Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹47.3 L Quoted ₹48.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹53.9 L+₹5.0 L (10.3%)Rejected-Finance | ₹53.9 L+₹5.0 L (10.3%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹54.9 L+₹6.0 L (12.2%)Rejected-Finance | ₹54.9 L+₹6.0 L (12.2%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹55.5 L+₹6.6 L (13.5%)Rejected-Finance CHOTHRAPUR BRICHGUNJ POST PORT BLAIR SOUTH ANDAMAN 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹55.5 L+₹6.6 L (13.5%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹56.5 L+₹7.6 L (15.5%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹56.5 L+₹7.6 L (15.5%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Jan 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat post Minniebay Port Blair 744103
REPAIRS AND MAINT RAISING MAIN PIPE LINE, SLUICE VALVE, AIR RELEASE VALVES CI/DI PIPE LINE FROM CHOULDARI DAM TO MINNIE BAY, CLEANING OF UG SUMPS AND SEMI UG SUMPS AND OTHER ALLIED WORKS AT NTS MARCOS PROTHAPUR CHOULDARI UNDER AGE E/M-II AT GE MINN
2023_MES_572739_1
8208/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
as per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹96,000
Yes
4 Mar 2023
3 Jan 2023
27 Jan 2023
4 Jan 2023
24 Jan 2023
18 Jan 2023
Amount
Cleaning and replacement of existing filter media (capacity 15000gallons/hr) materials such as fine sand, core sand,fine silica,core silica, small, medium and large aggregates and provision of new materials of fine sand, core sand and gravels,pebbles in filter bed. Cleaning of sedimetation with bleaching powder slurry and clear water including discarding of unusable filter media and disposing off same to a distance exc 500m and exc 1km fron MD land, scrapping the internal surface of filter bed with wire brush, cleaning with bleaching powder slurry, finally cleaning all the surfaces with fresh water and refilling up of complete all as specified and directed. Filter bed size - (3.9mx3.00mx1.32m)-03 Nos Note :(i) New items such as fine sand, core sand, gravel & Pebbles shall be measured and paid under relevant items in this schedule as "Supply only" (ii) Evidences / Purchase voucher from government authorised agency for supply of filter media material shall be submitted along with MTC for payment and record.
Supply only for fine sand 0.8 to 1.6mm size
Supply only coarse sand
Supply only gravel & pebbles 10mm size
Supply only gravel & pebbles 15mm size
Supply only gravel & pebbles 20 to 35 mm size
Supply only gravel & pebbles 35 to 45 mm size
Supply only gravel & pebbles 45 to 65 mm size
M&L for tyton joints of 200 mm dia using rubber gasket ISI marked suitable for spigot and socket pipes and fittings for CI / DI complete all as specified and as directed by Engineer-in-Charge.
M&L for tyton joints of 350 mm dia using rubber gasket ISI marked suitable for spigot and socket pipes and fittings for CI / DI all as specified and directed.
M&L for tyton joints of 400 mm dia using rubber gasket ISI marked suitable for spigot and socket pipes and fittings for CI / DI all as specified and directed.
M & L in replacement CI/DI fittings/specials of any size from 80 mm to 400 mm for spigot and socketed pipes of class 'A' such as bends any type, radius and angle, tapers any type (straight, bend, increasing / decreasing or double socket etc..) tee pieces, single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc,.. in new position with connecting pieces for pipes 400mm bore CI/DI pipe line complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement cast iron sluice valve class PN 1.6 heavy duty ISI marked both ends flanged, suitable for following bore conforming to IS 14846 of 2000 duly with wheel operated handle with high tensile stainless steel spindle including nuts, bolts, washers etc of required size including taking out old existing unserviceable sluice valve and making arrangement for safe working complete all as specified and as directed by Engineer-in-Charge.
80mm dia bore
100mm dia bore
150mm dia bore
200 mm dia bore
250mm dia bore
300mm dia bore
350mm dia bore
400mm dia bore
Supply and fix in replacement of flanged Non return valve ISI marked flap type, cast iron body, PN1.6,confirming with relevant IS provision of 3mm thick rubber gasket on both sides of the flanges, bolts and nuts complete including dismantling of unserviceable valve complete all as specified and as directed by Engineer-in-Charge of following sizes;
150 mm bore
200 mm bore
M&L for Servicing of Sluice valve by removing the nut and taking out the spindle for turning work in lathe workshop for replacement of necessary spare parts and refixing the spares at original position after servicing complete all as specified and directed by Engineer-in-Charge for the following sizes:-
150mm bore
200/250 mm bore
350/400 mm bore
M&L for attending break down, excavation and earthwork in mud by using earthmoving machinery (Hitachi)/labour to a length of 10 m approx (from chouldhari to Minniebay Pump House) and forming bund with excavated Hard/soft soil to avoid sea/raw water intrusion into the working area including pumping/bailing out water by using portable diesel engine driven pump set complete all as directed and including the following :- (i) Cutting of CI/DI pipe of size up to 400/350/300 mm dia after thorough inspection for the damage including bailing out water using portable pump set. (ii) Taking out DI pipe after removing from tyton joints at both ends with the help of Hitachi and keeping aside for further disposal. (iii) Transporting DI pipe of size up to 400/350/300 mm dia to the site from Chouldhari dam, cutting the pipe into two pieces as per requirement and laying into the trenches using machinery. (iv) Jointing by using rubber tyton rings up to 400/350/300mm dia pipe to the corresponding socket and spigot ends of the existing pipeline after aligning the pipe line as per site condition, inserting the CI collar of size 400/350/300 mm dia complete all as specified and as directed by Engineer-in-Charge.
Note : (i) The rate is deemed to include cost towards tools and plants and transportation required for attending the repair work. (ii) The rate deemed to inclusive of soil additional required to refilling/ making bunds to prevent sea water entering into the work place complete. (iii) The cost of pipes, specials, Tyton/lead joints shall be measured and paid separately under relevant item of this schedule.
M & L for precast cement concrete 1:2:4 type B2 Nominal mix using 40 mm graded stone aggregates as in mass concrete/foundation/for supporting (encasing) of DI pipes of any size and in any position including plastering of surfaces complete all as specified and directed
M & L for precast cement concrete 1:3:6 type B1 Nominal mix using 20 mm graded stone aggregates as in mass concrete/foundation/for supporting (encasing) of DI pipes of any size and in any position including plastering of surfaces complete all as specified and directed
Supply and fix in replacement of Cast iron foot valve ball type ISI marked Heavy duty cast iron body conforming to relevant IS provisions fitted in position including rubber/leather gasket, nuts & bolts and washers with synthetic metal ball complete including dismantling of unserviceable valve complete all as specified and as directed by Engineer-in-Charge for the following sizes:-
200 mm dia
250 mm dia
M & L for grass cutting with the help of Petrol Grass cutting machine all around the installation of Chouldhari dam area and Prothrapur area complete all as specified and as directed by Engineer-in-Charge. Note : (i) The grass cutting machine shall be provided by the contractor (ii) The rate is deemed to include cost towards tools, fuel and transportation required for attending the vegetation work.
Supply & Fix in replacement Line contactor MNX 250 Cat part No. CS94140 Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz. complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix in replacement Line contactor MNX 185 Cat part No. CS94140 Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz. complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing of Mechanical joint of size 350mm bore (rubber) with bolts, nuts, washers for pipe line leakages complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing of Mechanical joint of size 400mm bore (rubber) with bolts, nuts, washers for pipe line leakages complete all as specified and as directed by Engineer-in-Charge.
M&L for repair Maintenance of Soft starter for capacity of 165 HP/ 125KW motor, repair to inbuilt bypass contactor, soft starter with built in Key pad by pass relay & 220-240 v control voltage soft stop/adjustable current essential motor protections against, over load, single phasing instantaneous over current phase sequence reversal Abnormality in supply, thermister protection.EMX3 are based 400% starting current 6 seconds/Hr 37 KW & above 6 seconds starting time Ambient temp 45 etc complete all as specified and as directed by Engineer-in-Charge.
M&L for repair Maintenance of Soft starter for capacity of 170 HP/ 125KW motor, repair to inbuilt bypass contactor, soft starter with built in Key pad by pass relay & 220-240 v control voltage soft stop/adjustable current essential motor protections against, over load, single phasing instantaneous over current phase sequence reversal Abnormality in supply, thermister protection.EMX3 are based 400% starting current 6 seconds/Hr 37 KW & above 6 seconds starting time Ambient temp 45 etc complete all as specified and as directed by Engineer-in-Charge.
Disconnection electrical connection of pressure pump of RO Plant capacity 7.5HP/5.5KW and taking out complete assembly with electric motor, transporting to workshop and testing the complete and refixing with new nuts, bolts & washers and same as fitting the existing position and commissioning, testing for smooth running condition complete all as specified and as directed by Engineer-in-Charge. Note : Cost of spares shall be measured and Paid separately under relevant item.
Supply only filter 4x30", capacity 3000ltrs/hr as per existing filter in RO Plant along with rubber ring complete all as specified and as directed by Engineer-in-Charge.
Supply only micron filter of size 2.5x30", capacity 3000ltrs/hr as per existing filter in RO Plant along with rubber ring complete all as specified and as directed by Engineer-in-Charge.
Supply only sand filter Media (MSF) of capacity of 3000 LPH media Dual-sand and anthracite including suitable filter media complete all as specified and as directed by Engineer-in-Charge.
Supply only Activated carbon filter (ASF) 3000 LPH media Activated Carbon 900IV, Micron rating-10/5 Micron, including suitable filter media complete all as specified and as directed by Engineer-in-Charge.
Supply only Mild Steel coupling with rubber( spider type) L-276 suitable for 165 /125/100 Hp pump sets complete all as specified and as directed by Engineer-in-Charge.
Supply only rubber coupling( spider type) suitable for 165/100/30 Hp pump sets complete all as specified and as directed by Engineer-in-Charge.
M&L for in repair/replacement of flanged joint suitable for spigot and socket pipes and fittings of size 80 mm CI/DI specials, pipes complete all as specified and as directed by Engineer-in-Charge.
M&L for in repair/replacement flanged joint suitable for spigot and socket pipes and fittings of size 100 mm CI/DI specials, pipes complete all as specified and as directed by Engineer-in-Charge.
M&L for in repair/replacement flanged joint suitable for spigot and socket pipes and fittings of size 200 mm CI/DI specials, pipes complete all as specified and as directed by Engineer-in-Charge.
M&L for in repair/replacement with flanged joint suitable for spigot and socket pipes and fittings of size 250 mm CI/DI specials, pipes complete all as specified and as directed by Engineer-in-Charge.
M & L for replacement of ball bearings of reduction gear box of lime and alum dosing unit at Prothrapur filtration plant complete all as specified and as directed by Engineer-in-Charge. Make: SKF or as per site requirement as approved by GE
M & L for replacement of ball bearings of reduction gear box of flash mixture at Prothrapur filtration plant complete all as specified and as directed by Engineer-in-Charge. Make: SKF or as per site requirement as approved by GE
M & L for replacement of ball bearings of reduction gear box of clarifloculator bridge motor at Prothrapur filteration plant complete all as specified and as directed by Engineer-in-Charge. Make: SKF
M&L for taking out existing centrifugal pump of capacity 170/ 165 Hp for servicing ( as per manufacturer instructions) by disconnecting motor and pump set, pipe line and removing of all parts like bearing, bushes, impeller, shaft etc cleaning all rusted surfaces and scales formed inside/out side pumpset etc cleaning, oiling, greasing at proper places and re-fixing with oil paper packing in position, duly aligned with motor with all serviceable parts including painting with one coat of anti corrosive paint over red oxide primer and writing MES /SM No and testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Notes: i) Item requires replacement if found unserviceable then the same be replaced & measured and paid separately. ii) Spares will be measured and paid seperately.
All as per item No. 41 here in above but for capacity 125 /100 Hp complete all as specified and as directed by Engineer-in-Charge.
Supply only stainless steel shaft as per sample for pumpset of capacity 170/165 HP complete all as specified and as directed by Engineer-in-Charge.
Supply only stainless steel shaft as per sample for pumpset of capacity 125/100 HP complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement shaft sleeves of model No-UP150/45 with check nuts (Br) for 170/ 165 HP pump set complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement shaft shaft sleeves of with check nuts (Br) for 125/100 HP pump set Model DSM 125/40 complete all as specified and as directed by Engineer-in-Charge.
Supply only ball bearing for centrifugal pump of capacity 100/125/165/170 HP complete all as specified and as directed by Engineer-in-Charge.
Supply only 165HP/132KW pump impellor Gun metal model No. UP 150/45- 29 part , impellor part code No. 15900 complete all as specified and as directed by Engineer-in-Charge.
Supply only pressure gauge suitable for 125HP/100HP pump of pressure 0-150 Kg/Sq CM rating for suction pipe/ Discharge pipe complete with connected pipe and stop cock of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply only pressure gauge suitable for 165HP/170HP pump of pressure 0-250 Kg/Sq CM rating for suction pipe/ Discharge pipe complete with connected pipe and stop cock of suitable size complete all as specified and as directed by Engineer-in-Charge.
M&L Graphite gland packing, suitable for sluice valves or pump sets, fixed in position including taking down unserviceable gland packing as per site requirement etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for construction of block masonry valve pit of size 60 cm x 60 cm x 60 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded agrregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally upto 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, emebedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of dituminious paint over a coat of red oxide primer on steel surfaces and necessary earth work in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
All as per item No.52.00 here in but of size 90 cm x 90 cm x 90 cm complete all as specified and as directed by Engineer-in-Charge.
All as per item No.52.00 here in but of size 75 cm x 75 cm x 75 cm complete all as specified and as directed by Engineer-in-Charge.
M& L spray painting with synthetic enamel paint on old painted surfaces of pumps,motors & other machineries including necessary preparation of surfaces for each job at Chouldari dam pump house, Porthrapur filteration plant, NTS Pump house including using white paint for letter writing of existing SM/MES No complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs safety instruction/pump motor details display notice board for water supply installation made out of acrylic board in rectangle shape with heavy duty aluminium frame of size 0.5mtr x.75 mtr with details of pump/motor using letters as given and directed by Engineer-in-Charge and screwing the same on the wall properly complete all as specified and as directed by Engineer-in-Charge.
M&L in repair of chemical dosing pump reciprocating mechanicaly actuated diaphragm type for dosing of liquid products 0.5 HP 440 Volts AC 1440 RPM motor complete with 100 ltrs per hour capacity inluding indicator and agitaor (1280 rpm) complete all as specified and as directed by Engineer-in-Charge.
Taking up Unserviceable CI/DI Water Mains ( including fittings) with spigot and socket ends and lead joints from trench of any type/grade including burning out of joints and recovering lead complete all as specified and as directed by Engineer-in-Charge of the following sizes :-
80mm bore
150mm bore
200mm bore
250mm bore
350 mm bore
400 mm bore
M&L for CI/DI pipes with spigot and socket ends centrifugally cast class LA in any length, laid in trenches complete all as specified and as directed by Engineer-in-Charge of following sizes :-
80mm bore
150mm bore
200mm bore
250mm bore
350 mm bore
400 mm bore
M&L in replacement fabrication of 2.0mm thick Mild Steel sheet for valve chamber cover with plates of Fe 410W, Gde E-250, quality -A (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment for locking arrangements including painting with two coat of synthetic enamel paint black colour/shade over a coat of redoxide primer complete all as specified and as directed by Engineer-in-Charge
M&L for cleaning of service tanks installed on bldg roofs of multistoryed buildings at various places by emptying the tanks, by removing the scale, dirt and all other foreign materials depositing inside nipples on side of walls and bottom of the tanks by scrapping and brushing with wire brush, and pressure pump, cleaning with bleaching powder slurry and allowed to dry and then washing the tank with fresh water and writing on the tank the date of cleaning, capacity of tank etc shall be written on the out side of the tank with synthetic enamel paint with letter size 10 cm high and 6cm width in white colour, over a black background of size complete all as specified and as directed by Engineer-in-Charge for the following sizes:- Note:- (i) Maint register signed by users shall be submitted during the time of payment of RAR/FB duly signed by Engineer-in-Charge and Contractor. (ii) Any air lock/blockage complaints shall be attended by the contractor during the cleaning process with out any extra cost. (iii) PVC Tank covers and Float valve shall be fitted properly after completion of cleaning.
Tank capacity exceeding 250 litre but not exceeding 500 litre at Chouldari residential area, Chouldari dam area, Prothrapur filteration plant etc complete all as specified and as directed by Engineer-in-Charge
Tank capacity exc 750 ltrs and not exc 1000 ltrs Chouldari residential area, Chouldari dam area, Prothrapur filteration plant etc complete all as specified and as directed by Engineer-in-Charge
Tank capacity exc 1000 ltrs and not exc 2000 ltrs Chouldari residential area, Chouldari dam area, Prothrapur filteration plant etc complete all as specified and as directed by Engineer-in-Charge
Tank capacity exc 2000 ltrs and not exc 5000 ltrs Chouldari residential area, Chouldari dam area, Prothrapur filteration plant etc complete all as specified and as directed by Engineer-in-Charge
Tank capacity 2000 Gallon Liter Prothrapur filteration plant complete all as specified and as directed by Engineer-in-Charge
S&F in replacement of PVC Rotational moulded polyetheylene water storage tanks ISI marked double layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-II complete all as specified and as directed by Engineer-in-Charge of following Capacity:-
500 ltr capacity
750 ltr capacity
1000 ltr capacity
1500 ltr capacity
2000 ltr capacity
5000 ltr capacity
S&F in replacement PVC tank cover suitable for PVC service over head tank including necessary fixing arrangements of following capacity complete all as specified and as directed by Engineer-in-Charge
500/750 /1000 ltr capacity
1500/2000 ltr capacity
5000 ltr capacity
M&L for cleaning of RCC overhead reservoirs/semi under ground sump / Static tanks/ suction gallery using state of the art technology for the following capacity situated at various places under AGE E/M-II Minniebay by emptying the reservoirs, taking down the scale/sludge/mud/algae formed including and other foreign materials got deposited on side of walls and bottem of the tanks by scrapping and brushing with wire brush,cleaning with pressure pump,washing with bleaching powder slurry and allowing to dry and then washing and cleaning the tank with fresh water including applying one coat of white wash on internal surface of reservoirs / sumps and written details on tanks like date of cleaning ,capacity of tanks etc on the out side of the tank with synthetic enamel paint with letter size 20 cm high,10cm width in white colour,over a black backgroung of size 100 x 60 cm,all under ground and semi under ground sumps outer surface shall be painted with syntetic enamel paint of colour as all as specified and directed by Engineer-in-Charge for the following sizes:- Note: (i) Photograph before and after cleaning shall be submitted during the timing of payment for record. (i) Maint register signed by users shall be submitted during the time of payment of RAR/FB duly signed by Engineer-in-Charge and Contractor.
Over Head reservoir of capacity 6600 gallons on 10 to 12m staging at NTS
Fire Static tanks of capacity 1,00,000 ltrs at NTS
Semi underground sump of capacity 100000 gallons at Chouldari Dam Filtaration plant
Semi underground sump of capacity 150000 gallons at Porthrapur Filtration plant
Over Head reservoir of capacity 6600 gallons at Chouldari Dam residential area.
M&L for dismantling of Mild Steel base plate of the pumping set with foundation bolt of pump and motor capacity 100 HP to 170 HP including demolition of existing Plain Cement Concrete foundation/base/pedestal etc for requisite repair / replacement here-in-after complete
M&L for fabrication of MS channel base of existing size and grade made out of Steel channel MC75,MC100 &MC125 (As per existing dimensions) for pump and motor capacity 170 HP / 165 HP / 125 HP / 100 HP as mentioned against item No.67 here-in-before including necessary cutting, welding, grinding etc., and fixing the same on newly provided PCC foundation, foundation bolt etc., as per manufacturer recommendations to ensure proper alignment of both pump and motor complete, carry out painting the complete base plate with two coats of synthetic enamel paint Black shade / colour over a coat of Red oxide primer complete all as specified and as directed by Engineer-in-Charge
M&L for Painting to GI / CI water pipe line including Sluice Valves,valve chambers, NRV etc with two coat of synthetic enamel paint of black colour/shade or approved colour duly preparing the existing painted surfaces to the entire satisfaction of Engineer in charge of following dia of pipes :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
250 mm Dia
300 mm Dia
350 mm Dia
400 mm Dia
Supply and in replacement with existing Air release valve by remvoing the valve and repairing the same by replacing gaskes,nut,bolts, top and ball refixing the same, cast iron body, on both sides of the flanges, bolts and nuts complete all as specified and as directed by Engineer-in-Charge complete of following sizes :-
80 mm Dia bore
100 mm Dia bore
M&L for Schematic diagram in replacement for water supply distribution,Details for pump motor at Minnie bay pump hosue and swimming pool duly framed with lamination sheet cover appropriate size complete all as specified and as directed by Engineer-in-Charge
M&L for testing of water samples and obtain the test result for the perametrs as per IS 10500 like TDS,Colour,odour,TSS,PH,coliform turbidity,etc by carrying physical,chemical,microbiology examiniation from any govt authorised /NABL approved laboratary and source/location of water samples complete all as specified and as directed by Engineer-in-Charge
Excavation of trenches in soft / loose sail, n.exc 1.5m wide and n.exc 1.5m in depth: for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sq.m on plan and in.exc 1.5m in depth and getting out complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches in soft / loose sail, additional 1.5m wide and part thereof in depth beyond the first1.5m in depth for foundation,laying of pipe line complete all as specified and as directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms in any type of soil complete all as specified and as directed by Engineer-in-Charge
Removing excavated matrial to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point in any type of soil complete all as specified and as directed by Engineer-in-Charge
Supply only OT solution in 500 ml capacity bottles complete all as specified and as directed by the Eng-in-charge.
Supply only pH test solution in 500 ml capacity bottles complete all as specified and as directed by the Eng-in-charge.
Supply only Iron test solution in 500 ml capacity bottles complete all as specified and as directed by the Eng-in-charge.
Supply only CHLORINE TEST KIT with coloured sample & test-tubes complete with all testing fitments and OT solution in rexene finish box complete all as specified and as direction by Engineer-in-Charge.
Supply in replacement of PH test kit with coloured sample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) & test-tubes with necessary fitments and 100 ml testing solution in rexene finish wooden box complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement of Iron Test Kit & test-tubes with necessary fitments and testing solution in rexene finish box complete all as specified and as directed by Engineer-in-Charge.
Supply in replacement of mild steel heavy duty electronic weighing machine platform size 600 mm x 600 mm capacity 200 kg accuracy 5gm to 10 gm for prothrapur filteration plant .
Supply in replacement of mild steel heavy duty electronic weighing machine platform size 300 mm x 300 mm capacity 50 kg accuracy 5gm to 10 gm for NTS Pump house.
Dismantling and taking out the existing mono block / centrifugal/ Submersible type pump set, by disconnecting suction and delivery pipe lines of pump set , separate the motor from the pump, removing the burnt out winding from the slot cleaning the stator and rotor with CTC and smooth sand paper and rewinding the motor with suitable gauge of size with super enameled copper conductor and insulating by using class 'B' insulation keeping for drying, connecting electric connection, testing and commissioning to its satisfactory of Engineer-in-Charge complete all as directed for the following capacity :-
15/20HP pump set
100/125 HP pump set
165/170HP pump set
S & F LED Multifunctional meter with CTs Complete all as specified and directed
S & F Indication Lamp (LED type) Set of 3 Complete all as specified and directed by Engr in-Charge.
S&F in repair MCCB 3 Pole, 415 V, fixed type, 63 to 100 Amps with breaking capacity 16 KA. complete all as directed
S&F in repair MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA. complete all as directed
S&F in repair MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA.Adjustable type. complete all as directed
S&F in repair MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA. Adjustable type. complete all as directed.
S&F in repair MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 36 KA.Adjustable type. complete all as directed.
Supply and replacement of DOL starter for pump sets of capacity 7.5 HP AC, 415V 50 Hz 3 phase, relay range 13-22 Amps. complete all as directed.
Supply and replacement of Star delta starter for pump sets of capacity 10 HP to 20 HP AC, 415V, 50 Hz 3 phase complete all as directed.
S&F in repairs, fully automatic star delta motor starter with enclosure type ML-6 FASD or equivalent, 415 volt, 3 phase, relay range 66-110 A suitable for 100/125 HP motor, complete all as specified and as directed.
S&F in repairs, thermal relay, MN5 with timer suitable for 125 HP Pump starter fixed into ML-4 FASD, 415 volt, 3 phase , complete all as specified and as directed.
S&F in repairs, contactor, ML-4 block with IS/IEC 60647-4-1, IEC 60947-4-1, AC-1 100A, AC-3-70A, 415 V, 50HZ suitable for ML-4 FASD strater, complete all as specified and as directed.
S&F in repairs, ML-3 contactor block with IS/IEC-60947-4-1 & 45A AC 140 A AC3 415 Volt complete all as specified and as directed.
Taking up unserviceable LT UG cables from trench/poles/wall etc of sizes as mentioned here-in-after
6 Sqmm 2 core
10 Sqmm 2 core
16 Sqmm 2 core
Supply and laying underground PVC cable XLPE insulated armoured and PVC sheathed LT 1100 volts grade with aluminium conductor stranded of following sizes including suitable gland, crimping of lugs complete all as specified and directed :-
6 Sqmm 2 core
10 Sqmm 2 core
16 Sqmm 2 core
Supply, laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified.
M&L for re-winding and overhauling of unserviceable/burnt submersible pump set of capacity 5HP/7.5HP/10HP/20HP, removing all burnt out coils, cleaning the slots and rewinding the same with supper enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running of the capacity 5HP/7.5HP/10HP/20HP complete in all respects to the entire satisfaction of Engineer-in-Charge
Supply and laying in replacement submersible flat cable PVC insulated and screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) LT UG cable with stranded copper conductor for 1100 volts grade of 10 sqmm 3 core in trenches or passing through pipe complete in all respects to the entire satisfaction of Engineer-in-Charge.
Supply and fixing in replacement of 200mm bore Mild Steel ERW pipe heavy duty 3m length with reducer for suitable size/ as site requirement, 2 Nos of flange heavy duty both side including bend / reducer for suitable size welding with flange heavy duty, cutting/welding with smooth finish including nut bolts, washer and gasket for suitable size including applying two coats of synthetic enamel paint over a coat of metal primer testing complete all suction / delivery pipes complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Header of size 300mm bore Mild Steel ERW pipe heavy duty 5m length with reducer for suitable size/ as site requirement, 2 Nos of flange heavy connecting Y Joint (Motor delivery to header) and header pipe connect with Supply line duty both side cutting/welding with smooth finish including nut bolts, washer and gasket for suitable size including applying two coats of synthetic enamel paint over a coat of metal primer testing complete all suction / delivery pipes complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of reducer eccentric type 200 x 150 mm heavy duty, pressure rating 2A PN 16 bar, including nut bolts, washer and gaskete for suitable size complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth plate 25x4mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50 mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick with 10 mm dia reinforcement 100mm c/c and PCC chamber pit with PCC 1:2:4 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed.
S & F in replacement copper lugs upto 35 sqmm, for copper conductor suitable for all 30/40HP/50HP/60HP complete all as specified and directed by Engineer-in-Charge.
S & F in replacement copper lugs upto 70 sqmm, for copper conductor suitable for all 30/40HP/50HP/60HP complete all as specified and directed by Engineer-in-Charge.
S & F in replacement insulation mat in black colour, of existing make, model and of 8mm thickness of size not less than 1x 2 mtr for LT 440 volts confirming to relevent IS complete all as specified and directed by Engineer-in-Charge.
Supply, install, test in replacement bulk water flow meter of size 200/250mm, flanged type, helical enclosed, class B , wolt man type, mechanical driven, cast iron body, standards as per ISO 4064:2005, anti magnetic protection, high over load capacity, by cutting the existing CI/DI/MS pipe and inserting the water meter with necessary fittings and joints as required complete all as specified and directed by Engineer-in-Charge.
Material and labour in repair Design, Composition, Supply & Installation of 4 inch thick ACP Box of size 6 feet x 4 feet with MS pipe structure fix inside with 3 mm Acrylic sheet with digitally printed 3Mtr backlite Vinyl on HP Latex Printer, Display both side, LED modules complete upto 100 letters as specified size directed by Engineer-in-Charge with Andaman & Nicobar command and MES logo fixed with four nos of MS pipe Heavy duty 50 mm bore up to 3m height by nuts/bolts and welding as required at site , spray painting with two coat synthetic enamel paint complete MS pipe including necessary excavation and PCC work for foundation complete all as specified and direced by Engineer-in-Charge
Material and labour in repair Design, Composition, Supply & Installation of 4 inch thick ACP Box of size 12 feet x 4 feet with MS pipe structure fix inside with 3 mm Acrylic sheet with digitally printed 3m backlite Vinyl on HP Latex Printer, Display both side, LED modules complete upto 100 letters as specified size directed by Engineer-in-Charge with Andaman & Nicobar command and MES logo fixed with four nos of MS pipe Heavy duty 50 mm bore up to 6m height by nuts/bolts and welding as required at site , spray painting with two coat synthetic enamel paint comlete Mild Steel pipe including necessary excavation and PCC work for foundation complete all as specified and direced by Engineer-in-Charge
M&L in repair PVC coated GI chain link fencing 3.5 mm dia with 50 mm x 30 mm mesh including plates etc for supporting MS line wire rod flat iron & machine made hexagonal or square head bolts to fencing post including dismantling of existing fencing post complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair earth pit chamber board 3.15 mm thick mild steel sheet of size 45 cm x 45cm x 45 cm fixed with 12 mm thick mild steel rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters 6 cm height i.e. Earth Pit No, Location, Earthing test value and datecomplete all as specified and directed by Engineer-in-Charge.
M&L for mild steel work in joist, channel, angle or tee sections fixed indepently without connecting plates etc for supporting of tanks/chain link fencing etc as directed by Engineer-in-Charge including necessary welding grouting fixed making good to surface complete all as specified and directed by Engineer-in-Charge.
ANITA VARMA ENTERPRISES
T.M.RAMANATHAN AND SONS
MAJUMDAR FURNITURE
M/s Ramesh Lal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .