| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹42.4 L+₹1.9 L (4.69%)Rejected-Finance 2ND FLOOR SHAGUN PLAZA SHYAMPUR RISHIKESH DEHRADUN UTTARAKHAND | RISHIKESH | DEHRADUN | UTTARAKHAND | 249204 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹43.6 L+₹3.1 L (7.67%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹46.7 L+₹6.2 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹46.8 L+₹6.3 L (15.6%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
G SIVA CHANDRA KANTH GE (SOUTH) DELHI CANTT 10
Garrison Engineer South Delhi Cantt 110010
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS AT VRC KHYBER LINE IHQ OF MOD ARMY HQ DGIS CAMS 1 CBPO PLI 10 JAKLI AND IML UNDER AGE EM (S) OF GE(SOUTH) DELHI CANTT 10
2021_MES_490295_1
GE/DS-70/2021-22
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS AT VRC KHYBER LINE IHQ OF MOD ARMY HQ DGIS CAMS 1 CBPO PLI 10 JAKLI AND IML UNDER AGE EM (S) OF GE(SOUTH) DELHI CANTT 10
10 documents required · 10 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹99,980
Yes
14 Jan 2022
25 Nov 2021
25 Dec 2021
25 Nov 2021
23 Dec 2021
9 Dec 2021
26 Nov 2021 - 7 Dec 2021
60 days
Amount
Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Enigneer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints are VRC, Khyber Line, IHQ (MoD) Army Camp, DGIS, CAMS, 1 CBPO, PLI, 10 JAK LI and IML. Contractor shall provide minimum four tradesmen (electrician) to attend the complaints all the above areas in all working days between 0830Hrs to 1700Hrs including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7.The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here-in-after.
S&F in repairs of switch piano flush type 6 Amps SP one way complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of switch piano flush type 6 Amps SP 2-way complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs bell push, flush type 6 Amps complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of switch piano type 16 Amps SP one way complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of Angular lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of bell Ding dong type 230 volts single phase complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200 mm sweep complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of fan condenser 2.5 Mfd complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of fan condenser 3.15 Mfd complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of 4 pin holder suitable for 36/18 Watts 4 pin type CFL fitting as per site requirement complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs CFL 36 watts 4 pin type 6500 K, complete all as specified and directed by Enigneer-in-Charge.
S&F LED Glass Bulb 12 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/SK light fittings in replacement of old unsv CFL light of any watt complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs Comfortable wall light fitting suitable for LED Bulb B-22 Cap complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs Wall mounted LED Integrated Batten T5 20 Watt - 4Ft White, indoor decorative PVC extruded T5 LED battern-Integrated type complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs Wall mounted LED Integrated Batten T5 10 Watt-2 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type complete all as specified and directed by Enigneer-in-Charge.
S&F LED 5 Watt batten type fitting, indoor decorative aluminium extruded T-5 LED Battern-integrated type (1 Ft) in repairs of old unsv existing 11Watt CFL light fitting, complete all as specified and directed by Enigneer-in-Charge.
S&F LED Building security light fitting 40W on existing bracket in repairs of old unsv existing security light fitting any type complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm for any type of wiring as per site requirement complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs of PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and directed by Engineer-in-Charge.
Taking down of old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and directed by Enigneer-in-Charge. Note : Rewinding will be measured and paid separately under this Schedule.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required complete all as specified and directed by Enigneer-in-Charge. Note : Gun metal bush, clamp, shaft, rod, bearing and painting of fan with good quality of synthetic enameled paint and including lathe machine work if necessary to making a upper/lower sheet of fan will be measured under of this item only.
All same as per ser item No 26 but exhaust fan 230/300 mm sweep
S&F in repairs MCB DB SPN 8 Way double door type,(IP 43 Protection) flush mounting complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs MCCB 3 Pole 415V, Adjustable type, 125 Amps with breaking capacity 25 KA complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs for MCB SP 10 to 40 Amps 240 Volts, 10 KA, `C' curve, as per site requirement complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs for MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, as per site requirement complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs MCB TPN 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Enigneer-in-Charge.
M&L for sub main wire using FRLS insulated unsheathed mulitistrand copper conductor FRLS PVC cable 2 runs of size 6 Sqmm for phase and neutral and 6 Sqmm for earthing drawn through rigid PVC casing caping/PVC condute pipe not less than 25mm dia including taking down fixed on wall/ground/ceiling etc and making good the disturbed surface to same the joining surface with OBD/ Colour Wash/ White Wash and complete all as specified and directed by Engr-in-Charge. Note:- Phase should be Red/Yellow /Blue, neutral should be black and earthing wire should be green colour. Two run of cable for phase /neutral and one run of cable for earth incl casing caping / conduit pipe will be measured and paid as one unit length.
S&F in repairs of distribution board V-TPN 4 way for fixing MCCB 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting, complete all as specified and directed by Enigneer-in-Charge.
M&L for earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground in ground (earth pit plate kess than 2.5 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement complete all as specified and directed by Enigneer-in-Charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Enigneer-in-Charge.
Taking down carefully the old U/S Aluminium / Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Enigneer-in-Charge.
M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable drawn through existing concealed PVC conduit and including replacement of unserviceable pressed steel terminal boxes with Modular steel terminal boxes including white cover modular plate with frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm copper cable earth continuity wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one 5 Amp switch one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) complete all as specified and directed by Engineer-in-Charge. Notes :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
One light /fan/Bell point controlled by one way switch
One light point controlled by two 2-way switch 230 volts.
One 3 Pin socket outlet 5 Amps independent board
One 3 Pin socket outlet 5 Amps point on same board
One 3 Pin socket outlet, 15 Amps on independent board with cable 2.5 Sqmm for main current and 1.5 sqmm as earth wire as power point.
Taking down old energy unserviceable electric meters depositing to store complete all as specified and directed by Enigneer-in-Charge.
Fixing only serviceable electric energy meters, connecting with incoming/outgoing cable connections and testing on completion of work. Notes :- 1. Serviceable electric energy meter will be issued by department under Sch 'B' free for fixing only. 2. The contractor will maint the record of serial No/ meter reading / Date of replacement of each old Unserviceable / serviceable meter and submit to Engr-in-Charge.
S&F in repairs thermostat (9/11 Inch long) for any make of Geysers of capacity 25 Ltrs complete all as specified and directed by Enigneer-in-Charge.
S&F in repairs heating element 1.5 KW for any make of Geryser of capacity 25 Ltrs complete all as specified and directed by Enigneer-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
S. S. CONSTRUCTION CO.
verma enterprises
PD SHARMA AND SONS
M/s Adhikari construction co.
Chaudhary Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .