Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC ok | |
| 2 | L2₹32.4 L+₹56,377.41 (1.77%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
18 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bihta
GE (AF) Bihta PIN - 801103
IMPROVEMENT / UPGRADATION FOR LIVING IN ACCOMMODATION OF AIRMEN AT AF STN BIHTA
2022_MES_519807_1
8215/BHT/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BIHTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹80,000
Yes
6 Jul 2022
25 Apr 2022
23 May 2022
25 Apr 2022
18 May 2022
10 May 2022
60 days
Amount
Dismantling of stone stabs & tiles of any description or thickness in floor, apoms etc and bedded & pointed in cement moter and disposing off debris to a distance up to 250M all as directed.
Dismantling floor hearth or wall tilling incl cement mortar beding (but not backing) & stacking at site as directed and disposing of debris to distance upto 250M all as directed.
Demolition of brick work/stone boulder masonery built in cement mortar in any position
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness unreinforeced (below or above ground level)
Taking down cement plaster from brick/stone/concrete wall surfaced incl (skirting plaster) racking out joints hacking for key scrubbing down with water etc
M & L for 15 mm thick rendering in CM (1:6) on vertical surfaces of brick walls finished even and smooth without using extra cement.
M & L for 15 mm thick rendering in CM (1:4) on vertical surfaces of brick walls finished even and smooth without using extra cement with using water proofing compound (WPC will be measured and paid separately).
M & L for 5 mm thick rendering in CM (1:3) on ceiling surfaces of finished even and fair without using extra cement.
M&L new plastered surfaces of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of approaved wall care putty all as specified & as directed .
M&L for new plastered surfaces of walls applying two coat of cement base paint over a coat of alkali resistant priming complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed.
M&L for preparation of old surfaces of ceiling and applying two coats of white wash all as specified and directed.
M&L for complete removing of existing treatment of wall surfaces and applying two coat of cement base paint over a coat of alkali resistant priming complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of approaved wall care putty all as specified & as directed .
M&L for old painted wooden surfaces and applying one coat of synthetic enamel paint (ordinary tint) of any description, over 10 cm in width or girth, not otherwise described all as specified and directed.
M & L Granite 20 mm thk (Telephonic black) work (table rubbed and polished) in steps, jambs, pillars, window-cills, Wash basin platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
M&L Non skid ceremic tiles 7 to 8mm thk (square/ rectangular) area of each tile exc. 0.11 sqm but not exc. 0.18 sqm, in floors etc , set and jointed in neat cement sluury and pointed in white or coloured cement to match the coloured tiles including 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes.
M & L glazed ceramic coloured tiles of approved quality ISI marked (350 X 250 X 7 mm / 450 x 350 x 7 mm / 450 x 300 x 7 mm thick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles including 1:4 cement plaster 10 mm thick on brick work and concrete surface all as specified and directed.
S&F as in repairs PVC low/high level flushing cristern white 10 ltrs capacity incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl bracats fixed in repairs all as directed. Note Removing existing fluhing system of CI or any other quality incl brackets.
S & Fixed in repair bib tips cast copper ailoy with crutch or butterfly handle, half turn screwed down, screwed for iron pipe or for brass furrule and fixed for 15mm dia pipe fixed in repairs.
S & Fixed in repair stop valves cast copper alloy, scrawed down hgh pressure with crutch or butterfly handle half turn screwed both ends for iron pipe or union fixed in repair for 15 mm dia GI pipe.
S & Fixed in repair vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistem & fush pipe fixed in repairs incl P or S trap.
S&F in repair of Vitreous China urinals, half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing with brackets, flush pipe, grating and Union for discharge pipe complete all as directed.
S & Fixed in repair Vitreous chiana wash basin white oval type size 560x410 mm including , waste pipe and plug and porcelain stopper alongwith 32mm dia CP waste coupling and PVC waste pipe in repairs complete all as directed.
S & Fixed in repair Pillar taps fancy type cast copper alloy,half turn with capastan heads, chromium plated, screwed down high pressure , with or without lettered HOT or Cold with long screwed shanks and fly nuts , srewed for iron/ CPVC pipe and fixed 15 mm dia of pipe all as specified..
S & Fixed in Repair Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union
S & F PVC (SWR) floor trap 75 mm out let dia, plain with grating including jointing with solvent cement
Taking down GI pipe 15mm dia with connection
Taking down GI pipe 20mm dia with connection
Taking down GI pipe 25mm dia with connection
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Brick walls
Supplying and laying of 16 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / Ceiling or laying in floors complete all as specified.
Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / Ceiling or laying in floors complete all as specified.
Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / Ceiling or laying in floors complete all as specified.
Demolition & breaking up drain pipes (SWG, AC, RCC etc) set in CM int dia of pipe 75 mm with all fittings .
S/F PVC pipes (SWR) single socketed in any length with rubber ring joints laid in trenches or in floor for 75 mm dia pipe
S/F (SWR) junction single ( single T) equal or unequal 75 mm dia with acess door
S/F PVC (SWR) bend 75 mm dia
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cm 1:6
M&L cement concrete type 25 mm thick B1, 1:2:4 mix usisng 20mm graded stone aggregates as in levelling course in floor and roof tops etc
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed 20 mm thk in cm 1:6 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and wax polishing complete
M & L Marble work 18 to 20mm thick (table rubbed and polished) in floors for border work in kota stone flooring, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana white over 20 mm thick screed bed in cement mortar (1:6).
M & L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and wax polishing complete including 10 mm thick plasteing in cement mortar (1:4) as a backing etc all as specified and as directed.
Dismantling of old roof treatment of any thickness including plastering, concreter padding including brick tiles or terracing tiles and removed spoil/rubbish out side MD land. Note :- The surface shall be wired brushed and clean to receive the PCC/plastering.
M&L for rendering 10mm thick in CM 1:3 on concrete surfaces / slabs finished even and smooth without using extra cement with admixture of integral water proofing compound @ 3% by weight of cement for filling depressions if any to receive water proofing treatment (WPC shall be measured & paid seperately)
M&L for appling bitumen primer @0.30 Ltr/sqm evenly over plastered suface all as specified and directed.
S & F APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by complete all as specified
M & L 40mm thick brick tiles laid on cement mortar mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement over 20 mm thk screed bed of cement mortar in CM 1:4 with WPC @ 3% by weight of cement by weight of cement (Note :- WPC shall be measured and paid separatly)
Supply only integral water proofing compound
Closing bolt holes etc. with metal putty in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm self tapping screw, incl removing old tapping screw and all set in stiff white lead,
M & L Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surface
Taking down & refixing Shutters in same opening of any description exc 1 sq. m and n exc 2 sq. m each after easing and adjusting etc.
Taking down of chowkat with shutter without taking off shutters from the frame n exceeding 1.50 Sqm with shutters without taking off shutters from frame
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel Sqm tube & fixed in position as per manufacturer's instruction all as specified
S & F solid PVC Moulded Door shutter 28 to 30 mm thk stiles with partical board core with 2,4,6, raised panel design with 2 mm thk moulded PVC sheet on the front face and 2 mm thk plain colour pvc sheet on back face
S&F for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel and fixed.
S&FAluminium anodised barred tower bolt of extruded section 150mm long all as specified and as directed.
S&F extruded aluminium alloy handle fabricated type anodised100mm longall as specified and as directed.
S & F Aluminium powder coated anodised frame for ventilator incl joining cleats & rubber beading for fixing for glass, wire mesh etc.
Supply and Fixing sheet glass 3 mm thick frosted ordinary quality and glazing with oil putty or glazing pins/spring clips with steel frams all as specified and directed
S&F galvanized mild steel wire cloth with 0.56 mm nominal dia of wire and average width of aperture 1.18 mm all as specified and as directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. For 500 ltr cap tanks (Cleaning repairing, etc. measured separately)
S&F in repair 20 mm dia float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 15mm - 142 gms / 20mm -210 gms / 25mm - 455 gms /40 mm - 690 gms / 50 mm - 1240 gms).
S&F in repairs gun metal globe or gate valves of 20mm dia pipes with iron wheel head screwed both ends for iron pipe or for unions, fixed in repairs etc, complete all as specified and as directed
Taking down copper/aluminium point wiring (light, fan socket or power) complete fittings such as switches, sockets, ceiling rose, pendents, regulators etc complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed.
Taking down carefully unserviceable sub main wiring of any size and type including making good the disturbed surfaces of walls, ceilings etc including two coats of white /colour washing/ distempering etc to match the existing complete all as directed by EIC.
Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceilings etc including two coats of white/colour washing/ distempering etc to match the existing complete all as directed by EIC.
Material and Labour for wiring complete 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor drawn through and including rigid PVC conduit pipe on walls, surface on roofs and beam etc including PVC insulated copper earth continuity conductor 1.5 Sqmm cable connected to common earth dolly including steel terminal boxes made out of 1.6mm thick MS sheet concealed in walls with laminated sheet top cover 3mm thick for housing the switches, sockets regulators etc all as specified and directed for one switch/light/bell point controlled by one switch. (a) One light point or one fan point controlled by one switch with cable 1.5 sq mm.
