Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹9.9 LAccepted-AOC SAI VARENYA PARK VIEW FLAT NO 110 GROUND FLOOR 9TH MAIN 6TH CROSS TURAHALLI BANGALORE 560 061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹10.7 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹11.1 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹12.1 LRejected-Finance NO 422 CHURCH STREET NEW THIPPASANDRA BANGALORE 560075 | BANGALORE | BANGALORE | KARNATAKA | 560075 | FORTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
27 Sept 2023, 6:00 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIRS TO CHLORONOME PLANTS RO PLANTS AT VARIOUS LOCATION UNDER GE AF MARATHAHALLI BANGALORE
2023_MES_616415_1
8647/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF MARATHAHALLI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹24,000
Yes
6 Nov 2023
30 Aug 2023
3 Oct 2023
30 Aug 2023
27 Sept 2023
13 Sept 2023
Amount
Servicing of water treatment plant (RO) filters by checking all parts, cleaning and backwashing of filter media of all units/membrane, arressting of leakages and checking quality of water and keeping the plant in serviceable condition to provide the acceptable quality standrad parameters as required all as specified by manufactures and directed. NOTE :- (a) Servicing shall be carried out through authorised OEM / or his authirised Rep and necessary certificate to be submitted as proof of having carried out the services. (b) Carry out water analysis test regarding chemicals & biological test report from Karnatka Govt. agencies as directed and test report shall be submitted. (c) Un serviceable spares which are required to be replaced shall be carried out and paid separetly under relevant items. (Make - Sathya Sai Aqua Pura Services (ASTE), M/s Aquionics (SDI & IAM)
Taking down unserviceable RO membrane from position, material and labour for fixing the new RO membrane 40X40 in its position checking for leakages, testing for RO plant capacity of 750/1000 LPH.(SDI and ASTE) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable RO membrane Housing from position, material and labour for fixing the new RO membrane Housing 40X40 Single in its position checking for leakages, testing for RO plant capacity of 750/1000 LPH.(SDI and ASTE) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable RO membrane Housing from position, material and labour for fixing the new RO membrane Housing 40X40 double in its position checking for leakages, testing for RO plant capacity of 750/1000 LPH.(SDI and ASTE) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable RO membrane from position, material and labour for fixing the new RO membrane 80X40 in its position checking for leakages, testing for RO plant capacity of 750/1000 LPH.( Vayu Vihar) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable RO membrane housing from position, material and labour for fixing the new RO membrane housing 80X40 in its position checking for leakages, testing for RO plant capacity of 750/1000 LPH.( Vayu Vihar) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable RO Dosing Pump from position, material and labour with all fittings & fixtures, electrical connections for fixing the new Dosing Pump checking for leakages, testing for RO plant capacity of 750/1000 LPH complete all as specified and directed.( Vayu Vihar, SDI, ASTE) (Make - Edose )
Taking down unserviceable RO UV Lamp from position, material and labour for fixing the new UV Lamp checking for leakages, testing for RO plant capacity of 750/1000 LPH complete all as specified and directed. ( Vayu Vihar, SDI, ASTE) (Make - Alpha )
Taking down unserviceable RO Water Softner Vessel from position, material and labour, fixing the new Water Softner Vessel, checking for leakages, testing for RO plant capacity of 750/1000 LPH.( SDI, ASTE) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable RO Multi-Port Valve from position, material and labour, fixing the new Multi-Port Valve, checking for leakages, testing for RO plant capacity of 750/1000 LPH.( SDI, ASTE) (Make - UKL /ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable Carbon sand of 10 Kg bag from position, material and labour, fixing the new Carbon sand checking for leakages, testing for RO plant capacity of 750/1000 LPH.( SDI, ASTE) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable resin 5 Kg bag from position, material and labour, fixing the new salt softner checking for leakages, testing for RO plant capacity of 750/1000 LPH.( SDI, ASTE) (Make- ION Exchange / Aquionics India / Lexpure)
Taking down unserviceable flow gauge from position, material and labour, fixing the new flow gauge checking for leakages, testing for RO plant capacity of 750/1000 LPH.( Vayu Vihar, SDI, ASTE) (Make- Asta rota meter )
Taking down unserviceable pressure gauge from position, material and labour, fixing the new pressure gauge checking for leakages, testing for RO plant capacity of 750/1000 LPH.( Vayu Vihar, SDI complete all as specified and directed, ASTE) (Make - Ionix )
Taking down unserviceable electonic float switch from position, material and labour, fixing the new electonic float switch checking for leakages, testing for RO plant capacity of 750/1000 LPH complete all as specified and directed.( Vayu Vihar, SDI, ASTE) (Make - Ampereus )
Taking down unserviceabl low pressure/ High pressure switch from position, material and labour, fixing the new low pressure/ High pressure switch checking for leakages, testing for RO plant capacity of 750/1000 LPH complete all as specified and directed.( Vayu Vihar, SDI, ASTE) (Make - Fdit electric )
Taking down unserviceable RO Spun from position, material and labour for fixing the new RO big Spun in its position checking for leakages, testing for RO Filter complete all as specified and directed.( IAM ,AKASH VIHAR and GE Office) (Make- ION Exchange / Aquionics India / Lexpure/KENT)
Supply and add PH correction liquid 5 ltrs to maintain correction to maintain the plant complete all as specified and directed (Make - Scale check )
Supply and add Anti scale liquid 5 ltrs to maintain correction to maintain the plalnt complete all as specified and directed (Make - Scale check )
Taking down old u/s RO/ Chlorine Dosing supply hose pipe supply and fix new RO/Chlorine Dosing supply hoses with required fittings and fixtures all as specified and directed.( SDI,Vayu Vihar, Visha Vihar, ASTE, Akash Vihar) (Make - Aqua )
Material and labour for Disconnecting the multi stage pump 1 HP from position, strip opening the motor, taking out the burnt copper winding wire from slots, cleaning the slots, rewinding with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional and checking the winding leak proof, refixing the pump set with proper alignment , connecting up the electric connections testing & commissioning complete. Note:- Rate deemed to be inclusive of replacement of worn out sleeves & bearings.
Material and labour for Disconnecting the Raw water pump 1 HP from position, strip opening the motor, taking out the burnt copper winding wire from slots, cleaning the slots, rewinding with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional and checking the winding leak proof, refixing the pump set with proper alignment , connecting up the electric connections testing & commissioning complete. Note:- Rate deemed to be inclusive of replacement of worn out sleeves & bearings.
Taking down unserviceable Domestic RO membrane from position, material and labour for fixing the new RO membrane 25 LPH in its position checking for leakages, testing for RO plant capacity.( IAM ,AKASH VIHAR and GE Office) (Make - HJC /KENT/AQUAGUARD)
Taking down unserviceable RO In Line Filters from position, material and labour for fixing the new RO In Line Filters in its position checking for leakages, testing for RO Filter capacity.( IAM ,AKASH VIHAR and GE Office) (Make - Lexpure /KENT)
Taking down unserviceable RO Spun from position, material and labour for fixing the new RO Spun 25 lph in its position checking for leakages, testing for RO Filter.( IAM ,AKASH VIHAR and GE Office) (Make - Lexpure /KENT/AQUAGUARD)
Taking down unserviceable RO motor from position, material and labour for fixing the new motor 25 LPH in its position checking for leakages, testing for RO . ( IAM ,AKASH VIHAR and GE Office) (Make - Lexpure/KENT/AQUAGUARD )
Taking down unserviceable RO UV lamp from position, material and labour for fixing the new UV lamp 25 LPH in its position checking for leakages, testing for RO Filter.( IAM ,AKASH VIHAR and GE Office) (Make - Lexpure/KENT/AQUAGUARD )
Taking down unserviceable RO CTO Filter from position, material and labour for fixing the new CTO Filter in its position checking for leakages, testing for RO .( IAM ,AKASH VIHAR and GE Office) (Make - Lexpure/KENT/AQUAGUARD )
M/S Jaiprakash Electrical and Engineering Works
GKR and CO
Siddivinayaka Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .