Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.6 L+₹2.5 L (24.3%)Rejected-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L2 | Rejected-AOC l2 | |
| 3 | L3₹13.0 L+₹2.8 L (28.0%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹13.1 L+₹3.0 L (29.5%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L4 | Rejected-AOC L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Authorized dealer certificate from OEM not uploaded |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Oct 2022, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR/COMPREHENSIVE MAINT OF WINDOW TYPE ACS, SPLIT ACS, WATER COOLERS, REFRIGERATORS AND DEEP FREEZERS AT AFS YELAHANKA
2022_MES_555251_1
8112/E8
Open Tender
Civil Works
Item Rate
180 days
AF Stataion Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹20,000
Yes
9 Mar 2023
30 Sept 2022
24 Oct 2022
30 Sept 2022
22 Oct 2022
15 Oct 2022
Amount
Material and Labour for servicing of spilt type AC indoor/outdoor of capacity 1/1.5/2.0 TR of any make and type including following item of works: (a) Cleaning of complete unit including cooling coil condenser, Fan (Outdoor unit), blower etc. (b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc. (c) Checking of refrigerant piping and carrying out necessary repairs/replacement to copper tubing and insulation to copper tubing. (d) Checking of all components/accessories for their serviceability and replacement of defective components/accessories (e) Greasing and oiling of fan motor Note: (i) Replacement of unserviceable items wrt (d) above shall be measured and paid separately under relevant items.
All as per item No. 1 above but capacity 3 TR (2x1.5 TR) with 01 No outdoor unit and 02 Nos indoor unit complete all as specified and directed by Engr-in-Charge.
Material and Labour for servicing of Window AC 1/1.5/2.0 TR capacity including following items of works.:- (a) Cleaning of complete unit including cooling coil condenser, Fan(Outdoor unit), blower, etc as directed by Engineer-in-Charge. (b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc. (c) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. Note : (i) Replacement of unserviceable items wrt (c) above shall be measured and paid separately under relevant items . (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer as directed by Engineer-in-charge for functionality of AC is deemed to be included in unit rate quoted.
Maintenance/repairs and testing of Deep freezer of capacity 300/320/500 ltrs including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. Note: (i) Replacement of unserviceable itmes wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of Deep Freezer is deemed to be included in unit rate quoted.
Maintenance/repairs and testing of Water coolers of capacity 30 to 150 ltrs including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. (c) Cleaning of water storage tank. Note: (i) Replacement of unserviceable itmes wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of water cooler is deemed to be included in unit rate .
Maintenance/repairs and testing of Refrigerators of capacity 165 to 360 ltrs including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. (c) Cleaning of water storage tank. Note: (i) Replacement of unserviceable itmes wrt (b) above shall be measured and paid separately under relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of refrigerator is deemed to be included in unit rate quoted.
Supply & fixing new filter drier for 1.5 TR Split type AC capacity complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing new Air filter for 1.5 TR Split type AC capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing new filter drier for 3 TR (2 x 1.5 TR) Split type AC capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and in repair Plastic filter for window type AC 1.0/1.5/2.0 ton capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair new Air filter for 2.0 TR Split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of new filter drier for 2.0 TR Split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply & replacement of remote suitable for 1.5 TR capacity Split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply & replacement of remote suitable for 2.0 TR capacity Split type AC complete all as specified and as directed by Engineer-in-Charge.
M&L for repairs to remote mother board for 1/1.5 TR capacity Split type AC complete all as specified and as directed by Engineer-in-Charge.
M&L for repairs to remote mother board for 2/3 TR capacity Split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs compressor (sealed unit) of capacity 1.5 Ton suitable for installed in Window type Air conditioner complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and fix in repairs compressor (sealed unit) of capacity 1.5 Ton in exchange of unserviceable suitable for installed in 1.5 Ton Split type Air Conditioner complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of compressor (sealed unit) of capacity 2.0 Ton in exchange of unserviceable suitable for installed in 2.0 Ton Split type Air conditioner complete all as specified and as directed by Engineer-in-charge. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of compressor (sealed unit) of capacity 3.0 Ton in exchange of unserviceable suitable for installed in 3.0 Ton Split type Air conditioner complete all as specified and as directed by Engineer-in-charge. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of Compressor (Sealed unit) suitable for 150 Ltr. Water Cooler complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of Compressor (Sealed unit) suitable for 40/80 Ltr. Water Cooler complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of compressor (sealed unit) with relay suitable for refrigerator of capacity 310/315/320/325 litres complete all as specified and as directed by Engineer-in-Charge. Make of compressor TECUMESH / KIRLOSKAR / GODREJ)
All as per item No. 18 here-in-before above but for capacity of 180/230 ltrs capacity.
Supply and fix in repair Running capacitor 36 MFD 230 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge (Make : KELTRON / USHA / SIEMENS)
All as per item No 13 above but capacity of 45 MFD 230 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge (Make : KELTRON / USHA / SIEMENS).
Supply and fix in repair Running capacitor 25 MFD 230 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge (Make : KELTRON / USHA / SIEMENS).
Supply and fix in repair Starting capacitor 60 to 80 MFD 230 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge (Make : KELTRON / USHA / SIEMENS).
Supply and fix in repair Capacitor 4 MFD, 230 volts, 50 Hz. (Make : KELTRON / USHA / SIEMENS).
Supply and fix in repair Capacitor 2.5 MFD, 230 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge. (Make : KELTRON / USHA / SIEMENS).
Supply and fix in repair Starting capacitor 100 to 120 MFD 230 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge (Make : KELTRON / USHA / SIEMENS).
Supply and fixing of new running capacitor for 2 x 1.5 TR Split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of relay suitable for Window type AC 1.0/1.5/2.0 ton capacity complete all as specified and as directed by Engineer-in-Charge. Make : SRIRAM/Ranutrol.
All as per item No 29 above but split type A/C of capacity 1.5/2.0 TR complete all as specified and as directed by Engineer-in-Charge. Make : SRIRAM Model SR 1622 or equivalent of Ranutrol.
Supply and fix in repair over load relay suitable for Water cooler 40 to 60 ltr complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair box type relay suitable for refrigerator 165 to 310 ltr capacity complete all as specified and as directed by Engineer-in-Charge. Make : SRIRAM / Ranutrol/ Indfoss.
Supply and fix in repair relay 30 Amps capacity suitable for 4/5 KVA stabilizer omplete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of Thermostatic switch with knob suitable for window type AC 1.0/1.5/2.0 TR.(Make : INDFOS / RENUTRAL/Sriram)
Supply and fix in repair suction and discharge valve for 1.5/2.0 TR spilt type A/C complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.0/1.5/2.0 TR Window type Air Conditioner of various makes as per sample.
Repairs to Blower/Fan motor for 3 TR (2 x 1.5 TR) Split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of Fan motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR Split type Air Conditioner of various makes as per sample.
Supply and fix in repair Fan motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Split type Air Conditioner of various makes as per sample.
Supply and fix in repair Fan Motor Single phase,230V for water cooler complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR split type Air Conditioner (indoor unit) complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 ton split type Air Conditioner (indoor unit) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of new fan blower for 3 TR (2 x 1.5 TR) Split type AC complete all as specified and as directed by Engineer-in-Charge.
M & L for Rewinding of electric fan motor of 1.0/1.5/2.0 ton window type AC 1400 RPM 220 V 50 C/S with super enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
M & L Rewinding of electric fan motor of 1.5/2 ton split type AC (outdoor unit) 1400 RPM 220 V 50 C/S with supper enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
Supply and fixing of new swing motor for split type AC 1.5/2.0 Ton capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of front grill suitable for 1.0/1.5/2.0 ton window type Ac make Carrier Air con/Usha Sriram/LG compelete all as per site requirement and as per sample.
Supply and replacement of PCB suitable for 1.5/2 TR split type ACs as per site requirement and as per sample. Make : LG/Carrier/Blue star
All as per item No 13 above but for 3 TR split type ACs complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of contactor suitable for LG/Bluestar/Voltas/Carrier/Hitachi make Split type AC capacity 1.5/2.0 TR all as specified and directed.
Supply and replacement of evaporator coil for indoor unit of 1.5 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of condenser coil for outdoor unit of 1.5 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of evaporator coil for 2 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of condenser coil for outdoor unit of 2 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of blower for indoor unit of Split AC 1.5/2 TR complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of fan blade suitable for out door unit of Split type AC capacity 1.5/2.0 as per sample complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of fan blade suitable for window type AC capacity 1.0/1.5/2.0 as per sample complete all as specified and as directed by Engineer-in-Charge.
M&L for disconnecting electrical connection and dismantling/ taking out indoor and out door unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Supply, fixing, jointing and testing copper tubing with nominal dia meter of 0.25 inch of suitable thickness for liquid line to connecting out door condensing unit and fan coil unit complete all as specified and directed. (for 1.5/2.0 TR split AC).
Supply, fixing jointing and testing copper tubing with nominal dia meter of 0.5 inch and 0.8 inch thickness including expanded polythene foam insulation tubing for external insulation of suction line for connecting outdoor condensing unit and fan coil unit complete all as specified and directed (For 1.5/2.0 TR split AC).
Supply and fixing new Thermostat for water cooler storage type of capacity 30/40/60/120/150/180ltr/hour all as per sample.
Material and Labour for of base stand for fan motor from 2 mm thick MS sheet by welding and required nut bolts/washers as directed.
Supply and fix in repair Fan Motor blade complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Push type C.P. bib cock for water cooler complete all as specified and as directed by Engineer-in-Charge. Make : L & K/Leader
Supply and fix in repair float valve PVC for water coolers as per sample complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair water drain-out tray stainless-Steel of suitaible thickness for water cooler any make /size , with PVC waste pipe ,pipe clamp, complete as directed
Supply and Charging of Freon gas R-134/R-12 for Refrigerator/Water cooler and Deep Freezer complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Evaporator coil assembly for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Magnetic door gasket for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of freezer door for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and Charging of Freon gas R-22/R-410 for Acs complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of flexible Core PVC insulated with stranded copper conductor 2.5 Sqmm 4 core 600/1100 V ISI Marked complete all as specified and as directed by Engineer-in-Charge.
Supply and Replacement of PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Repairs to Voltage stabilizer of 1 KVA to 5 KVA capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric connection and carry out minor repair work such as repairing of internal worn out wires, repair to electronic circuit board, low/high cutoff circuit and replacement of unserviceable parts including testing by connecting on load and adjusting low/high cutoff and timing relay all as directed.
Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete suitable for 4/5 KVA all as specified and as directed.
Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete suitable for 01/2 KVA all as specified and as directed
Supply and fixing in repair Suction/Discharge valve for 3 TR (2 x 1.5 TR) TR Split type AC.
Supply and fixing in repair new lamp for Deep Freezers 500 Ltrs
Supply and fixing in repair new lamp cover for Deep Freezers 500 Ltrs
Supply and fixing in repair new lamp switch for Deep Freezers 500 Ltrs
Material and labour for core cutting on stone wall/concrete wall for inserting of copper tube and flexible copper cable for fixing of outdoor unit and making good to the distrubed surfaces also matching with the existing surfaces all as specified and as directed.
Glacier Cooling Solutions Private Limited
R Tech Mech
RAHUL ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .