Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.9 L+₹38,600 (1.12%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹42.4 L+₹7.9 L (22.9%)Rejected-Finance 385 GROUND FLOOR GANESH MURTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹43.8 L+₹9.3 L (26.8%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹45.1 L+₹10.6 L (30.6%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
22 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
ADDITION / ALTERNATION OF COMMON TOILET AND CERTAIN OTHER SANCTIONED WORKS FOR INS SHIKRA AND OTHER AREAS UNDER AGE B/R - II (NW) NOFRA UNDER GE (NW) NOFRA COLABA MUMBAI
2020_MES_402914_2
8832
Open Tender
Civil Works
Item Rate
180 days
GE NW NOFRA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹96,000
Yes
30 Mar 2021
9 Jan 2021
27 Jan 2021
9 Jan 2021
22 Jan 2021
9 Jan 2021
60 days
Amount
Dismantling wrought iron or mild steel work of any description , complete all as specified and directed by Engineer-in-charge.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed by Engineer-in-charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises including removing of debris from site Defence land complete all as specified and directed by Engineer-in-charge.
Dismantling timber scantling 40 sqcm and over in section in any position framed work complete all as specified and directed by Engineer-in-charge.
Dismantling of translucent or asbestos cement corrugated / semi corrugated sheet as in roof covering complete all as specified and directed by Engineer-in-charge.
Demolition of brickwork or stone/boulder masonry, built in lime / cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing the rubbish outside MD land complete all as specified and directed by Engineer-in-charge.
M&L for brick work with sub class "B" bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed by Engineer-in-charge.
M&L brick work half brick with sub class "B" bricks straight or curved on plan in any radius in CM 1:4 complete all as specified and directed by Engineer-in-charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
S&F Rolled mild steel in roof trusses, (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angles, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde E-250) quality-A complete all as specified and directed by Engineer-in-charge.
S&F of framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angels, as necessary, Gussets plates, riveting etc. n exc 10 Kg each brackets, conforming to Fe-290 Gde-E-165 (Brackets over 10 Kg each to be measured under 'Structural Steel' complete all as specified and directed by Engineer-in-charge.
S&F of framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; (ornamental and intricate design) and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer-in-charge.
S&F of Mild steel plated (Plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed by Engineer-in-charge.
S&F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridge of roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F for Everest ceiling made out of 600x600x06 mm thick classic lite PVC laminated mineral fibre acoustics ceiling board/tiles deep panel suspender system made out of GI sheet main Tee and cross tees and angle including 3 mm GI wire for suspending ,bolts, necessary washer,nut/clits/pin hook etc for securing frame work to ceiling to the snap grid complete all as specified and directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position ( reinforcement cut as required to facilitate demolition), complete all as specified and directed by Engineer-in-charge.
Demolition of concrete of any description & in any position not otherwise specifically provided and removing debris outside MD Land complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:2:4), type B-0 (12.5mm graded stone aggregates) as in boundary wall fixing of posts etc, finished even & smooth without using extra cement, complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:2:4), type B1 (using 20 mm graded stone aggregate) as in coping and similar work complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded aggregate as in sub base of floor complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-charge.
M&L for rendering 10 mm thick cement plastering on ceiling surfaces in CM (1:3) finished even and smooth without using extracomplete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces, surfaces to be finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15 mm thick Rendering in cement mortar (1:4), on fair faces of brick/stone work and finised even and smooth without using extra cement , complete all as specified and directed by Engineer-in-charge.
M&L for 20 mm thick Rendering in cement mortar (1:4), on fair faces of brick/stone work and finised even and smooth without using extra cement , complete all as specified and directed by Engineer-in-charge.
M&L for rendering (15+5) 20mm thick in CM (1:4) brick/ concrete surface of walls finished even and smooth & mixing of integral WPC in 2nd layer (5mm thick) etc complete all as specified and directed by Engineer-in-charge. (NOTE : Integral WPC shall be measured separately).
Supply only for Integral waterproofing compound confirming to IS 2645 complete all as specified and directed by Engineer-in-charge.
M&L for 3mm thick wall care putty on plastered surfaces of internal wall etc complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plaster surface of wall and applying 2 coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat 3mm thick wall care putty and one coat of primer, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old distempered surface of wall and applying one coat of oil bound distemper complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of ceiling including scrapping and applying two coats of oil bound distemper over a coat of primer strictly as per manufactuure instruction with smooth roller finish complete all as specified and directed by Engineer-in-charge. MAKE : Asain Paint Tractor uno or Berger Bison or its equivalant in nerolac.
M&L for preparation of new / Old plastered surfaces of walls/Ceiling and applying two coats of acrylic emulsion exterior grade (100%) over a coat of primer complete all as specified and directed by Engineer-in-charge. (for storey from GF to fourteen floor) incl all necessary scaffolding etc. MAKE - a) Primer - Berger Seal-O-prime , Asian Paints SmartCare Primero , Pidilite Primeseal. b) Acrylic Paint - Berger weather coat all gaurd , Asian ultima , Nerolac Excel total.
M&L for painting of iron surfaces of any description, over 10 cm in width or grith, not otherwise described, including prepration of new surfaces with red oxide primer and two coats of synthetic enamel (ordinary tint) paint complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint,complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description not exc 1 Sqm each and refixing in the same opening after easing & adjusting complete all as specified and directed by Engineer-in-charge.
Plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed of Second Class hard wood complete all as specified and directed by Engineer-in-charge.
S&F of 35mm thick factory made 2nd class HW rail & stile plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-charge.
S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specification and drawings complete all as specified and directed by Engineer-in-charge.
S&F of factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site. complete all as specified and directed by Engineer-in-charge.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts complete all as specified and directed by Engineer-in-charge.
S&F for aluminium anodised, barrel tower bolts 200 mm of extruded section and fixed complete all as specified and directed by Engineer-in-charge.
S&F for 150mm size aluminium alloy handles, febricated type extruded section, ISI marked complete all as specified and directed by Engineer-in-charge.
S&F butt hinges 100mm mild steel hinges medium weight and fixed complete all as specified and directed by Engineer-in-charge.
Cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 depth of cutting exc half brick but n exc one brick complete all as specified and directed by Engineer-in-charge.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills and cutting chases for concealed water tubing or concealed conduit wiring, etc and making goood cutting exceeding 20 cm girth complete all as specified and directed by Engineer-in-charge.
M&L for MS flat for hold fast. Confirming to Fe-310-0 ro Fe-410-0 complete all as specified and directed by Engineer-in-charge.
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick ( square/Rectangular) area of each tiles exc 0.9 Sqm but not exc 0.18 sqm in floor including 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-charge. Make : Kajaria, Somany, Orient bell
M&L for coloured glazed ceramic tiles 350x250x7mm/ 450x350x7 mm thick but as on vertical surfaces such as skirting/dado including 15mm thick rendering in CM 1:4 complete all as specified and directed by Engineer-in-charge. Make : Kajaria, Somany, Orient bell
M & L Glazed coloured ceramic tiles in vertical surfaces 300mmx450mmx7mm thick including over 10mm thick rendering of cement mortar (1:4) for laying floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and as directed by the Engineer-in-Charge. Make : Kajaria, Somany, Orient bell
M & L for coloured vitrified tiles of area exc 0.36 Sqm, 10mm thick, laid in flooring, with & including 5mm thick adhesive of Ferrouscrete (FERRO-1122) / Fevimate XL- Pidilite / Gold star of Bal Endura or equivalant including necessary roughning of existing PCC flooring & levelling the floor if required, grouting the joints with white cement complete all as specified and directed by Engineer-in-charge. Make : Kajaria, Somany, Orient bell
M & L for coloured vitrified tiles of area exc 0.36 Sqm, 10mm thick, laid in skirting, over & including a backing coat of 10mm thick in CM 1:3, complete and making nosing at right angle corner, including levelling the wall, complete all as specified and directed by Engineer-in-charge. ( Note : Skirting shall be flush with the walls)
S&F for rotational moulded polyethylene water storage tank cylindrical hoisted & fixed in position all as specified capacity 500 ltrs complete all as specified and directed by Engineer-in-charge. Make : Sintex , Infra , Polycon
Taking up or down existing GI water tubing complete with all fittings of 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F GI tubing medium grade with all fittings like Tee, bend, elbow etc, 15 mm bore fixed to walls or ceilings with saddles/spacers complete all as specified and directed by Engineer-in-Charge. Make : TATA , Jindal , Zeneith
Taking up or down existing GI water tubing complete with all fittings of 20 mm bore complete all as specified and directed by Engineer-in-charge.
S&F GI tubing medium grade with all fittings like Tee, bend, elbow etc, 20 mm bore fixed to walls or ceilings with saddles/spacers complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CP Pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. Make : ESSCO , Jaquar , Kohler
S&F in repairs fancy type bib taps, chromium plated cast copper alloy 15mm bore with crutch or butter fly handle, screwed down, & fixed complete all as specified and directed by Engineer-in-Charge. Make : ESSCO , Jaquar , Kohler
S & F in repairs stop valve fancy type chromium plated screwed down, high presure with butterfly handle screwed both ends for pipe and fixed to pipe of 15mm dia bore complete all as specified and directed by Engineer-in-Charge. Make : ESSCO , Jaquar , Kohler
S&F in repair wash hand basin vitreous china white (flat back) of size 550x400mm including bracket 15mm dia 32mm dia waste coupling and 32mm dia PVC waste pipe 90cm long etc. complete all as specified and directed by Engineer-in-Charge. Make : CERA (1st Quality) , Jaquar , Hindware (1st Quality)
S&F in repairs chromium plated brass angle valve suitable for 15mm bore pipe, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs viterous china wash down water closet pan (Pedestal pattern) white incl 'P' or 'S' trap and making good the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. Make : CERA (1st Quality) , Jaquar , Hindware (1st Quality)
S&F in repair vitreous china squatting pan Orissa pattern long pan size 510 x 410 x 260 mm with CI trap 100mm with integral foot rest & fixing incl but (excluding flushing cistern and flush pipe) making good floor to match complete all as specified and directed by Engineer-in-Charge. Make : CERA (1st Quality) , Jaquar , Hindware (1st Quality)
S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and directed by Engineer-in-Charge.
S/F in repairs PVC valveless syphonic action type ,flushing cistern Low level white, with inlet ball valve ,float and handle 10 Ltr capacity including brackets complete all as specified and directed by Engineer-in-Charge. Make : CERA (1st Quality) , Jaquar , Hindware (1st Quality)
S & F Urinal bowl type or half stall pattern basin only including cinnection to flush pipe and out going pipes fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, Plastic water closet seat, black or white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodised various section as required for doors, window & partion etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement, handle, tower bolt for shutter, sealant etc complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (NOTE : Glazing, paneling to be paid separately),
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 104, 7.5 mm thick all as specified and as directed by Engr- in- charge.
S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples incl wooden beading complete all as specified and directed by Engineer-in-Charge.
S&F 3mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge. Make : Saint Gobain , Atul , Modi gaurd
Dismantling of stone slabs and tiles of any description or thickness as on paltform, shelves, floors etc laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding and rounding complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab as in flooring 20 to 25mm thick riser of steps, skirting, dado and pillar laid over including 15 mm thcik rendering in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
S&F in repairs cast iron floor trap 75 mm, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 75 mm bore cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 32 mm dia WHB/urinal /Sink flexible waste pipe all as complete all as specified and directed by Engineer-in-Charge.
S&F as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 , complete all as specified and directed by Engineer-in-Charge.
S&F in repairs barbed razor type concertina coil,9SWG hot galvanized spring tensile wire of UTS 145 to 150 N/Sqm,zinc coating 250 to300 gms/sqm, dia of coil when un-streched shall be 610 mm having minimum of coil (GI strip) 1.625 Kg/Rm, hot dip galvanised razar ribben tape of size 0.50 mm thickness,19mm wide before wraping on central core wire fixed ith 1.66 mm thick GI clips (minimum 25 Nos/RM) and special nut and bolts to hold two coils together and extra rows parallel wire of gauge complete all as specified and directed by Engineer-in-Charge.
S&F of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed by Engineer-in-Charge. (NOTE : Each line wire to be measured)
S&F of false ceiling with powder coated exposed GI grip suspension system (E-grip T-2430 or equivalent load carrying capacity with mid span deflection not exceeding. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm from a modular grid of 1200mm x 600m. Additinoal cross tees of 600mm shall be placed perpedicular to the cross tee 1200mm long to finally form a grip of 600mm x 600mm. Grip of modular size 600mm x 600mm shall be supported by 6mm dia GI wire from purlins / soffit with and including 6mm thick high pressure steam cured non asbestos fiber and fixed complete all as specified and directed by Engineer-in-Charge.
M&L 18/19mm thick ceiling boards 60x60 cm in size, fixed to snap grid false ceiling frame work of approved colour, type complete fixed in position complete all as specified and directed by Engineer-in-Charge. Make : Armstrong Optra RH95 or its equivalent in Ramco , Bison
S&F 12mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination,fixed to aluminium frame work, complete all as specified and directed by Engineer-in-Charge.
S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified. Make ; TATA , Jindal , SAIL
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified.
M&L for Reinforced cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
S&F as in repairs sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engineer-in-Charge.
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engineer-in-Charge. Make of cable : Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- Make of cable : Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on same board with other switches.
(e) S&F in repair bell push flush type 5 Amp complete ISI marked all as specified and directed.
Supply and fix in repair Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral), Anchor(Ave)
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin , 2 module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave).
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 3 module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave).
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave)
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral), Anchor(Ave)
Supply and fix support function blank plate single, 1 module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral), Anchor(Ave)
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular white cover plate with Frame 1 Module complete all as specified and directed. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave).
Supply and fix in repair Modular white cover plate with Frame 3 Module complete all as specified and directed. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular white cover plate with Frame 4 Module complete all as specified and directed. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular white cover plate with Frame 6 Module complete all as specified and directed. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular white cover plate with Frame 8 Module complete all as specified and directed. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular white cover plate with Frame 12 Module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular metal flush box 1 module including cutting and chassing complete all as specified and directed. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular metal flush box 3 module including cutting and chassing complete all as specified and directed Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave).
Supply and fix in repair Modular metal flush box 4 module including cutting and chassing complete all as specified and directed Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave)
Supply and fix in repair Modular metal flush box 6 module including cutting and chassing complete all as specified and directed. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular metal flush box 8 module complete all as specified and directed Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair Modular metal flush box 12 module complete all as specified and directed by Engineer-in-Charge. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix in repair baton intergrated LED channel 1x 20 WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make: Havells/Jaquar/Philips
S&F in repair baten intergrated LED channel 1x14 WH accessories internall prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make: Havells/Jaquar/Philips
Supply and fix in repair baton intergrated LED channel 1x10 WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make: Havells/Jaquar/Philips
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make: Havells, Legrand,Schneider.
(a) MCB TP 63 Amps, 240 Volts - 01 No
(b) MCB SP 6-40 Amps, 240 Volts - 09 Nos
(c) MCB SPN 63 Amps, 240 Volts - 01 No
S&F MCB, DB, SPN 8 way double door with protection type IP-42 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed by Engineer-in-Charge. Make : Siemens / GE / Legrand / L&T
S & F , MCB DP 63 Amps, 10 KA rating "B" series complete all as specified and directed by Engineer-in-Charge. Make : Siemens / GE / Legrand / L&T
S & F , MCB DP 20 Amps, 10 KA rating "B" series complete all as specified and directed by Engineer-in-Charge. Make : Siemens / GE / Legrand / L&T
Supply & fix in repair new exhaust fan 225/ 230mm sweep, 1400 RPM metallic body with louvers AC supply, single phase, 230 volts, 50Hz, complete fixing arrangements on the wall with nuts and bolts and making the good surfaces all as specified and directed at site. Make : Usha , Havells , Orient
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Make of cable : Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping
RAJU AND CO
MADHU ENTERPRIZES
I.J Enterprises
BOB ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .