Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | ₹4.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.9 LRejected-AOC | ₹4.9 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | K V CONSTRUCTIONS L2 | R. Marimuthu L1 |
|---|---|---|---|---|---|
| 1.00 | CC Road Cutting including labour charges etc., complete as directed by departmental officials. | 4 | Cum | 1,187.08 ₹4,748.32 | 1,183.58 ₹4,734.32 Lowest |
| 2.00 | Construction of Maintenance holes of different depths as per type design/drawing along sewer lines and provided with tight fitting FRC manhole frames and covers of 600 mm dia., of approved make and quality including supply and fixing of encapsulated PVC foot steps. The manhole shall be of brick work (with approved chamber class II bricks of size 9" X 43/8" x 23/4" in CM 1:3 and plastered with CM 1:3, 20mm thick inside and 12mm thick outside as per type design with foundation concrete 250mm thick in CM 1:4:8 using 40mm HBG. Benching and channeling should be provided in the manhole and suitable diameter pipes for House service connection (Not exceeding 6 1 Number. for each manhold) to be left in the Maintenance holes as directed by the Engineer in- charge. The rate shall include earthwork, backfilling, and removal of surplus earth and depositing within 500m, de-watering wherever necessary, barricading, provision of danger lights etc., complete as per standard specification and directed by the Department Engineer. For construction of Sewer works SRC cement has to be
upto 1.5m deep below GL Rectangular 0.75x1.20m inner size | 5 | Each | 27,006 ₹1,35,030 | 27,002.5 ₹1,35,012.5 Lowest |
| 3.00 | Replacement of Underground Utilities (PVC Pipe) damaged during earthwork excavation for pipe laying works including cost of additional earthwork excavation in all soil strata, including BT/CC road cutting, removal of slushy soil and replacing the pipeline with sound pipe, including supply and delivery of PVC pipes, couplers, jointing materials and required specials, cutting, conveying , laying, jointing and cost of refilling for the additional earthwork etc complete and as directed by the TWAD board officers.200mm Dia PVC Pipe (6KSC) | 175 | RM | 1,592.42 ₹2,78,673.5 | 1,588.92 ₹2,78,061 Lowest |
| 4.00Sub Total | |||||
| 5.00 | GST 18% | 1 | No | 75,321 ₹75,321 | 75,205 ₹75,205 Lowest |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
23 Feb 2026, 3:00 pmClosed
Commissioner
Tiruvannamalai City Municipal Corporation
Providing Under Ground Drainage System UGD and Distribution main line at Byepass road 5 th cross Ward No 21 in Tiruvannamalai City Municipal Corporation.
2026_MAWS_661926_1
7354/2025/E2
Open Tender
Civil Works
Works
30 days
Tiruvannamalai City Municipal Corporation
Refer Tender Notice
2 documents required · 2 mandatory
₹0
₹5,000
26 Aug 2026
20 Feb 2026
23 Feb 2026
20 Feb 2026
23 Feb 2026
20 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | CC Road Cutting including labour charges etc., complete as directed by departmental officials. | 4 | Cum | - | - |
| 2 | Construction of Maintenance holes of different depths as per type design/drawing along sewer lines and provided with tight fitting FRC manhole frames and covers of 600 mm dia., of approved make and quality including supply and fixing of encapsulated PVC foot steps. The manhole shall be of brick work (with approved chamber class II bricks of size 9" X 43/8" x 23/4" in CM 1:3 and plastered with CM 1:3, 20mm thick inside and 12mm thick outside as per type design with foundation concrete 250mm thick in CM 1:4:8 using 40mm HBG. Benching and channeling should be provided in the manhole and suitable diameter pipes for House service connection (Not exceeding 6 1 Number. for each manhold) to be left in the Maintenance holes as directed by the Engineer in- charge. The rate shall include earthwork, backfilling, and removal of surplus earth and depositing within 500m, de-watering wherever necessary, barricading, provision of danger lights etc., complete as per standard specification and directed by the Department Engineer. For construction of Sewer works SRC cement has to be
upto 1.5m deep below GL Rectangular 0.75x1.20m inner size | 5 | Each | - | - |
| 3 | Replacement of Underground Utilities (PVC Pipe) damaged during earthwork excavation for pipe laying works including cost of additional earthwork excavation in all soil strata, including BT/CC road cutting, removal of slushy soil and replacing the pipeline with sound pipe, including supply and delivery of PVC pipes, couplers, jointing materials and required specials, cutting, conveying , laying, jointing and cost of refilling for the additional earthwork etc complete and as directed by the TWAD board officers.200mm Dia PVC Pipe (6KSC) | 175 | RM | - | - |
| 4 | Sub Total | - | - | - | - |
| 5 | GST 18% | 1 | No | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
BOQ_794547.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].