Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
24 Aug 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin 900120 CO 56 APO
Outsourcing of Services for Operation of equipments of Water Treatment Plant, raising main, distribution of water supply system and misc works at Nagtalao under AGE I Nagtalao
2020_MES_370102_1
3001/08/E3
Limited
Job Works
Works
30 days
AGE I Nagtalao
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
3 Sept 2020
18 Aug 2020
25 Aug 2020
18 Aug 2020
24 Aug 2020
19 Aug 2020
30 days
Amount
Manning and operation of Central Water treatment plant at Nagtalao continuously in 3 shifts of eight hours each (Each shift of 8 hours) a team of FGM-01 No & Mate -02 Nos including security of plant, cleaning of premises of installations, operation and smooth maintenance of the following Machinery/ Equipment :-(a) 0.50 HP electric driven motor with pump-2 Nos (b) 1.00 HP electric driven motor with pump-3 Nos (c) 2 HP electric driven motor with pump-3 No (d) 3 HP electric driven motor with pump-2 Nos (e) 7.50 HP electric driven motor, with pump -04 Nos, and electric panel board.-02 Nos (f) 10 HP motor electric driven centrifugal pumps-2 Nos (g) 20 HP electric driven motor with pump-2 Nos (h) Contractor will also ensure proper mixing of Alam / bleaching poweder/chlorine and will check daily at final distribution point i.e at service tanks or tap of direct supply random of the users. He will also maintain a register with details of PPM with the signature of the users, both in the morning and evening hours as directed by the Engr-in- charge. (j) Maintenance and operation of filter beds including back wash and as when required removal of sludge precipitate at bottom of clarifloculator by means of opening wash out sluice valve on daily basis etc all as directed by Engr-in-Charge. NOTE :-(i) Complete Plant in working condition shall be handed over to the contractor at the time of commencement of work and contractor has to return the same in working condition after completion of the contract period. (ii) Contractor will maintain all the installations and structures to maintain the hygienic condition inside installations and it premises. (iii) The following staff shall be deputed by the contractor in each shift on all days of week for a period of 11 months (FGM - 01 No & Mate - 02 Nos) (iv) Mainting the records such as log sheet, log book, Earth testing register of Panel boards, transformers, Payment of all employed staff and other installtion incl cleaning of installation premises and the bird proofing arrangement and installation daily as directed by Engineer-in-Charge, records shall be submitted in AGE E/M Office weekly.
Manning for distribution of water supply from OH tank to user end. The staff as mentioned will also carry out distribution of water supply by operating sluice valve, gate valves and like in institutional and MD Accn area from the location of WTP to main RCC OH tank and from RCC OH tanks to service tanks of all the users (Also it will be the duty of valve man to ensure availability of water to each of the end user by personally checking the water pressure and properly operating the valves as and when required) . The following staff shall be deputed by the contractor in each shift on all days of week for a period of 12 months. Valve man - 01 No in each shift for two shifts per day. i.e 0500 hrs to 1300 hrs and 1300 hrs to 2100 hrs.
Carrying out the following laboratory checks to the sample obtained from water treatment plant located at Nagtalao once in every ten days from any of the Government Engg College or any of the Govt recognized lab which is recognized by central water comission all as directed by Engr-in-Charge. 1. pH 2. Colour 3.Turbidity 4. odour 5. taste 6. total coliform 7. E. coli 8. total dissolved solids 9. Residual Chlorine
Supply and Testing of treated water by O-Tolidine (Reagent) solution for determination of PH value of chlorine in water. Note: Duty staff of contractor will collect sample of water from residual end and will show tested sample to Engr-in-charge every day for record.
Supply and mixing of Alum ( in water for water treatment as and when required qty as per turbidity of raw water during the filtration of water all as directed by Engr-in-charge.
Supply and mixing of liquid Calcium Hypochlorite in water having 60 % to 70 % available chlorine packed in 45 kg plastic drums for water treatment as when required qty to achieve desired value of residual chlorine present in water (PPM) or as per direction. Make: Declibac technologies (P) Ltd/Pottar & Watts/Brio Zing
Supply and mixing of bleaching powder in water for water treatment as when required qty to achieve desired value of residual chlorine present in water (PPM) or as per direction.
Narendra General Suppliers
King Corporation
Bhawna Emporium
Vishwas Enterprises
FSB Services
Ashapura suppliers & constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .