Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC | L1 | Accepted-AOC APPROVED | |
| 2 | L2₹3.4 L+₹12,172 (3.69%)Rejected-AOC 371 21 RBL ROAD NEW HYEDERABAD COLONY LUCKNOW UTTAR PRADESH 226007 | LUCKNOW | UTTAR PRADESH | 226007 | L2 | Rejected-AOC L2 | |
| 3 | L3₹3.5 L+₹16,648 (5.05%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹3.1 L
EMD Value
₹6,244
Closing Date
28 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
O/o The Executive Engineer ( Electrical) 1ST Floor, Bhopal House, Lalbagh Lucknow
OCM of EMS at TE Farrukhabad and staff qtrs colony .Awas Vikas,Farrukhabad SH Rectification of handing over defects on the risk and cost of M/s Awasthi Electric Works, Kanpur
2021_BSNL_84803_1
03/TEDL/BSNL/LKO/2021-22 Dated 07/06/2021
Open Tender
Electrical Works
Item Rate
60 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL Lucknow
₹6,244
20 Oct 2021
12 Aug 2021
30 Sept 2021
12 Aug 2021
28 Sept 2021
12 Aug 2021
90 days
SH:I Sub Station- Filteration of transformer oil of 2 x 315 KVA transformers and 3 Nos.HT breakers at site complete for dehydration increasing of insulation level and BDV more than 40KV for one minute by filter machine continuously day and night till rated BDV is obtained including break down voltage test of oil etc. complete as required.
Supplying & topping of transformer oil in transformer / HT OCB having break down strength of 40 KV for a minute at a distance of 4 MM. (Make Savilta / Power oil)
Servicing and repairing of existing faulty one no. HT Oil circuit breaker of rating (0-60) Amp, 11 KV (make GEC) i/c i/c replacement of spouts/bushes , cleaning with thinner, oiling greasing , testing etc. complete as required.
Servicing of one no. 11 KV/400 Amp. HT OCB / isolator (Make GEC) including overhauling of all main fixed/moving contacts, tightening of all parts,adjustments of operating mechanism for smooth operation,checking of all connections etc. complete as reqd.
Replacement of following faulty CT Operated 11 KV Amp. Meter of rating 0-60 Amp.size 144x144mm in the existing 11 KV HT OCB i/c connection, testing etc. complete as required1
Repairing of existing power pack unit (battery charger) for for HT Tripping & charger circuit i/c indication lamps, relays, doides etc. complete as required.
Supplying & fixing set of 4 nos. 12V 7AH maintenace free battery in existing battery charger box complete as required. (Exide make)
Cleaning of bus-bar trunking from transformer to MV panel by opening the cover, removal of dust and vermin by the blower,replacement of faulty insulators and gaskets tightening of all joints etc complete as reqd.
Replacement of following faulty accessories in the existing LT panel i/c connection, testing etc. complete as required. (a) LED type indicating lamps
(b) LED type indicating lamps
© 96mmx96mm size Volt meter of rating (0-500) Volt
(e) TPN SFU 63 Amp.(Make L&T, FN type or SS make)
SH:II EI Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required. (a) 36 Watt florescent tube rod
(b) 20 Watt florescent tube rod
© 11 Watt CFL
(d) 5 Amp. Piano type socket
(e) 40/20 W electronic choke
Rewinding & Repairing of ceiling fan / wall mounted fan / 300 mm Ex. fan 230 volt 50 hz AC supply & replacement of bush bearing, insulation , papering connection & testing etc as reqd
Rewinding & Repairing of 450mm sweep Exhaust fan 230 volt 50 hz AC supply & replacement of bush bearing, insulation , papering connection & testing etc as reqd
Re-filling of 4.5 Kg CO2 type fire extiguishers etc. complete as required. (Note: The refilling shall be done only at the authorized refilling centers)
SH:III PAC units Supply and fixing of 3 phase 415 volt outdoor condensor axial fan motor of dia 450mm i/c dismantling of the existing faulty motor, conections, testing etc. complete as required (Make: Highcool/Transmong/EBMPAPST or ss make)
Topping of refrigerant R-22 in the circuit of 7 TR precision controlled PAC units etc. complete as required.
Replacement of I no. compresser of existing 9TR uniflair make precision control package AC unit (Double circuit) i/c dismantling of faulty compressor cutting ,welding brazing etc as reqd. (Make : M/S Emerson Kopland model- ZR 72 or s/s make)
Replacement of faulty drier from the existing 9TR uniflair make precision control package AC unit (Double circuit) i/c testing etc. complete as required.(Model DCL165 or SS make).
Replacement of faulty 4 pole contactor of 18 Amp. rating with add on block from the existing 9TR uniflair make precision control package AC unit (Double circuit) i/c testing etc. complete as required.(Make L&Tor SS make).
Replacement of following faulty accessories in the existing AC plant panel i/c connection, testing etc. complete as required. (a) LED type indicating lamps
(b) 96mmx96mm size Volt meter of rating (0-500) Volt1
© HRC fuse of rating 63 Amp
(d) HRC fuse of rating 32 Amp
(e) Rotary handle of 63 Amp. SFU
Replacement of 63 Amp TPN FSU in the existing meter panel of block V i/c connection etc. complete as required.
Replacement of 63 Amp TPN FSU in the existing meter panel of block V i/c connection etc. complete as required
COOL CONTROL CORPORATION
SWASTIK ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .