Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-Finance NOT SPECIFIED | ₹6.7 L | L1 | Accepted-Finance Bid Ok |
| 2 | L2₹6.7 L+₹2,130.45 (0.32%)Accepted-Finance | ₹6.7 L+₹2,130.45 (0.32%) | L2 | Accepted-Finance Bid Ok |
| 3 | L3₹6.8 L+₹13,782.59 (2.06%)Accepted-Finance NEAR ALCHI MONESTRY 00 01 SKANTSO ALCHI SASPOL ALCHI LEH LADAKH PIN 194106 | LEH LADAKH | LADAKH | 194106 | ₹6.8 L+₹13,782.59 (2.06%) | L3 | Accepted-Finance Bid Ok |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Categories of work not fulfill as per Enlistment |
| Sl No | Description | Qty | Unit | EAST URBAN ENGINEERING L2 | M/S DAWA ENTERPRISES L3 | M/S R P SINGH & COMPANY L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavatoin in trenches not exceedng 1.5 mtr wide but exceeding 1.5 mtr in depth for laying of pipe and getting out all in hard and dence soil, complete all as specified and directed by Engr-in-charge. | 262.08 | Cum | 306 ₹80,196.48 | 150 ₹39,312 | 120 ₹31,449.6 Lowest |
| 2.00 | Returning filling in including spreading watering and well ramming in layer not exceeding 25mm thick in hard dence soil, complete all as specified and directed by Engr-in-charge. | 235.87 | Cum | 28 ₹6,604.42 Lowest | 100 ₹23,587.2 | 34 ₹8,019.65 |
| 3.00 | Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed by Engr-in-charge. | 26.21 | Cum | 20 ₹524.16 Lowest | 250 ₹6,552 | 45 ₹1,179.36 |
| 4.00Taking up / down old DI/GI/PP-R tubing connection including clearing (from trenches), complete all as specified and directed by Engr-in-charge of following size: | ||||||
| 4.10 | (a) 20mm bore | 200 | RM | 12 ₹2,400 | 110 ₹22,000 | 5 ₹1,000 Lowest |
| 4.20 | (b) 25mm bore | 280 | RM | 12 ₹3,360 | 120 ₹33,600 | 5 ₹1,400 Lowest |
| 4.30 | (c) 40mm bore | 200 | RM | 13 ₹2,600 | 230 ₹46,000 | 5 ₹1,000 Lowest |
| 4.40 | (d) 50mm bore | 230 | RM | 13 ₹2,990 | 280 ₹64,400 | 5 ₹1,150 Lowest |
| 5.00 | Supply and fixing in replacement of 3-layer PP-R Polypropylene random copolymer concealed piper SDR 7.4 ((PN-16) VU stabilized and antimicrobial dusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings 20 mm outer dia with all fitting laid in trenches or fixed to walls and ceiling or laid in floor, complete all as specified and directed by Engr-in-charge.
Make : SFMC or equivalent | 100 | RM | 81 ₹8,100 Lowest | 110 ₹11,000 | 120 ₹12,000 |
| 6.00 | All as per srl item No 5 but outer dia 25mm, complete all as specified and directed by Engr-in-charge. Make : SFMC or equivalent | 250 | RM | 116 ₹29,000 Lowest | 150 ₹37,500 | 125 ₹31,250 |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
6 Aug 2026, 6:00 pmClosed
AGE (I) Nyoma
AGE (I) Nyoma PIN-901313 C/o 56 APO
Various repair / replacement of pipeline with connected items for Zone I and II under AGE (I) Nyoma.
2026_MES_778923_1
8100/NIT-14
Open Tender
Civil Works - Water Works
Item Rate
180 days
Nyoma
As per tender documents
9 documents required · 9 mandatory
₹500
AGE (I) Nyoma
₹15,000
2 Sept 2026
16 Jul 2026
8 Aug 2026
16 Jul 2026
6 Aug 2026
30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavatoin in trenches not exceedng 1.5 mtr wide but exceeding 1.5 mtr in depth for laying of pipe and getting out all in hard and dence soil, complete all as specified and directed by Engr-in-charge. | 262.08 | Cum | - | - |
| 2 | Returning filling in including spreading watering and well ramming in layer not exceeding 25mm thick in hard dence soil, complete all as specified and directed by Engr-in-charge. | 235.87 | Cum | - | - |
| 3 | Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed by Engr-in-charge. | 26.21 | Cum | - | - |
| 4Taking up / down old DI/GI/PP-R tubing connection including clearing (from trenches), complete all as specified and directed by Engr-in-charge of following size: | |||||
| 4.1 | (a) 20mm bore | 200 | RM | - | - |
| 4.2 | (b) 25mm bore | 280 | RM | - | - |
| 4.3 | (c) 40mm bore | 200 | RM | - | - |
| 4.4 | (d) 50mm bore | 230 | RM | - | - |
| 5 | Supply and fixing in replacement of 3-layer PP-R Polypropylene random copolymer concealed piper SDR 7.4 ((PN-16) VU stabilized and antimicrobial dusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings 20 mm outer dia with all fitting laid in trenches or fixed to walls and ceiling or laid in floor, complete all as specified and directed by Engr-in-charge.
Make : SFMC or equivalent | 100 | RM | - | - |
| 6 | All as per srl item No 5 but outer dia 25mm, complete all as specified and directed by Engr-in-charge. Make : SFMC or equivalent | 250 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tender14.pdf
Tender Documents • 1.14 MB
BOQ_872439.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .