Lamp R,Y,B – 3 Nos iv. CT coils 100/5A – 3 Nos v. Control Fuse – 3 Nos vi. Copper Bus Bar 150A TPN with Colour Seleve. Outgoings i. MCCB 100A 4Pole Breaking Capacity 18 KA Adj. Thermal and Fixed Magnetic Setting with Spreader Links & Rotary Handle – 2 Nos ii. MCCB 63A 4Pole Breaking Capacity 18 KA Adj. Thermal and Fixed Magnetic Setting with Spreader Links & Rotary Handle – 2 Nos. iii. MCCB 32A 4Pole Breaking Capacity 18 KA Adj. Thermal and Fixed Magnetic Setting with Spreader Links & Rotary Handle – 2 Nos.
Dismantling existing unserviceable ACSR conductor of any size all as specified and directed.
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed.
Dismantling insulator any type, any size complete all as specified and directed
Dismantling of old unsv PCC poles any size incl taking out embedded portion in PCC and making good disturbed ground complete all as specified and directed.
Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
S & F Loop In and Loop Out Box pole mounted out door type Hot press Moulded SMC Junction Box of inside dimension not less than 300x300x150mm and outer dimension of 400x400x200mm with locking arrangement suitable for 240 V, 50 Hz including MCB SP of 6 Amp cap, fixing with 4/2 Nos Aluminium busbar of 30 Amp rating for Three/single phase with neutral, painted with powder coating in siemens grey colour including clamp for fixing with steel pole all as specified and directed.
Supply and fixing weather proof flat twin Core PVC insulated & sheathed Aluminium stranded conductor cables 1.5 sqmm drawn through street light pole duly making the hole upper and down both place and connection the street light to DB Box all as specified and directed.
Supply installation testing commissioning of 100 watt LED flood light built in die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting complete with all accessories pre wired and making connection with copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-JETAALBAFLOODLIGHT70W or Equivalent cat part of make as specified in Appx 'F' here in after.
Plain Cement Concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed.
Plain Cement Concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified and directed.
Dismantling/ taking down old HPSV light fittings from Hanger of any type and capacity and making good to the disturbed surfaces all as specified and directed.
Supply and fixing highbay Luminous capacity 200 watt (High Bay LED) having pressure die cast having, integrated PC Optics of 150 lum/Watt effacy, 4 kv in built and 10 KV external surge protection, IP 66 ingress protection including additions hanging chain, nut bolts clamps and all fixing and control switch (ON/OFF) arrangement at any height in hanger all as specified and directed. Make- BHINK 200W NB PC SD of Bajaj LED or equivalent make of Surya, Havells, Wipro. Note- All fixing arrangement and control switch (ON/OFF) arrangements directed by Engr-in-Charge included in quoted rates only.
Prakash Trading Corporation (BID ID -3081345)
M/S JIWAN SINGH (BID ID -3080581)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .