| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.0 LAdmitted-Finance WZ 66 SRI NAGAR RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | -55.11% | ₹11.0 L | L1 | Admitted-Finance |
| 2 | L2₹13.0 LAdmitted-Finance G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | -46.86% | ₹13.0 L | L2 | Admitted-Finance |
| 3 | L3₹15.0 LAdmitted-Finance | -38.88% | ₹15.0 L | L3 | Admitted-Finance |
| 4 | L4₹19.3 LAdmitted-Finance WZ 400 PALAM VILLAGE DELHI WEST DELHI SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | -21.21% | ₹19.3 L | L4 | Admitted-Finance |
Tender Value
₹24.5 L
EMD Value
₹48,994
Closing Date
12 Jan 2026, 3:00 pmClosed
EE(E)/ELD-5/DDA
ELD-5, CENTRAL NURSERY SECTOR 5 DWARKA NEW DELHI
Maintenance and operation of Lifts.......................sec-07 Ramphal chowk, and Staff quarter sec 06 Dwarka
2026_DDA_892548_1
26/EE/ELD-5/DDA-2025-26
Open Tender
Electrical Works
365 days
EE(E)/ELD-5/DDA
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹48,994
21 Jan 2026
5 Jan 2026
13 Jan 2026
5 Jan 2026
12 Jan 2026
5 Jan 2026
Maintenance and operation of IEI, Compound Light, D.G Set, Firefighting Pump set, fire alarm system, Clear water pump set, & lift at community hall sector-7 adjacent to palam village Sector 7 Ramphal Chowk Dwarka as per the inventory & terms and condition attached.
Maintenance and operation of IEI, Compound Light, Firefighting Pump set, Fire alarm system Clear water pump set, & lift at community hall HAF pkt.III Sector-09, Sector 6 Staff Quarter Dwarka as per the inventory & terms and condition attached.
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value(CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying and replacement of 1200 mm sweep size ceiling fan i/c connection, testing etc complete as reqd.
Supplying & replacement following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, testing etc. complete as required. i/c Rebate for dismantle material a) 250 A,36KA,FPMCCB (Ics=Icu)
b) 125 A,30KA,FPMCCB (Ics=Icu)
Supplying and Replacement of 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i/c Rebate for dismantle material a) SPMCB
b) DPMCB
LED Batten Light (System lumen efficancy >=105<=120 lm/Watt Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 18- 22 watt
Supplying and Replacement following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch
b) 3 pin 5/6 A socket outlet
c) 15/16 A switch
d) 6 pin 15/16 A socket outlet
Supplying and Replacement two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 1 x 1.5 sq. mm
b) 2 x 4 sq. mm
Servicing of 62.5 KVA D.G. set (Kirloskar make) i/c S/R of following parts/accessories, cartage testing on load etc complete as reqd. (Servicing of D.G. set has to be got done through authorised dealer of OEM) i) Oil filter --- 1 No. ii) Diesel filter (pre-micro)--- 1 set iii) Air cleaner elements --- 1 No. iv) K-cool superplus- 50-50 premix ---- 10 ltr. v) K-oil premix --- 13ltr, vi) Labour charges for servicing, functioning and testing--- 1 job vii) Radiator cleaning charges --- 1 job i/c removal & refixing
Supplying and Replacement of 300 mm sweep extra size metallic exhaust fan i/c connection, testing etc complete as reqd.
LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 90 Watt
Supplying of following size of XLPE insulated aluminium Conductor having stranded wire armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd. a) 2C x 16 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 63 mm dia (OD- 63 mm & ID-50 mm nominal)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Earthing with GI Earth Pipe 4.5 mtr long, 40 mm dia. including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.18 MB
NIT26PDF.pdf
Tender Documents • 1.87 MB
BOQ_938142.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid