| 1 | L1₹9.9 LAccepted-AOC OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹10.1 L+₹6,711.01 (0.67%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹10.4 L+₹30,109.71 (2.99%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹10.5 L+₹43,037.51 (4.27%)Rejected-Finance | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹10.7 L+₹58,791.06 (5.84%)Rejected-Finance | L5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
27 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I DARJEELING
AGE I DARJEELING JALAPAHAR CANT DIST - DARJEELING
REPAIR/MAINTS OF LIGHTENING PROTECTION SYSTEM, GARDEN LIGHTS AND CONTROLLING DEVICES AT LEBONG UNDER AGE (I) DARJEELING
2023_MES_600035_1
9063/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LEBONG
AS PER NIT
7 documents required · 7 mandatory
₹500
AGE I DARJEELING
₹18,400
Yes
30 Jun 2023
1 Jun 2023
28 Jun 2023
1 Jun 2023
27 Jun 2023
15 Jun 2023
Amount
Taking down old existing air termination rod from building roof and keeping in safe custody for reuse or taken as sch of credit, complete all as per specified and as directed by Engineer-in-charge.
Taking down Aluminium strip 25 x 3.15 mm with saddles and keeping in safe custody for reuse or taken as sch of credit, complete all as per specified and as directed by Engineer-in-charge.
Taking down test point terminal block incl enclosure from building/walls and keeping in safe custody for reuse or taken as sch of credit, complete all as per specified and as directed by Engineer-in-charge.
Refixing of Air termination single pointed aluminium rod 12 mm dia and 300 mm long, complete all as per specified and as directed by Engineer-in-charge.
Refixing of Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors, complete all as per specified and as directed by Engineer-in-charge.
Refixing of test point terminal block made of gun metal or phosphorus bronze size including 3 Nos 8 mm dia 25 mm long hex. head screw, complete all as per specified and as directed by Engineer-in-charge.
M&L for fixing Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors, complete all as per specified and as directed by Engineer-in-charge.
M&L for Air termination single pointed aluminium rod 12 mm dia and 300 mm long, complete all as per specified and as directed by Engineer-in-charge.
M&L for test point terminal block made of gun metal or phosphorus bronze size including 3 Nos 8 mm dia 25 mm long hex. head screw, complete all as per specified and as directed by Engineer-in-charge.
M&L for fixing galvanised iron strip 32 x 6 mm burried in ground including taking down old unserviceable strip, complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5 m in depth for foundation etc. or for laying UG cable etc not exc. 10 sqm on plan and not exc. 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge.
Supply & Laying of old size fly-ash bricks laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
M&L for cutting existing road/hard standing not exc. 20 x 45 cm in width and depth, geting out excavated material for laying of cable for protection under GI pipe, returning filling and well ramming watering finish surface 10 cm from top using PCC 1:3:6 using 20 mm graded stone aggregate; including removing surplus soil complete all as per specified and as directed by Engineer-in-charge.
Supply, laying, jointing and testing of LT UG cable of size 10 Sqmm 2 Core, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured, multi-stranded aluminium conductor cable, laid in trenches / ducts or fixed to poles / walls or laid under roads / paths / drains / culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection incl cable route indicator, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note:- Excavation & earth work and pipe / sand / bricks shall be measured and paid for separately.
S&F in repair of 40mm dia GI tubes (light grade) galvanised with fittings, laid in trenches/wall/pole for protection of underground cable when crossing the road/fixing, complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of LED Garden light fitting 10 Watts, TURIN LED Bollard unique concept LED Bollard in IP 66 to ensure sustainable performance in all sections and aesthetics which keeps surrounding lively including driver unit etc including taking down old unserviceable garden light, complete all as per specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of LED Decorative Post top larten light fitting 40 Watts, IP65 protection and including driver unit etc and taking down old unsv any size/watt of Post top lartan light, complete all as per specified and as directed by Engineer-in-charge.
Supply & fix in replacement of street light fitting LED type 90 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit etc and including taking down old unserviceable street light, complete all as per specified and as directed by Engineer-in-charge.
Supply and fix in replacement of FRP looping box of size 155 x 210 x 95 mm (HWD) with 6 amps MCB provision and suitable connector for single/three phase connections loop in and out 10 to 16 sqmm 2 core aluminium armoured cable branch out 1.5 sqmm single core copper pvc insulated cable, enclosed in thermoplastic / polycarbonate enclosure which should be shock proof safe IP 66/67 thermoplastic metric size glands ,GI clamps made out of GI flat of size 32mm X 6mm channel including making connections and taking down old unserviceable box, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair/replacement of MCCB thermal magnetic, 100A, 25 KA, 4Pole, ies=ieu=100%, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair/replacement of MCCB thermal magnetic, 160A, 25 KA, 4Pole, ies=ieu=100%, complete all as per specified and as directed by Engineer-in-charge.
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip 32 x 6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 40 mm dia. light grade pipe and watering pipe shall be 20 mm bore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. NOTE : (i)The concrete pit shall be PCC 1:3:6 tye C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in liew of cast iron cover shown in electrical plate No. 3 of MES SSR Part-1 (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) Item includes the cost of 7.5 mtr length earth strip.
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern & etc including taking down old unserviceable cable, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair suitable PVC enclosure with front opening door with hinges and locking arrangement as in enclosure for test point terminal block of size (mm) 240X130X110mm, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair suitable FRP enclosure with front opening door with hinges and locking arrgement as in enclosure for street light /garden light pole junction box of size (min) connect 240X130X110 mm incl suitable cable entry gland and incl one no 6A MCB, din rail and connectors etc incl GI clamps made out of GI flat of size 32 mm X 6mm two nos duly fixed with nuts, bolts and washers, complete all as per specified and as directed by Engineer-in-charge.
Taking down old u/s PVC protection pipe and S&F steel tubing GI (light grade) 15mm dia, as in protection and passing of cable on pole incl 03 Nos MS clamps duly aluminium painted (shade as approved) with nuts bolts and washers complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-1 (20mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S TSHERING BHUTIA
SANJAY KAUSHIK
HIRA SINGH
Darjeeling Enterprises
M/S S. S CHETTRI AND SONS
GEETA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .