Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
12 Oct 2020, 6:00 pmClosed
GE (U) Chandimandir
GE (U) Chandimandir Chandimandir Cantt Panchkula (HR)
GE(U)/CHM-19/2020-21- REPAIR / MAINT OF DG SETS AT ELECTRICAL INSTALLATIONS UNDER GE (U) CHANDIMANDIR
2020_MES_377091_1
GE(U)/CHM-19/2020-21
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
Chandimandir Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (U) Chandimandir
₹50,000
Yes
21 Oct 2020
12 Sept 2020
14 Oct 2020
12 Sept 2020
12 Oct 2020
28 Sept 2020
Amount
Disconnecting and taking down the defective self starter of any make from the DG set, transporting to civil workshop dismantling the same to take out defective parts and repairing by replacement of carbon brushes, armature coil, field coil, bush, bearings and bendix pinion, clutch assembly and other related components, reassembling & shifting to original location, refixing on the DG set , making all connections and testing for smooth functioning complete all as directed for DG set of capacity 20 KVA to 30 KVA. Note :- Self starter of same type and capacity shall be arranged by the contractor and fixed at the DG set for the duration the original one is under repairs. Unit rate quoted will be deemed to include the expenditure for the same and no extra payment shall be made on this part.
All as per item No 1 above but capacity 100 KVA.
All as per item No 1 above but capacity 125 KVA.
All as per item No 1 above but capacity 166.25 KVA.
All as per item No 1 above but capacity 180 KVA.
All as per item No 1 above but capacity 200 KVA.
All as per item No 1 above but capacity 320 KVA.
Supply and replacement of ( AVR ) automatic voltage regulator Diode forward and reverse, rotating rectifier assembly, half wave phase controlled thyristor type, complete all as per existing type & size for DG set of capacity 100 kVA.
All as per item No 8 above but capacity 125 KVA.
All as per item No 8 above but capacity 180 KVA.
All as per item No 8 above but capacity 320 KVA.
Disconnecting and taking down the leaking radiator from DG set engine, transporation to civil workshop for repairs , cleaning the complete radiator for detecting the leakage and repairing the leaking portion (Tubes/fins/tank etc) by soldering/brazing ,cleaning of all water tube with suitable cleansing agent & water pressure & removing the complete sludge and dust from inside the tank, replacing worn out hose pipes & clamps etc, shifting & refixing at original site and testing for proper working complete all directed for the DG set with capacity 100kVA.
All as per item No 12 above but capacity 125 KVA.
All as per item No 12 above but capacity 180 KVA.
All as per item No 12 above but capacity 200 KVA.
All as per item No 12 above but capacity 320 KVA.
Disconnecting and taking down the defective dynamo from the DG set engine, shifting to civil workshop for repairs, strip opening to remove unserviceable parts , repairing by replacing of armature coil, carbon brush, field coil, clutch patti bearing, refixing magnetic steel laminates, replacing pole head and pole shoe, bearings of shaft ball/roller/sleeve type, and other related items of the assembly , re-assembling and refxing the same on original position and testing complete for the DG set of capacity 20/30 kVA.
All as per item No 17 above but 100/125 KVA.
All as per item No 17 above but 200/320 KVA.
M & L for opening the tappet covers of the engine of the DG set of capacity 20/30 KVA of any make and carry out repair works such as checking and adjustment of tappet clearance, cleaning piston and cylinder heads by removing carbon deposits , checking general condition of the engine, checking and adjustment of opearting parameters, checking and adjustment of fuel timings, checking and adjustment of fault warning system, checking & tightening of various fasteners and connections, refixing the tappet covers incl replacing the worn out gaskets/nuts/bolts/washers etc complete all as directed.
All as per item No 20 above but 100/125 KVA.
All as per item No 20 above but 166.25/180 KVA.
All as per item No 20 above but 200/320 KVA.
Servicing of DG Set 320 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves/Jakson, taking down worn out replaceable parts such as fuel filters (Primary and secondary), by pass filters, lube oil filters, air cleaner filters, water separators filters, lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts shall be measured and paid for saperately under respective items here in after. (ii) Servicing will be carried out by OEM or authorised agent as approved by GE.
Supply only the following items for 320 KVA capacity DG set :-
Fuel filter assembly with 'O' rings
Lube filter assembly with 'O' rings
Bypass filter assembly with 'O' rings
Water separator with 'O' rings.
All as per item No 24here in before but 200 KVA capacity DG set.
All as per item No 24 here in before but 180 KVA capacity DG set.
All as per item No 24 here in before but 166 .25KVA capacity DG set.
All as per item No 24 here in before but 125 KVA capacity DG set.
All as per item No 24 here in before but 100 KVA capacity DG set.
All as per item No 32 here in before but 20/30 KVA capacity DG set.
Supply only the following items for 20/30 KVA capacity DG set :-
Material and labour of overhauling of injecter nozzles including replacement of nozzles, washers, etc and pressure setting as required and replacement of timing shaft with coupling all as directed by Engineer-in-charge for DG sets of 320 KVA capacity.
All as per item No 33 above but 200 KVA.
All as per item No 33 above but 180 KVA.
All as per item No 33 above but 166.25 KVA.
All as per item No 33 above but 125 KVA.
All as per item No 33 above but 100 KVA.
All as per item No 33 above but 20/30 KVA.
Disconnecting and taking down the fuel pump from the DG engine, transporting to civil workshop and repair & calibration of FIP of DG Set including replacement of plungers, washer manifold, injection nozzles etc all as required and testing after refixing on engine and setting the rated RPM all as specified and directed for DG set of capacity 320 KVA.
All as per item No 40 above but 200 KVA.
All as per item No 40 above but 180 KVA.
All as per item No 40 above but 166.25 KVA.
All as per item No 40 above but 125 KVA.
All as per item No 40 above but 100 KVA.
All as per item No 40 above but 20/30 KVA.
M&L for draining out the engine oil from the sump, opening the sump cover cleaning properly to remove old oil stucked to the surfaces, replacing the worn out gaskets/nuts/bolts/washers & refixing the sump cover complete all as directed for 320 KVA capacity DG set engine complete all as directed.
All as per item No 47 here in before but 200 KVA capacity DG set.
All as per item No 47 here in before but 180 KVA capacity DG set.
All as per item No 47 here in before but 166.25 KVA capacity DG set.
All as per item No 47 here in before but 125 KVA capacity DG set.
All as per item No 47 here in before but 100 KVA capacity DG set.
All as per item No 47 here in before but 30 KVA capacity DG set.
All as per item No 47 here in before but 20 KVA capacity DG set.
Supply and filling engine oil grade 15W40 premium grade complete all as directed. Make :- Castrol/HP/Servo
Supply and filling distilled water in batteries for top up complete all as directed.
M&L for draining out old coolant from the engine radiators of DG Sets of any capacity and make, flushing the radiator tubes with distilled water and filling with new coolant, refixing the drain plug properly and filling the complete radiator with new pre mixed coolant complete all as specified and as directed.Make: Servo/HP/Castrol
Supply and fixing in repairs heavy duty copper cable battery leads (Red and black ) compete all as specified and as directed.
Supply and fixing in repairs heavy duty brass terminals (as per sample) suitable for battery terminals compete all as specified and as directed.
S & F in replacement four pole changeover switch on load type 415 volts 400 amps capacity in open execution Make- Havells/HPL/Standard
M & L for cleaning the in-built diesel tanks of 320 KVA capacity DG set by emptying the tank using suction pump of suitable capacity, washing the internal walls & bottom with diesel to remove any dust / deposits etc complete all as specified and as directed.
All as per item no 61 above but capacity 200 KVA.
All as per item no 61 above but capacity 180 KVA.
All as per item no 61 above but capacity 125 KVA.
All as per item no 61 above but capacity 30 KVA.
M&L for reparing the doors of sound proof encloser of 125 KVA to 320 KVA DG Set for proper closing and locking using new SS hinges/door handles/ in built locks complete all as per existing and as directed.
M&L for reparing the doors of sound proof encloser of 20 KVA to 100 KVA DG Set for proper closing and locking using new SS hinges/door handles/ in built locks complete all as per existing and as directed.
M & L for decoupling the alternator from the engine , taking down from the foundation, transportation to civil workshop, dismantling complete to take out the rotor assembly, properly cleaning of alternator /stator windings/bearings etc with blower & dry cloth, varnishing & drying up of the windings in suitable furnace to improve insulation value, greasing of the bearings with high quality grease, tightening of terminal connections incl replacing worn out sleeves/ nuts/bolts/washers etc, re-assembling complete, shifting back & refixing at original position, making perfect alignment with the engine and testing all as specified and as directed for the DG set of Capacity 320 KVA.
All as per item No 68 above but 166.25/180 KVA.
All as per item No 68 above but 100/125 KVA
All as per item No 68 above but 20/30 KVA.
S & F in replacement on load type change over switch, 200 Amp capacity, 4 pole, 415 volts, 50 Hz, in open execution suitable for mounting/fixing in existing panel board all as specified and as directed. Make: Havells/HPL/L&T/Schneider
Supply and replacing LED type indicator lamp red, yellow or blue complete all as specified and as directed.
Supply and replacing V belt set ( for fan & alternator) for 320 KVA DG set engine of make Kirloskar/CG/Cummins etc all as per existing complete all as specified and directed.
All as per item No 74 here in before but 200 KVA capacity DG set.
All as per item No 74 here in before but 180 KVA capacity DG set.
All as per item No 74 here in before but 166 KVA capacity DG set.
All as per item No 74 here in before but 125 KVA capacity DG set.
All as per item No 74 here in before but 100 KVA capacity DG set.
All as per item No 74 here in before but 30 KVA capacity DG set.
All as per item No 74 here in before but 20 KVA capacity DG set.
S & F in replacement digital type 3 phase ammeter/ voltmeter of size 96 x 96mm complete all as specified and as directed. Make : AE/ Schnieder/ L&T
S & F in replacement maintenance free lead acid sealed battery (SMF) 12 volts 180 Ah complete all as specified and as directed. Make : Exide/ TATA GREEN
S & F in replacement maintenance free lead acid sealed battery (SMF) 12 volts 120 Ah complete all as specified and as directed. Make : Exide/ TATA GREEN
Excavation in trenches in hard/ dense soil not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth for laying of pipes, cables, poles, poles stay and getting out including dressing/trimming sides and bottom complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, filling back in trenches complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
Supply and spreading clean dry sand in trenches for cushioning of LT UG cable protection (below, above and around the cable laid in trenches) complete all as specified and directed.
Supply and laying well burnt bricks, sub class 'B' bricks of size 230 mm x 115 mm x75 mm laid breath wise along length of cable in trenches for cable protection laid for UG cable complete all as specified and directed.
Taking out/ down existing damaged/ unserviceable/ for rerouting LT underground cable aluminum conductor form trenches, pipe, ducts, poles, above ground etc where fesible and economical, 1100 votls grade of any size, testing for serviceability of cable, cutting and segregating serviceable portion, removal of unserviceable cable including taking out of cable cover/pipe complete all as specified and directe.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 400 sqmm 3.5 core incl taking out the old unserviceable cable complete all as specified and as directed.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 300 sqmm 3.5 core incl taking out the old unserviceable cable complete all as specified and as directed.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 185 sqmm 3.5 core incl taking out the old unserviceable cable complete all as specified and as directed.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 120 sqmm 3.5 core incl taking out the old unserviceable cable complete all as specified and as directed.
M & L for disconnecting of burnt out cables from panels , cutting out the burnt out ends , making new end joints by supply and fixing new aluminium lugs/insulation tapes etc and reconnecting using new nuts/bolts/washer etc complete all as directed for LT underground armoured cables of size 240 to 400 sqmm 3.5 core.
All as per item No 95 above but 95 to 185 sqmm 3.5 core.
All as per item No 95 above but 25 to 70 sqmm 3.5 core.
S&F in replacement, MCCB, three pole,400 Amp 415 volts, 50 Hz breaking capacity not less than 36 kA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links, Ics = 100% of Icu complete all as specified and as directed. Make: ABB/Schneider/L&T/HPL
All as per item No 98 here-in-before but three pole, 250 Amp breaking capacity not less than 36 KA with adjustable thermal and fixed magnetic setting.
All as per item No 98 here-in-before but three pole, 100 Amp breaking capacity not less than 16 kA with adjustable thermal and fixed magnetic setting.
All as per item No 98 here-in-before but three pole, 63 Amp breaking capacity not less than 16 kA with adjustable thermal and fixed magnetic setting.
M& L for providing earthing complete with galvanised steel earth electrode plate of size 600x 600 x6 mm thick burried directly in ground in a earth pit not lessthan 2.25 mtr deep below ground level with the top edge of the earth plate at a depth not less than 1.5 mtr below ground level , connected to and including galvanised iron strip of size 32 x6 mm earth strip by means of bolts & nuts ,check nuts and washers and connected to earth test point connected to earth point / transformer /panel / feeder pillor box all as specified and directed by Engr-in-charge including necessary earth work in any type of soil ,disposal of surplus soil not exceeding 50 m ( the rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness , providing suitable size of GI pipe (medium grade) for watering ,funnel, wirmesh, PCC sconnected PCC chamber(1:3:6) type C1 , RCC pit cover , charcoal ,salt including provision of earth lead protected by 40 mm dia light grade GI pipe and 20 mm medium gradeGI pipe for watering complete all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of out door type LT feeder pillar distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel.
Srl Item No 103 Contd... These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit. The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. (b) Incoming MCCB four pole, 415 Volts, 50 HZ, 400 Amps, breaking capacity 50 KA with adjustable thermal and adjustable magnetic release with Ics = 100% Icu -01 Nos. Make:- L&T/Havells/ ABB/Schneider/Legrand. (c) Four pole on load type change over switch 400 Ams capacity in open execution 415 volt-01 No. (d) Out going MCCB four pole, 415 Volts, 50Hz, 100 Amps breaking capacity 36 KA with adjustable thermal and adjustable magnetic release with Ics = 100% Icu -03 No. Make:- L&T/Havells/ ABB/Schneider/Legrand. (e) MCCB four pole 415 Volts ,50 HZ, 160Amps, breaking capacity 25 KA adjustable thermal and adjustable magnetic release with Ics = 100% Icu - 03 Nos . Make:- Hansel/Siemens/GE Power/ABB/Schneider/Legrand/Rittal.
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded curshed stone aggregate in cooping to pedestal of poles including necessay from work, fair finished surface, chamfered or rounded edges complete all as specified and directed by Engr-in-Charge.
M&L plain cement concrete 1:3:6 type C-2 using 40 mm graded curshed stone aggregate in foundation filling & mass concrete for poles/struts/stays assebbly complete all as specified and directed by Engr-in-Charge.
M&L for writing of MES No in alphabet and number letters, size of letters not less than 3 cm length and 6 cm height with synthetic enemal paint complete all as specified and directed by Engr -in-charge. ( Note : Total Nos of letter not exceed 20 Nos)
Excavation in trenches in hard/ dense soil in post holes( or similar holes ) Each n exc 0.5 cum ,getting out ,returning ,filling in and ramming earth or broken rubble mixed with earth around , in layers not exceeding 25 cm ,watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
Taking down old / broken /damage cement sheet of any size in any location for DG Set/ LT Panel room for repair/ replacement of Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws complete all as specified and directed.
Taking down old / broken /damage cement sheet of any size in any location for DG Set/ LT Panel room for repair/ replacement of Pre -painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/clading to wall ,fixed with self tapping screws complete all as specified and directed
Taking down /removing old rusted/ craked MS tublar & connected work repair/replacement for steel work in tubular trusses incl special shaped washers etc complete using ERW or induction but welded tubes conforming to IS1161-1979 grade st 240 complete all as specified and directed
Taking down old rusted screws repair/ replacement MS screw bolts(machine made) with hexagonal or squire head at one end and other end screwd , tobe fitted with washers and one hexagonal or square nut ,length of bolt exc 5 cm but not exc 10 cm , with dia of neck 11 to 15 mm suitable for fixing base plate complete all as specified and directed
M&L plain cement concrete 1:3:6 type C-1 using 20 mm graded curshed stone aggregate in foundation filling & mass concrete for poles/struts/stays assebbly complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable LT ACB any type/ capacity supply ,installation, testing & commissioning new LT ACB of 800 Amps four pole mannual drawout microprocessor based ,415 volts,50Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar of suitable capacity complete all as included the quated rate all as specified and directed by Engr-in-charge
Taking down carefully copper/ aluminium submain wiring for taking credit removing from site and making good disturbed surface of walls, floors etc.
Supply and fixing submain wiring alongwith earth wire of sizes of FR PVC insulated copper conductor, single core cable in PVC conduit 2x4.0sqmm+ 1x4 sqmm earth wire complete are one run /RM all as specified and directed .
Supply and fixing non metalic PVC conduits of size 20 mm external dia including all tees, bends,elbows,reducers, bell mouth tube ends and fixing accessories such as couplers,lock nuts ,saddles pipe hooks etc
Supply and fixing sheet metal enclosures for DB,s 8 way for double door 240 volt when MCBs to be used,
Supply and fixing MCB SPN 16 to 32 A C-type 10 KA
Supply and fixing MCB SP 06 to 32 A C-type 10 KA
Supply and fixing MCB SP 06 to 32 A C-type 10 KA
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc.
One light point or one fan point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body
S & F fan regulator 230 V complete all as specified and directed.
S & F Lamp holder , PVC / Polycarbonate type with back plate suitable for batten fitting.
Supply and fix LED 20-22 watt integrated battern with inbuilt litheum ion battery, with efficiency more than 100 lumen per watt, with min 04 hours back up Make - Hallonix/Philips/Syska.
Supply and fix LED lamp invertor technology 9 watt with 4 hour back up with efficiency more than 100 lumens per watt with litheum ion battery. Make : Hallonix/Philips/Syska.
Note: Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit Revised in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
Vasudeva Trading Co.
ELECTROMAX OF INDIA
R D Bansal
POWER TECH ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .