PROVN OF FIRE ALARM SYSTEM AND SMOKE DETECTION SYSTEM AT CERTAIN LOCATIONS AT AF STN FARIDABAD UNDER GE (AF) FARIDABAD
2026_MES_783604_1
CWE/GGN/FT-07/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Faridabad
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Faridabad
₹84,830
Yes
5 Sept 2026
10 Aug 2026
7 Sept 2026
10 Aug 2026
5 Sept 2026
28 Aug 2026
10 Aug 2026 - 24 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,Installation,Testing & Commissioning of 1 loop Analog Addressable fire Panel with following Features :-
Each loop shall have a capacity of minimum 250 addressable devices excluding 20% spare. Expandable upto 30loops with supporting CPU/CPUs & power supply installed in Panel Failure of one loop card shuld not fail other loop (Virtual/Dual loop cards not allowed) Inbuilt 6 NAC Port to power Hooter strobe Peer to peer Networkable, support distributed loop architecture and Provision for remote monitoring through mobile app on a cloud Automatic battery charger for 24V SMF batteries sufficient for 24 hours normal working and 30 mins for Alarm The unit should be UL listed and FM approved complete as per specifications all complete all as specified and directed. | 5 | Each | - | - |
| 2 | Supply,Installation,Testing & Commissioning of 2 loop Analog Addressable fire Panel with following Features :-
Each loop shall have a capacity of minimum 250 addressable devices excluding 20% spare. Expandable upto 30loops with supporting CPU/CPUs & power supply installed in Panel Failure of one loop card shuld not fail other loop (Virtual/Dual loop cards not allowed) Inbuilt 6 NAC Port to power Hooter strobe Peer to peer Networkable, support distributed loop architecture and Provision for remote monitoring through mobile app on a cloud Automatic battery charger for 24V SMF batteries sufficient for 24 hours normal working and 30 mins for Alarm The unit should be UL listed and FM approved complete as per specifications all complete complete all as specified and directed. | 1 | Each | - | - |
| 3 | Supply, installation, testing and commissioning of Active Repeater Panel with backlit Liquid Crystal Display & Reset, Silence & Acknowledge function, ZXR-A to connect all Control panel with all fittings & accessories.
The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed. | 2 | Each | - | - |
| 4 | Supply, installation, testing & Commissioning of Battery SMFLead acid 18AH 12 Volt complete all as specified and directed. | 22 | Each | - | - |
| 5 | Supply, Installation, Testing and Commissioning of Addressable Mulicriteria Detector (Heat cum Smoke), Address Switch to programme the modules,complete all as specified and directed. | 5 | Each | - | - |
| 6 | Supply, Installation, Testing & Commissioning of Addressable Muliti-sensor Detector (smoke & heat) with following features :-
Smoke Sensitivity min 0.5% obs/ft for detecting Grey smoke. Dual Thermistors for Thermal activation at 57 Deg C Field adjustable min 3 levels of Alarm Setting Addressing using basic hand tools Bicolor LED with 360 deg view.The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed. | 290 | Each | - | - |
| 7 | Supply, Installation, Testing & Commissioning of Isolator Module with following features Isolate short circuits with automatic resetting arrangement LED Blinking in normal state & get steady on activation Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed. | 17 | Each | - | - |
| 8 | Supply, Installation, Testing & Commissioning of Addressable Output Module for 3rd Party integration with followingm features Dual Pot. free contact rated 24v DC, 2A LED Blinking in normal state & get steady on activation Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed. | 5 | Each | - | - |
| 9 | Supply, Installation, Testing & Commissioning of Addressable Manual Call point with following features Bicolor LED monitor the heath status of the device LED Blinking in normal state & get steady on activation Test Key for manual testing Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed. | 20 | Each | - | - |
| 10 | Supply, Installation, Testing & Commissioning of Hooter cum Strobe with following features Sound level 80 dBA @ 3m for Audible annunciation Visual - 115cd flashing at 1 Hz Wall/Ceiling Mountable The unit should be UL listed complete as per specifications complete all as specified and directed. | 22 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_877980.xls
BOQ • 0.40 MB
TDFT07.pdf
Tender Documents • 1.00 MB
FT07TDCorr.pdf
PDF • 0.42 MB
FT07datecorr.pdf
PDF • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].