(b) One bell/buzzer point controlled by one push button with cable 1.5 sq mm.
(c) One 2pin/3pin switch socket out let 5 amps on independent board. with cable 1.5 sq mm.
(d) One 5 Amps socket point on same board with other switches
All as per item No. 69(a) above but wiring complete with cable 2.5 Sqmm for 3 pin 15 A socket outlet on independent board .
Material and Labour for switch piano flush type 5A, SP one way.
Material and Labour for switch socket combination 3 pin 5 Amps & 2 pin 5 Amps multipurpose flush type.
Material and Labour for switch piano flush type single pole one way 15 Amps.
Material and Labour for socket outlet 3 pin 15/5 Amps flush type.
Material and Labour for bell push flush type 5 A SP 240 V.
Material and Labour for bell (Ding-Dong) 230 volts, single pole .
Material and Labour for ceiling rose 3 terminals.
Material and Labour for electronic fan regulator 120 w 2 module rotary step socket type suitable for ceiling fan 1200 mm sweep and taking down old u/s.
Supply and fixing LED Tube light fitting 1 x 22 W 220 V, AC Decorative box type with driver,, bipin holders, connector block etc.,including-1 No LED T8 tubular lamp with in built driver, complete with all accessories and including connecting up with 3 core copper conductor cableof suitable size between ceiling rose and fitting terminal complete including taking down old light fittings all as specified and as directed
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffusersoft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size and taking down old u/s complete all as specified and directed.
Supply and fixing exhaust fan, steel body AC single phase 230 V of size 300 MM sweep with blades and frame and lowers
S & F MCB SPN 6-32 Amps, 'C' series, 240 V complete incl making conections and taking down old u/s all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections and taking down old u/s all as specified and directed.
S & F Sheet metal enclosure SPN with a two pin and earth plug and socket complete with MCB SP 6-32 Amps including making good the disturbed surfaces to match the existing complete and taking down old u/s all as specified and directed. (for geysers)
Taking down Old U/S MCB DB SPN 8 Way, S & F MCB DB SPN 8 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
All as per ser item no. 85 here-in-before but SPN 12 way, 240 Volts complete all as specified.
Taking down Old Unserviceable MCCB DB TPN, Supply and fixing Powerline Vertical DB, Double door suitable for TP/FP MCCB SKB as incomer, 12 Way, 415volts, flush to wall including Removing & Reconnecting existing wires/Cables,gland,lugs,cutting on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
Taking down unserviceable 125 Amps MCCB and Supply & Fix MCCB TPN 415 Volts 125 Amps rating with breaking capacity of 16 kA,fixed thermal & magnetic setting complete with making all connections as specified and directed.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with two runs of 6 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
Taking down ceiling fan, / Exc fan ceiling cable end, dismantling blades and carry out minor repair and fixing of damaged parts like capacitor, bushes,bearings and screws etc required and keeping in safe custody of contractor up to re fixing in the same. All as directed by engr in charge.
For painting of ceiling fan/ Exc fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc (M&L)
Hanging only ceiling fan / Exc fan and connecting up including provision of cable from ceiling rose or connector to fan
M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth lead wire 4.0 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
M & L excavation in trenches in soft/loose soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with soft/loose soil not exc 25 cm thick in each layer complete as specified and as directed
M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed
S & L sub class burnt bricks for cable protection complete as specified as directed
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3½ core connected with suitable legs including taking out the existing unserviceable cable. NOTE FOR ITEM NO 100 to 102 :- the quoted rate deemed to be inclusive of necessary Joints, Lugs thimbles screws nuts bolts, washers and other tools and plants required at site to complete.
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 4 core connected with suitable legs including taking out the existing unserviceable cable
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core connected with suitable legs including taking out the existing unserviceable cable
Boring of holes under road ,pavement hard standing by trenchless technology using ultra sounding,technique including HDPE pipe 110 mm dia
M & L for GI tubing light grade 80mm with all accessories for cable protection fixed on poles/bldgs of laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed
M & L for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs of laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed
M & L for PCC 1:3:6 type C1 with 20mm graded stone aggregate in copping of poles/filling road cutting stays ,incl necessary form work all as specified and as directed
Taking down Old U/S MCB DB TPN 4 Way, S & F MCB DB TPN 4Way with 200 Amps rated busbar, Double door, 440 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
Taking down Old U/S MCB DB TPN 8 Way, S & F MCB DB TPN 8 Way with 200 Amps rated busbar, Double door, 440 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
MS JAGDAMBA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .