Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.3 LAdmitted-Finance | -49.99% | ₹8.3 L | L1 | Admitted-Finance |
| 2 | L2₹11.5 L+₹3.1 L (37.3%)Admitted-Finance | -31.33% | ₹11.5 L+₹3.1 L (37.3%) | L2 | Admitted-Finance |
| 3 | L3₹13.3 L+₹5.0 L (59.5%)Admitted-Finance G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | -20.22% | ₹13.3 L+₹5.0 L (59.5%) | L3 | Admitted-Finance |
| 4 | L4₹14.2 L+₹5.8 L (70.1%)Admitted-Finance B 1124 SHASTRI NAGAR DELHI 110052 | NORTH | DELHI | 110052 | -14.95% | ₹14.2 L+₹5.8 L (70.1%) | L4 | Admitted-Finance |
| 5 | L5₹16.0 L+₹7.7 L (92.4%)Admitted-Finance N21 1 GROUND FLOOR SHIVPURI VILLAGE MEETHAPUR BADARPUR SOUTH DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | -3.80% | ₹16.0 L+₹7.7 L (92.4%) | L5 | Admitted-Finance |
Tender Value
₹16.7 L
EMD Value
₹33,358
Closing Date
11 Jun 2026, 3:00 pmClosed
EE,ELD-9,DDA
EE,ELD-9,DDA
Providing of temporary illumination at C/o trunk drain from Kirari to supplementary drain near Rithala, Rohini
2026_DDA_911661_1
08/EE/ELD-9/DDA/NIT/ 2026-27
Open Tender
Electrical Works
Works
90 days
Rohini
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹33,358
22 Jun 2026
5 Jun 2026
12 Jun 2026
5 Jun 2026
11 Jun 2026
5 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Operation & routine maintenance of temporary lighting arrangement by deploying Wireman Grade-II 01 No. from 6.00 p.m. to 06.00 a.m. as per inventory and terms & conditions enclosed herewith. | - | P/Day | 1,212 | - |
| 2 | Hiring of 100 Nos.wooden balli of height 4/6 mtr. i/c loading,unloading,transportation,fixing/grounding firmly tied by sutli/stay wire to bear the load of fittings/wires/cables along with rubber insulators,nailing for accompanying the wires/cables etc.complete as required. | - | P/Day | 2,374 | - |
| 3 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of (24-26 Watt)LED surface mounted Batten light of following body material on exisiting wooden balli and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body
(Thickness > 1.20 mm) | - | Each | 797 | - |
| 4 | Supplying and drawing 3 x 4 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel/ PVC conduit as required. the existing surface | - | Metre | 222 | - |
| 5Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||||
| 5.01 | Single pole | - | Each | 285 | - |
| 5.02 | Double pole | - | Each | 696 | - |
| 6Supplying & fixing following way, single pole & neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing testing & commissioning etc. as required.(But without MCB/RCCB/Isolator) | |||||
| 6.01 | 8 way , Double door | - | Each | 2,773 | - |
| 7 | Dismantling of 200 Nos.(24-26Watt) installed LED battens along with exisiting cables,wires,switchgear etc. i/c cartage and storage at DDA building Madhuban Chowk,Rohini. | - | Job | 233 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.39 MB
NIT08.pdf
Tender Documents • 1.63 MB
BOQ_958118.xls
BOQ • 0.30 MB
Corrigendum_1.pdf
PDF • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .