Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹24.0 LAdmitted-Finance H NO 2 460 SHIVKRUPA MANGAL OFFICE NEAR UPHALIVANCHEN TA HAVELI DISTRICT PUNE PIN NO 412202 | PUNE | PUNE | MAHARASHTRA | 412202 | -16.90% | ₹24.0 L | L1 | Admitted-Finance |
| 2 | L2₹24.5 L+₹46,209.37 (1.93%)Admitted-Finance | -15.30% | ₹24.5 L+₹46,209.37 (1.93%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee 102 R RESIDENCY PLOT 39 SEC 19 BEHIND HOTEL MALWAN ULWE NODE NAVI MUMBAI | NAVI MUMBAI | MAHARASHTRA | - | - | - | Not Admitted-Fee Fee not received |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
8 Jun 2026, 3:00 pmClosed
Director IISER Pune
IISER Pune Dr Homi Bhabha Road Pashan Pune 411008
Electrical renovation work for three Chemistry labs at IISER Pune
2026_IISRP_910947_1
06/IISER/Pune/20206-27
Open Tender
Electrical Works
Works
180 days
IISER Pune
As per NIT
3 documents required · 3 mandatory
₹1,180
Director IISER pune
₹68,000
17 Jun 2026
1 Jun 2026
9 Jun 2026
1 Jun 2026
8 Jun 2026
1 Jun 2026
Bidder Please note that, quoted rate are inclusive of tranportation, labour, royalties taxes etc. except GST. GST will be paid as Govt of India, rules and regulation.
PVC RACEWAYS ( Along the wall) DLP U- PVC adaptable trunking : Supply & installation of surface mounted DLP U- PVC adaptable trunking raceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with removable covers, complete with necessary bends, suitable sized junction boxes, internal angle, external angle, flat 90 degree angle , end caps and tees,minor civil works if any etc, Complete. (For every 1mtr distance cable tag has to be provided for each circuit in the raceways - as more that 1C FRLS copper wire is required for 1 Circuit) PVC RACEWAYS ( Along the wall), DLP U- PVC adaptable trunking . Size: 105x 50mm PVC Raceways for Power & Data with above specifications 105x 50mm PVC Raceways ( Approved make : MK Honeywell / Legrand )
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 module ( Approved make : MK Honeywell / Legrand )
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 module ( Approved make : MK Honeywell / Legrand )
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 module ( Approved make : MK Honeywell / Legrand )
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 63 A, 4P, 100 mA . ( Approved make : MK Honeywell / Legrand / Schindler )
Relaying of existing UTP 4 pair CAT 6 LAN Cable in surface/ recessed medium class PVC conduit as required.UTP 4 pair CAT 6 LAN Cable. Measurement will be done on actual relaying of UTP 4 pair CAT 6 LAN Cable. Removing, shifting, storage of cable / wires with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Reinstallaion of existing 150x 50 mm DLP trucking on surface incluidind removing, shifting, storage of all accessories of DLP PVC trunking. Measurement will be done on actual reinstallation of DLP PVC trunking. Removing, shifting, storage of DLP PVC trunking with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Supply and installation of joints for PVC DLP trunking ( 105 / 150 mm x 50 mm Size Existing DLP PVC trunking ). Make Legrand / MK.
Removing of exisiting armoured cable from surface/ cable tray. Shifting, store of cable in same campus is in scope of agency. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately. For DB cable / power cable / fume hood cables / fume hood communication cable / fire detector cable ( Upto 35 sqmm )
Supply, installation, testing and commissioning of Start-Stop switching station having following specification. Specifications a ) Standard Start Push button with NO contact B) Standard Stop Push button with NC contact c) Emergency stop push button with Mashrrom head, self holding mechanism, Red top and yellow base, d ) PVC enclosure box with termination entry on each wall which is suitable for PVC / SS gland , Size of enclouser box 150 mm ( W ) x 100 mm ( H ) x 50 mm ( D) minimum. , wall mounting / surface mounting. e ) all Switches, Push buttons and enclosure boxes should be clearly labeled as per site requirement and colour code for each should be followed. Approval for sample component , arragement, GA etc are required from IISER Pune authorities.
Supply of 6 core x 1.5 sqmm , copper conductor, armoured cable, 1.1 KV grade, FRLS cable , Make Polycab / finolex / RR. ( For fume hood / fresh air system of OG starter feeder to Push button station )
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 6 Core x 1.5 Sqmm Armoured Copper Cable.
Removing of exisiting DLP trucking upto 100x50mm with all accessories / switch / socket / cable / wires / Data cable etc. from surface/ wall / panel . Shifting, store of DLP PVC trunking in same campus is in scope of agency. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. ( Approved make : MK Honeywell / Legrand )
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C ( Approved make : Polycab / Finolex / RR Kabel )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire ( Approved make : Polycab / Finolex / RR Kabel )
LIGHT CIRCUIT WIRING : Wiring for circuit / submain wiring in concealed pipe below false ceiling (by chieseling the wall and covering with chicken mesh with rough plastering) / surface mounted. Including ISI mark PVC Conduit with 25mm DIa of 2mm thick with PVC insulated FRLS single core wires with colour code of following: 2 x 2.5 sqmm + 1 x2.5 sqmm earth wire. ( Approved make : Polycab / Finolex / RR Kabel )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire ( Approved make : Polycab / Finolex / RR Kabel )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire ( Approved make : Polycab / Finolex / RR Kabel )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire ( Approved make : Polycab / Finolex / RR Kabel )
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. ( Dismanted material should be handed over to IISER Pune ) Group C ( Approved make : Polycab / Finolex / RR Kebal )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 MM ( Approved make : Precision / Diamond / Modi )
16 AMP Switch: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as requiredincluding connections, as required. . 15/16 amp switch ( Approved make : MK Honeywell / Legrand )
Supplying and fixing following Modular socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required. . 6 Pin 15/16 amp socket outlet ( Approved make : MK Honeywell / Legrand )
POWER SWITCHES / SOCKETS on walls - G.I. BOX. : Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc, as required. ( The job includes cutting & chasing existing wall, fixing the box in position as required including rough plastering.) (In all the rooms, vertical drops of conduits and switch boxes shall be concealed in the wall). Boxes should be of same make as that of modular accessories. :6 Module
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 1/2 Module Box with faceplate & cover
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 4 Module Box with faceplate & cover
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 6 Module Box with faceplate & cover ( Approved make : MK Honeywell / Legrand )
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable ( Approved make : D link / Polycab / Legrand )
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays cross members with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays cross members with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. . Upto 35 sq. mm
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18 watts
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm
Relaying of existing 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated. Measurement will be done on actual relaying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated. Removing, shifting, storage of cable / wires with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Relaying of existing speaker cable Single pair, 2-core, 1.5 sqmm. Measurement will be done on actual relaying of speaker cable Single pair, 2-core, 1.5 sqmm. Removing, shifting, storage of cable / wires with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Refixing of existing Fire detector component / module including detector / Responsce indicator / MCP / Facult isolator / Hooter / Spk / PA on wall / celing / panel / DLP PVC trunking. Measurement will be done on actual reinstallation of componenets. Removing, shifting, storage of all types of fire detector and PA system's compnenet are in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unserviable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately. After installation all compentnet should be in working manner with existing Fire detector panel. Final sucessful testing will be scope of agency.
Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 4 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable.
Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 6 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable.
Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 16 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable.
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At field side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately. ( Approved Make : MK / Legrand )
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.64 MB
Tenderdocuments1.pdf
Tender Documents • 17.47 MB
BOQ_957383.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .