Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC Due to lowest amount quoted | |
| 2 | L2₹32.2 L+₹5.9 L (22.7%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L2 | Rejected-Finance Higher amount quoted | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in required catagary |
Tender Value
Refer Docs
EMD Value
₹59,580
Closing Date
5 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE (A) Jaisalmer PIN-345001
REPAIR AND MAINT OF AC PLANTS AT MIL STN JAISALMER UNDER GE (A) JAISALMER
2022_MES_512383_1
84003
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (A) Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (A) Jaisalmer
₹59,580
Yes
17 Jun 2022
8 Mar 2022
7 Apr 2022
8 Mar 2022
5 Apr 2022
22 Mar 2022
60 days
Amount
Supply and charge refrigerant gas R-407 in AC plant, of any capacity complete all as specified & directed by Engineer-in-charge.
Opening end covers of condensor in and including cleaning of condenser 11 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
Opening end covers of condensor in and including cleaning of condenser 25 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
Opening end covers of chiller condensor in and including cleaning of condenser 25 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
Opening end covers of condensor in and including cleaning of condenser 36 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
Opening end covers of condensor in and including cleaning of condenser 38 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
Opening end covers of chiller condensor in and including cleaning of condenser 38 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
Supply and replacing of compressor oil suitable grade for compressor (6102/21) complete all as specified & directed by Engineer-in-charge
Supply and replacing of compressor oil suitable grade for compressor (model No : SZ 185S4RC) complete all as specified & directed by Engineer-in-charge
Servicing of AHU of 11/25 TR AC plant by cleaning with chemical solution as required at site complette all as specified & directed by Engineer-in-charge.
Servicing of AHU of 36/38 TR AC plant by cleaning with chemical solution as required at site complette all as specified & directed by Engineer-in-charge. Note : Servicing work to be carried out twice through out the contract period.
Disconnecting the electrical connection & taking down the burnt out motor of capacity 7.5/10 HP from AC Plant and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing guage including replacement of bearings & correcting minor defects, reassembling, incl any machinary works such as welding, grinding, tuning, polishing etc and transporting motor from workshop to site, reinstalled at site, reconnecting, testing checking of RPM using techometer and showing to the department and commissioning complete all as specified & directed by Engineer-in-charge.
All as per iem No 12 but 5 HP motor for pump set/ Compressor motor, 3 Phase, 450 Volts
All as per iem No 12 but of capacity 3 HP motor of cooling tower/ blower motor, 3 Phase, 450 Volts
S&F in repair V Belt A-47 type complete all as specified & directed by Engineer-in-charge. (Make : Fenner or equivalent approved by GE).
S&F in repair V Belt B-113 type complete all as specified & directed by Engineer-in-charge. (Make : Escon or equivalent approved by GE).
S&F in repair V Belt B -122 type complete all as specified & directed by Engineer-in-charge.
S&F in repair V Belt A 1200 A-46 poly F-plus type complete all as specified & directed by Engineer-in-charge.
S&F in repair V Belt A-24 type poly F-plus type complete all as specified & directed by Engineer-in-charge.
S&F in repair HP cut out Model 5 MP complete as per site all as specified & directed by Engineer-in-charge. (Make : Indfoss or equivalent approved by GE).
S&F in repair LP/HP cut out made of brass suitable for 25 TR complete all as specified & directed by Engineer-in-charge.
S&F in repair mouldling thermosate suitable for 36 TR plant AHU all as specified and directed by Engr-in-Charge.
Repair/replacement Electric Actuator model No R-981-R,24 V AC/DC suitable for 11 TR plant AHUall as per site directed by Engr-in-Charge.
Repair/replacement Electric Actuator suitable for 25 TR plant AHU model No MS8104F1010 220 volt complete all as per site directed by Engr-in-Charge.
Repair/replacement Electric Actuator model No NF24 A -S2 Make BELIMO for 36/38 TR plant AHU all as specified and directed by Engr-in-Charge.
S&F in repair of over load protector relay of existing range & size upto 7.5/10 HP at plant room complete all as specified & directed by Engineer-in-charge. (Make : L&T or equivalent approved by GE).
S&F in repair expansion valve suitable for 12.5 TR compressor capacity AC plant complete all as specified & directed by Engineer-in-charge.
S&F in repair,/water/discharge pressure gauge round type made out of brass with cyphon for AC plant 25/11/36 TR capacity complete all as specified & directed by Engineer-in-charge.
S&F in repair, temperature thermometer for 25/11/36 TR AC plant complete all as specified & directed by Engineer-in-charge.
S&F in repair, compressor suction/discharge valve 25 TR complete all as specified & directed by Engineer-in-charge.
S&F in repair hot water generator heating coil suitable for hot water generatr of capacity 45 KW Make : Emerald, each coil haing capacity of 5 KW (9 Nos) and of the same make as of original including testing and commissioning and making hot water generation plant fully functional to the satisfaction of JE/Engr-in-Charge complete.
S&F in repair hot water generator heating coil suitable for hot water generatr of capacity 24 KW Make : Emerald, each coil haing capacity of 4 KW (6 Nos) and of the same make as of original including testing and commissioning and making hot water generation plant fully functional to the satisfaction of JE/Engr-in-Charge complete.
S&F in repair hot water generator heating coil suitable for hot water generatr of capacity 30 KW Make : Emerald, each coil haing capacity of 5 KW (6 Nos) and of the same make as of original including testing and commissioning and making hot water generation plant fully functional to the satisfaction of JE/Engr-in-Charge complete.
S&F sprinkler with pvc pipe 40 mm 04 Nos and clamps nut bolt and all accessories complete for AC plant of 25 TR capacity of cooling tower complete all as specified & directed by Engineer-in-charge.
S&F sprinkler 80 mm dia with pvc pipe 50mm 04 Nos and clamps nut bolt and all accessories complete for AC plant of 25 TR capacity of cooling tower complete all as specified & directed by Engineer-in-charge.
S&F in repair, water pressure valve made out of brass for AC plant 25 TR capacity complete all as specified & directed by Engineer-in-charge.
S&F in repair, gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe, including provn of one union complete all as specified of size 50 mm bore pipe complete all as specified & directed by Engineer-in-charge. Make Upadhyay/Bir
All as per item no 37 but of size 40 mm dia
All as per item no 37 but of size 32 mm dia
All as per item no 37 but of size 25 mm dia
All as per item no 37 but of size 20 mm dia
S&F butterfly valve of size 100 mm dia pressure class water type with iron handle complete all as specified & directed by Engineer-in-charge.
All as per item no 42 above here-in-before but of size 80 mm dia
S&F in repair, digital ammeter ACCU. CLASS 0.5 complete all as specified & directed by Engineer-in-charge. Make AE/Schneider
S&F in repair, HRC fuse, round type, upto 16 Amps (Make :- L&T or equivalent as approved by GE) complete all as specified & directed by Engineer-in-charge.
S&F in repair, HRC fuse, DIN type fuse links type HN , Size 00, 125 Amps (Make :- L&T or equivalent as approved by GE) complete all as specified & directed by Engineer-in-charge.
S&F in repair, Contactor 70 Amp AC3 Rating, MNX 70 for complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T)
S&F in repair, Contactor 40 Amp AC3 Rating, MNX 40 for complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T)
S&F in repair, Contactor 32 Amp AC-3 rating, MNX 32 complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T)
S&F in repair, Contactor 25 Amp AC3 Rating, MNX 25 complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T)
S&F in repair, Contactor 18 Amp AC3 Rating, MNX 18 complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T)
S&F in repair, Contactor 12 Amp AC3 Rating, MNX 12 complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T)
S&F in repair, Contactor 9 Amp AC3 Rating, MNX 12 complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T)
S&F in repair, Overload relay range 12 A-18 A complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T).
S&F in repair, Overload relay range 14 - 23 Amps complete all as specified and directed by Engineer-in-charge. (Make: BCH/TC/L&T).
S&F in repair timer, 0-120 Sec suitable for panel of AC plant complete all as specified and directed by Engineer-in-charge. .
S&F MCB SP 6 to 32 Amp, 'C' curve, 10 KA complete all as specified and directed by Engineer-in-charge. (Make: BCH/C&S/L&T).
S&F MCB SPN 6 to 32 Amp 'C' curve, 10 KA complete all as specified and directed by Engineer-in-charge.
S&F MCB TP 25 to 63 Amps,'C' curve, 10 KA complete all as specified and directed by Engineer-in-charge.
S&F MCB TPN 32 Amp 10 KA complete all as specified and directed by Engineer-in-charge.
S&F MCB TPN 63 Amp, 'C' curve 10 KA complete all as specified and directed by Engineer-in-charge.
S&F MCCB TP 400 Amp 50 KA Make Havells/L&T/Scheneider complete all as specified and directed by Engineer-in-charge.
S&F MCCB FP 400 Amp 36 KA Make Havells/L&T/Scheneider complete all as specified and directed by Engineer-in-charge.
S&F MCCB TP 100 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F MCCB FP 250 Amps 36 KA complete all as specified and directed by Engineer-in-charge.
S&F MCCB FP 100 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F MCCB FP 160 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F MCCB FP 125 Amps 10 KA complete all as specified and directed by Engineer-in-charge.
S&F MCCB FP 100 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair, indicator lamp LED type complete all as specified and directed by Engineer-in-charge
S&F in repair, single phase preventor having five protection complete all as specified and directed by Engineer-in-charge. (Make: minilac/EAPL/Technica).
S&F in repair, push button switch 220 Volts, 15 Amps all as specified and directed by Engineer-in-charge
Dismantling and taking down unserviceable PCB assembly control AC plant 36/38 TR carefully without damaging any other electronic control system & S& F new PCB assembly alongwith display and software update cotrol for exising make Blue star Testing and cmmissioning complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 36/38 TR carefully without damaging any other electronic control system and repair/replacement of unserviceable battery,LED, transistors, capacitors, inductors, diodes, switches and software update control (blue star) making it all functional in all respect and refixing testing complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 11 TR carefully without damaging any other electronic control system & S& F new PCB assembly alongwith display and software update cotrol for existing make blue star Testing and cmmissioning complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 25 TR carefully without damaging any other electronic control system & S& F new PCB assembly alongwith display and software update cotrol for existing make blue star Testing and cmmissioning complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 25 TR carefully without damaging any other electronic control system and repair/replacement of U/serviceable battery,LED, transistors, capacitors, inductors, diodes, switches and software update control for existing make blue star making it all functional in all respect and refixing testing complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 11 TR carefully without damaging any other electronic control system and repair/replacement of U/serviceable battery,LED, transistors, capacitors, inductors, diodes, switches and software update control for existing make blue star making it all functional in all respect and refixing testing complete all as specified and directed by Engineer-in-charge.
S&F in repair, air release valve suitable for 11/25/36 TR capacity AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, drier filter for 36/38 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, drier filter for 25 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, drier filter for 11 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, water flow switch for 11 TR AC plant complete all as specified and directed by Engineer-in-charge . (Make :- as per exising or ISI mark)
S&F in repair, water flow switch for 25 TR AC plant model no. WFS 6000, 150 PSI 1000 C, 1" NPT,15A 250V complete as per site all as specified and directed by Engineer-in-charge . (Make :- as per exising or ISI mark)
S&F in repair, water flow switch for 36 TR AC plant as per site complete all as specified and directed by Engineer-in-charge . (Make :- as per exising or ISI mark)
S&F in repair, temperature sensor for 38 TR AC plant complete as per site all as specified and directed by Engineer-in-charge.
S&F in repair, temperature sensor for 11 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, temperature sensor for 25 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, temperature sensor for 36 TR AC plant complete as per site all as specified and directed by Engineer-in-charge.
S&F in repair, liquid line valve for 38 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair, liquid line valve for 25 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F renewal of fins of cooling tower of AC plant of 50 TR capacity and taking out old worn out fins complete in all respect all as specified &directed by Engineer-in -charge.
M&L for repair/cleaning and painting of housing of cooling tower of 11/25/36 TR capacity AC plant, including repair o axial flow fan with adjustable angle and motor, replacement of unserviceable /torn net complete all as specified and directed by Engr-in-Charge.
M&L for cross arms, bracings,supports, clamps and back plates fabricated from structural steel sections including nuts, bolts washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed by Engr-in-Charge.
Taking/dismantling of strainer of dia 100 mm with nut-bolts etc all as specified and directed by Engineer-in-Charge Make-Castle/Sant
S&F for Y-strainer of dia 100 mm with complete fittings, nut-bolts etc all as specified and directed by Engineer-in-Charge Make-Castle/Sant
Dismantling and taking down service tank (PVC 1000ltr cap ) and M&L for service tank of cap 1000 ltrs with all fittings and fixtures complete all as directed by engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 25x4mm means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point erminal all as specified or indicated including testing on completion.
S&F in replacement FRLS, 4 core 1.5 sqmm PVC insulated PVC sheathed multistranded copper conductor cable on the existing conduit.
S&F in replacement FRLS, 4 core 6 sqmm PVC insulated PVC sheathed multistranded copper conductor cable on the existing conduit.
S&F in repair copper tube of dia 3/4'' with 10 mm thick insulation complete all as specified and directed by Engineer-in-Charge.
S&F in repair copper tube of dia 1/2'' with 10 mm thick insulation complete all as specified and directed by Engineer-in-Charge.
Taking down the old unserviceable LT UG cable of size 240 sqmm x 3.5 core with aluminium lugs etc complete all as specified and directed at site. Note : Excavation and earth work,sand,pipe and stone patti will be measured and paid separately.
All as per ser item No 104 above here- in- before but size of 6 sqmm x 4 core
All as per ser item No 104 above here- in- before but size of 10 sqmm x 4 core
All as per ser item No 104 above here-in- before but size of 25 sqmm x 3.5 core
All as per ser item No 104 above here-in- before but size of 35 sqmm x 3.5 core
All as per ser item No 104 above here-in- before but size of 50 sqmm x 3.5 core
All as per ser item No 104 above here-in- before but size of 70 sqmm x 3.5 core
All as per ser item No 104 above here-in- before but size of 185 sqmm x 3.5 core
Supplying laying and fixing with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc jointing and testing LT XLPE insulated galvanized steel wire armored electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor of cross sectional area 240 sqmm 3.5 core
All as per ser item No 112 above here - in- before but size of 6 sqmm x 4 core
All as per ser item No 112 above here - in- before but size of 10 sqmm x 4 core
All as per ser item No 112 above here-in- before but size of 25 sqmm x 4.0 core
All as per ser item No 112 above here-in- before but size of 35 sqmm x 3.5 core
All as per ser item No 112 above here-in- before but size of 50 sqmm x 3.5 core
All as per ser item No 112 above here-in- before but size of 70 sqmm x 3.5 core
All as per ser item No 112 above here-in- before but size of 185 sqmm x 3.5 core
Supplying laying and fixing with the wall/beam/cable tray copper conductor of cross sectional area 16 Sqmm single core all as specified and directed by Engineer- in-charge.
Supplying laying and fixing with the wall/beam/cable tray copper conductor of cross sectional area 2.5 Sqmm X 4 core all as specified and directed by Engineer- in-charge.
Material and labour for taking down the 10/7.5 Capacity pump from base plate after disconnecting the all pipe lines and transporting (to & fro) workshop for repair, dismantling the complete pump and reassembling/re-fixing in original position, testing & commissioning complete all as specified & directed by Engineer-in-charge with the replacement of the followings:-.
Casing Ring
Impellar ring
Impellar
Coupling seal
Coupling rubber
Shaft/sleeve
Bearings for pump
Material and labour for taking down the 5 HP Capacity pump from base plate after disconnecting the all pipe lines and transporting (to & fro) workshop for repair, dismantling the complete pump and reassembling/re-fixing in original position, testing & commissioning complete all as specified & directed by Engineer-in-charge with the replacement of the followings:-.
Casing Ring
Impellar ring
Impellar
Coupling seal
Coupling rubber
Shaft/sleeve
Bearings for pump
Material and labour for taking down the 2/3 HP Capacity pump from base plate after disconnecting the all pipe lines and transporting (to & fro) workshop for repair, dismantling the complete pump and reassembling/re-fixing in original position, testing & commissioning complete all as specified & directed by Engineer-in-charge with the replacement of the followings:-.
Casing Ring
Impellar ring
Impellar
Coupling seal
Coupling rubber
Shaft/sleave
Bearings for pump
S&F in repair DOL on line starter max motor output at 415 v, 3 ph MK1 (7.5 hp) as per site complete as per site all as specified and directed by Engineer-in-charge . (Make :- as per exising or ISI mark)
S&F in repair Star delta starter max motor output at 415 v, 3 ph MK1 (15 hp) as per site complete as per site all as specified and directed by Engineer-in-charge . (Make :- as per exising or ISI mark)
M&L for taking out damaged/worn out chilled water piping insulation and supply and fix new chilled water piping (80/100) insulation with 10mm thick EPS (thermocole) pipe section fixed with hot bitumin and finished with two coats sand cement plaster and GI chicken wire mesh complete all as per existing and making good the disturbed surface complete all as specified and direted by Eng-in-charge
Taking up / down of 80 mm dia GI pipes including fitting from trenches/walls /floors and connections including fixing accessories complete all as specified and directed at site.
All as per ser item number 152 above here-in-before but of size 50 mm
All as per ser item number 152 above here-in-before but of size 40 mm
All as per ser item number 152 above here-in-before but of size 25 mm
All as per ser item number 152 above here-in-before but of size 20 mm
M&L in replacement of pipe galvanised iron 'Medium' class fixing on wall , floor etc complete including fitting of size 80mm
All as per ser item number 157 above here-in-before but of size 50 mm
All as per ser item number 157 above here-in-before but of size 40 mm
All as per ser item number 157 above here-in-before but of size 25 mm
All as per ser item number 157 above here-in-before but of size 20 mm
Taking down the old unserviceable butter fly valve of up to 100 mm dia from water mains/ lumn pipe complete all as specified and directed by Engineer Incharge
Taking down the unservicebale MCB SP/SPN/TP/TPN from panel complete all as specified and directed by Engineer Incharge
Taking down the unservicebale MCCB of any size from panel complete all as specified and directed by Engineer Incharge
Taking down the unservicebale strainer of size 100mm dia from water mains complete all as specified and directed by Engineer Incharge
Flint India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .