Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC REASONABLE RATE | |
| 2 | L2₹51.9 L+₹97,651.23 (1.92%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance quoted high rate | |
| 3 | L3₹52.3 L+₹1.4 L (2.71%)Rejected-Finance | L3 | Rejected-Finance quoted high rate | |
| 4 | L4₹53.0 L+₹2.1 L (4.15%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L4 | Rejected-Finance quoted high rate |
Tender Value
₹57 L
EMD Value
₹1.1 L
Closing Date
12 Aug 2023, 4:00 pmClosed
CWE AF JAISALMER
HQ CWE AF Jaisalmer
REPAIR AND MAINTENANCE OF PUMPS MOTOR SET RO PLANTS CHLORONOME PLANTS AND ALLIED SERVICES AT AIR FORCE STATION JAISALMER
2023_MES_603725_2
80249
Open Tender
Civil Works
Item Rate
330 days
GE AF JAISALMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE AF JAISALMER
₹1.1 L
Yes
24 Aug 2023
24 Jul 2023
14 Aug 2023
24 Jul 2023
12 Aug 2023
31 Jul 2023
Amount
Disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump/mono block pump set of following capacity, electric driven 3 phase 415 Volts and replacementworn out spare parts including replacementnew gland packing and re-assembling, installation in the same location, commissioning & testing complete all as directed and directed. Notes:- (i) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (ii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
Centrifugal pump/mono block pump set of capacity 100/75 HP
Centrifugal pump/mono block pump set of capacity 60 HP
Centrifugal pump/mono block pump set of capacity 40 HP
Centrifugal pump/mono block pump set of capacity 30 HP
Centrifugal pump/mono block pump set of capacity 20 HP
Centrifugal pump/mono block pump set of capacity 15/12.5 HP
Centrifugal pump/mono block pump set of capacity 7.5 HP
Centrifugal pump/mono block pump set of capacity 5 HP
Centrifugal pump/mono block pump set of capacity 2 HP and 3 HP
Taking out existing unservicable submersible pump and motor of capacity 5 HP to 15 HP, 3 phase, 415 Volts, electric driven bore well and disconnecting electrical connections and delivery out let pipe and dismantling the motor and pump set complete and lowering in bore well after repairing/replacementspares parts including mechanical seal and nuts/bolts/washers of the same and testing including refixing of column pipes, submersible cables complete all as specified and directed. Notes : Repair work and spare parts of pumps and motor shall be measured and paid for separately under relevant items here-in-after.
Taking out existing unservicable submersible pump and motor of capacity 15 HP to 30 HP, 3 phase, 415 Volts, electric driven bore well and disconnecting electrical connections and delivery out let pipe and dismantling the motor and pump set complete and lowering in bore well after repairing/replacementspares parts including mechanical seal and nuts/bolts/washers of the same and testing including refixing of column pipes, submersible cables complete all as specified and directed. Notes : Repair work and spare parts of pumps and motor shall be measured and paid for separately under relevant items here-in-after.
Opening and reassembling of monoblock/centrifugal pump (motor) after rewinding & replacementworn out spare parts including taking out the burnt winding and rewinding of monoblock/centrifugal pump (motor) following capacity, Three Phase, 415 Voltss with solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacementunserviceable spare parts and reassembling the components & testing for function ability, complete, all as specified & directed. Notes:- (i) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (ii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
Monoblock/Centrifugal pump (Motor) 100 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 75 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 60 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 40 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 30 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 20 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 15/12.5 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 7.5 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 5 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 2 HP to 3 HP capacity, 3 phase, 415 Volts, 50 Hz
Monoblock/Centrifugal pump (Motor) 1 HP capacity, 3 phase, 415 Volts, 50 Hz
Opening and reassembling of submersible motor after rewinding and replacementworn out spare parts including taking out the burnt winding and rewinding of submersible motor 5 HP to 15 HP, Three Phase, 415 Voltss with solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacementunserviceable spare parts and reassembling the components & testing for function ability, complete all as specified and directed. Notes: (i) The include opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land. Motors will be given for repairing as per the site condition and need for repair being maintenance work. (ii) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (iii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
Opening and reassembling of submersible motor after rewinding and replacementworn out spare parts including taking out the burnt winding and rewinding of submersible motor 15 HP to 30 HP, Three Phase, 415 Voltss with solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacementunserviceable spare parts and reassembling the components & testing for function ability, complete all as specified and directed. Notes: (i) The include opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land. Motors will be given for repairing as per the site condition and need for repair being maintenance work. (ii) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (iii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
S&F in repair/replacementfollowing parts for existing centrifugal /Monoblock pump set electric driven 3 phase 415 Volts complete all as specified and directed.
S&F in replacement Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 100 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.
S&F in replacement Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 75 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.
S&F in replacement Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 60 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.
S&F in replacement Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 40 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.
S&F in replacement Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 30/20 HP Pump (Primary and secondary). Make : SKF /NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.
S&F in replacement Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 15/12.5 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.
S&F in replacement Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 7.5/5.0 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.
S&F in replacement Cooling fan motor suitable for Centrifugal/Monoblock Motor of capacity 100 HP
S&F in replacement Cooling fan motor suitable for Centrifugal/Monoblock Motor of capacity 60 to 75 HP
S&F in replacemen Cooling fan motor suitable for Centrifugal/Monoblock Motor of capacity 30 to 40 HP
S&F in replacement Cooling fan motor suitable for Centrifugal/Monoblock Motor of capacity 12.5 to 20 HP
S&F in replacement Cooling fan motor suitable for Centrifugal/Monoblock Motor of capacity 5 to 10 HP
S&F in replacement Centrifugal/Monoblock Pump motor MS coupling suitable for 100 HP motor (Beam, Jaw, Gear any type)
S&F in replacement Centrifugal/Monoblock Pump motor MS coupling suitable for 75/60 HP motor (Beam, Jaw, Gear any type)
S&F in replacement Centrifugal/Monoblock Pump motor MS coupling suitable for 30 HP to 40 HP motor (Beam, Jaw, Gear any type)
S&F in replacement Centrifugal/Monoblock Pump motor MS coupling suitable for 20 HP motor (Beam, Jaw, Gear any type)
S&F in replacement Induction Motor prelubricated ZZ bearing (DE and NDE) for 100 HP (Primary and secondary). Make : SKF/NBC/ TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per motor design. Both the bearings (as per motor frame type) to be replaced at the same time.
S&F in replacement Induction Motor prelubricated ZZ bearing (DE and NDE) for 75/60 HP (Primary and secondary). Make : SKF/NBC/ TATA/FAG/ UBC. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings (as per motor frame type) to be replaced at the same time.
S&F in replacement Induction Motor prelubricated ZZ bearing (DE and NDE) for 40/30 HP (Primary and secondary). Make : SKF/NBC/ TATA/FAG/ UBC. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings (as per motor frame type) to be replaced at the same time.
S&F in replacement Induction Motor prelubricated bearing (DE and NDE) for monoblock 20 HP. Make : SKF/NBC/ TATA/FAG/ UBC.
S&F in replacement Induction Motor prelubricated bearing (DE and NDE) for monoblock 15/12.5 HP. Make : SKF/NBC/ TATA/FAG/ UBC.
S&F in replacement Induction Motor prelubricated bearing (DE and NDE) for monoblock 7.5/5.0 HP. Make : SKF/NBC/ TATA/FAG/ UBC.
Dismantling, opening and reassembling of CI impellar and transportation to workshop and back after repair and refixing the same position at site and testing of CI impellar for centrifugal /Monoblock 60 to 100 HP pump set complete all as specified and directed.
Dismantling, opening and reassembling of CI impellar and transportation to workshop and back after repair and refixing the same position at site and testing of CI impellar for centrifugal /Monoblock 40 HP pump set complete all as specified and directed.
S&F in replacementCI impellar for centrifugal /Monoblock 20 HP pump set including taking out existing old unserviceable complete all as specified and directed.
S&F in replacementCI impellar for centrifugal /Monoblock 15/12.5 HP pump set including taking out existing old unserviceable complete all as specified and directed.
S&F in replacementCI impellar for centrifugal /Monoblock 7.5 HP pump set including taking out existing old unserviceable complete all as specified and directed.
S&F in replacementCI impellar for centrifugal /Monoblock 5 HP pump set including taking out existing old unserviceable complete all as specified and directed.
S&F in replacementPower Contactor for following capacity, Motor Starter (Amp rating as per site requirement) including removing of exiting burnt and unserviceable Power contactor and cleaning of carbon fixed as in repair complete all as specified and directed.
Power Contactor for 20 HP Motor Starter. Make: Havells/L&T/C&S
Power Contactor for 40 HP Motor Starter. Make: Havells/L&T/C&S
Power Contactor for 60 HP Motor Starter. Make: Havells/L&T/C&S
Power Contactor for 75 HP Motor Starter. Make: Havells/L&T/C&S
Power Contactor for 100 HP Motor Starter. Make: Havells/L&T/C&S
S&F in replacement Motor starter overload relay for following capacity, Motor Starter (Amp rating as per site) including removing of exiting burnt/US relay fixed as in repair complete all as specified and directed.
Motor starter overload relay for capacity 100 HP Motor Starter. Make: Havells/L&T/C&S
Motor starter overload relay for capacity 75/60 HP Motor Starter. Make: Havells/L&T/BCH
Motor starter overload relay for capacity 40 HP Motor Starter. Make: Havells/L&T/BCH
Motor starter overload relay for capacity 20 HP Motor Starter. Make: Havells/L&T/BCH
S&F in repair/replacement following parts for existing submerisble pump set 15 HP to 30 HP, electric driven, Three phase, 415 Volts complete all as specified and directed.
Thrust Bearing of suitable size motor as per site requirement.
Thrust plate with key of suitable size motor as per site requirement.
Thrust Bearing housing/bearing bush of suitable size motor as per site requirement.
Rotor Sleeve SS (Upper and Lower)/Sand Gaurd of SS of suitable size motor set as per site requirement
Motor Pump coupling SS including Key for suitable size motor as per site requirement
Brass impeller for 8 stage pump upto 5 HP to 15 HP
Brass impeller for 8 stage pump above 15 upto 30 HP
Body bush for capacity 15 HP to 30 HP pump set
For 12.5 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.
For 20 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.
For 25 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.
For 30 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.
For 40 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.
S&F in replacement DOL starter with wide band coil, Phase reversal preventation, Phase imbalance preventation, single phase protection, Auto/Manual mode of following capacity including dismantling & taking out old unserviceable DOL starter including dismantling & taking out old unserviceable starter complete all as specified and directed. Make : BCH/C&S/Havells /Legrand/L&T.
For upto 5 HP motor
For above 5 HP to 15 HP motor
M&L for Oiling and greasing of pump motor parts (any make any size any type) by means of greasing gun or manually by unbolting and separating the pump motor set at pump house inside defence area complete for smooth operation of machinery including replacementnut, bolts, washers of appropriate size as per site requirement and motor pump size complete making it leakage free and applying gland packing of necessary quantity and thickness and making working complete noise and leakage free and refixing in same original position complete all as specified and directed. Note: Rates for greese, lubricating oil and gland packing deemed to be included in quoted rates by the tenderer. Also, measurment of these items will be saperate and not to be included in any other item above
S&F in replacement Electronic type Single Phase Preventor suitable for 3 Phase, 415 Volts, motor VSP-3 of any make and any size complete as per sample including disconnecting & taking down old unserviceable Single Phase Preventor, complete all as specified and directed. Make : C&S/Havells/ABB/L&T
S&F in replacement Pre-stressed concrete Pole 9.00m long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including Excavation and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removal and including PCC 1:3:6, type C1 using 20mm graded crushed stone aggregate as in coping, foundation of poles/struts etc including necessary form work and including disconnecting & taking down old unserviceable broken RCC Pole complete all as specified and directed.
S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat primer, one under coat and one finishing coat of synthetic enamel paint including disconnecting & taking down old unserviceable complete all as specified and directed.
Preparation of existing old painted surface of any description such as Panels at any height and painted inside and outside (strictly existing shade) complete after scratching existing rusted surface then applying one coat of primer (superior quality) and synthetic enamel paint in blue colour all around the panels and plinth complete all as specified and directed.
Demolishing old existing broken Earth pit chamber and prepare new Earth pit chamber as per siter requirement and including putting RCC cover complete all as specified and directed. Note: Contractor shall be responsible for removing debris of old PCC chamber from site.
Supply, lay, joint and test XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volts grade cross sectional area 95 sqmm 3.5 core laid in trenches /ducts, through pipe, under floors or roads/along poles etc including dismantling & taking out old unserviceable cable complete all as specified.
Supply, lay, joint and test XLP insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volts grade cross sectional area 50 sqmm 3.5 core laid in trenches /ducts, through pipe, under floors or roads/along poles etc including dismantling & taking out old unserviceable cable complete all as specified.
Supply, lay, joint and test XLP insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volts grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, lay, joint and test XLP insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volts grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, lay, joint and test XLP insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volts grade cross sectional area 16 sqmm 4 core laid in trenches /ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed. Note for serial item No. 25 to 29 :- Sand cushioning, cable protection cover & excavation / earth work shall be measured & paid for seperately.
M&L for Dry sand (Local Tibba sand) to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes:- (i) Approved local tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured.
M&L for Stone patti 40 to 50 mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for laying of cables, pipes etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil.
Removing excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
S&F in replacement Cable of size 10 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Voltss grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.
S&F in replacement Cable of size 16 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Voltss grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.
S&F in replacement Cable of size 35 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Voltss grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.
S&F in replacement Cable of size 2.50 sqmm (nominal area), copper conductor, PVC insulated, sheathed, FRLSH with multi-stranded copper conductor, 1100 Voltss grade (ISI marked) cables, drawn through existing conduit fixed on surfaces of wall/ceiling complete including disconnecting & taking out carefully old unserviceable sub main wiring from existing serviceable conduit complete all as specified and directed. Note: Two run for Phase and Neutral of 2.50 sqmm cable shall be measured as one run length for payment purpose.
S&F in replacement LED flood lights of capacity 100 Watt, complete with all fittings and fixtures including disconnecting & taking out carefully old unserviceable complete all as specified and directed. Make : Havells Cat Part No. JETAIRISFLS100W LED757ASYMLTG or equivalent of Makes specified in Appendix"B".
S&F in replacement Aluminium conductor, steel reinforced (ACSR) of any size, any type, as per existing one and stringing properly on the insulators and binding with aluminium wire, connectors, Jumpers etc including disconnecting & taking down old unserviceable complete all as specified and directed.
S&F in replacement Disc type insulator, porcelain, vitreous 145mm high 255mm dia ball and socket type, white/brown/green, 11000 Volts grade, single disc assembly for tension with tension clamp for conductor working pressure 11000 Volts grade as in repair/replacement complete all as specified and directed. Make : Jaipuria Brothers/BHEL or equivalent.
S&F in replacement Pin type insulator porcelain vitreous, white, brown or green for working pressure 1100 Voltss, 100mm height and 65mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, fixed as in repair/ replacement complete all as specified and directed.
S&F in replacement Pin type insulator porcelain vitreous, white, brown or green for working pressure 11000 Voltss, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, fixed as in repairs, complete, all as specified and directed.
S&F in replacement Air break switch gang operated triple pole mechnically operated (GOD), mounted on insulator and steel frame, with (Verticle/Horizontal) operating mechanisum worked from ground level for current rating upto 200 Amps, 11000 Voltss, complete and testing on load, including taking down old unserviceable complete all as specified and directed. Make : Jaipuria Brothers/BHEL or equivalent.
S&F in replacementAir break (switch) insulator (DO assembly) for current rating upto 200 Amps, 11000 Voltss complete and testing on load including taking down old unserviceable complete all as specified and directed. Make : Jaipuria Brothers/BHEL or equivalent.
M&L for Topping up/replacementtransformer oil of transformer chamber and conservator with new transformer oil upto a required level of 35 KV di-electric strength including dehydration of transformer oil to withstand for one minute in any type and capacity of transformer complete all as specified and directed. Make: Power by Apar or equivalent
Trimming of branches of tree any size and any length coming in contact with conductor and GOD/two pole structure area complete all as directed. Note:- Trimming of branches of tree any numbers of conductor shall be measured one run for payment purpose.
S&F in replacement MCCB, 4 Pole, 400 Amps rating, rupturing capacity 36 kA, 415 Volts grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F in replacement MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volts grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F in replacement MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volts grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F in replacement MCCB, 4 Pole, 125 Amps rating, rupturing capacity 16 kA, 415 Volts grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F in replacement MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volts grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F in replacement MCB Triple Pole with Neutral with overlaod and short circuit protection 'C' Series, 63 Amps rating, rupturing capacity 10 kA, 415 Voltss, AC supply, 50 Hz, including disconnecting & taking down old unserviceable MCB, complete all as specified and directed.
S&F in replacement MCB Single Pole with Neutral with overlaod and short circuit protection 'C' Series, 40 Amps rating, rupturing capacity 10 kA, 415 Voltss, AC supply, 50 Hz, including disconnecting & taking down old unserviceable MCB, complete all as specified and directed.
S&F in replacement MCB Single Pole with overlaod and short circuit protection 'C' Series, 40 Amps rating, rupturing capacity 10 kA, 415 Voltss, AC supply, 50 Hz, including disconnecting & taking down old unserviceable MCB, complete all as specified and directed.
S&F in replacement Cable jointing kit for 11000 Voltss grade HT cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm 3 core to 95 sqmm 3 core and including dismantling & taking out old unserviceable jointing kit complete all as specified & directed
S&F in replacement Cable jointing kit for 11000 Voltss grade HT cable for out door termination end heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm 3 core to 95 sqmm 3 core and including dismantling & taking out old unserviceable jointing kit complete all as specified & directed
S&F in replacement Cable jointing kit for 11000 Voltss grade HT cable for indoor termination end heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm 3 core to 95 sqmm 3 core and including dismantling & taking out old unserviceable jointing kit complete all as specified & directed
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 25mmx4mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No 03 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 40mm bore GI pipe medium grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm, bolts, nuts and washers 75mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc including dismantling & taking out old existing unserviceable earthing complete all as specified. Note:- PCC chamber shall be constructed at least 1.5m away from the earth electrode. The pipe for watering shall be provided in slanting manner.
S&F in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron wire including disconnecting & taking out old existing unserviceable complete all as specified. Note : Nut, bolt and other items included in quoted rate by the tenderer.
S&F in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4mm strip galvanised iron including disconnecting & taking out old existing unserviceable complete all as specified. Note : Nut, bolt and other items included in quoted rate by the tenderer.
S&F in replacement Test point terminal block Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia, 25mm long hexaguanal head screw including disconnecting & taking out old existing unserviceable complete all as specified.
S&F in replacement 80mm bore GI heavy grade column pipe in 6 metre length with GI flange on each end, screwed and welded (Not less than 12mm thick) with four Nos MS flat of size 12x6mm supports (10mm long each) on each flange with suitable slot/groove for submersible cable, including bolts, nuts, washer & rubber packing for flanged joints of pipes, including disconnecting & taking out old existing unserviceable complete all as specified and directed.
S&F in replacement 100mm bore GI heavy grade column pipe in 6 metre length with GI flange on each end, screwed and welded (Not less than 12mm thick) with four Nos MS flat of size 12x6mm supports (10mm long each) on each flange with suitable slot/groove for submersible cable, including bolts, nuts, washer & rubber packing for flanged joints of pipes, including disconnecting & taking out old existing unserviceable complete all as specified and directed.
S&F in replacement 10mm thick gland packing in small packets for valves and motor pumps fixed as in repair complete all as specified & directed.
S&F in replacement 12mm thick gland packing in small packets for valves and motor pumps fixed as in repair complete all as specified & directed.
S&F in replacement 15mm thick gland packing in small packets for valves and motor pumps fixed as in repair complete all as specified & directed.
S&F in replacement 20mm thick gland packing in small packets for valves and motor pumps fixed as in repair complete all as specified & directed.
Cuttings grass/herbs near installation, plant and sumps complete cleaning of installation, valve chamber and cleaning of installation including necessary tools and safety measures where ever required complete all as specified and directed.
S&F in replacement 200mm bore CI reflex valve/Non return valve (NRV), cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed.
S&F in replacement 150mm bore CI reflex valve/Non return valve (NRV), cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed.
S&F in replacement 100mm bore CI reflex valve/Non return valve (NRV), cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed.
S&F in replacement 80mm bore CI reflex valve/Non return valve (NRV), cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint and including dismantling & taking out old unserviceable non return valve complete all as specified and as directed.
S&F in replacement 50mm bore Cast Iron/Gun Metal foot valve of size (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
S&F in replacement 80mm bore Cast Iron/Gun Metal foot valve of size (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
S&F in replacement 100mm bore Cast Iron/Gun Metal foot valve of size (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
S&F in replacement 150mm bore Cast Iron/Gun Metal foot valve of size (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
Testing of Sewage Water {(Stilling chamber (Inlet)} and Treated Water (Outlet) sample at authorised government laboratory for biological fitness of water (pH Value, total Suspended Solids, Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), total Residual Chlorine, total Coliform) on quaterly basis including glass bottle for collection of sample complete all as specified.
Maintenance and cleaning of transformer of capacity 160 KVA to 200 KVA including drain out the transformer oil using dehydration machine opening the top cover change of all gasket, bushing, checking for leakage, loose contacts in winding/bushing removing the paint of transformer using energy paper and repainted using spray gun by superior quality paint of approved colour and testing the transformer complete all as specified and directed. Note: Transformer oil required for topup shall be procured under item No 61 above.
Maintenance and servicing of DG Set capacity 63 KVA complete including draining out of Diesel from tank, cleaning the tank thouroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner. change air cleaner elements, check collant level & make up the same, drain the Fuel Filter & water separator, filling the starting batteries with electrolyte/ distilled dwater to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-Belts, changes rubber hoses and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc, adjust/ set the same for proper functioning of DG Set, checking of fuel, oil and water/ Coolant level etc,adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the manufacturer and test for satisfactory running of DG Set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, Voltsage, frequency, load current, battery charging, fuel consumption etc complete all as specified and directed.
Maintenance & servicing of DG Set capacity 100 KVA to 160 KVA complete including draining out of Diesel from Tank, cleaning the tank thouroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner. change air cleaner elements, check collant level & make up the same, drain the Fuel Filter & water separator, filling the starting batteries with electrolyte/ distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-Belts, changes rubber hoses and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc, adjust/ set the same for proper functioning of DG Set, checking of fuel, oil and water/ Coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the manufacturer and test for satisfactory running of DG Set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, Voltsage, frequency, load current, battery charging, fuel consumption etc complete all as specified and directed.
S&F in replacement of water proof LED 18W stainless steel LED nozzle type/suitable for fountain water proof RGB multi-colour lamp IP-68 compatible for both fresh or salt water pool, different mode, dimming, brightness adjustment store mode for more than 30 lighting effects, etc. complete all as specified and directed.
S&F in replacement 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), double layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule histed and fixed including dismentling and taking down old unserviceable water tank capacity 1000 litres complete as specified in SSR Part-I. complete all as specified and directed.
S&F in replacement 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), double layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule histed and fixed including dismentling and taking down old unserviceable water tank capacity 500 litres complete as specified in SSR Part-I. complete all as specified and directed.
S&F in replacemen Chlorine Dozing Pump 0-6 LPH with flow of 4 KG/CM2 with all fittings and fixtures complete all as specified and directed. Make : Aventura Model No- Micro V.1.4 or equivalent.
M&L for Servicing of blower of capacity 760 Cum/Hour with pressure 0.65 Kg/SqCM of RPM 1000, including replacementPaper filter of blower of Make : Everest Model M-710 complete all as specified and directed. Note : All necessary Tools & Plants required for servicing to be included in quoted rates.
M&L for Servicing of Decanter Centrifuge including greasing of Bearing at Feed/ Slurry end and Main Bearing at Liquid discharge, Cleaning of Scroll/ Conveyor, Bowl, Pump blades complete by authorised OEM manufacturer of Make : Alfa Laval. Note : All necessary Tools & Plants required for servicing to be included in quoted rates.
S&F in replacement V Belt, Heat and Oil resistant of Model SP13, 2150 complete all as specified and directed. MAKE : FENNER or equivalent.
S&F in replacement Cable of size 6 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.
S&F in replacement Cable of size 25 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.
M&L for Opening and reassembling of Non clog submersible motor (STP motor) after rewinding and replacementworn out spare parts including taking out the burnt winding wire and rewinding of submersible motor following capacity with new PVC insulated solid copper conductor (wire) superior quality of approved make, gauge/size & number of wire as per existing including insulation material and for suitable RPM including rotor balancing, minor spares, fixing new mechanical seal for avoiding of shorting of motor and replacementunserviceable spare parts and reassembling the components & testing for function ability including taking old unserviceable motor from treated water tank complete all as specified and directed. Note: The Job include the opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land. Motors will be given for repairing as per the site condition and need for repair being maintenance work.
Submersible motor of capacity 25 HP, 3 phase, 415 Voltss
Submersible motor of capacity 10 HP, 3 phase, 415 Voltss
Submersible motor of capacity 7.5 HP, 3 phase, 415 Voltss
Submersible motor of capacity 3.0 HP, 3 phase, 415 Voltss
M&L for Opening and reassembling of STP monoblock /centrifugal pump (motor) after rewinding and replacementworn out spare parts including taking out the burnt winding wire and rewinding of monoblock/ centrifugal pump (motor) following capacity, Three Phase, 415 Voltss with new PVC insulated solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacementunserviceable spare parts and reassembling the components & testing for function ability, complete, all as specified & directed. Note: (i) The include opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land and testing of RPM to be done after installation on Ground after rewinding. Motor will be given for repairing as per the site condition and need for repair being maintenance work. (ii) Unit rate (quoted by the tenderer) shall be deemed to included for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
Monoblock/Centrifugal motor of capacity 40 HP, 3 phase, 415 Voltss
Monoblock/Centrifugal motor of capacity 12.50 HP, 3 phase, 415 Voltss
Monoblock/Centrifugal motor of capacity 7.50 HP, 3 phase, 415 Voltss
Monoblock/Centrifugal motor of capacity 5 HP, 3 phase, 415 Volts,
Monoblock/Centrifugal motor of capacity 1.50/2.0 HP, 3 phase, 415 Voltss
S&F in replacement Deep Groove ball/roller bearing (Double sealed ball bearing) for the following capacity of STP Pump (Primary and secondary) complete all as specified and directed. Make : SKF/NBC/TATA/FAG/UBC. Note: The rates include cost of two nos bearing as per pump design. Both the bearings(as per pump make) to be replaced at the same time.
Centrifugal pump/mono block pump set of capacity 40 HP
Centrifugal pump/mono block pump set of capacity 12.5 HP
Centrifugal pump/mono block pump set of capacity 7.5 HP
Centrifugal pump/mono block pump set of capacity 5.0 HP
Centrifugal pump/mono block pump set of capacity 1.5/2.0 HP
S&F in replacement Centrifugal/Monoblock STP Pump motor MS coupling capacity 40 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed.
S&F in replacement Centrifugal/Monoblock STP Pump motor MS coupling capacity 12.5 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed.
S&F in replacement Centrifugal/Monoblock STP Pump motor MS coupling capacity 7.5/5.0 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed.
S&F in replacement Centrifugal/Monoblock STP Pump motor MS coupling capacity 1.5/2.0 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed.
S&F in replacement 80mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed.
S&F in replacment 100mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed.
S&F in replacement 150mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, 1 ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed.
S&F in replacement 200mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed.
S&F in replacement 300mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed.
S&F in replacement 40mm bore Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including dismantling & taking out old unserviceable valve complete all as specified & directed.
S&F in replacement 65mm bore Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including dismantling & taking out old unserviceable valve complete all as specified & directed.
S&F in replacement 100mm bore Cast iron body butter fly valve heavy duty, ISI marked with confirming to IS, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 100mm bore, complete all as specified & directed.
S&F in replacement Cast iron body butter fly valve heavy duty, 150mm bore, ISI marked with confirming to IS, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 150mm bore, complete all as specified & directed.
S&F in replacement PVC cable, 2.5 sqmm, 2 core, nominal area of copper conductor, insulated and (Flame Retardant) FR PVC round sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694 including taking down old unserviceable cable complete all as specified and directed. (Note :- Two run for Phase and Neutral shall be treated at One run).
S&F in replacement LED street light 90 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP 66 protection and impact resistance of IK07 including taking down old unserviceable LED street light complete all as specified and directed.
Supply, layi joint, commission and test 150mm bore DI pipes with rubber gasket Tyton Joints of spigot and socket ends centrifugally cast (spun) class "K-7" conforming to IS-8329 -2000 in any length laid in trenches ncluding taking up or down old unserviceable CI/DI water tubing and connections of 150mm bore complete all as specified and directed.
S&F CI/DI fitting upto 150mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, staright, bend, increasing, decreasing or double socket extra Tee pieces single branch Ý'Junction, double branch, cross collars caps etc complete all as specified and as directed.
Supply, lay and joint (By butt fusion welding method) in standard length BIS marked (high density polyethylene Pipe) HDPE pipe suitable for potable water as per IS specification No 4984/1995 (Pressure rating 6 Kg/Cm2 PE-100) and fittings (specials suitable to HDPE pipes) including taking down old unserviceable pipe complete all as specified and directed.
25mm nominal dia HDPE Pipe (Outer Dia)
40mm nominal dia HDPE Pipe (Outer Dia)
63mm nominal dia HDPE Pipe (Outer Dia)
90mm nominal dia HDPE Pipe (Outer Dia)
125mm nominal dia HDPE Pipe (Outer Dia)
160mm nominal dia HDPE Pipe (Outer Dia)
180mm nominal dia HDPE Pipe (Outer Dia)
Rectification of Leakages by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to DI/CI/ HDPE of following sizes pipe with MS clamp including rubber cushioning, 3mm thick and 300mm wide with hole drilled for nutbolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed. Note: Cost of JCB for lifting of pipe for repair will be part of quoted rates.
40mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia)
63mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia)
90mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia)
125mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia)
160mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia)
180mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia)
Unlowering and lowering the Non clog submersible pump of any capacity and removing dirt, waste from it and clean it and making it serviceable complete all as specified and directed.
S&F in replacement Automatic digital starter suitable for RO Plant of capacity 1000 Litre/hour fixed as in repair complete all as specified and directed.
S&F in replacement Water flow meter (rotameter) suitable for RO Plant of capacity 1000 Litre/hour fixed as in repair complete all as specified and directed.
S&F in replacementWater flow meter (rotameter) suitable for RO Plant of capacity 2500 Litre/hour fixed as in repair complete all as specified and directed.
S&F in replacementJambo micro filter candle for RO Plant (threaded), 4.50" (Inches) wound complete as per sample all as specified and directed
Supply and pour Antiscalant soluton (suitable for RO plants) complete all as specified and directed.
Supply and pour NaCl (Sodium Chloride) for water softening of RO Plant complete all as specified and directed.
Supply and pour PH Corrector/Booster for RO Plants complete all as specified and directed.
S&F in replacement Membrane suitable for RO Plant, flow 250 LPH, rejection (%) : 99.67, Model No. CPA2-4040 Nitto of Hydranautics or equivalent of Daw/GE, fixed as in repair complete all as specified and directed.
S&F in replacement Pabbels and Gravels, Fine Sand for FRP vesseel in lot of 50 Kg bags premixed for filling into vessel FRP/PGV vessel and cleaning the around area and repacking the vessel after filling in new items complete by means of packing and fixing material including labour and testing for appropriate pressure including taking down old unserviceable complete all as specified and directed.
S&F in replacement Activated Granular Carbon (Charcoal 900 IV) for 21X62 FRP vesseel in lot of 25 KG bags for filling into vessel including draiing out the existing used Charcoal from FRP vessel and cleaning the around area and repacking the vessel after filling in new items complete by means of packing and fixing material including labour and testing for appropriate pressure including taking down old unserviceable complete all as specified and directed.
S&F in replacement Dozing pump feeder for injecting PH booster, Antiscalent, chlorine with dosing Rate : 6 LPH @ 4 Kg/Sqcm, 400 Max Stroke/ Minute fixed as in repair complete all as specified and directed. Make: Aqua/Aventura or equivalent.
Disconnection of all pressure tubes from the RO Plant and taking out all membranes from pressure tubes cleaning the same with citric acid (low pH) and solium hyppchloride (high pH) and complete washing with RO water and re-assembling the same complete all as specified and directed.
S&F in replacement UV Lamp for capacity 40 watt for UV Filter sutiable for RO of capacity 3000 LPH fixed as in repair complete all as specified and directed.
S&F in replacement UV Lamp for capacity 20 watt for UV Filter sutiable for RO of capacity 1000 LPH fixed as in repair complete all as specified and directed.
Supply, install, connect and test Electric driven Centrifugal Self Priming Pump of capacity 0.75KW/1.0 HP, size 25X25mm with speed 2760 RPM, insulation 'B' Class with max Current 9 Amps with head range 6/30 M, Discharge Range 60/10 LPM, Single Phase, 50 Hz, Duty-S1 complete with all fittings fixed as in repair complete all as specified and directed.
Supply, install, connect and test Electric driven Centrifugal monoblock pump set of capacity 5.0 HP / 3.7 KW, Three Phase, 50 Hz, 415 Voltss, head range 18 metre with class 'B' insulation of suction and delivery size 80x80mm including necessary fixing arrangement and inlcuding taking down old unserviceable pump complete all as directed. Make : Kirlosker Model KDS 520+ or equivalent/CG/Havells
S&F in replacement Plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through suitable feeder in pressurised line stequa 411E fixed as in repair complete all as specified and directed. Make: Declibac,Potter & Watts/Brio Zing or equivalent
S&F in replacement FRP vessel of size 13X54 (150PSI) Max Design Pressure 0-10 bar for RO plant at 15 Air Force Hospital fixed as in repair complete all as specified and directed. Make: Pentair/Starlite/Aventura or equivalent.
S&F in replacement Membrane RO/UF Pressure Vessel for RO Plant of Model Wave-250E-4 with maximum operating pressure 250 PSI (17.24 Bar) with operating temperature range - 7°C (20°F) Min 55°C (131°F) Max complete with all fittings fixed as in repair complete all as specified and directed.
S&F in replacement 5000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), double layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule histed and fixed including dismentling and taking down old unserviceable water tank capacity 5000 litres complete as specified in SSR Part-I. complete all as specified and directed.
S&F in replacement Stainless Steel, Multistage high pressure pump (vertical type), Centrifugal Pump capacity 5.0 HP, 3 Phase, 415 Volts, 50 Hz, from RO plant, including dismantling the pump set and old unserviceable centrifugal pump set with motor complete all as specified and directed.
S&F in replacement Stainless Steel, Multistage high pressure pump (vertical type), Centrifugal Pump capacity 3.0 HP, 3 Phase, 415 Volts, 50 Hz, from RO plant, including dismantling the pumpset and taking down old unserviceable centrifugal pump set with motor complete all as specified and directed.
S&F in replacement Galvanized steel water tubing medium grade of 15mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
S&F in replacement Galvanized steel water tubing medium grade of 20mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
S&F in replacement Galvanized steel water tubing medium grade of 25mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed.
S&F in replacement Galvanized steel water tubing medium grade of 40mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed.
S&F in replacement Galvanized steel water tubing medium grade of 50mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 50mm bore, complete all as specified and directed.
S&F in replacement Galvanized steel water tubing medium grade of 80mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 80mm bore, complete all as specified and directed.
S&F in replacement Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 50mm bore pipe line fixed as in repair complete all as specified & directed.
S&F in replacementGun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 40mm bore pipe line fixed as in repair complete all as specified & directed.
S&F in replacementGun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe line fixed as in repair complete all as specified & directed.
S&F in replacement Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 20mm bore pipe line fixed as in repair complete all as specified & directed.
S&F in replacement Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 15mm bore pipe line fixed as in repair complete all as specified & directed.
S&F in replacement Gun Metal foot valve of size 50mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
S&F in replacement Gun Metal foot valve of size 80mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
Preparation/cleaning of old painted steel surface of any description such as suction line, delivery line, priming line or any other pipe line/channel plates complete with scraping out old painted surface and after that marking of flow direction along with painting as per colour code complete all as specified and directed. (Make of Paint : Asian/Berger or equivalent)
S&F in replacemnt Pressure motor of capacity 1 HP suitable for automatic operation : Pump turns on/off as per the requirement of pressure, motor should be fitted with thermal overload protector to protect the motor from overheat damamge, motor should be suitable for outdoor operation complete all as specified and directed.
M&L for Rubber gasket tyton joint (push on joint) including rubber ring suitable for 80mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified & directed.
M&L for Rubber gasket tyton joint (push on joint) including rubber ring suitable for 100mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified & directed.
M&L for Rubber gasket tyton joint (push on joint) including rubber ring suitable for 150mm bore socket & spigot CI pipe and fittings including taking down old unserviceable complete all as specified & directed.
Supply, lay and joint following size of CPVC Chlorinated Polyvinyl Chloride Pipes SDR 11 & plain CPVC SDR 11 complete all fittings fixed on walls/ceiling or in floors fixed as in repair complete all as specified and directed.
20mm outer dia
25mm outer dia
32mm outer dia
Rectification of leakaging in water main pipe line by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to existing DI/CI pipe line following sizes by melting the lead with the help of burner/blower including taking out old spun yarn and re-jointing with & including additional quantity of Pig lead required and good quality of spun yarn, lead wool ring etc and testing of joint including dewatering complete all as specified and directed. Note: Cost of JCB for lifting of pipe for repair will be part of quoted rates by the tenderer.
100mm bore CI/DI Pipe lines
150mm bore CI/DI Pipe lines
200mm bore CI/DI Pipe lines
300mm bore CI/DI Pipe lines
Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing Galvanised Iron pipes lines following sizes and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed. Note:- (i) The rate is deemed to include for one fitting/special (complete unit) as required at site. (ii) Rate quoted shall be deemed to be inclusive of necessary dewatering and excavation (Upto one length of 6 RM) filling making good the existing surfaces with the necessary T&P, accessories of appropriate size as required complete all as directed.
15/20mm bore GI Pipe lines
25mm bore GI Pipe lines
40mm bore GI Pipe lines
50mm bore GI Pipe lines
80mm bore GI Pipe lines
Testing of RO water sample for chemical examination of drinking water (such as coliform bacteria, nitrates, pH value, sodium, chloride, fluoride, sulphate, iron magnase, hardness etc) by authorised government laboratory complete for SMQ RO plant, 15 AFH RO plant, Chandan RO plant and Ramgarh RO plant all as specified and directed. Note: Water sample collect and testing to be done every quarterly basis (03 months) and report of the same to be submitted to Engineer-in-Charge and GE.
S&F in replacement Air circuit breaker, 4 Pole, 415 Volts, 65 KA of capacity 2000 Amp make : L&T model No CNCS 2000 SI SL 960660000 or equivalent in Havells or C&S.
Construction of stone masonary valves pit of size 900mm x 900mm x 900mm (internal dimention of chamber) stone masonry bulit in cement mortar (1.6) for sluice valve chamber including necessary excavation, foundation concrete in PCC (1:4:8) type D-2 using 40mm graded stone aggregate for foundation and 15mm thick inside cement plaster in cement mortar (1:4) with floating coat of near cement slurry, PCC coping (1:2:4) type B-1 using 20mm graded stone aggregate including necessary form work with MS frame with angle iron 50x50x6 mm and cover of MS sheet 3.15mm thick including tarring and painting (where required) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime all as specified and locking arrangement directed.
S&F in replacement 80mm bore Cast Iron reflex valve/Non return valve (NRV), cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and directed.
Servicing of pressure sand filter for flow rate of 35 cum/hour with working pressure 1 to 7 Kg/Sqcm of dia 1500mm and height 1800mm outdoor type at Ramgarh complete all as specified and directed.
Servicing of water softening plant complete of capacity 23000 LPH, plant diameter 1400mm and height 2300mm with maximum operating pressure 3.5 Kg/Sqcm at Chandan complete all as specified and directed.
Servicing of water filtration plant of capacity 1000 cum/day, for treatment of water including multigrade sand filter, activated carbon filter, raw water feed pump including all connected items (at SMQ Pump House) complete all as specified and directed.
S&F in replacement CPVC Gate valve/Check valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 20mm bore pipe line including taking down old unserviceable complete all as specified and directed.
S&F in replacement CPVC Gate valve/Check valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 25mm bore pipe line including taking down old unserviceable complete all as specified and directed.
S&F in replacement CPVC Gate valve/Check valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 32mm bore pipe line including taking down old unserviceable complete all as specified and directed.
SANJOLI CONSTRUCTION COMPANY
JAI ENGINEERING COMPANY
M/s Ramesh & Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .