Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.9 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹17.3 L+₹45,955 (2.73%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L-2 | Rejected-Finance Being other than lowest. | |
| 3 | L-3₹18.4 L+₹1.6 L (9.54%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L-3 | Rejected-Finance Being other than lowest. | |
| 4 | L-4₹19.0 L+₹2.1 L (12.7%)Rejected-Finance H O 325 JAIPUR HOUSE AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L-4 | Rejected-Finance Being other than lowest. | |
| 5 | L-5₹19.5 L+₹2.6 L (15.6%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GEAFADMAREAAGRA
GEAFADMAREAAGRA
REPAIR MAINT OF ELECTRIC STORAGE HEATER GEYSERS AND ALLIED WORKS IN CAMP AREA UNDER GE AF ADM AREA AGRA
2020_MES_379780_1
8000-1826/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GEAFADMAREAAGRA
Class E Cat b ( i ) and for un enlisted firms docs as per NIT
8 documents required · 8 mandatory
₹500
GEAFADMAREAAGRA
₹40,000
Yes
20 Oct 2020
22 Sept 2020
12 Oct 2020
22 Sept 2020
10 Oct 2020
28 Sept 2020
60 days
Amount
S&F in replacement of existing U/S inner tank with new inner SS tank of storage type electric water heater of 25 ltr capacity complete with rubber gasket including necessary nuts, bolts and washers, including taking down by opening of all electric and water connections, re-assembling and re-fixing the same complete all as specified and directed. Note :- The tank shall be tested at site and shall be able to with stand requisite pressure. Necessary testing equipment shall be arranged by the contractor.
S&F in replacement of existing U/S inner tank with new inner SS tank of storage type electric water heater of 50 ltr capacity complete with rubber gasket including necessary nuts, bolts and washers, including taking down by opening of all electric and water connections, re-assembling and re-fixing the same complete all as specified and directed. Note :- The tank shall be tested at site and shall be able to with stand requisite pressure. Necessary testing equipment shall be arranged by the contractor.
S&F in replacement of existing U/S syphon assembly made out of SS of 25/ 35 ltr capacity as per sample including necessary studs screws and rubber gasket/ washers matching with existing/ new inner tank including taking down by opening of all electric and water connection, re-assembling and re-fixing the same complete all as specified and directed.
S&F in replacement of existing U/S syphon assembly made out of SS of 50 ltr capacity as per sample including necessary studs screws and rubber gasket/ washers matching with existing/ new inner tank including taking down by opening of all electric and water connection, re-assembling and re-fixing the same complete all as specified and directed.
S&F in replacement of existing U/S geyser outer body made out of MS sheet capacity 25 ltr as per sample duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including taking down by opening of all electric and water connections, re-assembling and re-fixing the same complete all as specified and directed.
S&F in replacement of existing U/S geyser outer body made out of MS sheet capacity 50 ltr as per sample duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including taking down by opening of all electric and water connections, re-assembling and re-fixing the same complete all as specified and directed.
S&F in replacement of existing U/S glass wool of 25 ltrs capacity storage type electric water heater including taking down by opening of all electric and water connection,re-assembling and re-fixing the same complete all as specified and directed.
S&F in replacement of geyser element 1.5 KW triangular/ round (as per approved sample) of ISI marked complete all as specified and directed.
S&F in replacement of geyser element 2.0 KW triangular/ round (as per approved sample) of ISI marked complete all as specified and directed.
S&F in replacement of PVC connection heavy duty having wire strengthened of size 15 mm dia 450 mm long with 2 Nos brass nuts and washers at both end complete all as specified and directed.
S&F in replacement of PVC insulated copper conductor 3 core flexible cable of size 40/ 0.0076 and its connection complete all as specified and directed.
S&F in replacement of thermostat adjustable type between 30 0C to 85 0C of ISI marked complete all as specified and directed.
S&F in replacement indicator lamp for geyser suitable for 25/ 50 ltrs capacity complete all as specified & directed.
De-scaling of storage type electric water heater of capacity 25 ltr after taking down the storage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly using requisite chemical, re-assembly and re-installation of storage type electric water heater complete all as specified & directed.
S&F in replacement fusible plug for 25/ 50 ltrs capacity geyser complete all as specified and directed.
S&F in replacement pressure release valve suitable for 25/ 50 ltrs capacity geyser complete all as specified and directed.
S&F in replacement drain plug brass with washer suitable for 25/ 50 ltrs capacity geysers complete all as specified and directed.
S&F in replacement of existing U/S steel water tubing 15 mm bore medium grade galvanised with all fittings and fixed complete to walls, ceiling or laid in floor complete all as specified & directed.
Cutting the existing GI tubing 15 mm bore in position for taking branch connection including insertion of tee equal and any other accessories as required at site complete all as specified & directed.
S&F anchor bolt 12 mm x 100 mm long complete all as specified & directed. Note:- Anchor bolt shall be grouted with hammer drill only.
S&F in replacement of existing U/S brass non return valve suitable for 25/ 50 ltr capacity storage type electric water heater of size 15 mm complete all as specified & directed.
S&F in replacement of U/S bottom cover plate of storage type electric water heater of capacity 25 ltr & fixed with MS screws complete all as specified & directed.
S&F in replacement of U/S bottom cover plate of storage type electric water heater of capacity 50 ltr & fixed with MS screws complete all as specified & directed.
S&F in replacement of U/S brass CP wall mixer of size 15 mm for mixing hot & cold water screwed down for iron pipe complete all as specified & directed.
M&L for scraping of old paint from old geysers of 25 Ltr/ 50Ltr capacity complete and applying two coats of synthetic enamel paint (white colour) and writing work such as MES No. etc with black paint upto 25 mm height complete all as specified & directed.
S&F in replacement existing U/S sheet metal single pole and neutral enclosures with socket, plug top complete with one single pole MCB of 20 Amp 240 V complete all as specified & directed.
S&F of plug top 3 pin suitable for metal clad box of MCB DB plug in socket, 240 Volts complete all as specified and directed.
S&F plug top 3 pin 15 Amp 240 Volts ISI marked complete all as specified and directed.
S&F MCB single pole 240 volts, 'C' curv of rating from 6 to 40 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specfied and directed.
S&F in replacament of existing U/S MCB SPN 240 volts, 'C' curv of rating from 6 to 40 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specfied and directed.
Taking down old unserviceable copper/ aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/ casings & caping complete, including fixture and fittings such as switches, ceiling roses, pendents holder, regulators, sockets and defective main switch/ DB/ MCB/ Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS in PVC concealed conduit having thickness not less than 1.8 mm with all fittings including MS pressed steel sunken box with 3 mm bakelite laminated sheet fixed with cadmium plated screws and washers suitable for 5 pin 15 amps socket outlet, including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to comman earth dolly complete all as specified and directed.
S&F switch piano flush type one way 15 Amps, SP 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type 230 volts complete all as specified and directed.
Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning of storage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed. Make :- Racold Etrno 2/ Havells Puro Plus 25 Ltrs/ Usha Aquagenie-25
M&L for replacement of existing U/S submain wiring with two single core PVC insulated unsheathed multistranded copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated unsheathed multistranded copper conductor FRLS cable green colour of size 6 sqmm as earth lead in PVC conduit medium grade complete all as specified and directed.
M&L for replacement of existing U/S submain wiring with two single core PVC insulated unsheathed multistranded copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated unsheathed multistranded copper conductor FRLS cable green colour of size 4 sqmm as earth lead in PVC conduit medium grade complete all as specified and directed.
Taking down existing unserviceable/ BER energy meter and deposting to MES store yard and S&F tamper proof electronic energy meter with backlite LCD with multi features digital type), single phase, 50 Hz AC, class of accuracy 1.0 opearting voltage 140 V to 300 V of rating 10- 60 Amps conforming to IS 133779 complete all as specified and directed.
S&F in replacament of existing U/S sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification. .
M&L for replacament of existing old U/S earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick, burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised iron wire 4 mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20 mm bore light grade with funnel and wire mesh, charcoal, salt and 40 mm thick precast PCC cover of 1:2:4, type B-1 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6 mm dia MS bar and angle iron 40 mm x 40 mm x 3 mm frame including earth work in soft/ loose soil, removal of surplus soil to a distance n.exc 50 m and connecting, testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed. Note: Excavation and earth work is deemed to be included in the rates quoted.
S&F in replacament of existing U/S sheet metal enclosures distribution boards, double door three phase 415 volts, 4 way vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following :- (a) MCB TPN 63 AMP AC 415 VOLTS - 01 No as incoming and 12 Nos MCB SP 40 Amps, C series. Note :- (i) The DB shall be VTPN series of Legand/ Seimens/ Schneider (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost. (iii) connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin/ bottle type thimble, properly crimped. (iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (vi) MCB's shall have a same make as of DB.
M&L for replacement of existing U/S meter box with polycarbonate meter box suitbale to accommodate one meter, including fixing of meter and making all connections and required wiring complete all as specified and directed.
S&F in replacement of MCCB 415 Volts, 50 Hz, 63 Amps 4 pole with rupturing capacity 16 KA including providing thimbles for out-going cables complete all as specified and directed.
S&F in replacement tube light fitting energy saving decorative LED batten type 20 watt (4 Feet), 230 volts, 6500 K energy efficient tube light fitting hughly durable surface mounted LED batten constructed of fire extruded aluminium/ CRCA housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/ PVC connector to light fittings complete all as specified and directed. Make:- Philips Cat Ref BN021C LED20S PSU CW GR S2/ Wipro Cat Ref LL20-281-XXX-65ALI/ Halonix Cat REf HLB-03-20-CW-AL-HL1. .
S&F in replacement of bldg secuirty light fitting energy saving high efficiency LED street light fitting 20/ 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length not less than 1.2 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed. Make: Philips Cat Ref BRP022 LED20CW MR S1 PSU GR/ Wipro Cat Ref LR02-291-XXX-57-XX/ Halonix Cat Ref HLSLD-09-25-CWL-R. .
M/s Sumer Associates
Industrial Traders
Rakesh kumar
jmd engineers
H.S.Kochhar n Sons
AGRA AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .