Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹48.3 L
EMD Value
₹96,500
Closing Date
22 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
AS AND AS TO P216 AND GYMNASIUM AND SPORTS ARENA AT INS RAJALI ARAKKONAM
2025_MES_734266_2
8521E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer M NAS Arakkonam
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹96,500
Yes
12 Dec 2025
26 Nov 2025
24 Dec 2025
26 Nov 2025
22 Dec 2025
3 Dec 2025
Demolition of cement concrete of any description and in any position complete all as specified
Supply and fix in repairs stainless steel grating doom 100mm dia complete all as specified and as directed by Engr-in-charge.
M & L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and as directed by Engr-in-charge.
M&L for Providing padding cement concrete in roof kerbs or mud stops, rounded or chamfered on edges cement concrete C-0, 1:3:6 (12.5mm graded aggregate) with water proofing liquid complete all as specified and as directed. (Note: WPC shall be measured and paid separately)
M&L for 5 mm thick Screed bed or bedding layer in CM 1:4 with water proofing compound on surface to have a smooth surface for laying floor finishes complete all as specified and as directed by Engr-in-charge.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in two layers 10mm thick in CM 1:4 followed by 5mm thick CM 1:4 with approved WPC, finished even and fair.( WPC shall be measured and paid separately).
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minium 3mm thick reinforced with polyester non woven fabric (weight not less than 150 gms/ sqm) laid on primed surfaces with industrial bitumen 85/25, @ 1.20 Kg/Sqm over bitumen primer @ 0.5 litre/Sq.m. by gas flame torch application and cleaning surfaces, applying evenly a tack coat/primer of industrial bitumen 85/25 grade at the rate of 1.20kg/sqm over APP membrane complete all as specified and as directed by Engr-in-charge.
M & L for 2 coats Aluminium paint over Water Proofing Treatment complete all as specified and directed by Engineer in charge
Material and labour for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified .
M & L for preparation of newly plastered surfaces and applying wall care putty upto 1-2mm thick as required (Multipurpose mixer shall be used for uniform and propper mixing of putty) and applying two coats of emulsion weather coat white/coloured over a coat of exterior water proof primer by auto roller as per site requirement complete all as specified and directed as per manufacturer instruction. Note:1) All work shall be carried out by approved applicator of paint manufacture only. The same shall be approved before carrying out the work from GE. 2) Contractor should submit Auth applicator certificate before execution of work. 3) Contractor should submit warrenty certificate for 5 years from manufacturer. 4) Columns, Beams and Chajja to be painted different colour as per direction of Engr-in-Charge
Material and labour for preparation of newly plastered surfaces and applying two coats of oil bound distemper white or tinted with roller application over a coat of chalk whitening primer over 3mm thick wall care putty complete all as specified and as directed.
M&L for complete removal of existing treatment from old decorated plastered surfaces by Vacuum based sanding machine, removal of nails etc & filling cracks/hole with putty and applying wall care putty upto 1mm thick as required (Multipurpose mixer shall be used for uniform and propper mixing of putty) and applying two coats of emulsion weather coat white/coloured over a coat of exterior water proof primer by auto roller as per site requirement complete all as specified and directed as per manufacturer instruction. Note:1) All work shall be carried out by approved applicator of paint manufacture only. The same shall be approved before carrying out the work from GE. 2) Contractor should submit Auth applicator certificate before execution of work. 3) Contractor should submit warrenty certificate for 5 years from manufacturer. 4) Columns, Beams and Chajja to be painted different colour as per direction of Engr-in-Charge
Material and labour for complete removal of existing treatment from old decorated plastered surfaces by Vacuum based sanding machine, removal of nails etc & filling cracks/hole with putty and applying two coats of oil bound distemper white or tinted with roller application over a coat of chalk whitening primer over 3mm thick wall care putty complete all as specified and as directed.
Material and labour for preparation of old decorated surfaces of Ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent walls and trading oil and greasy spots and applying for one coat of white wash complete all as specified and as directed.
S&F Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary fixing lugs, hold fast, Butt hinges, lock strike plate, including PCC 1:3:6 type C1 (20mm graded aggregates) as in bed blocks for hold fasts including necessary form works, including PCC 1:2:4 type B0 using 12.5 mm graded stone aggregates as in filling of pressed steel door frame etc complete, size of frame 125x60mm incl bottom of each chowkat complete all as specified.
All as per item ser no-157 above here in before but two run single core 10 sqmm for phase and neutral and one run single core 10 sqmm as earth wire (ie 3X10 Sq mm)
Material and labour for 30 mm thick flush shutters, solid core construction, with block board core and covered with decorative face veneer with lipping/frame to match on both faces complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new steel surfaces over 10 cm girth and applying two coat of synthetic enamel painting over a coat of zinc primer complete all as specified and as directed by Engr-in-charge.
M&L Preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer.
Material and labour for one coat of synthetic enamel painting on old painted Steel surfaces of any description, not otherwise described over 10cm width or girth including preparation complete all as specified and as directed by Engr-in-charge.
Supply and fix Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and as directed.
Taking up or down 20mm bore steel water tubing and connections including removal complete all as specified and as directed by Engr-in-charge.
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including clamping to walls complete all as specified.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the permises etc complete all as specified and as directed by Engr-in-charge.
Material and labour joint free non skid ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster on brick work or Concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc.
S & F in repair 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
M & L for Cutting out cracks to V section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete al as specified and directed
Screed bed or bedding layer of mortar 5 mm thick for laying floor finishes with Water Proofing Compounds in CM 1:3 ( WPC will be measured and paid separately) complete al as specified and directed
M & L for removal of old APP membrane and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0kg of cement per sq. metre and applying APP based polymeric membrane weighing 3.5 to 5kg/sqm and minium 3mm thick reinforced with polyester non woven fabric (weight not less than 150 gms/ sqm) laid on primed surfaces with industrial bitumen 85/25, @ 1.20 Kg/Sqm over bitumen primer . by gas flame torch application and cleaning surfaces, applying evenly a tack coat/primer of industrial bitumen 85/25 grade at the rate of 1.20kg/sqm over APP membrane complete all as specified and as directed by Engr-in-charge.
M & L for plain cement concrete type B2 1:2:4 (using 20 mm graded aggregate) Cement concrete in foundations, filling and mass concrete, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars, posts etc...complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete al as specified
M &L 50mm thick Cement Concrete type C-1, 1:3:6 (20mm graded aggregate) as in floors
M &L Providing, cement concrete type C-1, 1:3:6 (20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges
Material and labour for plain cement concrete type D-2, 1:4:8 (Using 40mm graded stone aggregates) as in sub base complete all as specified and as directed by Engr-in-charge.
Material and labour for chequred cement concrete tiles 300x300x20-22mm thick set, jointed and pointed in neat cement slurry with grey pigment cement and pigments over 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed by Engr-in-charge.
M&L Integral waterproofing compound
M&L 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:4 complete all as specified and as directed by Engr-in-charge.
M&L for Joint free Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-charge.
S&F in repairs 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engr-in-charge.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets (10 ltrs) including PVC 32 mm dia, for low cistern complete all as specified and as directed by Engr-in-charge.
S & F in repairs vitreous china urinal partition slabs white of size 310 x 770 mm terminating about 40 cmabove floor line, fixed complete.
Dismantling and breakingup drain pipes AC /CI /PVC Pipes set in cement mortar 100mm/75mm bore.
S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 75mm PVC (SWR) bends any radius with access door.
S&F 110mm PVC (SWR) bends any radius with access door.
S&F 75mm PVC (SWR) vent cowl
Material and labour for Complete removal of existing treatment and applying two coat of white wash on walls complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of old decorated wall/ceiling surfaces by washing rubbing down and stopping of distempered surfaces and filling the nail holes by white cement and applying two coat of oil bound distemper white or tinted with roller complete all as specified and as directed by Engr-in-charge.
Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fix
ing etc. complete all as specified and as directed.
Supply and fix powder coated anodised sliding/hung type aluminium door, window and ventilator shutters (minimum thickness of powder coating 50 micron), without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2Nos) suitable handle (1 No), aluminium tower bolt 100 mm (1No) etc. complete all as specified and as directed
S&F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
Supply and fix for powder coated anodised aluminium grill of 8x 8mm bars size of opening 10cms size mesh with aluminium channel 'F' angle 20x 15mm aluminium frame work complete all as specified and as directed
M&L for complete removal of existing treatment from old decorated plastered surfaces by Vacuum based sanding machine, removal of nails etc & filling cracks/hole with putty and applying wall care putty upto 1mm thick as required (Multipurpose mixer shall be used for uniform and propper mixing of putty) and applying two coats of Acrylic emulsion exterior weather coat white/coloured over a coat of exterior water proof primer by auto roller for upto G+6 storey bldg as per site requirement complete all as specified and directed as per manufacturer instruction. Note:1) All work shall be carried out by approved applicator of paint manufacture only. The same shall be approved before carrying out the work from GE. 2) Contractor should submit Auth applicator certificate before execution of work. 3) Contractor should submit warrenty certificate for 5 years from manufacturer. 4) Columns, Beams and Chajja to be painted different colour as per direction of Engr-in-Charge 5) Workers should wear appropriate personal protective equipment.
Supply,Fixing and Testing warm LED highbay light fitting of 120 Watt, Luminaire fitting of IP 66 protection comprises of Pressure die cast Aluminium housing powder coated, toughened glass,LED's provided with secondary lens optics,luminaire efficacy not less than 140 lm/w provided with SPD 10 KV included complete all as specified and directed. Make - Crompton Cat No. CIP-327-120-57-60D-HL5-LM-NSG or equivalent model in Philips/Wipro/Surya
Material and labour for prepration of newly plastered surface of ceiling applying three coats of white wash complete all as specified .
S & F 35 mm thick 2nd class hardwood partly glazed and skeleton and party panelled shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cat and mitred beads for securing glass etc fitted to chowkats for windows, ventilators,etc complete, size of member of shutter as spd in SSR Part -I, Sec 8, clause 8.24 (b).
Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures, PVC conduits and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials from wall/ceiling etc to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed.
Material and labour for Point wiring with 1.5 sqmm (Nominal area) unsheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into existing concealed conduit through Wall/Ceiling/Flore along with FRLS 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly and including 2 mm thick terminal boxes MS sheet flush mounted with 3 mm thick laminated hylem sheet fixed with camium plated iron screws for mountling switches, socket, fan regulators etc complete for for the following point wiring and making good disturbed surfaces matching with existing paint complete all as specified and as directed. Make of PVC copper conductor cable:- Finlex/Poly cab/ Havells.
One light/fan point controlled by one switch with cable 1.5 Sqmm size..
One bell/buzzer point controlled by one push button with other switches on indipendent board with cable 1.5 Sqmm size.
All as per item ser no-121 above here in before but one 3 pin socket outlet 5 Amps, same board with cables 1.5 Sqmm size.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq.m each all as specified and as directed by Engr-in-charge.
All as per item ser no-121 above here in before but one 3 pin socket outlet 5 Amps, independent board with cables 2.5 Sqmm size.
All as per item ser no-121 above here in before but one 5 pin socket outlet 5/15 Amps, indipendent board/AC/Geyser with cables 4 Sqmm size.
Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into including PVC conduit of minimum 20 mm dia concealed/surface wiring through Wall/Ceiling/Flore etc including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following
All as per item ser no-125 above here in before but one 3 pin socket outlet 6 Amps, Independent board with cables 2.5 Sqmm size.
Supply and fixing Modular switch one way 5/6 A white Active one module all as specified and as directed by the Engineer-in-Charge. Make: Havells(Crabtree)/Legrand/Plaza.
Supply and fixing Modular switch Bell push,, 5 A white Active one module all as specified and as directed by the Engineer-in-Charge. Make: Havells(Crabtree)/Legrand/Plaza.
Supply and fixing Modular socket 5 Amp, 2/3 pin Active white two module complete all as specified and as directed by the Engineer-in-Charge.Make: Havells(Crabtree)/Legrand/Plaza.
Supply and fixing Modular switch one way 16 A white Active one module all as specified and as directed by the Engineer-in-Charge. Make: Havells(Crabtree)/Legrand/Plaza.
All as per item No.115 here-in-before but on vertical surfaces over 10mm thick screed plaster in CM 1:4.
One light/fan point controlled by one switch.
Point
Taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matches with existing colour of wall, floors, etc. all as specified and as directed.
GI metal flush box, 2 Module
GI metal flush box, 4 Module
Supply and fixing Modular socket 16 A, 5 pin multi purpose Active white two module complete all as specified and as directed by the Engineer-in-Charge .Make: Havells(Crabtree)/Legrand/Plaza.
GI metal flush box, 6 Module
GI metal flush box, 3 Module
GI metal flush box, 8 Module
GI metal flush box, 12 Module
Cover plate with frame,1 Module
Cover plate with frame,2 Module
Cover plate with frame,4 Module
S&F Ceiling rose three terminals/ PVC/ polycarbonate, isolated body complete all as specified and as directed by Engr-in-Charge Make: Anchor/ABB/Leader
Cover plate with frame,3 Module
Cover plate with frame,8 Module
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and Fixing and Testing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 66 protection with Surge Suppressor 5 KV complete and making good disturbed surfaces including taking down old u/s post top lanten all as specified and directed. Make : Surya / Philips/ Bajaj /Crompton.
Supply and fix for Buzzer, Ding Dong AC, 230 volts, single pole. Make: Anchor, GM,
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including making hole/cutting wall/fixing complete all as specified and as directed.
Supply and fixing in repair of modular fan step regulator,120 W-2 module all as specified and as directed by the Engineer-in-Charge.Make: Havells(Crabtree)/Legrand/Plaza.
Taking down ceiling fans of any make and sweep from ceiling hook/existing position complete including disconnecting and transporting to workshop for repairs all as specified and as directed.
Hanging only ceiling fans any make and sweep after repairs to ceiling hook by connecting with 3 core copper flexible round cable from ceiling rose to fan complete incl shifting from workshop all as specified and as directed.
Supply and fixing in repair of GI metal flush box suitable for mounting moduler plate including removing old rusted metal box from site as per requirement of following modules:-
Supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes for following modules:-
Supply and fix high efficiency wall mounted LED light fitting 4 feet white, 20W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old one and taken as credit complete all as specified and as directed. (Make:- Philps Cat Part No. BN021C LED20S PSU CDL GR or or Equivalent in Panasonic, C&S, Havells)
Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-chargeMake: Siemens/Scheneider/ABB Note : Including taking down old unserviceable.
Supply and replacement of Metal clad socket single pole and neutral enclosure with a two pin + earth plug top and socket complete with one doble pole 20-32 Amps MCB C Type 230 Volts all as directed.
Supply and fix for MCB TPN 230 V, 40-100 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-chargeMake: Siemens/Scheneider/ABB Note : Including taking down old unserviceable.
Supply and fix for MCCB 4 Pole, 415 V,adjustable Thermal & Fixed Magnetic setting type type 150 Amps with breaking capacity 36 KA complete all as specified and as directed by Engr-in-charge.Make: Siemens/Scheneider/ABB, Note : Including taking down old unserviceable.
All as per item ser no-125 above here in before but one 3 pin socket outlet 6 Amps, Independent board with cables 2.5 Sqmm size.
Supply and fixing Modular switch one way 5/6 A white Active one module all as specified and as directed by the Engineer-in-Charge. Make: Havells(Crabtree)/Legrand/Plaza.
Supply and fixing Modular switch Bell push,, 5 A white Active one module all as specified and as directed by the Engineer-in-Charge. Make: Havells(Crabtree)/Legrand/Plaza.
Per point
S&F sheet metal enclosure TPN MCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements all as specified and directed Note :-(i) Including taking down old u/s DB, MCB's (ii) MCBs shall be measured and paid separately under the respective item of shedule. Make : Legrand/ Siemens/Scheneider/ABB/ Havells.
Cover plate with frame,6 Module
Cover plate with frame,12 Module
Hiring boom lift/ crane suitable for minimum 10-15 mtr height for servicing, checking for repair / replacement of highbay lighting and other allied items installed at Hangers , including necessary operator,fuel,T&P, safety equipments/to
ols complete required for safe operation complete all as specified and directed. Note: Each day is minimum of 8 Hrs of working (2) Submain wiring minimum 300RM is considered in one Job.
M & L for rewinding of burnt out exhaust fan 300-380 mm sweep motor with super enameled copper winding wire of suitable gauge/size including necessary tapping, varnishing etc, including taking down burnt copper winding and necessary transportation to workshop and back and fixing and testing all as directed.
Material and labour for Sub main wiring with Four run single core 10 sqmm for phase and neutral and two run single core 10 sqmm as earth wire with multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade confirming to IS-694 continuity conductor drawn into existing concealed conduit through Wall/Ceiling/Flore including taking down old sub main wiring and taken as credit complete all as specified and as directed. Notes: (i) The disturbed surfaces shall be made good with e
xisting surface including finishes as applicale. (i) Four different color wires shall be used for phase and neutral . (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles . Make of cable:- Finlex/Poly cab/ Asian. Make of PVC conduit : Avon plast/ Kon seal / Garware.
Supply and fixing in repair of Modular step type fan regulator,120 W white Active two module all as specified and as directed by the Engineer-in-Charge.Make: Havells(Crabtree)/Legrand/Plaza.
Each Job
Material and labour for Sub main wiring with Two run single core 2.5 sqmm for phase and neutral and one run single core 2.5 sqmm as earth wire with multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade confirming to IS-694 continuity conductor drawn into existing concealed conduit or non-metallic rigid PVC conduit of minimum 20 mm dia as per site requirement wiring through wall/cable tray/ceiling/floor/roof etc including conduit accessories including taking down old sub main wiring with PVC conduit and taken as credit complete all as specified and as directed. Notes: (i) The disturbed surfaces shall be made good with existing surface including finishes as applicale. (i) Two different color wires shall be used for phase and neutral . (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles . (iv) Three run of 2.5 Sqmm cable, and one run of PVC conduit will be measured as one unit. Make of cable:- Finlex/Poly cab/ Havells. Make of PVC conduit : Avon plast/ Kon seal / Garware/ Finolex.
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.55 MB
SummaryPage8521.pdf
Additional Documents • 0.08 MB
NIT8521R.pdf
Additional Documents • 0.54 MB
Tenderdocuments8521R.pdf
Tender Documents • 0.86 MB
BOQ_830377.xls
BOQ • 0.37 MB
Scheduleofcredit8521.pdf
Additional Documents • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .