Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹48.6 L+₹4.5 L (10.2%)Rejected-Finance 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹49.2 L+₹5.1 L (11.5%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Enlisted in appropriate category |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
19 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
PROVN OF THERMAL SENSOR SECURITY LIGHT AND THERMAL SENSOR STREET LIGHT AT VARIOUS LOCATION AND PROVN OF 150 KVA VOLTAGE STABILIZER AT AF STN SARSAWA UNDER GE(AF) SARSAWA
2023_MES_633960_1
8123/SAR-21/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹87,400
Yes
6 Mar 2024
22 Dec 2023
26 Jan 2024
22 Dec 2023
19 Jan 2024
5 Jan 2024
22 Dec 2023 - 5 Jan 2024
Amount
Supply install, testing and commissioning of sensor operated LED security lights ISO 9001 certified with following features-: (a) Input Power : 110-220 V, AC, 50 Hz. (b) IP rating : 65 © Battery backup : Min 4 hrs with lithium Battery (d) No of LEDs: 20x20 on both sides (e) Lux : 1100 (Per Side) (f) Power consumption : 20 Watt (g) LED light emitting colour: Red (h) Sounder: Strober/speaker activation on sensing of intrusion (provision of on/off shall be provided) (i) Programming: Normally off and activation with full intensity on sensing of intrusion. (j) Alarm management certification: UL 1076 (k) Sensing radius: 03 mtr (min) (l) Compatibility : Fully integrated with command control application Make- Remcon /RBH/Honeywell Note- (1) Work shall be carried out under supervision of manufacturer/OEM. (2) GI bracket, clamp wire J-Box shall be measured and paid seperately under respective items
S&F non metallic junction box made out of thermoplastic of size 250x250x160 mm for street light poles with connector for connection incoming and outgoing cables including provn of 01 No MCB SP 2 Amp to control the pole light circuit including 4 nos aluminium bus bars mounting on the insulator and fixing clamp made of FI 25x3 mm with back strip with suitable nut, bolts and washers including suitable size of double compression cable glands for incoming and outgoing cables complete all as specified and directed.
S&F 50 mm bore Light Grade GI pipe for fixing of street light complete all as specified and directed.
S&F of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.5 sqmm confirming to IS 694-1990 complete all as specified and directed
S & F of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
S & F clamps nuts, bolts, washers, in any shape or size as directed including one coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
Supply and fix copper wound Voltage stabilizer confirming to BIS 9815 (part 1):1994 (second revision) for automatic operation, three phase, naturally oil cooled, unbalanced type copper wound indoor type & designed for input variation between 360 V to 480 V with output voltage stabilized at 415 with accuracy ± 1 % irrespective of load and input voltage of and speed of correction 8 Volts per second between phase and neutral efficiency not less than 95 % and of capacity 150 KVA complete all as per IS 9815 (part 1):1994 or other relevent IS . NOTE- (a) The rates include for supplying stabilizer with standard fittings with protections like Over load/Short Circuit protections, High/Low voltage cut off,over temperature cut off,Bypass arrangement for emergency ,IC based controle circuit and installing complete including all jointing material connecting with electrical system earthing testing and commissioning . (b) The stabilizer will have its initial oil filling to appropriate level (cost of oil included testing with desired dielectric strength included in supplied and installed rate). (c) Factory testing of routine test of servo voltage stabilizer shall be carried out in factory premises of OEM in presence of rep of AO prior to dispatch information for which shall be given by the contactor to the dept atleast one month advance . (d) The contractor shall submit type test report of similar capacity or next higher capacity servo voltage stabilizer of any voltage range as per BIS clause 5.1 of 9815:1994 alongwith drg for approval of accepti8ng officer before procurement.
Supply and fixing Earthing to equipment with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth strip 32x6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth strip shall be protected by GI pipe 40 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
S& Laying XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with standard aluminium conductor of size 6 Sqmm 2 core laid in trench/wall complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
Returning, filling in including spresding leveling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Boring of holes under road, pavement, hard standing by trenchless technology including HDPE pipe of 25 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
G.H. INFRASTRUCTURE PRIVATE LIMITED
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .