| 1 | L1₹43.3 LAccepted-AOC | L1 | Accepted-AOC Successful Bidder | |
| 2 | L2₹45.4 L+₹1.2 L (2.62%)Rejected-Finance VIVEKANANDA PALLY NEAR MARUTI TEA FACTORY P O BAGDGORA DIST DARJEELING | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹46.2 L+₹2.0 L (4.48%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹46.9 L+₹2.7 L (6.12%)Rejected-Finance C O PULOKE NEOGI SURYA SEN PALLY PO KADAMTALA 734011 DIST DARJEELING WB | KADAMTALA | DARJEELING | WEST BENGAL | 734011 | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹47.0 L+₹2.8 L (6.30%)Rejected-Finance | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹41.8 L
EMD Value
₹83,600
Closing Date
31 Mar 2025, 6:00 pmClosed
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
RELOCATION OF EARTHING PITS AND OTHER WORKS AT WSA AT AF STN BAGDOGRA UNDER GE (AF) BAGDGRA
2025_MES_700888_1
8611/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF Bagdogra
As per NIT
10 documents required · 10 mandatory
₹500
GE AF Bagdogra
₹83,600
Yes
17 May 2025
10 Mar 2025
1 Apr 2025
10 Mar 2025
31 Mar 2025
24 Mar 2025
Amount
M&L in repair, test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw complete all as specified & directed.
Supply, fixing and brazing in repair of earth continuity conductor with adequate size insulator fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required 32mm x 6mm copper strip complete all as specified & directed.
Supply, fixing and brazing in repair of earth continuity conductor with adequate size insulator fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required 20mm x 3.15mm copper strip complete all as specified and directed.
M&L in repair, 40 mm bore GI pipe light grade ISI marked for earth strip protection with all fixing accessories for copper strip such as, nut bolts and washers insulator with necessary brick work for fixing GI pipe complete all as specified & directed.
M&L in repair, earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thickness burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl copper strip 20 x 3mm by means of nuts & bolts, check nuts and washers of brass incl PCC pit of 1:2:4, type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6 mm dia bar handle, earth pit angle iron frame of size 25 x 25 x 3mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20 mm dia with funnel and wire-mesh and medium grade GI protection pipe of 40 mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES SSR Part-I 2009 connected board all as specified and testing on completion. Note:- The earth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 4 core 16 sqmm complete all as specified & directed.
All as per item No. 6.00 above, but of size 4 core 25 sqmm complete.
All as per item No. 6.00 here-in-before, but of size 3.5 core 50 sqmm complete.
All as per item No. 6.00 here-in-before, but of size 3.5 core 120 sqmm complete.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick each layer in soft/loose soil complete all as specified and directed.
Removing excavated material/surplus soil and depositing where directed at a distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr from starting point complete all as specified and directed.
Supply, laying/ spread in trenches, river sand, clean, including spreading, levelling, punning as in cushioning of cables complete all as specified and directed. Note:- Punned depth will be measured and paid.
Supply and laying bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 complete all as specified and directed.
S&F PVC weather proof, hinged door, junction box with 240V, Neutral link, three phase connector, with IP 66/67 protection suitable for outdoor installation on pole/wall surface and including with 1 No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts etc including dismantling old unserviceable junction box complete all as specified and directed.
S&F distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways complete all as specified and directed.
S&F in replacement of MCB TPN 40 to 100 Amps, 415 Volts, 50 Hz with 10 KA 'C' curve complete with connection testing and commissioning complete all as specified and directed.
S&F energy efficient LED flood light luminaire, high PF, 150W, energy saving and environmental friendly and efficacy of not less than 110 Lm/w, long life versatile pressure die cast housing IP 66 protection, 240 V, using 2.5 Sqmm, PVC insulated sheathed three core copper conductor cable, 1100 V grade (upto 3.0 m) for connection etc as per site requirement, testing & commissioning and complete all as specified and directed.
S&F sheet metal enclosure (factory made), VTPN Vertical Distribution Boards, IP-43 & IP-44 protection suitable for MCCB's upto 125 A as incomer, double door, 8 way with 250 Amps rated copper busbar complete all as specified and directed.
S&F sheet metal enclosure (factory made), VTPN Vertical Distribution Boards, IP-43 protection suitable for MCCB's upto 125 A as incomer, double door, 4 way with 250 Amps rated copper busbar complete all as specified and directed.
Supply & Installation of advance conductive compound based chemical compound technology with upgraded high tensile low carbon steel rod as per UL 467 and as per BS 7430 with copper coating 250 microns. earthing system confirming to IS: 3034. The rod should 17.2 mm & 3 m length with rod to tape clamp, CR 125 (type A) additional protection of the terminal. Chemical compound should be the highly conductive compound as per BSEN 50164-7 with 25kg each bag & resistivity should be 0.05 ohm meter. The job includes digging the pit and refilling the same by fursecem back fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/ metal having mixed with 3:1 cement, a conductive concrete is formed. The earth pit should provided with a light weight inspection pit cover PT 205 for protection and safe guard of terminals. In areas where soil condition is bad, good earth is to be arranged to fill the excavated pits by mixing furse CEM a convenient and permanent solution by adding with 3:1 ration chemical compound with the earth electrode is the main component of the earthing system which is in direct contact with the ground and thus provides a mean of releasing or llecting earth leakage currents. The material should have good electrical conductivity and anti corrosion property in wide range of soil conditions. Make: ABB Furse CEM as per RB 336. Each earth pit should contain:- a) 1 No. copper bonded high tensile low carbon steel, 17.2 mm dia, 3 m length. b) Rod to tape clamp (type A). c) 25kg chemical compound as per BSEN 50164-74.) light weight inspection pit cover with 5000 kg weight load capacity. complete all as specified and directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
M/s Prakash Traders (BID ID -3273900)
M/s Chakraborty Enterprise (BID ID -3272679)
SHRI P P SHARMA (BID ID -3272962)
HALDER ENTERPRISERS (BID ID -3272003)
M/S P K ROY AND CO (BID ID -3273695)
RAMKRISHNA NARAYAN ROY & CO (BID ID -3273377)
M/S MANAS MITRA (BID ID -3272907)
UNISON CONSTRUCTION (BID ID -3272610)
BUILDERS ASSOCIATE (BID ID -3272825)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .