Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted | |
| 2 | L2₹29.4 L+₹43,851 (1.51%)Rejected-AOC NO 41 21 PERAMBUR BARRACKS ROAD PATTALAM CHENNAI 12 | 12 | L2 | Rejected-AOC second lowest | |
| 3 | L3₹30.2 L+₹1.3 L (4.36%)Rejected-AOC NO 1 A WING 3RD FLOOR PARSN MANERE ANNA SALAI CHENNAI 600 006 | CHENNAI | CHENNAI | TAMIL NADU | 600006 | L3 | Rejected-AOC Quoted Highest | |
| 4 | Not Admitted-Fee/PreQual/Technical 137 ANANTHALAKSHMI NAGAR SERVICE ROAD OPP TO SURAPET TOLL PLAZA SURAPET CHENNAI 600 066 | CHENNAI | CHENNAI | TAMIL NADU | 600066 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹29.5 L
EMD Value
₹1 L
Closing Date
31 Dec 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Additioal Commissioner (Prev.)
60 Rajaji Salai, Custom House, Chennai
Notice Inviting e-Tender (Re-Tender) for creation/installation of modular work station (Preventive) Customs Commissionerate, Custom House,Chennai-1.
2021_DREV_664449_1
S31A/72/2020-21-CHS
Open Tender
Miscellaneous Works
Item Rate
30 days
Room No. 212, Bonds Unit, 2nd floor Krishna Block
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1 L
Yes
21 Jan 2022
22 Dec 2021
1 Jan 2022
22 Dec 2021
31 Dec 2021
22 Dec 2021
22 Dec 2021 - 29 Dec 2021
60 days
Amount
Wood Works
Wooden Partition 5 ft height (Made from 50 x 25 mm aluminium section of 2 mm wall thickness covered with 19 mm BWR kit marine plywood on both side and laminated on both side with thick laminate of approved shade from ISI make up to 4 ft and above 4 ft to 5 ft 12mm toughned glass should be fixed with wooden mouldings properly polished.)
Wooden Working table of size 5L x 2.5W x 2.5H (Made from 19 mm BWR kit marine plywood laminated on both side with 1 mm laminate of approved shade from ISI make top should be 40 mm thick and having 1 set of drawer unit with set of 3 drawer with set locking arrangements with brass hardware.)
Wooden side Computer Table of size 3L x 1.5W x 2.5H (Made from 19 mm BWR kit marine plywood laminated on both side with 1 mm laminate of approved shade from ISI make top should be 40 mm thick and having 1 drawer with 1 shutter with full out keuboard tray with locking arrangements with brass hardware.)
Wooden working table of size 4L x 2W x 2.5H (Made from 19 mm BWR kit marine plywood laminated on both side with 1 mm laminate of approved shade from ISI make top should be 40 mm thick and having 1 set of drawer unit with set of 3 drawer with set locking arrangments with brass hardware.)
Wooden File Storage Units of Size 5L x 1.5W x 4H (Made from 19 mm BWR kit marine plywood laminated on both side with 1 mm laminate of approved shade from ISI make top should be 40 mm thick and having 2 shutters, 2 selves with locking arrangments with handles.)
Chairs
High Back Chair : Godrej model 7001 or equivalent seat and back padded with latex rubber foam and covered with approved cotton fabrics mounted on five legged heavy duty steal base powder coated with nylon wheels. The chair should have hydraulic mechanism for height adjustment and also provision for titling and revolving.
Medium Back Chair : Godrej model 7002 or equivalent seat and back padded with latex rubber foam and covered with approved cotton fabrics mounted on five legged heavy duty steal base powder coated with nylon wheels. The chair should have hydraulic mechanism for height adjustment and also provision for titling and revolving.
Vistors Chair : Godrej model 7003 or equivalent seat and back padded with latex rubber foam and covered with approved cotton fabrics mounted on 'S' type heavy duty one (1) inch tubular frame powder coated.
False Ceiling
2 x 2 feet grid armstrong tile with armstrong heavy duty channel.
Painting
Removing Dry or oil bund distemper water proofing cement paint by scrapping and preparing the surface smooth including necessary repair to scratches etc., providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. One or more coats. Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats.
Electrical
Wiring for light point / fan point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface / recessed steel / PVC conduit including dismantling as required.
Supplying and drawing 3 x 1.5 sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conducit / CMS as required.
Supplying and drawing 6 x 1.5 sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conducit / CMS as required.
Supplying and drawing 3 x 4 sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conducit / CMS as required.
Supplying and drawing 6 x 4 sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conducit / CMS as required.
Supplying and drawing 25 mm size of medium class PVC conduit along with accessories in surface / recessed including cutting the wall and making good the same in case of recessed conduit as reuired.
Supplying and drawing 2 run of cable of CAT 6 LAN cable from the terminal to the each work station.
Supplying and fixing of PVC cable management trunking of size 105 10 mm x 50 mm with cover on surface as required.
Supplying and fixing of wire / cable retaining clip for 105 x 50 mm PVC cable management system as required.
Supplying and fixing of flat angle for 105 x 50 mm PVC cable management system as required.
Supplying and fixing of flat junction for 105 x 50 mm PVC cable management system as required.
Supplying and fixing of 15/16 AMP one way anchor roma switch, modular plate & switch box including connections etc as required.
Supplying and fixing of 5/6 AMP 3 pin anchor roma socket, modular plate & switch box including connections etc as required.
Supplying and fixing RJ11 telephone anchor roma socket outlet, modular plate & switch box including connections etc as required.
Supplying and fixing RJ45 internet anchor roma socket outlet, modular plate & switch box including connections etc as required.
Supplying and fixing 3 module modular Anchor Roma frame and cover plate for two numbers data & one number telephone socket.
Supplying and fixing of 6 module Anchor Roma plate with two numbers 15 AMP switch with two numbers 15 AMP 3 pin international socket for raw power and similar one set of 6 modular Anchor Roma plate with two numbers 15 AMP switch with 2 numbers 15 AMP international socket for UPS power.
Supplying and fixing suitable size GI box with modular plate and cover infront on surface or in recess including providing and fixing 3 pin 25 AMP modular socket outlet with 25 AMP plug top and 32 AMP modular DP switch, connection, painting etc as required. (for Air Conditioner connection, switch and socket to be fixed separately in different location as per the directions.)
Supply, installation, testing and commissioning of optical type smoke detectors as required.
Supply, installation, testing and commissioning of response indicators above and below the false ceiling as required.
Supply and fixing 63 AMPS rating, four pole 415 Volts isolator in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supply and fixing 63 AMPS rating, four pole (3 phase and neutral) 415 Volts, residual current circuit breaker having a sensitivity current upto 300 milli amps in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supply and fixing "S"AMPS to 32 AMPS rating, 240/415 Volts, "C Series", miniature single pole circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
48 Watts 2 x 2 LED false ceiling lights.
IT CONNECTIONS
Providing end jack in CAT 6 wire for internet / intranet connections for all the tables.
Providing, fixing and connecting 24 Port Data Switch D-Link make.
Providing and fixing plate for 24 Port Switch.
Providing and fixing metal box with glass door to house then 24 Port Switch.
Dismentaling of existing old fittings / fixtures
Removing all the existing old wire, switch boards exposed electrical pipes, fans, light fitting and partition of 210 sq ft.
P Manickam and Co
Solar Designs Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .