Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance UDHAMPUR | Admitted-Finance |
| 3 | Admitted-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹86,400
Closing Date
15 Feb 2023, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
creation of substation along with HT and LT line
2023_PDD_202012_1
ED/UDH/97 of 2022-23, dt. 09/01/2023
Open Tender
Electrical Works
Turn-key
90 days
At Shatrari, Khuga in Distrcit Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer, Electric Division JPDCL
₹86,400
27 Apr 2023
9 Jan 2023
17 Feb 2023
9 Jan 2023
15 Feb 2023
9 Jan 2023
9 Jan 2023 - 4 Feb 2023
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at WSS Shatrari (Khuga).
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR conductor
PG Clamps for 30mm² ACSR conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20mm, 2.5 mtr. Long through G.I Strip 25x3mm
Painting of ST poles 9 mtr. with 1 coat of Red oxide
Painting of ST poles 9 mtr. with 2 coat of Aluminium paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 715 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 63 KVA at WSS Shatrari (Khuga)
11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
120mm², 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-Phase 4 Wire LT Prodigy Meter with Box.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 1 coat of Red oxide & 2 coat of Aluminum paint.
Al ladder 20 feet long Heavy Duty
Safety Helmets ISI Marked ISI 2925
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
11kV GO, Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
M R ENGINEERS & TRADERS
vijay builders
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .