Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
PROVISION OF CULVERT AND SPECIAL REPAIR TO JCO ACCN NO NP-97 AND TN-234 UNDER GE NAGROTA
2022_MES_510003_1
GEN-82/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE NAGROTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹90,000
Yes
25 Mar 2022
23 Feb 2022
18 Mar 2022
23 Feb 2022
16 Mar 2022
9 Mar 2022
60 days
Amount
Excavating over areas, n exc 1.5 m deep and getting out in hard / soft soil.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cms thick in any type of soil complete all as specified.
Removal of excavated material (soils) to a distance n.exc. 50m and depositing where directed at a level n. exc.1.50m above the starting point complete all as specified.
Cement concrete 1:3:6 Type C2 (using 40mm graded crushed stone aggregates) as in foundations, filling and mass complete all as specified.
M&L for Reinforced concrete pipes 1000mm bore class NP2 laid and jointed complete with collars all as directed by Engr-in-Charge
M&L for Cement concrete 1:3:6 type C2 Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for 1000mm Dia pipe all as specified and as direced by engr in charge.
M&L for hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface.
M & L 100mm thick PCC 1:4:8 Type D2 ( 40 mm graded aggregsate) as in subbase and pavings etc all as specified.
M & L 100mm thick PCC 1:2:4 Type B2 ( 20 mm graded aggregsate) as in subbase and pavings etc all as specified.
Taking down and refixing of existing chain link fencing/ barbed wire fencing/concertina coil fixing in angle iron including all fixing locking arrangement
Excavating in post holes (or similar holes) each n.exc 0.5 Cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer n.exc 25 cm, watering, and removing surplus soil to a distance n.exc 50 mtr and making good surfaces in hard/dense soil.
M & L cement concrete type B-2 1:2:4 (Using 40mm graded stone aggt) in foundation filling and mass concrete for post holes
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat ironfillets (for securing wire meshetc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 →including embeding in concrete and screwing etc. wind ties for roof including securing bolts
Preparation of new steel surfacesurfaces of any description, otherwise described, over 10 cm width or girth and applying two coat of Synthetic enamel paint (Ordinary tint) over a coat of pink primer.
Supply only Chain link fencing 3.8 mm mm dia galvanized PVC coating wire (50x50) mm mesh made upto matress lapped wire and laid on position / fixed on poles complete.
Fixing only chain link fencing including line wires, any mesh , size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire.
S & F in Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc., as directed.
S&F MS screw bolts (Machine made) 11 to 15mm dia exceeding 5cm & n exc 10 cm long hexagonal or square head at one end and screwed other end to be fixed with one washer and one hexagonal nut, the other end to be embedded in RCC fencing post while casting, completed all as specified and directed.
S & F M.S. Flat iron as in hold fast and similar small articles, cut to length, bent to shape, drilled hole and fixed with screw etc. conforming to Fe 410-0 or F 310-0 complete
M & L mild steel round bars10 mm dia and over cut into length bend to shape required incld cranking bending spirally for hooping for column, hooking ends and for strirrups spacers and binders binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips.
S&F concertina coil galvanished 60cm dia including securing tying at crossing with and provision of galvanished mild steel wire staples or steel pins etc all as directed including dismantiling of existing concertina coil wire
M/L 75 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in base of flooring/ hard standing finished evern & smooth w/o using extra cement..
M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and as directed
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness with grey cement and pigment, M-40 Grade etc all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm eachand n exc 4 sqm and removing from site.
Taking down shutter of any description area exc. 1 Sqm and n.exc. 2 Sqm and removing from site.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness.
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided.
Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion.
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc.
Pressed steel frames of size 165 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including two coats of synthetic enamel paint over one coat of red oxide complete.
Pressed steel frames of size 105 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including two coats of synthetic enamel paint over one coat of red oxide complete.
Box type Steel window side hung double shutters with provision for desert cooler/AC(inside for wire mesh & out side for glass), including guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded and fixed, steel window shall be conforming to relevant IS complete all as shown on drawing No CEUZ/TD/1302/09, Sh 1/3 to 3/3 and directed. Note:- Wire mesh and sheet glass shall be measured and paid separately
S & F Box type Steel windows with double shutters (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including two coats of synthetic enamel paint over one coat of red oxide complete.
Steel ventilators top hung double shutters (inside for wire mesh & out side for glass), including hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.Steel window shall be conforming to relevant IS all as specified. Note:- Wire mesh and sheet glass shall be measured and paid separately
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail penelling of plain colour PVC sheetto be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings.
Supply and fix for PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
Factory made, 2nd class hard wood, plain framed, Double/Single paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick complete, all as specified .
35mm thick 2nd class hard wood glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc ( without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8 clause 8.20(a), supplied and fitted to chowkats.
Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm dia and fixed with tinned tacks or galvanised mild steel staples
Sheet glass 3.00mm thick ordinary quality and glazing with oil putty complete all as specified and directed.
Same all as per item No 44 but pin head type glass.
Curtain rod 25mm dia aluminum brass polished with ends bulbs rings of required size including bracket complete all as directed.
M&L for PCC 1:2:4 type B-1 (20mm graded aggregate ) 25mm thick as in Sub base floor
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including 15mm thick screed bed in cement mortar 1:4 complete.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in Vetical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including 15mm thick screed bed in cement mortar 1:4 complete including dismantaling /demolation/Taking down Note:- Rates also includes in this item for necessary raking,circular cutting or notching and waste on tiles
M & L for Glazed ceramic colored tiles 300mmx600mmx 6 to 7mm thick,as in patches in vertical surfaces such as dado, skirting, wall etc set & jointed in neat cement slurry and pointed with coloured cement to match with tiles in over and including 10mm thick cement plaster in cement mortar 1:4. including dismantaling/demolation/Taking down Note:- Rates also includes in this item for necessary raking, circular cutting or notching and waste on tiles
100mm long butt hinges (medium weight) colled rolled mild steel fixed with welding.
Extruded aluminium alloy handles fabricated type anodised of size 125mm long
MS 300 mm ordinary rat rails rod pattern door springs including roller and roller plate.
Hold fast/clamps of mild steel stay for rain water pipes etc confirm to Fe-290 Gde E 165.
S& F Floor door stopper of aluminium alloy body and tongue ,anodised ,with hard drawn steel spring ,fixed in floor overall length of cover plate 140mm
Hasp and staple Alumnium anodised lncluding bolt to hinges plate 100mm size
300mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
Aluminium anodized 200mm long barrel tower bolt of extruded section and fixed.
S&F 18/19mm thick solid PVC board prelaminated one side and other side plain as in board/shelves/kitchen cabinate ( Board must be water proofing ,termite proof) .
Brick work with sub class “B” bricks straight or curved on plan exc 6M mean radius build in CM 1:6 using all as specified using old size bricks
Brick work with sub class “B” bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 using all as specified using old size bricks
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement all as specified ( internally)
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement with Water proffing compound all as specified (WPC measure and pais saperately)
M&L for Rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including two coat of white wash on ceiling including preparation of surface .
Supply only Liquid water proofing compound.
Taking down existing cement plaster of any description over damaged surfaces irregular facia, chajjas and in similar work and also for narrow width etc and rendering dubbing coat 15mm thick cement plaster in CM (1:4) over a coat of cement slurry @ 3.00 Kg/Sqm making surface even ( avg 50mm thick PCC 1:2:4 type B-1 using 20mm crushed stone aggregate shall be provided wherever required) followed by 05mm thick rendering in CM (1:3) finished complete all as specified and directed including two coats of weather proof exterior emulsion paint over a coat of primer on walls including preparation etc complete.(after curing of specified time and drying the surfaces as required). Note:-REPAIR OF CHAJJAS WORK SHALL BE PERSONALLY MONITERED BY GE.
Applying two coat of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description, not otherwise described over 10 cm width or girth including preparation of surfaces.
M&L for Complete removal of existing treatment applying two coats of oil bound distemper over a coat of wall putty 2 to 3mm thick on plasterd surfaces preparatory to distempering on wall surface .
M&L for Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall putty 2 to 3mm thick on plasterd surfaces preparatory to distempering on wall surface .
Preparing newly/old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
Complete removal of existing treatment and preparing of old plastered or unplastered surfaces of wall and applying two coats of weather proof exterior emulsion paint over a coat of primer on walls.
Three coat of white wash on newly plastered surface on wall including preparation of surface complete all as specified and directed.
Preparation of New plastered surfaces of ceiling and applying Three coat of white washing, all as specified.
Preparation of Old plastered surfaces of ceiling and applying two coat of white washing, all as specified.
M&L for Machine cut kota stone flooring 18 -22 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) over 15mm thick screed bed in CM ( 1:4) as in floor finished.
M&L for Machine cut kota stone slab 18-22mm thick in skirting, dado and pillars, risers of steps laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over 15 mm thick rendering in CM ( 1:4) including taking out of existing dado.
M&L for 18-20mm thick pre polished granite slab premium quality(with exposed edge duly grind and mirror polished) laid on Steps, kitchen platform top, window cill, steps, jambs and like set in neat cement slurry over and including15mm thick screed bed in CM 1:4, pointing in white cement with pigment to match the stone all as specified and directed by Engineer -in -Charge. Note :-Sample of Granite shall be approved by GE .
All as per item No 52 above but as on edges of cooking plateform laid over 15mm thick rendering in CM (1:3) -ditto-.
PCC 1:2:4 type B-1 as in benching, coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of roof, chajjas, rails, cills etc.
PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in plinth protection (75mm thick ) finished even and fair all as specified.
RCC 1:2:4 type B-1 ( using 20mm graded crushed stoneagg) as in chajjas, shelves and similar items.
Providing 75mm thick precast reinforced cement concrete slab 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) and set in CM 1:4 . ( NOTE : (reinforcement shall be measured and paid for separately).
Form work to chajjas, shelves ,troughs and similar items including edges.
Form work to edges of concrete flats RCC/PCC band exc 5 cm but exc 10 cm. Fair finished
TMT bars 10mm dia and over cut to lengths bent to shape required including cranking bending and spirally hoping for columns hooking ends and binding with MS wire annealed n.less then 0.90mm dia.
All as per item No 60 above but 6mm to 8mm dia -ditto-.
Providing number plate of size 450 x 300x20mm in CM 1:4 and writing building No of height 8 to 10cms with luminous paint through grooves of size 12 x 12mm ( Base: Black, grooves : orange)
Rotational moulded polyethene water storage tank 4 layered 500 ltr capacity hoisted and fixed in position including PVC float valve 20 mm bore and including dismantling of existing water storage tank complete. Make:-Vectus Golden ,Sintex.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store upto 25mm bore.
15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs.
20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs.
Cuttings chases for concealed water tubing of concealed conduit (cutting n.exc 10 cms girth) and making good in CM ( 1:3) in brick walls.
Shower rose brass chrominium plated 125mm size complete all as specified and directed.
15mm bore fancy type bib tap brass CP (Long body) with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed. Make:-Parryware cat part no PluntoG3806A1 or equivalent to jaquar
15mm bore fancy type CP brass Mixer, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed. Make:-Parryware cat part no Pluntot0741A1 or equivalent to jaquar
S&F Cast copper alloy CP angle Valve fancy type screwed both ends for iron pipe 15mm dia/ bore of pipe Make:-Parryware cat part no PluntoG3807A1 or equivalent to jaquar
All as per item No 96 above but with long shank and cup (concealed type) Make:-Parryware cat part no PluntoG3806A1 or equivalent to jaquar
Stop valves ,cast copper alloy ,screwed down high pressure , with crutch or butterfly handle , screwed both ends for iron pipe or for union 20mm dia Make:-Parryware cat part no PluntoT0712A1 or equivalent to jaquar
CP Pillar taps, 15mm fancy type cast copper alloy, with capstan heads, screwed down high pressure, without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed. Make:-Parryware cat part no PluntoG3801A1 or equivalent to jaquar
Soap dish with including chromium plated brass screws and wooden/plastic cleats ( Minimum weight 105gm). NOTE :-SAMLE HAS BEEN KEPT IN GE OFFICE.
Towel rail 600mm long of PTMT fixed with including chromium plated brass screws and wooden/plastic cleats ( Minimum weight 190gm). NOTE :-SAMLE HAS BEEN KEPT IN GE OFFICE.
Vitreous china wash down closet pan (Pedestal pattern) white with ‘S’&'P' trap plastic seat cover white including connection to out going pipe & to flushing pipe, anti syphonage pipe etc complete all as specified and directed by Engineer-in-charge (including making good to floor and fixing in repairs) excluding flushing cistern & flush pipe NOTE :-PARRYWARE PETITE CONCEALED E8309 PETITE PLUS OR EQUIVALENT IN JAQUAR
S & F in repairs,PVC valve less symphonic action type, flushing cistern, low level, white of capacity 10 ltrs with inlet , ball valve, float and and fixing arrangement complete. Make:-Parryware cat part no E8348 or equivalent to jaquar
Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar all as spd and directed by Engr in Charge.
Demolition and breaking up 200 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar all as spd and directed by Engr in Charge.
Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 150mm bore pipe, complete all as specified and as directed by Engr in charge.
Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 200mm bore pipe, complete all as specified and as directed by Engr in charge.
M & L for Salt -Glazed stoneware drain pipes 150 mm dia laind in trenches and jointed complete all as spd and directed
M & L for Salt -Glazed stoneware drain pipes 200 mm dia laind in trenches and jointed complete all as spd and directed
Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified.
Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 100mm.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 75mm bore.
S&F PVC (SWR) Bends any radius for 110mm bore.
S&F PVC (SWR) Bends any radius for 75mm bore with oval access door.
S&F PVC (SWR) Branch pieces single( Single Y) equal or unequal) for 110mm bore with oval access doors.
S&F PVC (SWR) Branch pieces single ( Single Y) equal or unequal for 75mm bore with oval access doors.
S&F PVC (SWR) vent cowl 75mm
Ditto as per item 90 above but 110mm
Taking down existing AC pipes any dia as in spouts etc and providing 110 mm bore PVC (SWR) pipes in short length as in spouts fixed with PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate.
Dismantling brick tiles or terracing tile, single layer on roof including cleaning the roof surface and filling the cracks with silicon compound if obsserved on roof
M&L for PCC 1:2:4 type B-0 (20mm graded aggregate ) 50mm thick as in padding finished even and smooth witout using extra cement
M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm .
M&L for Laying APP (atatic polypropylene) modified membrane 3mm thick and weighing not less than 3 kg/sqm with 160 GSM/sqm, non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap, the membrane has to be laid with LPG tourch and over lap sealed and finished neat over roof including a coat of bitumen 85/25 at the rate of 1.2 Kg per sqm over APP membrane. NOTE:-PONDING TEST SHALL BE DONE IN PRESSENCE OF GE AND WATER SHALL BE RETAINED FOR 72 HRS TO CHECK THE LEEKAGE AND EXTRA PAYMRNT SHALL BE PERMISSIBLE.
M&L for Cement concrete tiles 25 cm x 25cm x20mm thick machine pressed set jointed and pointed in neat cement slurry on roof over APP membrane laid over 15mm thick cement screed bed in cement mortar 1:6
Removing old tarfelt or polythene film including taking down plaster of sunken floor , roughening and cleaning by brushing with wire brush to remove all dirt and apply a coat of cement slurry with 3.00 Kg of cement per sqm and Rendering 15mm thick in CM 1:3 using WPC finished rough (sunken floor/wall) and then applying two course treatment as follow :-(i) Applying bitumen primer @ 0.40Kg/Sqm (ii) Laying APP (Atactic polypropylene) modified membrance 3mm thick and weighting not less than 3 Kg/Sqm with 100 GSM/Sqm non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap. The membrane has to be laid with LPG torch and over lap sealed and finished neat.
S&F as in repair kitchen rack made out of 0.63mm thick stainless steel sheet wall mounted type with 5/6 partition of size 60 cms x 90 cms x 25 cm fixed on wooden gutties complete all as directed by Engr-in-Charge.
Stainless steel Kitchen sink with drainage board made out of 1mm thick sheet for kitchen or laboratory with plug, washer, waste pipe etc including cast iron brackets, connecting union over all size 915mm X 460mm with bowl size 410mm X 330mm X 160mm complete
Vitreous china wash basin white flat back size 550 x 400mm incl waste pipe chain plugs and 32mm dia bore CP coupling complete as in repairs including a pair of bracket. Make:-Parryware cat part no Plunto C041B or equivalent to jaquar
Shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300 grams)
PCC 1:4:8 D-2 (using 40mm graded crushed stone aggregate) as a sub base to Durastone / Endura heavy duty tile ( 75mm thick ) finished even and rough.
M&L for Durastone / Endura heavy duty vitrified tiles of size 0.09 sqm but n exc 0.11 Sqm mm and having 9 to 10mm thick including over 15mm thick screeding in CM 1:4 as in floors and skirting set and jointed in neat cement slurry and pointed in white cement to match the surface complete all as specified and directed. NOTE :-SAMLE HAS BEEN KEPT IN GE OFFICE.
100mm bore CI floor trap with grating including jointing CI pipe in run lead, cutting holes in walls and making good surface in cement concrete surface type B-1 (1:2:4)
75mm bore CI floor trap with grating including jointing CI pipe in run lead, cutting holes in walls and making good surface in cement concrete surface type B-1 (1:2:4)
100mm bore CI Nahani trap with grating including jointing CI pipe in run lead, cutting holes in walls and making good surface in cement concrete surface type B-1 (1:2:4)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L polished vitrified tiles light shade 10mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exc 0.36 spm in floor etc set and jionted in neat cement slurry and pointed white or coloured cement to match including roughning of concrete surfaces over 15mm thick screed bed in CM 1:4.
M&L vitrified tiles light shade 10mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exc 0.36 spm in Skirting etc set and jionted in neat cement slurry and pointed white or coloured cement to match including roughning of concrete surfaces over 10mm thick screed bed in CM 1:4.
S&F pressed steel frame for door with two rebate incl necessary fixing lugs,hings,lock strike plate complete al as specified of size 125x60mm.
M/L 50 mm thick Cement concrete type B2, 1:3:6 (using 20 mm graded stone aggregate) in plinth protection complete all as specified.
M/L 75 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in base of flooring/ hard standing finished evern & smooth w/o using extra cement..
M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and as directed
Dismantling of Dismantling wrought iron or mild steel work of any description
Dismantling of corrugated or semi corrugated steel sheeting any gauge,thickness,including Nainital or similar pattern in roof covering.
Roof trusses (framed), tussed, purlins, rails and heavy bracket framing (beam, tee, angle, channel or flat section) incl distance pieces cleats etc compete all as specified.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F in repairs GI T Grid system in 600 x600 mm module which includes providing and fixing wall angle along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm centers. Then suspending the main tee tee of size from the soffit with help of soffit cleat, rawl plugs and wire rod with leveling spring slip at 1200 mm c/c.1200 mm cross Tee is then interlocked into the pre-cut slots in the main Tees at 600 mm centres in direction perpendicular to the main Tee to make a grid of 600x1200 mm. Finally 600 mm cross tee are then interlocked into the the pre cut slots in the 1200 mm centres and in direction parallel to the main Tee. Cross Tees having length more than 600 mm are to be supported indepently. 6 mm thick aqueostic tile square egde of size 595x595 mm shall be placed into the grid size of 600x600 mm. Grid specification:- (a) Main T- 24x32 thickness 0.3 mm and legth 3600. (b) cross T- 24x25 thickness 0.3 mm and legth 1200. (c) cross T- 24x25 thickness 0.3 mm and legth 1600. (d) wall angle- 24x24 thickness 0.4 mm and legth 3000. Make ; - Gyproc saint Gabin Gyproc/everest.
Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custedy for taking credit all as specified and as directed by Engr-in-Charge
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt, oiling & greasing and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed by Engr-In-Charge.
Taking down existing energy meters, keeping aside safely & refixing the same in its original position after making functional & after completion of point wiring/sub main wiring, complete, all as specified and directed by Engr-In-Charge. Note:- Small items required for fixing the electric energy meter at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
Taking down existing electric water heater, keeping aside safely & refixing the same to its original position after servicing of the whole geyser/making functional and after completion of wiring work, complete, all as specified and directed by Engr-In-Charge. Note: If any part found unserviceable during the refixing of water heater at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following;- (a) One light point controlled by one switch 5 Amp.
(b) One ceiling fan/exhaust fan point controlled by one switch 5Amp
(c) One socket out let 5Amp controlled by one switch on same board.
(d) One socket out let 5 Amp controlled by one switch on independent board.
(e) One bell point 5 Amp controlled by one bell push on independent board.
(f) One light point controlled by two, 2way switchs5 Amp
All as per item No 156 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board.
S&F switch piano flush type 5 Amps single pole one way complete,
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete.
S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed.
S&F bell push piano type 5 Amps complete.
S&F switch piano flush type 5 Amps 2 way complete.
S&F electric bell ding dong 230 volt AC complete,
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs.
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link TPN 4 way suitable for MCCBas incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site incl taking out of exsing UNSV DB with MCBs.
S&F MCB DP 63 Amps 10 KA 230 volts "C" series complete
S&F MCB single pole 6 to 30 Amps 10 KA 230 volts "C" series complete
S&F MCB single pole 40 Amps 10 KA 230 volts "C" series complete
S&F MCCB 125A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete.
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sq mm as earth continuity conductor connected to commen earth and earth dolly complete incl taking out existing UNSV service connections.
M&L for sheet steel box fabricated out of 2 mm thick CRCA sheet powder coated of size 60x60x25 cm duly compartmentalized suitable to accommodate 4 Nos Energy Meter independently. each compartment shall be provided with suitable door and 2 Nos fancy lock, complete, all as specified and directed by Engr-In-Charge incl taking out existing wooden meter box.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.
J S ENGINEERS
M/S MANISHA BUILDERS
M/S CHOUDHARY TRADERS
Mahajan Auto Traders
ASHFAQ AHMED MANHAS
SUNIL AND CO
M/S Shankardass Devidass
NARESH KUMAR AND COMPANY
Bidder Name
ASHFAQ AHMED MANHAS
M/S Shankardass Devidass
J S ENGINEERS
Mahajan Auto Traders
M/S MANISHA BUILDERS
ASHOKA ENGINEERS AND BUILDERS
SUNIL AND CO
NARESH KUMAR AND COMPANY
M/S CHOUDHARY TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .