| 1 | L1₹3.5 LAccepted-AOC 36 RANJEET NAGAR SHAHBAD MARKANDA NH 1 KURUKSHETRA HARYANA 136135 | KURUKSHETRA | HARYANA | 136135 | ₹3.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹3.8 L+₹27,000 (7.76%)Rejected-Finance B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | ₹3.8 L+₹27,000 (7.76%) | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Rishi Markandeshwar Engineering Consultant L1 | GEO DESIGNS AND RESEARCH PVT LTD L2 |
|---|---|---|---|---|---|
| 1.00Conducting Soil investigation (Bore Holes) as per IS :1892-2021 by manually/calax rotary drilling of 100 mm diameter with casing pipe/bentonite slurry if required for supporting inner collapsible stratum below water table with pot holes/helical auger in any type of soil upto depth required. Conducting standard penetration test (SPT) at regular intervals and submit the the SBC report. Disturbed and undisturbed soil sample to be collected at a sampling interval of 1.00 mtr depths or at change of strata or as per relevant IS Code. | |||||
| 1.01Note:- A) The following laboratory test are required to be conducted on disturbed soil and detailed result to be given in tabular form:- (i) Sieve analysis & Grain Size distribution by sieve analysis & hydrometer test. (ii) Atterbergs Limits (iii) Natural Moisture Content test (iv) Particle size analysis test (v) Bulk density/dry density B) The following laboratory test to be conducted on undisturbed soil samples as considered necessary according to relevant specification of IS 2720 and detailed result showing all relevant calculations, inferences, indices and parameters shall be given in the soil report :- (i) Natural Moisture Content test (ii) Bulk density (iii) Specific gravity Test (iv) Free Swell Index Test and swelling properties of soil. (v) Organic matter in soil if any. (vi) Consolidation test (compressed index value) (vii) Triaxial compression test and determination of shear parameters (C & phi) test as per relevant IS. (viii) Harmful salt (complete investigation as already ref). C) Maximum and Minimum levels of Ground Water in the area with source of information and Ground water Table observed during the observation. | |||||
| 1.02 | Bore Hole (BH1) Depth of 10 mtr
(For Auditorium - Plinth Area: 940 Sqm, Height: 9.9m) | 1 | Each | 42,000 ₹42,000 Lowest | 42,000 ₹42,000 Lowest |
| 1.03 | Bore Hole (BH2) Depth of 10 mtr
(For Fire Fighting Pumphouse - Plinth Area: 75 Sqm, Height: 3.35m) | 1 | Each | 42,000 ₹42,000 Lowest | 42,000 ₹42,000 Lowest |
| 1.04 | Bore Hole (BH3) Depth of 10 mtr
For Substation Bldg - Plinth Area: 34.33 Sqm, Height: 3.2m) | 1 | Each | 42,000 ₹42,000 Lowest | 42,000 ₹42,000 Lowest |
| 1.05 | Bore Hole (BH4) Depth of 15 mtr
For UG Sump - Capacity: 1,00,000 litre) | 1 | Each | 63,000 ₹63,000 | 55,000 ₹55,000 Lowest |
| 1.06 | Bore Hole (BH1) Depth of 10 mtr
For Swimming pool Building Annex (Plinth Area: 242.35 Sqm, Height: 3.2m) | 1 | Each | 42,000 ₹42,000 Lowest | 42,000 ₹42,000 Lowest |
| 1.07 | Bore Hole (BH2) Depth of 10 mtr
For Spectator Gallery (Plinth Area: 175 sqm, Height: 6.4m) | 1 | Each | 42,000 ₹42,000 Lowest | 42,000 ₹42,000 Lowest |
| 1.08 | Trial Pit Size (1.2mx1.2m) of 3 mtr depth, 5 mtr away from Bore Hole (For Auditorium 3 Nos. & For Swimming Pool 2 Nos.) | 5 | Each | 5,000 ₹25,000 Lowest | 11,000 ₹55,000 |
| 2.00 | Carrying out topographical survey by using total station with spot levels at 3m c/c and marking of existing structure/features of ground including submission of EIGHT sets of survey report containing contour plan @ 1m contour interval and block level plan with 3m c/c spot levels etc. All complete (Approx. Area is 6000 Sqm) (Location: Auditorium area 6TTR) | 1 | Job | 50,000 ₹50,000 Lowest | 55,000 ₹55,000 |
Tender Value
₹4.6 L
EMD Value
₹9,500
Closing Date
7 Aug 2026, 6:00 pmClosed
GE PANAJI
GARRISON ENGINEER OPPOSITE KALA ACADEMY ST INEZ ROAD PANAJI GOA 403001
PRELIMINARY ACTIVITIES IN RESPECT OF SOIL INVESTIGATION AND TOPOGRAPHICAL SURVERY FOR THE WORK PROVN OF AUDITORIUM HALL OF 300 CAPACITY AT 6 TTR PONDA AND ADDITION AND ALTERATION AND SPECIAL REPAIR OF SWIMMING POOL ATR 3 MTR MADGAON (GOA)
2026_MES_777682_1
8330/E8
Open Tender
Survey
Item Rate
30 days
GE PANAJI
Please refer Tender documents.
7 documents required · 7 mandatory
₹300
GARRISON ENGINEER PANAJI
₹9,500
Yes
24 Aug 2026
10 Jul 2026
14 Aug 2026
10 Jul 2026
7 Aug 2026
24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Conducting Soil investigation (Bore Holes) as per IS :1892-2021 by manually/calax rotary drilling of 100 mm diameter with casing pipe/bentonite slurry if required for supporting inner collapsible stratum below water table with pot holes/helical auger in any type of soil upto depth required. Conducting standard penetration test (SPT) at regular intervals and submit the the SBC report. Disturbed and undisturbed soil sample to be collected at a sampling interval of 1.00 mtr depths or at change of strata or as per relevant IS Code. | |||||
| 1.02 | Bore Hole (BH1) Depth of 10 mtr
(For Auditorium - Plinth Area: 940 Sqm, Height: 9.9m) | 1 | Each | - | - |
| 1.03 | Bore Hole (BH2) Depth of 10 mtr
(For Fire Fighting Pumphouse - Plinth Area: 75 Sqm, Height: 3.35m) | 1 | Each | - | - |
| 1.04 | Bore Hole (BH3) Depth of 10 mtr
For Substation Bldg - Plinth Area: 34.33 Sqm, Height: 3.2m) | 1 | Each | - | - |
| 1.05 | Bore Hole (BH4) Depth of 15 mtr
For UG Sump - Capacity: 1,00,000 litre) | 1 | Each | - | - |
| 1.06 | Bore Hole (BH1) Depth of 10 mtr
For Swimming pool Building Annex (Plinth Area: 242.35 Sqm, Height: 3.2m) | 1 | Each | - | - |
| 1.07 | Bore Hole (BH2) Depth of 10 mtr
For Spectator Gallery (Plinth Area: 175 sqm, Height: 6.4m) | 1 | Each | - | - |
| 1.08 | Trial Pit Size (1.2mx1.2m) of 3 mtr depth, 5 mtr away from Bore Hole (For Auditorium 3 Nos. & For Swimming Pool 2 Nos.) | 5 | Each | - | - |
| 2 | Carrying out topographical survey by using total station with spot levels at 3m c/c and marking of existing structure/features of ground including submission of EIGHT sets of survey report containing contour plan @ 1m contour interval and block level plan with 3m c/c spot levels etc. All complete (Approx. Area is 6000 Sqm) (Location: Auditorium area 6TTR) | 1 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_870999.xls
BOQ • 0.27 MB
Tenderdocument_1.pdf
Tender Documents • 1.02 MB
Corrigendum.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .