| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC HARIPUSHPA APARTMENT BUILDING NO E 1 FLAT NO 01 REST CAMP ROAD DEOLALI CAMP 422 401 | DEOLALI CAMP | NASHIK | MAHARASHTRA | 422401 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹6.5 L+₹66,961 (11.4%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder |
Tender Value
₹10.9 L
EMD Value
₹21,800
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR - 79 OF 2019-20 PROVISION OF HT RING MAIN CIRCUIT AT MILITARY STATION FAZILKA (3RD CALL)
2020_MES_332310_3
CA NO. CWE SGNR - 79 OF 2019-20
Open Tender
Civil Works
Item Rate
120 days
ABOHAR
Class E
Category b(ii)
9 documents required · 9 mandatory
₹500
GE ABOHAR
₹21,800
Yes
23 Jul 2020
25 Jun 2020
18 Jul 2020
25 Jun 2020
16 Jul 2020
2 Jul 2020
60 days
Amount
Supply, laying, jointing, testing and commissioning PVC underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11 KV (11000 Volts) grade cross sectional area 95 Sqmm 3 core laid in trenches / ducts / through pipes / in floors / alongwith poles etc. complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft / loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge
M & L for sand cushioning with dry coarse sand for under ground cable 23cm thick, 8cm thik below the cable and 15cm thick after laying and punned to 18cm after laying the cable complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge
Supply and laying reinforced precast concrete cable cover, class HV, Type-I flat of size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing HT 11 KV outdoor type gang operated air break switch suitable for horizontal or vertical mounting fixed type mechanically operated amounted on insulator and steel frame out door type for vertical installation single break provided with locking arrangement top of MS channel HT post insulator 11 KV consisting of operating rod of 25mm dia GI pipe medium grade conforming to IS-1818 of 1972 complete with 12 insulators and of rating 200 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and errection for pre-stressed cement concrete poles 11 Mtrs long of cross section (152mm x 152mm at top and (152mm x 260mm) at bottom, Class-9 complying with requirement of IS-1678 of 1978 including making 30cm strip with two coats of white and black synthetic enamel paint upto 1.5 Mtrs height complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earth work and PCC shall be measured and paid for separately under respective item of Schedule)
End cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinken type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
End cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination cold shrinken type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for expulsion type lightning arrester complete with all fittings, tansmission class having discharge capacity of 65 KA suitable for 11 KV complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI medium grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engineer-in-Charge. Notes :- (i) GI wire upto DBs earth connection is included in this item. (ii) Outer edge of earth pit chamber shall be 1 metre away from the outer edge of PCC chamber. (iii) Water pipe shall be provided in slanting manner.
M & L earthing complete with galvanized iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 Mtr deep below the ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to the including GI strip 32mm x 6mm (upto the body of equipment) by means of GI bolts / nuts / washers, protected by 40mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt 15cm thick all around bottom and top 20mm bore GI light grade pipe for watering and including funnel, wiere mesh, RCC cover and frame, PCC (1:3:6) type C2 (using 20mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No. 3 of MES schedule Part - I complete all as specified and directed by Engineer-in-Charge. Note : The unit rate includes earthing lead and protection pipe upto 7.5 meter from top of the earth plate.
S&F for HT cable route indicator for showing of cable route with PCC work complete all as specified and directed by Engineer-in-Charge Note : PCC work shall be measured and paid for separately
Supplying and laying GI tubing light grade 80mm bore for cable protection including clamps, nuts, bolts etc. as required for fixing of poles / wall / laid in trenches / under the road etc. complete all as specified and directed by Engineer-in-Charge.
M & L danger notice plates made from mild steel sheeting at least 1.6mm thick having size of 250mm x 200mm and vitreous enamelled white with letters, figures and the conventional skull and bones in signal red colour on front size fixed with MS clamps bolts and nuts of approved size complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:2:4, type B1 using 20mm graded store aggregates in curbs / coping / bed plates including weathering, slightly rounded or champhered angles with necessary form work for pipe support finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:3:6, type C1 using 20mm graded store aggregate as in foundation filling and mass concrete for stay assembly etc. complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8, type D2 using 40mm graded store aggregate as in foundation filling and mass concrete for poles / struts etc. complete all as specified and directed by Engineer-in-Charge.
M&L for horizontal boring of boles including HDPE pipe 80mm bore laid under road crossing for passing of LT / HT cables in any type of soil strata by trenchless technology complete all as specified and directed by Engineer-in-Charge
M&L cross arms, bracing, stiffeners, supports, clamps and back plates fabricated from structural steel sections grade of Fe-290 (grade E-165) such as channel angle iroon, flat iron, nuts, bolts, washers, welding, bending cold / hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.
Construction of platform for transformer of size 2500mm x 2500mm x 1500mm with brick construction in cement mortar 1:4, 40mm thick plain cement concrete (1:2:4) type B-1 as in floors, over 150mm thick plain cement concrete (1:3:6) type C-2 as in foundation including brick masonary step on one side XPN jali (weight not less than 4 Kg / Sqm) fixed on 08 Nos. 1.5 Mtr height angle iron of size 50mm x 50mm x 6mm thick grouted in PCC bed block 1:2:4 type B-1 post and gate openable type with locking arrangement including steps made to access to the top of platform earth work in any type of soil, 10mm thick plastering in cement mortar 1:4 to brick masonary including surface with two coats of synthetic enamelled paint over a coat of primer and two coats of white wash on plastered surface complete all as specified and directed by Engineer-in-Charge.
Singla Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .