Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | ₹32.3 L Quoted ₹34.6 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹36.4 L+₹1.7 L (4.94%)Rejected-Finance | ₹36.4 L+₹1.7 L (4.94%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹38.7 L+₹4.0 L (11.7%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹38.7 L+₹4.0 L (11.7%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹39.7 L+₹5.1 L (14.7%)Rejected-Finance | ₹39.7 L+₹5.1 L (14.7%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹42.0 L+₹7.3 L (21.2%)Rejected-Finance | ₹42.0 L+₹7.3 L (21.2%) | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | Nitika electricals and engineers works L1 | M/S KALSI ENGINEERS AND CONTRACTORS L6 | M/S DC CONSTRUCTIONS L4 | JCC ENGINEERS PRIVATE LIMITED L3 | PROACH ASSOCIATES BUILDERS & ENGINEERS L2 | M/S J S ENGINEERS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out incl. taking out old unserviceable cable complete all as specified and directed. | 1,250 | Cum | 100 ₹1,25,000 | 120 ₹1,50,000 | 120 ₹1,50,000 | 80 ₹1,00,000 Lowest | 98 ₹1,22,500 | 120 ₹1,50,000 |
| 2.00 | Returning, filling in. including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed. | 780 | Cum | 20 ₹15,600 | 20 ₹15,600 | 100 ₹78,000 | 25 ₹19,500 | 20 ₹15,600 | 10 ₹7,800 Lowest |
| 3.00 | Removing excavated surplus soil to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 470 | Cum | 40 ₹18,800 | 20 ₹9,400 | 80 ₹37,600 | 40 ₹18,800 | 20 ₹9,400 | 5 ₹2,350 Lowest |
| 4.00 | M & L for Sand cushioning to under ground cable laid in trenches for laying of LT UG cable 8 cm depth before laying the cable and 15 Cm after laying and punned down to depth of 10 cm as per MES SSR Part -I ( 2009) complete all as specified and directed. | 420 | Cum | 300 ₹1,26,000 | 200 ₹84,000 Lowest | 300 ₹1,26,000 | 300 ₹1,26,000 | 650 ₹2,73,000 | 270 ₹1,13,400 |
| 5.00 | M & L for Brick covering abutting each other with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat all complete all as specified and directed. | 34,000 | Each | 5 ₹1,70,000 Lowest | 5 ₹1,70,000 Lowest | 5 ₹1,70,000 Lowest | 5 ₹1,70,000 Lowest | 5 ₹1,70,000 Lowest | 5 ₹1,70,000 Lowest |
| 6.00 | M & L for Old Brick covering abutting each other with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ obtained from excavation complete all as specified and directed. | 9,000 | Each | 1 ₹9,000 | 1 ₹9,000 | 5 ₹45,000 | 5 ₹45,000 | 1 ₹9,000 | 0.5 ₹4,500 Lowest |
| 7.00 | Supply, laying, jointing and testing in repair XLPE cable insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified and directed. | 150 | RM | 1,600 ₹2,40,000 Lowest | 1,800 ₹2,70,000 | 1,600 ₹2,40,000 Lowest | 1,756 ₹2,63,400 | 1,980 ₹2,97,000 | 1,840 ₹2,76,000 |
| 8.00 | Supply, laying, jointing and testing in repair XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 240 Sqmm 3.5core, complete all as specified and directed | 400 | RM | 1,000 ₹4,00,000 Lowest | 1,000 ₹4,00,000 Lowest | 1,300 ₹5,20,000 | 1,416 ₹5,66,400 | 1,160 ₹4,64,000 | 1,490 ₹5,96,000 |
| 9.00 | Supply, laying, jointing and testing in repair XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 185 Sqmm 3.5 core, complete all as specified and directed | 300 | RM | 1,050 ₹3,15,000 | 1,300 ₹3,90,000 | 1,000 ₹3,00,000 | 1,111 ₹3,33,300 | 940 ₹2,82,000 Lowest | 1,100 ₹3,30,000 |
| 10.00 | Supply, laying, jointing and testing in repair XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 150 Sqmm 3.5 core, complete all as specified and directed | 100 | RM | 950 ₹95,000 | 1,200 ₹1,20,000 | 800 ₹80,000 | 878 ₹87,800 | 790 ₹79,000 Lowest | 925 ₹92,500 |
Tender Value
₹50.0 L
EMD Value
₹99,940
Closing Date
17 Jun 2026, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR AND REPLACEMENT OF LT CABLES AND CONNECTING ITEMS AT VARIOUS LOCATION UNDER GE NAGROTA
2026_MES_765021_1
CANO GEN/TOKEN-16/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NAGROTA
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹99,940
Yes
29 Aug 2026
26 May 2026
22 Jun 2026
26 May 2026
17 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out incl. taking out old unserviceable cable complete all as specified and directed. | 1,250 | Cum | - | - |
| 2 | Returning, filling in. including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed. | 780 | Cum | - | - |
| 3 | Removing excavated surplus soil to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 470 | Cum | - | - |
| 4 | M & L for Sand cushioning to under ground cable laid in trenches for laying of LT UG cable 8 cm depth before laying the cable and 15 Cm after laying and punned down to depth of 10 cm as per MES SSR Part -I ( 2009) complete all as specified and directed. | 420 | Cum | - | - |
| 5 | M & L for Brick covering abutting each other with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat all complete all as specified and directed. | 34,000 | Each | - | - |
| 6 | M & L for Old Brick covering abutting each other with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ obtained from excavation complete all as specified and directed. | 9,000 | Each | - | - |
| 7 | Supply, laying, jointing and testing in repair XLPE cable insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified and directed. | 150 | RM | - | - |
| 8 | Supply, laying, jointing and testing in repair XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 240 Sqmm 3.5core, complete all as specified and directed | 400 | RM | - | - |
| 9 | Supply, laying, jointing and testing in repair XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 185 Sqmm 3.5 core, complete all as specified and directed | 300 | RM | - | - |
| 10 | Supply, laying, jointing and testing in repair XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 150 Sqmm 3.5 core, complete all as specified and directed | 100 | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TENDER16.pdf
Tender Documents • 1.05 MB
BOQ_860030.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .