Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 CrAccepted-AOC | ₹10.7 Cr | L1 | Accepted-AOC Awarded Contract Bidder |
| 2 | L2₹11.6 CrRejected-AOC WARD NO 07 D K ROAD LAKHIMPUR ASSAM | ₹11.6 Cr | L2 | Rejected-AOC Rejected as L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per decision of Bid Evaluation Committee |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per decision of Bid Evaluation Committee |
Tender Value
₹12.1 Cr
EMD Value
₹24.3 L
Closing Date
14 Jul 2022, 2:00 pmClosed
Chief Engineer,(EAP) PWRD,Assam
O/o The Chief Engineer,(EAP) PWRD,Assam Fatasil Ambari,Guwahati- 781025
APART/NOCP/WAREHOUSES/K-04 Renovation and Upgradation of Warehousing Facilities under the scheme of APART in existing Warehouse Complex at Maidamgaon (Plot-1)-Model in Kamrup (M) District.
2022_PWRDW_25964_6
CE/APART/135/2022/8
Open Tender
Civil Works - Building
450 days
Kamrup (M) District.
Please refer Tender documents.
6 documents required · 6 mandatory
₹20,000
₹24.3 L
Yes
O/o The Chief Engineer,(EAP) PWRD,Assam
5 Jan 2023
15 Jun 2022
14 Jul 2022
15 Jun 2022
14 Jul 2022
15 Jun 2022
15 Jun 2022 - 24 Jun 2022
24 Jun 2022
Amount
Supplying, Installing and Fitting of Pallets of size (800x1000x160) mm (may vary in accordance with the racking system), H4 Eco plastic pallet with 3 runner rims suitable for all kind of material to be stored. The pallet should match with the racking system of material handling equipments to be installed in the warehouse; as approved, specified and directed by Engineer-in-Charge
Supplying, Installation & Commissioning of Iron Removal Filter with prior inclusion of Soda Ash for PH Correction and Sodium Hypochlorite for disinfection through a proper dosing system and undergoing Reverse Osmosis for the purpose of drinking.
Earth work in excavation for structures as per drawing and Technical 25.500 specification clause 305.1l including setting out, coonstruction of shoring and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and backfilling in trenches with excated suitable material 17 Cum bottom and with excavated material Ordinary soil upto 3 m to 6 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A With crushed P.C.C grade M 10
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 RCC Grade M 20 For height upto 5 m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 Sandy material
Providing weepholes in brick masonry/stone masonry, plain/reinforced 71 concrete abutment, wing wall, return wall with 100 mm dia AC pipe
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
Setting Out Unit= 1KM Reference Bench Mark and Bench Mark pillar as per MORD and Technical Specifications Clause No.- 100 v) typical benchmark as per drawing 200.
Clearing and Grubbing Road Land .(Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to beused or auctioned up to lead of 1000metres including removal and disposal of top organic soil not exceeding 150mm thickness.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). Depth not exceeding 1.5 m
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered) Depth exceeding 1.5 m but not exceeding 3 m
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (ex cluding the cost of chemical emulsion) : Along external wall where the apron (existing) is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration add 20 % extra
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
EARTHWORK Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate (12.5mm nominal size).
REINFORCED CEMENT CONCRETE WORKS Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manu factured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA) upto 20%.
FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
MASONRY WORKS Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
HALF BRICK MASONRY Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand)
Half Brick masonary with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level V Cement mortar 1:3 (1 cement : 3 coarse sand)
FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm
CHOWKATHS Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).
REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level : Concrete of M25 grade with minimum cement content of 300 kg /cum
BRICKWORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level V in all shapes and sizes in: Cement mortar 1:4 (1 cement : 4 coarse sand)
CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand(zone-III) : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls (i) Under 20cm wide
PLASTERING 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
PLASTERING 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
KOTA STONE FLOORING Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
DISTEMPERING Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
PAINTING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats)
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Painting with aluminium paint of approved brand and manufacture to give an even shade : One or more coats on old work.
Applying Priming Coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Applying Priming Coat With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Upvc Window Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
FLOORING Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick.
MS SHEET DOOR Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Crimped Eave
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete .
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
GRILL WORKS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.n gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
IRON & STEEL WORK Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete
Providing and fixing bolts including nuts and washers complete.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete: Barge board (Upto 300 mm)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Bend 87.5° 75 mm bend
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Shoe Plain 75 mm shoe
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches (ii) 90 mm dia.
ANTI-TERMITE TREATMENT Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron (existing) is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
PLINTH PROTECTION AND DRAIN Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
DISMANTLING Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge
Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
DISMANTLING AND DEMOLISHING Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkaths. Architrave, holdfasts etc. complete and stacking within 50 meters lead: Of area 3 sq. meters and below
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil.
By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM Sand, stone aggregate below 40 mm nominal size Cost of carriage including loading, unloading & stacking for first 50 metres.
By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM Sand, stone aggregate below 40 mm nominal sizeEvery additional lead of 50 metre or part thereof beyond 1st 50 metre 9 such additional lead.
By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM stone aggregate below 40 mm nominal size Cost of carriage including loading, unloading & stacking for first 50 metres.
By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM , stone aggregate below 40 mm nominal sizeEvery additional lead of 50 metre or part thereof beyond 1st 50 metre 9 such additional lead.
Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :Up to 6 metres depth
Supplying of following LED lighting fixtures complete with Drive and Lamps with reflector/cover etc. complete as required:- Make : Sisk / CGL/ Havells/ Surya or Panasonic as approved 1 x 20 W LED 6500K retrofitting polycarbinateT8 tube with in built driver and heat sink double sided connection with compact commercial batten suitable for T8 LED tube Make ;CGL Cat Ref. LT820865 and for batten unilite DMLN1LT8-16 or equivalent Siska or Havells , phillips, bajaj as approved. for small class room lighting
Supply and installation of angle batten holder with 12W LED NW lamp .
Supply of 60W LED flood light . Make ; Siska, SSK-BLS-CF-60W
Supply and Installation of3 blade 1400 mm sweep white SUMMER BREEZE ceiling fan. Make ; Oirent or equivalent Havells or CGL make as approved. For hostel room and foyer area
Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEI Or equivalent as approved 3 Core, 6 sq.mm. XLPE ARMOURED Aluminium Cable. Form MDB to Office building and pump house SPN DBs
Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEI Or equivalent as approved 4 Core, 10 sq.mm. XLPE ARMOURED Aluminium Cable. Form MDB to Godown 3 TPN DB
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 120 sq.mm
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 25 sq.mm
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Structural supports as required for cable trays complete with installation with anchor fastner/grouting as applicable. Painting with red oxide and 2 coats of enamel paint of colour as specified by Owner/Consultant.
Providing, laying, terminations of copper wire and strip of undernoted sizes in surface for connection etc. with lugs .8 SWG wire
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :32mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150mm
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200mm (6mm thick)
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250mm (6mm thick)
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing and fixing STRAINER Y type with M.S. flanged connection. 100mm
Providing and fixing STRAINER Y type with M.S. flanged connection. 150mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6):80mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6):100mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6):150mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6):200mm
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Providing and fixing of gun metal 63mm dia short branch pipe , ISI marked (IS: 903).
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
Providing and fixing M.S cabinet fabricated from 16 gauge M.S. sheet with double front glass door and locking arrangement with suitable shelves including space for 50 spare sprinkler and one spanner properly fixed in the shelves and cabinet painted with enamel paint of approved shade, size 900x600x150mm.
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :100mm dia
Providing and fixing fire hose cabinet of size 900x600x300 fabricated from 16 gauge MS sheet of fully welded construction with hinged double front door with locking arrangements and partially glazed with 5mm thick glass stove enamelled fire red finish with fire hose written on front suitable to house 2x15 hose with couplings, one branch pipe (for external yard hydrants). Design to be got approved by Engineer-in-Charge before fabrication.
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve &nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
Providing and fixing G.M. stop valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes.25mm
Providing and fixing G.M. stop valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes.40mm
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.NON - RETURN VALVE of 150 mm dia
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.NON - RETURN VALVE of 100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required 2 way-100 mm dia M.S. Pipe
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 6 Kg. Complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming to IS: 2171.
Providing and fixing portable fire extinguisher carbon dioxide type with cylinder initially fully charged with CO2 gas of 4.5 Kg. Capacity, complete with discharge valve, dishcarge tube, horn, CI bracket for wall mounting etc. conforming to IS: 2878.
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 65 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 200 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 250 mm dia
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 25mm
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 50mm
Providing and fixing gunmetal four way collecting head with 63mm dia instantaneous type inlet with built in check valve for fire brigade connection to underground tanks as per IS: 904.
Providing and fixing standard draw out connection with 63mm dia instantaneous type coupling and FOOTVALVE with all accessories as approved by fire authorities for installation at under ground tank.
common Light Point wiring in Steel conduit - Wiring for common light point / fan point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recess or surface Steel conduit ( to be fitted with. Group A
common Light Point wiring in Steel conduit - Wiring for common light point / fan point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recess or surface Steel conduit ( to be fitted with. Group B
common Light Point wiring in Steel conduit - Wiring for common light point / fan point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recess or surface Steel conduit ( to be fitted with. Group C
Common Light Point wiring in Steel conduit - Wiring for common light point / fan point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recess or surface Steel conduit ( to be fitted with the truss member by sport welding ) as required.. Make : conduit as approved by CA, Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. 2 x 1.5 Sq.mm + 1 x1.5 Sq.mm earth wire for common light point wiring from Primary point to two nos. secondary points as shown in the drawing
Supplying and fixing following piano type switch and socket on the existing switch box/ cover including connections etc. as required as directed. 5/6 amps switch and 5/6 amps socket for light power point in existing switch boards as directed.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required ( from SPN DB to Switch boards ) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required ( from SPN DB to Switch boards ) 2 x 6 Sq.mm + 1 x6 Sq.mm earth wire from TPN DB to SPN DB of Godown
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep for LP
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 150 mm X 60 mm deep for PP
Supplying and fixing following piano type switch and socket on above switch box/ cover including connections etc. as required as directed. 5/6 A switch
Supplying and fixing following piano type switch and socket on above switch box/ cover including connections etc. as required as directed. 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch and socket on above switch box/ cover including connections etc. as required as directed. 15/16 A switch
Supplying and fixing following piano type switch and socket on above switch box/ cover including connections etc. as required as directed. 6 pin 15/16 A socket outlet
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire ( from SPN DB to Switch boards )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire from DB to Light power point as directed
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 4 Sq.mm + 1 x4 Sq.mm earth wire from DB to power point
Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 8- way , Double door for pump house
Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 12- way , Double door for godown 1 & 2 and office building..
Supplying and fixing of following ways surface/ recess mounting,horizontal type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 4 way (4 + 12), Double door for Godown power distribution and to be install in godown 3 varanda.
Supplying and fixing 5 amps to 32 amps rating, 240 / 430 volts, 10 KA 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (10KA)
Supplying and fixing 5 amps to 32 amps rating, 240 / 430 volts, 10 KA 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral (16 KA) for SPN DBs
Supplying and fixing 5 amps to 32 amps rating, 240 / 430 volts, 10 KA 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole for and neutral for TPN DB incomming (25 KA)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A to be installed in SPN DBs
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Installation, testing and commissioning of prewired, flourescent fittings / all type of LED indoor ceiling fittings , complete with all accessories and tube etc. directly on ceiling/wall/ False ceiling, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing stepped type elctronic fan regulator on the existing modular plate switch box excluding modular plate as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as required for out door lighting system & indoor DBs. One for VTPN and 1 for washr room and 1 for cofee house .
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing earth bus bar joint made of 20mmx3mm thick 125 mm long with 6 nos. G.I bolts , nuts, chuck nut and spring washers etc. complete as requried
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of building walls addirected Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35sq. Mm
Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required. 3C X 6 sq. mm (19mm)
Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required. 4C X 10 sq. mm (19mm)
Supplying and embedding following G.I pipe of medium class for cable entry / road crossing of cable etc. including bending the pipe as required shape as required. (For varanda and road crossing as directed.) a) 32 mm dia
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Supplying, Installing and commissioning of 19.5 KWp On Grid Solar Power Plant: Solar Power Plant :19.2KW Solar PV module in Watt 300 Wp Solar Panel Qty 64 nos. Solar On Grid Inverter 20 KW MC4 Connector24 Pair DC Cable 3.5 core *4 sq mm 400 Mtr ACDB 1 no 20KW DCDB1 no 20KW ESE Based Lightning Arrester with all accessories 50 Metre Radius Earth Pit with Chemical Earthing 3 M Earth Electrode 4 nos GI Strips 25*5 100 metres with making necessary connection as approved, specified and directed by the Engineer. (Civil works in support structure & Electric panel to be measured & paid separately)
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 56 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)orizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.80 lpm at 56 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads .2280 lpm at 56 m Head
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of Soil
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) from private land
Traffic Signs A) Retro - reflectorised Traffic Signs (1) Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mm x 450mm x 600mm, 600mm below ground level as per approved drawings and Technical Specification Clause 801. (ii) 600 mm equilateral triangle
Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. Random Rubble Masonry In cement mortar 1:4For Part I Road L= 75.00 M ( For Drain )
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.2 with lead upto 1000 m. as per technical specification clause 303.1 (a) from private land
GRANULAR SUB-BASE WITH WELL GRADED MATERIAL (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
WATER BOUND MACADAM SUB-BASE/BASE Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. 2) WBM Grading II Using stone screening Type-B 11.2 mm for Gr.II
3) WBM Grading III Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
CEMENT CONCRETE PAVEMENT INTER LOCKING CONCRETE BLOCK PAVEMENT (A) Interlocking pavement block (i) Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage (a) Including Edge block/ Edge restraints.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (b).Brick on edge soling.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (300mm wide and average 300mm deep with bed slope 1 in 200 with initial depth of 150mm.)
RETROFITTING WORKS Chippng and breaking/cutting of loose concreate , motars etc.using Electrical chipping hammers to the satishfaction of the engineer-in -chargefor succesful execution of thr subsequent rehabitation works all heights with all leads , lift etc . Complete ith all tools and machineries required for the job ,operator, applicator ,labour, scaffolding for staging and supervision etc. Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/Choskey
Providing and applying two coats of two component epoxy zinc rich primer like Fosroc Nitozinc Primer or equivalent on the properly cleaned reinforcement after the required chipping and cleaning of the concreate surface as per the manufacyure’s specification at a dry flim thickness of 40 micron /coat.The epoxy zinc rich primer should have a adhesive bond strength with steel greater than 1.5 N/Sqm.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and applying structural grade long pot life epoxy bonding agent of like Nitobond EP or equivalant prior to building up of section with any type of mortar/ concrete to ensure bond between old concrete & new concrete by brush application as per the manufacturer’s specifications.The bonding agent should remain in tacky state after application for a minimum period of 6 hours at 30 ºC. There shall not be bond failure of the specimenwhen tested by slant shear method according to BS 6319 pt 4, with concrete.
Providing and placing free flow micro concrete Renderoc RG / Sika Micro - concrete-2 or equivalent product of after fixing slurry tight shuttering. The micro concrete should be mixed mechanically while maintaining water, powder ratio of 0.16 strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer- in -Charge.The micro concrete should develop a compressive strength of 10N/mm2 within 1 day, 40N/mm2 within 7 days and 50N/mm2 within 28 days.The cost is inclusive of materials, transportation, labour, taxes etc. all completre.
Providing and Sealing the cracks, in the concrete surface, after opening the cracks using suitable tools or saw cut in the crack, and cleaning the interior sides of the crack using sharp tools to remove all loose materials, using two component, high strength, non- sag, epoxy compound like Nitobond PC40 or equivalent inclusive of all Manpower, Material and Equipment. Injection Of Low Viscous Resin: BY Providing and grouting the cracks after fixing the injection ports at predetermine locations with the help of suitable injection grouting pumps at suitable pressures using two- component, high strength, low viscous epoxy resin system grout like Conbextra EP10 or equivalent.(inclusive of Manpower, Material and Equipment). Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Drilling 12 mm dia X100 mm hole in to the concreate surface using concreate hammer drill machine. Providing 10mm PGMs nozzles is gird of 0.25 m both and injecting cement slurry Injecting cement slurry 1:3 ( 1 Cement: 3 water ) by weight including mixing of grout compound as per manufacture specifications , in cracks/ effected approved brand till completion and refusel of gout complite as per manufactures specification. The nozzles are to be sealed off after grouting using rapid setting cement based pluging mortar of approved brand.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Crack opening should be chiselled out to approximately 20mm X 20mm , and should always be undercut to avoid formation of a V shape and cut back to a minimum depth of 15 mm and given a good mechanical key to apply Single part, non shrink, cementitious, crack sealer like Fosroc Renderoc CS or equivalant for plaster, masonry and concrete as per manufactures specificationMake:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and Applying a two component structural grade polymer modified reinstatement mortar of approved brand up to a thickness of 10 mm over a epoxy rasin bonding agent like Fosroc Renderoc S2 or equivalent. The cured mortar shall achieve a compressive strength of 12 N/mm² in 1 day & 45 N/mm² in 28 days with Flexural strength 8 N/mm² in 28 days. Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated Electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. In addition to this percentage of water absorption should be 0.45 after 24 Hrs in immersion testMake:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
TURBO VENTILATOR Supplying, fitting and fixing in position turbo ventilator of Nylon made Typhonic Bearing, double top cap ensured permanent alignment in inverted cap design, corrugated foil framed of aluminium fabrication for wind driven having wind velocity 1600 exauster of effective throatal Dia 21 inch and overall dia 28 inch having overall height 17 inch as specified and directed by the Engineer-in-charge.
LOUVERS Providing & fixing louvers of size (450mmx300mm) at all heights with all leads- 3.5 mm thick toughened frosted glass louvers, 25 micron anodized aluminum sections for louver manufactured from best extruded aluminum sections from approved manufactures, the frame work fixed of jindal sections of minimum anodic coating of grade AC 15 with standard approved fastenings or hinges as per details specifications with all the sections pretreated for removal of any rust and prevention of any further rust, M.S. Grill of required size, one primary coat of red-lead/red oxide primer and two coats of enamel paint of approved brand and manufacture all complete as per specifications and direction by the Engineer-in-charge.
VDF Providing VDF flooring for top coat of floor with dewatering of concrete by vaccum pump and sprinkling non-metallic floor hardner @ 5 kg/sqm followed by a coat of cement slurry mixed with Nitobond SBR latex or equivalent @ 1 kg over 1.25 sqmtr and 67 ml. Nitobond SBR latex. Over the levelling reinforeced cement concrete base 1:1.5:3 simulteniously casted as per specification. 10mm x 12mm groove @ 5 mtr. or equally distributed pattern to be cut and filled with Polysulphide Sealent as grouting compound. Complete and finished in all respect as per company specification and Engineer-in-charge. (The R.C.C. work will be measured and paid separetly)
GROOVE CUTTING AND FILLING IN WALL Cutting of groove size 10mm x 12mm on walls above DPC edge and filled with Polysulphide Sealent as grouting compound. Complete and Finished in all respect as per company specification and Engineer-in-charge.
REBAR ANCHORING Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge.(Cost of the reinforcement will be paid extra)
REBAR ANCHORING 16 mm diameter of reinforcement bar as per embedment depth..
REBAR ANCHORING 20 mm diameter of reinforcement bar as per embedment depth..
UREA CORROSION RESISTANCE COATING Providing and applying a chemical and abrasion resistant , high build, two-pack epoxy-novolac system specially designed to provide a tough and impermeable high chemical resistant film at a thickness of 500 micron. The coating should able to resist wide range of chemicals both acid and alkaline having Ph value 1 o 14. The cured flim should have Tensile strength 30 N/mm²,Elongation 3%,flexture strength 45 N/mm²,Compresive strength 95 N/mm².
RECRON 3S Extra over Item 2.2.1 Providing Recron 3S shall be mixed with the approved concrete and laid over prepared subbase. The work shall be carried out as per direction by Engineer-in-charge. The materials, loading, unloading, transporting to site, removing rubbish from site, all taxes etc. complete for all lead and lift.
Fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates (in columns and trusses), bolts and nuts complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
Supplying materials and laying 25 mm thick self adhesive closed-cell nitrile elastomeric rubber insulation foam with non-porous composition, aluminium foam on one side, high thermal efficiency as well as protection from imminent condensation problems.The product should be environmental friendly and zero Ozone Depletion Potential (ODP). The self adhesived sheets are to be cutted in required size and shape should be fixed with necessary screws and rubber washers fixed to the truss members on both the direction. Including necessary accessories for fitting and fixing of sheet in position as complete as per the instruction of Engineer In Charge. The basic property of the material should be as follows : Fire rated “CLASS O” as per BS 476 Parts 6 & 7; Water vapour permeance (0 perms); Water vapour diffusion factor (> 10,000); Water absorption rate (0.06% by volume); Thermal efficiency (λ24˚ C = 0.033 W/mK; λ46˚ C = 0.036 W/mK); Temperature range (from -50˚ C to +105˚ C); Antibacterial & antifungal; Environmental friendly – ODP = 0; Low VOC emission level
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead.
Supplying, Installation & Commissioning of Manual Over Head Sectional Door made of 40 mm thick PPGL sandwich panels with 610 mm height fitted with additional steel reinforcement strip, protection class IP54, thermal insulation 1.60W/m^2K, air permeability class 3, resistance to water penetration class 3, resistance to wind load class 4, vision panel oval shaped 663x343 mm, normal lift, operated by chain hoist, colour RAL 9002. Size : 2500 x 3000mm; as approved, specified and directed by the Engineer.
Supplying, Installation & Commissioning of Retractable Dock Shelter made of 3mm thick Double Layered Polyester Fabric 3800 gsm with PVC coating curtain, side panel PVC coated cloth 600 gsm, framework extruded Aluminium (anodised), Bracing arm galvanized steel tubes, top slanted, 670 mm side curtains, 1000 mm top curtain, standard black colour with white warning stripes. Size : 3450 x 3400 mm; as approved, specified and directed by the Engineer.
Supplying, Installation & Fitting of Fire Rated Door (Size: 1400mmx2100mm); as approved, specified and directed by the Engineer.
Supplying, Installation & Commissioning of 3W Electric Forklift Capacity: 1.6 Ton at 500 mm Load Centre Power Source: Electric Battery: 48 V / 390 Ah Drive: Single (2 Tyres in front) Tyres: Solid Fork Length: 1000 mm Gradeability: 15% Mast Type: 2 Stage CV Maximum Fork Height: 3660 mm Overall Heiqht Lowered: 2515 mm Free Lift: 100 mm [Inclusive of Lights package (headlights , taillights, signal lights), Reverse Alarm , Load Back Rest, Battery Compartment Roller, Wet Disc Brake, Battery Charqer]; as approved, specified and directed by the Engineer.
Supplying, Installation & Commissioning of Fully Electric Stacker Capacity: 1500 kg. @ 600 mm Load Centre Overall width: 1344 mm Mast configuration offered: 3 Stage CVT Maximum fork height (MFH): 5500 mm Overall height lowered (OAHL): 2467 mm Overall height Raised (OAHR): 6000 mm Full Free lift (FFL): 1864 mm Capacity at MFH: 980 kg Width Across forks (outer-outer): 590 mm Traction Battery Rating: 24 V, 225 AH Drive Motor (Kw): 1.3 KW, AC Hydraulic Motor (Kw): 3 KW Right angle Stacking Aisle width 1200w x1200 L (W/W.O. Platform): 2432 I 2930 mm Standard Accessories: Operator Platform, Battery Discharge Indicator, Battery Charger as approved, specified and directed by the Engineer.
Supplying, Installation & Commissioning Electro Hydraulic Dock Leveler with hinged swing lip having 60kN capacity, 6T DLC, 15T UDL , DL height 600mm, Lip length 400mm, Lip Angle ± 45mm, Platform Plate thickness 6/8mm, Lip Plate thickness 12/14mm, Main Cylinder 70mm, Working range ±350mm, Motor 0.75kW, Power Supply 400V/50Hz, Control Current 24VDC, Working Pressure ±100bar, Protection Class IP54, Colour RAL 9005 Black with CE Certification. Size : 2000 x 2500mm as approved, specified and directed by the Engineer.
Supplying, Installation & Commissioning of Hand Pallet Trolley of the folllowing spcifications: Operation Type: Pedestrian, Load Capacity: 1500kg, Load Centre: 600 mm Axle centre to fork face (Load distance): 947mm, Wheel Base: 1185 mm Wheels Type: Polyurethane , Wheel size: 210mm x 70mm, 80mm x 70mm, 80mm x 30mm No. of wheels: 1 x 4 x 2, Track Width at Load wheel: 380 mm Lift Height : 115 mm, Heiqht of tiller in drive position min I max: 700 I 1160 mm Lowered Forks Height: 80 mm, Overall Length: 1530 mm, Lowered Headlength: 380 mm Overall width: 540/685 mm, Fork dimension: 1150 mm x 160 mm x 47 mm Max. width across forks: 540 I 685 mm, Ground clearance at centre of wheelbase: 33 mm Aisle width with pallet 1000X1200 across forks: 2130 mm Aisle width with pallet 800X1200 along forks: 2000 mm, Turning Radius: 1330 mm, Travel speed: 4.6 I 4.8 Km/h, Lift speed: 0.02 I 0.025 m/sec, Lowering speed: 0.05 I 0.04 m/se c, Max. gradeability: 4 I 16 %, Service brake: EM, Drive motor, S2 60 min rating: 0.65 kW, Lift motor, S3 10% rating: 0.5 kW, Battery (Li- Ion): 24 v, 20 Ah, Battery weiqht: 4.6 Kg, Type of drive control: DC Speed Control, Sound level at driver's ear acc. to EN 12053: <70, Steering type: mechanical, Battery Charger: Included As approved, specified and directed by the Engineer.
Supplying, Installing and commissioning of Closed Circuit Television system of the following capacity including Supply and Laying of 2 Core 2.5 Sqmm Electrical Wire in PVC Conduit, Casing/ Caping with Supply & Installation of 6U & 17/18U Floor Mounted Equipment Rack complete with making necessary programming/ connections as approved, specified and directed by the Engineer. 4mp Dome Camera. 1/3" Progressive CMOS, ICR, Colour: 0.01 Lux @(F1.2; AGC ON), 0lux with IR, 2688x1520:25fps(P)/ 30fps(N), H.265+/H.265/H.264/ MJPEG, DC12V & PoE, WDR, 3D DNR, BLC, HLC, 5 VCA, IR range: up to 40m, HIK-Connect cloud service: (3Nos) 4mp Bullet Camera. 1/3" Progressive CMOS, ICR, Colour: 0.01 Lux @(F1.2; AGC ON), 0lux with IR, 2688x1520:25fps(P)/ 30fps(N), H.265+/H.265/H.264/ MJPEG, DC12V & PoE, WDR, 3D DNR, BLC, HLC, 5 VCA, IR range: up to 40m, HIK-Connect cloud service: (32Nos) 4MP Varifocal Camera. 1/3" Progressive Scan CMOS; H.265+/H.265/H.264+/H.264/MJPEG; Colour: 0.01 lux @(F1.2, AGC ON), 0 lux with IR; 25fps/30fps(2560x440, 1920x1080); 3 VCA functions; 3 streams; 3D DNR; ICR; EXIR, up to 50m; DC12V&PoE; Built-in micro SD/SDHC/SDXC slot; HIK- Connect cloud service: (11Nos) ANPR camera [Deep learning] 2MP smart monitoring camera, 1/1.9 Progressive Scan CMOS, 1920x1080 60fps/50fps; Lens:5.3-13mm: (2Nos) NVR 32Mbps Bit Rate Input Max(up to 64-ch IP video), 8 SATA interfaces, alarm I/O: 16/4, 2U case,19": (1Nos) 16 channel Gigabyte PoE Switch L2, Unmanaged, 16 Gigabit POE ports, 1 Gigabit RJ45 uplink port, 1 Gigabit SFP uplink port, 802.3af/at, PoE power budget 230w: (4Nos) Surveillance Grade Hard Disk Drive. ST6000VX001,6TB,5400,3.5": (8Nos) 4K LED Display of 55inch (min) with build-in speaker, view angle 178deg, plastic casing, VESA, 7*18h">55" 4K, HDMI*2, VGA*1, USB2.0, USB3.0: (1Nos)
A provisional sum of Rs 23,81,300.00 (Rupees Twenty Three Lakhs Eighty One Thousand Three Hundred Only) for ESMP requirements is provided and to be operated and expended in whole or in part as per the instruction of Engineer.
JC Construction Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid