| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC 47 C MODEL TOWN EXTENSION LUDHIANA PB | LUDHIANA | PUNJAB | 141001 | L1 | Accepted-AOC Due to lowest bid | |
| 2 | L2₹24.6 L+₹1.8 L (7.77%)Rejected-Finance | L2 | Rejected-Finance Due to higher bid | |
| 3 | L3₹26.1 L+₹3.3 L (14.7%)Rejected-Finance H NO 37 VIKAS VIHAR PHASE II FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L3 | Rejected-Finance Due to higher bid |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
CERTAIN BR REPAIR TO OFFRS MD ACCN AND OFFRS MESS UNDER AGE BR II OF GE (WEST) FEROZEPUR CANTT
2025_MES_706845_1
802025/GE-14/E8
Open Tender
Civil Works
Item Rate
270 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹50,000
Yes
14 Jul 2025
8 May 2025
11 Jun 2025
8 May 2025
4 Jun 2025
22 May 2025
Amount
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L rendering 15 mm thick cement plaster in cement mortar 1:4 on other than fair faces of brick or concrete work surfaces finished even and smooth (without using extra cement) mixed with integral water proofing compound as per manufacturer instructions complete all as specified and directed. Note: WPC shall be measured and paid for Separately under respective item.
M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces and finish the surface fair and even without using extra cement complete all as specified and directed.
M&L rendering 10mm thick cement plaster in cement mortar 1:4 fair faces of brick work or concrete surfaces and finish the surface fair and even without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick cement plaster in cement mortar 1:4 on top of roof surfaces finished even and smooth (without using extra cement) mixed with integral water proofing compound as per manufacturer instructions complete all as specified and directed. Note: WPC shall be measured and paid for Separately under respective item.
Supply only liquid water proofing compound (WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction) complete all as specified and directed.
M&L preparation of newly plastered ceiling surfaces and three coats white wash complete all as specified & directed.
M&L preparation of newly plastered wall surfaces and applying one coat of distemper oil emulsion over a coat of alkali resistant primer over a coat of wall care putty 3 mm thick complete all as specified and directed.
M&L preparation of new wall surfaces and applying two coats of colour wash over one coat of white wash complete all as specified and directed.
M&L preparation of old decorated surfaces of walls including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil, greasy spots and apply one coat distemper oil emulsion on walls complete all as specified and directed.
All as per Srl Item No 10 here-in-before but two coats of distemper oil emulsion complete all as specified and directed.
All as per Srl Item No 10 here-in-before but one coat of white wash on ceiling surface complete all as specified and directed.
All as per Srl Item No 10 here-in-before but one coat of white wash on wall surface complete all as specified and directed.
All as per Srl Item No 10 here-in-before but one coat of colour wash on wall surface complete all as specified and directed.
All as per Srl Item No 10 here-in-before but one coat of cement based paint on wall surface complete all as specified and directed.
M&L preparation of old painted wood surfaces, of any description, not otherwise described over 10 cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted steel surfaces, of any description, not otherwise described over 10 cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L applying bond coat of epoxy bonding agent & cement 1:1 ratio for bonding old and new concrete on damaged surfaces applying polymer modified mortar in CM 1:3 including mixing of polymer latex additive upto 60 mm thicknes (Chajja's fins,border etc) complete all as specified and directed. Notes :- (i) Quantity of polymer to used @ 15 % by weight of cement complete all as specified and directed. (ii) Use of electrical mixer to get homogeneous dough on bond coat surfaces complete all as specified and directed. (iii) To achieve required thickness repeat this step after 24 hrs to as required complete all as specified and directed. (iv) Keep the surface moist using water fog for 5 to 7 days etc complete all as specified and directed. (v) Rate shall be inclusive of all necessary scafolding for building hieght up to 24 meter complete all as specified and directed. Makes :- Epoxy bonding agent shall be Krishna. Dr Fixit, MC Bauchenie and M/s Chemistim, Sika or Equivalent complete all as specified and directed.
M&L for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WC's etc shall be as under :- (i) Application of Two component Acrylic modified Cementitious coating (aa) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface contamination. The installation instructions in manufacturer's published literature should be strictly complied with including but not limited to the following:- (bb) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr Fixit 302 SBR late Perma latex SBR / FOSROC Nitabond SBR latex / Asian Paints latex as required. Final cleaning surface with power grinder, wire brush, hair brush & vacuum pressure if required. (cc) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating Sika Top Seal - 107/ Brush Bond FOSROC/ Dr Fixit/ STP/CICO. (dd) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic mo Cementitious coating of Sika Top Seal - 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of vis as per manufacturer's instructions.
(ee) Apply Glass Fabric Sheet of Sika Fab 1/FOSROC/ Dr Fixit/ STP whilst the first coat is wet. (ff) Once touch dry, apply second coat of Acrylic modified Cementitious coating of Sika Top Sea /Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer's instructions entire area. (gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direct angle to the previous coat. (hh) The waterproofing coating should be taken to a height minimum 300 mm above the floor finish level on the vertical surface. (jj) It is essential to cure Acrylic modified Cementitious coating immediately after application 3-8 Hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize (kk) A protection plaster (12-15mm thick) in CM 1:3 admixed with appropriate Integral water Compound has to be applied on the walls Admixture :- Sika plastocrete plus/FOSROC/Dr Fixit/STP/CICO confirming to IS 2645 Providing and applying a protection screed of 50 mm thick 1:4 cement sand mortar admixed with Sika plastocrtete over applied water proffing coating on horizontal surface. Admixture :- Sika plastocrete plus/FOSROC/Dr Fixit/STP/CICO confirming to IS 2645 (ii) All the corners and joints should be pretreated with elastic waterproffing sealing tape with a woven bonding on each surface an elastic expansions zone in the centre of make sika Tape S/FOROC/Dr Fixit/STP
(mm) The membrane has to be protected in accrodance with the manufacture's recommendance until placemnent of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accrodance with manufacturer's recommendations. (nn) Waterproofing treatement has to carried out through applicators authorisrd. (ii) All the joints of pipesand traps within sunken portion shall be sealed properly by Epoxy sealant. (iii) All CI traps in sunken slab to be enclased with PCC 1:1:5:3 ( Min 15 cm) all - round. (iv) the sunken portion shall be filled with PCC 1:5:10 type E-2 ( using 40 mm stone aggregate ) complete all as specified. (v) Providing drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall ( approx 450 mm to 600 mm long ) including cutting to existing wall and making good the distrubed surface complete all as specified and directed. (vi) Providing 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm grade stone aggregate as in flooring for laying fllor finish all as specified. Note ;- Item No 22 (iv) ,(v) & ( vi) shall be measured and paid seprately.
Taking up or down steel tubing and connection 15 mm dia bore complete all as specified and directed
Taking up or down steel tubing and connection 20 mm dia bore complete all as specified and directed
S&F Unplasticised PVC pipes 15mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed
S&F Unplasticised PVC pipes 20mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed
S&F in repair vitreous China wash down water closet pan (pedestal pattern) white,incl. trap, connection to drain and flushing pipe including seat cover for pedstal pan complete all as specified and directed.
S&F in repair vitreous China squatting pan, ' Orissa patteren, size 580mm x 440 mm white, with integral footrests (excluding flushing cisteren and flush pipe) complete all as specified and directed.
S&F in repair vitreous China wash basin white, flat back,size 550mmX400 mm including cutting for pinning in ends of brackets complete all as specified and directed.
S&F in repairs 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed.
S&F as in repair 15 mm bore fancy type chromium plated stop/angular valve screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F as in repair 15 mm bore fancy type chromium plated concealed stop cock (regular body) fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair PVC connection 15mm size PTMT nuts of length 450 mm complete all as specified and directed.
S&F as in repair 15 mm bore fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair for 15 mm bore fancy type wall mixer with 115 mm long bend pipe for connection to with aerator complete all as specified and directed.
S&F in repair for fancy type 15 mm bore central hole basin mixture with 'U' shaped round casted spout with 3" long pipe connection with aerator complete all as specified and directed.
S&F in repair fancy type Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&Fin repair fancy type aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repair Soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and directed.
S&F in repair Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F in repair chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified & directed.
S&F in repair 15 mm bore Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair PVC cabinet mirror of size 450mmx 600 mm complete all as specified and directed.
S&F in repair water closet seat cover any coloured pattern with flat bottom and mild steel chromium plated or aluminium hinging devices complete all as specified and directed.
S&F in repair sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410 mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs Stainless steel sinks made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers& waste pipe, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm X 420mm with bowl size 410mm X 330mm X 160mm complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples complete all as specified and directed.
Hacking out old broken glass (any thicknesss, size,quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
M&L sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm each pane 3 mm thick complete all as specified and directed.
M&L figured glass pin headed ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm each pane 3 mm thick complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as specified and directed.
M&L Non-Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L Non-Skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
All as per Srl item No 52 here-in-before but in skirting including rendering 10 mm thick on fair faces of brick work in cement mortar 1:4 to receive wall tiles etc complete all as specified and directed.
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortat 1:6 for laying floor finishes complete all as specified and directed.
All as per Srl item No-54 here-in-before but in skirting including rendering 10 mm thick on fair faces of brick work in cement mortar 1:4 to receive wall tiles etc complete all as specified and directed.
M&L glazed tiles digital coloured ceramic tiles 350mmx 250mm/ 450mmX 350mm and 7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match including rendering 15 mm thick on fair faces of brick work in cement mortar 1:3 to receive wall tiles etc complete all as specified and directed.
S&F in repair 20 mm dia decorative type curtain rods chromium plated anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and directed.
S&F in repair 100 mm butt hinges medium weight cold rolled stainless steel complete all as specified and directed.
S&F in repair 75 mm butt hinges medium weight cold rolled stainless steel complete all as specified and directed.
S&F aluminium anodised 200 mm barrel tower bolts of extruded section complete all as specified and directed.
S&F aluminium handle 150 mm cast type anodised complete all as specified and directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
Taking down shutters of any description not exceeding 1.00 sqm each complete all as specified and directed.
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each complete all as specified and directed.
Taking down Chowkhats or frames exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and directed.
Taking down Chowkhats or frames with shutters (without taking of shutters from the frame) not exceeding 1.50 Sqm each complete all as specified and directed.
S&F 105mm x 60 mm size pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F 125mm x 60 mm size pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F powder coated of any colour (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated of any colour (thickness or powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S&F 10 mm thickToughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed.
S&F solar control film 25 micron reflective type sticked to glass panes exc. 1.50 sqm as per instructions of manufacturers complete all as specified and directed.
M&L for cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in hold fast , bed plates, fillling of pressed steel chowkhats and all other similar works complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and directed.
S&F 2nd class hardwood 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
S&F 2nd class hard wood 30mm thick glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc(without sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securing gauge,etc sizes of member of shutter as specified SSR part-I Section 8 clause 8.24 (a) and fitted to chowkhats complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19mm x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified.
S&F in repairs veneered particle board 18 mm thickness, solid core, exterior grade, with decorative face veneers on both faces as in cup board & kitchen cabinet shutters and all other similar works complete all as specified and directed.
S&F in repairs continuous (piano) hinges, mild steel, bright finish or electrogalvanised, 30 mm width of flaps (when open) complete all as specified and directed.
S&F aluminium anodised 150 mm barrel tower bolts of extruded section complete all as specified and directed.
S&F aluminium anodised 75 mm barrel tower bolts of extruded section complete all as specified and directed.
S&F aluminium handle 100 mm cast type anodised complete all as specified and directed.
S&F 100 mm long Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
Resecuring or easing & adjusting, without taking down shutters of any description exc 1.00 sqm but not exceeding 2.00 sqm complete all as specified and directed.
M&L for preparation of new wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Dismantling brick tiles or terracing tiles laid in single layer on roofs jointed and pointed in cement mortar complete all as specified and directed.
Demoltion of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
M&L 10 mm thick screed bed or bedding layer of mortar in cement mortar 1:4 with water proofing compound @3% by weight of cement or as per manufacturer instructions will be on surface to have a smooth surface for laying of water proofing membrane. Note: WPC shall be measured and paid for separately under respective item.
Supply only water proofing compound complete all as specified and directed.
M&L applying one coat of cold applied polymeric modified bituminous primer @ 0.30 Kilogram per square metre including preparation of roof surfaces complete all as specified and directed.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
M& L APP Membrane to be finished with one coat of solar reflactive bituminous based aluminium Paint @ 0.1 kg per sqm complete all as specified and directed.
M&L 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar 1:3 mixed with 5 % of crude oil by weight of cement on mud phuska and pointed flush as work proceeds complete all as specified and directed.
M&L except tiles for 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar 1:3 mixed with 5 % of crude oil by weight of cement on mud phuska and pointed flush as work proceeds complete all as specified and directed. Note :- Old brick tiles retrieved from dismantling of treatment here-in-before shall reused after cleaning and the quoted rate shall deemed inclusive of cleaning and making suitable for relaying.
Demolition of cement concrete in ground floor & paving not exceeding 15 cm thick (below or above GL) unreinforced complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection, shall be laid in 1:20 slope. The concrete shall be laid at a stretch not exceeding 3-meter in length. Joint gap between the adjoining slab, at corners and at junctions of wall shall not exceed 10mm in width and shall be sealed with mastic filling i.e. one part of bitumen of grade 85/25 garde mixed with 3 part of sand. Top surface of concrete shall be finished even and smooth without using extra cement. Joints shall be provided at not more than 3-meter interval at corner and junction walls complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & directed.
M&L granite (of any colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, flooring and all other similar works including 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L 75mm thick PCC 1:4:8, type D-2(using 40mm graded stone aggregate) as in sub base etc complete all as specified and directed.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, driveways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Dismantling PVC water tanks capacity exceeding 250 Ltr but not exceeding 500 Ltr complete all as specified and directed.
Dismantling PVC water tanks capacity exceeding 500 Ltr but not exceeding 1000 Ltr complete all as specified and directed.
S&F 500 ltrs capacity triple layered rotational moulded polyethylene water storage tanks (cylinderical vertical wit closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F 1000 ltrs capacity triple layered rotational moulded polyethylene water storage tanks (cylinderical vertical wit closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Demolition and breaking up drain pipes upto 110 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed
S&F 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls complete all as specified and directed.
S&F 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes laid in trenches including making good to the excavated surfaces complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes laid in trenches complete all as specified and directed.
S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed.
All as per Srl item No 110 here-in-above but with access doors complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends with access doors any radius complete all as specified and directed.
S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
Demolition of ceiling boards of any description, and any thickness including cover fillets and frame work complete all as specified and directed.
M&L anodised aluminium snap grid frame work for false ceiling complete all as specified and directed.
M&L fancy designed 6 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid complete all as specified and directed. Note:-frame work for ceiling shall be measured and paid for separately under respective item.
S&F in repair to Hollow PVC wall lining consisting of 5mm thick single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement and fixing on PVC frame as per specified in MES schedule part-I & II complete all as specified and directed.
S&F in repairs door closer of aluminium dia cast body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F in repair door bottom seal aluminium plate with black rubber, 3 feet length complete all as specified and directed.
Disconnecting existing tanks exceeding 250 ltr but not exceeding 500 ltr , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified. Note :- Bleeching powder to be spread in the bottom of tank before fixing / installing in position and the cost of bleeching powder shall deemed inclusive of quoted rate.
Disconnecting existing tanks exceeding 500 ltr but not exceeding 1000 ltr , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified. Note :- Bleeching powder to be spread in the bottom of tank before fixing / installing in position and the cost of bleeching powder shall deemed inclusive of quoted rate.
S&F grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gm) complete all as specified and directed.
S&F grating round 140 mm size of PTMT. (Minimum weight 50gms) complete all as specified and directed.
All as per Srl item No-123 here-in-before but with waste hole of PTMT (Minimum weight 100gms) complete all as specified and directed.
S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore dia of outlet of pipe complete all as specified and directed.
Dismanlting Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layer not exceeding 25cm hard and dense soil complete all as specified and directed.
M&L cement concrete type C-2, 1:3:6 (using 40 mm graded aggregate) in foundation filling mass concrete for post holes etc complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde-E- 250) quality-A complete all as specified and directed.
M&L pre painted galvatume aluminum zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L deep cleaning of the house not exceeding 140 sqm of plinth area including all rooms, cupboards, IWCs/ EWC, bathroom and kitchen (incl. sink, cupboards etc). All stains/spots from the whitewash/ any other source to cleaned completely using suitable washing chemical and broom/mop. The garbage obtained during cleaning to be removed and disposed at a distance not exceeding 100m from the bldg complete all as specified and directed. Notes:- (i) The Labour/ Safaiwala employed by the contractor shall be in possession of appropriate tools/items required for cleaning. (ii) The Contractor shall deploy suitable Nos of Labours/ Safaiwalas for cleaning and the work should be completed within 48 hours of commencement. (iii) The rate is inclusive of cleaning chemical and tools required for cleaning. (both to be provided by the contractor) (iv) The cleaning will checked by JE/ Engr-in-charge and if any shortcomings are highlighted during the visit, the contractor will have to rectify the same within 24 hours.
Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) complete, fittings such as switches, ceiling roses, pendants, regulators sockets light fitting etc removing materials to store for keetping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls , floors ,etc complete all as specified and directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store complete all as specified and directed. Note:- Serviceable items shall be reused and the same shall be measured and paid for separately under respective items.
M&L Point wiring complete with 1100 volts grade PVC insulated unsheathed FRLS cable of copper conductor, multi stranded of size 1.5 sqmm, single core, in and including new rigid non-metallic PVC conealed conduit, with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and new MS pressed steel / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire of size 1.5 sqmm unsheated stranded copper conductor with green PVC insulation connected to common earth dolly for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch complete all as specified and directed.
(b) One socket outlet on the same board controlled by one single pole one way switch complete all as specified and directed.
(c) One 5 Amps socket outlet independent controlled by one single pole 5 Amp switch complete all as specified and directed.
All as per Srl Item No 135 here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 Sq mm PVC insulated copper conductor and 2.5 Sqmm copper conductor for continuous earthing complete all as specified and directed.
All as per Srl item No 135 here-in- before but existing conduit and existing Ms pressed steel/ cast iron box . (a) One light point/fan/bell point controlled by one single pole one way switch complete all as specified and directed.
(b) One 5 Amps socket outlet independent controlled by one single pole 5 Amp switch complete all as specified and directed.
All as per item No 138 here-in- before but existing conduit and existing Ms pressed steel/ cast iron box complete all as speicifed and directed.
S&F new MS pressed steel/cast iron sunken boxes rectangular block in relacement of old rusted sunken box. The MS Pressed Steel/ CI Box shall be galvanised or painted black with two coats of black bituminous paints or any other paint as indicated .The MS pressed steel/cast iron sunken boxes should be suitable for mounting of normal/modular switches, sockets, fan regulator etc and the item rate quoted also including making good the disturbed surfaces to match with the existing surface. The new MS pressed steel/cast iron sunken boxes suold be of following sizes with suitable thickness as per IS Code. (a) 8" x 10" and Suitable for Main switch board complete all as specified and directed.
(b) All as per Srl item No 142 here-in- before of size 7"x4" and Suitable for 15 Amp Independent board complete all as specified and directed.
(c) All as per Srl item No 142 here-in- before but of size 4"x4" and Suitable for 05 Amp Independent board complete all as specified and directed.
S&F bakelite sheet hylam 3mm thick of white top fixed with cup washers, machine screws on new/existing MS Shuken box including removing existing switch/ switch sockets/ bell push etc and refixing the only servicable switchs/socket by making slots on new sheet. (a) Min approx size 9"x11" and Suitable for Main switch board complete all as specified and directed.
(b) All as per Srl item No 145 here-in- before but of Min size 8'' x 5" and Suitable for 15 Amp Independent board complete all as specified and directed.
(c) All as per Srl item No 145 here-in- before but of Min size 5'' x 5" and Suitable for 05 Amp Independent board complete all as specified and directed.
S&F in repair Switch piano flush type single pole one way 5/6 Amp complete all as specified and directed.
S&F in repair Switch piano flush type 15 Amps, single pole one way duly ISI marked complete all as speicifed and directed.
S&F in repair Socket outlet 2 in one , 5/6 Amps flush type ISI marked complete all as speicifed and directed.
S&F in repair complete all as speicifed and directed. air Socket outlet, 2 in one 6 pin 5 and 15 Amps piano flush type ISI marked complete all as specified and directed.
Fixing only servicable Switch piano flush type single pole one way 5/6 Amp obained from Item srl No 134 complete all as specified and directed.
Fixing only servicable Switch piano flush type 15 amps, single pole one way duly ISI marked obained from Item srl No 134 complete all as specified and directed.
Fixing only servicable Socket outlet 2 in one , 5/6 Amps flush type ISI marked obained from Item srl No 134 complete all as specified and directed.
Fixing only servicable Socket outlet, 2 in one 6 pin 5 and 15 Amps piano flush type ISI marked obained from Item srl No 134 complete all as specified and directed.
S&F in repair Ceiling rose surface type, PVC/polycarbonate , isolated, bakelite 65mm x 50mm, 3 terminals ISI marked complete all as specified and directed.
S&F in repair Lamp holder insulated body threaded dome pattern,suitable for bracket / batten fitting complete all as specified and directed.
S&F in repair stepped type electronic fan regulater flush, socket type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed.
S&F in repair bell push piano flush type 5 Amps single pole duly ISI marked complete all as specified and directed.
S&F in repair bell ding dong AC 230 volts single pole complete all as specified and directed.
S&F in repair Modular Switch one way 6 A, 1 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&Fin repair Modular Switch one way 16 A, 1 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular Socket,6A - 2/3 pin combined 2 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular Socket,6A16A - 2/3 pin combined 2 module complete all asper specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular white cover plate with frame , 1 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular white cover plate with frame, 2 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular white cover plate with frame, 3 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular white cover plate with frame, 4 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular white cover plate with frame, 6 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular white cover plate with frame, 8 module complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular Metal flush box 1/2 module , complete all as per specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular Metal flush box 3 module , complete all as per specified and directed. Makes- Precision/Anchor/Havells/Legrand
S&F in repair Modular Metal flush box 4 module , complete all as specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular Metal flush box 6 module , complete all as specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular Metal flush box 8 module , complete all as specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular Bell push 6A, 1 module complete all as specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair Modular step type regulator,120 W - 2 module complete all as specified and directed. Makes - Precision/Anchor/Havells/Legrand
S&F in repair LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repair LED tube light fitting 9 watts batten type fixed on wall/ ceiling etc. including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F LED Bldg Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
S&F decorative gate light/garden light made up of high grade unbreakable polycarbonate material suitable for LED Lamp (B22) - Moon 200 base suitable for mounting Pole Dia - 60 mm (max) OD. Dimension: Width: 200 mm & Height: 227 mm for Moon 200 decorative gate light all as specified and directed.
S&F LED Driver for LED Bldg security light/ceiling light upto 45 W including all connection and suitable size of copper wire complete all specifed and directed. Makes: Cat part No S0DQL-65-700-45W of Crompton or techno-commercially equivalent in approved makes.
S&F in repair sheet metal enclouser SPN DB's 8 way double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series, 240 volts 200 Amps rated enameled bus bar 8 way dust and vermin proof ssuitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified and directed.
All as item No 184 above but SPN DB's 4 way complete all as specified and directed.
S&F in repair sheet metal enclouser DB's TPN 4 way double door(Vertical Type) factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series, 415 volts 200 Amps rated enameled bus bar 4 way dust and vermin proof ssuitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified and directed.
S&F MCCB 63 Amps 415 Volts 16KA breaking capacity complete all as specified and directed.
S&F MCB TPN 415 volts 63 Amps, 10 KA breaking capacity complete all as specified and directed.
S&F MCB single pole neutral (SPN) 240 volts, 40 Amps, 10 KA complete all as specified and directed.
S&F MCB single pole (SP) 240 volts, 6 to 32 Amps, 10 KA complete all as specified and directed.
S&F in repair sub main wiring of 6 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor with earth wire of 6.0 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor including PVC conduit pipe 25 mm dia complete all as specified and directed. Note:-Two run of single core 4 sqmm cable and one run single core 6.0 sqmm cable for earth wire and including conduit pipe 25 mm dia shall measured as one length.
M/s Bansi Lal (BID ID -3312278)
Karan Engineers (BID ID -3312632)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .