Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-Finance | L1 | Accepted-Finance Qualfied | |
| 2 | L2₹14.8 L+₹1.2 L (9.02%)Accepted-Finance | L2 | Accepted-Finance Qualfied | |
| 3 | L3₹15.0 L+₹1.4 L (10.4%)Accepted-Finance | L3 | Accepted-Finance Qualfied | |
| 4 | L4₹15.2 L+₹1.6 L (11.7%)Accepted-Finance | L4 | Accepted-Finance Qualfied | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | NEHA ENTERPRISES L1 | M/S RAJ ASSOCIATES L3 | M/S YASHI ENTERPRISES L2 | C B S ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00Carriage of fallowings from ESC BSR to pit site on kachcha pakkaa road including loading and unloading chagres at both ends, required ccompletion of work, distance about to 0 to 70 Km. approx. | |||||||
| 2.00 | 11 KV Disc fitting | 168 | Nos. | 7 ₹1,176 Lowest | 20 ₹3,360 | 25 ₹4,200 | 30 ₹5,040 |
| 3.00 | 11 KV Disc Insulator T&C type 4500kg. | 168 | Nos. | 8 ₹1,344 Lowest | 20 ₹3,360 | 45 ₹7,560 | 30 ₹5,040 |
| 4.00 | 11 KV Pin insulator (Polymeric) | 93 | Nos. | 9 ₹837 Lowest | 30 ₹2,790 | 45 ₹4,185 | 40 ₹3,720 |
| 5.00 | Stay set Complete 16x1800 | 64 | Nos. | 35 ₹2,240 | 10 ₹640 Lowest | 100 ₹6,400 | 20 ₹1,280 |
| 6.00 | MS Channel 125x65x1300mm (T-off) | 34 | Nos. | 35 ₹1,190 | 20 ₹680 Lowest | 150 ₹5,100 | 30 ₹1,020 |
| 7.00 | MS Channel (Dropper) 100x50x2028mm (for fuse set) | 60 | Nos. | 60 ₹3,600 | 40 ₹2,400 Lowest | 150 ₹9,000 | 40 ₹2,400 Lowest |
| 8.00 | MS Top channel (125x65x2240mm) | 30 | Nos. | 60 ₹1,800 | 10 ₹300 Lowest | 150 ₹4,500 | 10 ₹300 Lowest |
| 9.00 | MS angle 75x75x6x2028mm with clamp & bolt and nut (T/F base) | 56 | Nos. | 130 ₹7,280 | 10 ₹560 Lowest | 120 ₹6,720 | 10 ₹560 Lowest |
| 10.00 | 11 KV fuse Set | 30 | Nos. | 150 ₹4,500 | 100 ₹3,000 Lowest | 1,000 ₹30,000 | 100 ₹3,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
16 Sept 2025, 11:00 amClosed
SE, EDC-III BULANDSHAHR
SE, EDC-III BULANDSHAHR
Work of construction of substations to remove overloading of distribution transformers at various 33/11 kV power substations in the Business Plan 2025-26 under Electricity Distribution Section- Jahangirabad.
2025_PVVNL_1070854_1
39/EDC-III/B/2025-2026
Open Tender
Electrical Works
Lump-sum
30 days
SE, EDC-III BULANDSHAHR
Work of construction of substations to remove overloading of distribution transformers at various 33/11 kV power substations in the Business Plan 2025-26 under Electricity Distribution Section- Jahangirabad.
2 documents required · 2 mandatory
₹1,180
SE, EDC-III BULANDSHAHR
₹15,000
27 Sept 2025
2 Sept 2025
16 Sept 2025
2 Sept 2025
16 Sept 2025
2 Sept 2025
Amount
Carriage of fallowings from ESC BSR to pit site on kachcha pakkaa road including loading and unloading chagres at both ends, required ccompletion of work, distance about to 0 to 70 Km. approx.
11 KV Disc fitting
11 KV Disc Insulator T&C type 4500kg.
11 KV Pin insulator (Polymeric)
Stay set Complete 16x1800
MS Channel 125x65x1300mm (T-off)
MS Channel (Dropper) 100x50x2028mm (for fuse set)
MS Top channel (125x65x2240mm)
MS angle 75x75x6x2028mm with clamp & bolt and nut (T/F base)
11 KV fuse Set
PCC Poles 8.5 Mtr. Long
11 KV TPMO
11/0.4 KV T/F 63 KVA
11/0.4 KV T/F 100 KVA
PCC Pole 11 MTr
11/0.4 KV T/F 250 KVA
LT PVC Cable Al 3.5x400 sq mm
LT XLP Cable al 1x400 sq. mm
LT ABC Cable (3x95+1x70+1x16) sq. mm
11 KV V-type Steel Cross Arm
Three Phase Distribution box
11/0.4 KV T/F 10 KVA
Earthing of pole by MS earthing rod of 20x2500mm & SWG earthing wire
LT incoming panel with metering equipment, Fuse & fixing arrangement (LS)
Weasel Conductor
The following meterial Erection & Fixing as per RESPO manual and as per direction fo Supervising Engineer. It includes the cost of labour, T&P, Carrier etc. required for proper completion of work.
11 KV Disc fitting
11 KV Disc Insulator T&C type 4500kg.
11 KV Pin insulator (Polymeric)
Stay set Complete 16x1800
MS Channel 125x65x1300mm (T-off)
MS Channel (Dropper) 100x50x2028mm (for fuse set)
MS Top channel (125x65x2240mm)
MS angle 75x75x6x2028mm with clamp & bolt and nut (T/F base)
11 KV fuse Set
PCC Poles 8.5 Mtr. Long
11 KV TPMO
11/0.4 KV T/F 63 KVA
11/0.4 KV T/F 100 KVA
PCC Pole 11 MTr
11/0.4 KV T/F 250 KVA
LT PVC Cable Al 3.5x400 sq mm
LT XLP Cable al 1x400 sq. mm
LT ABC Cable (3x95+1x70+1x16) sq. mm
11 KV V-type Steel Cross Arm
Three Phase Distribution box
11/0.4 KV T/F 10 KVA
Earthing of pole by MS earthing rod of 20x2500mm & SWG earthing wire
LT incoming panel with metering equipment, Fuse & fixing arrangement (LS)
Weasel Conductor
Providing & Fixing of the following material by the Contractor as per UPPCL/RESPO Rules.
Stone pad 300x300x75mm
LT PVC Cable 3.5x150/70 sq mm
Holding clamps for top channel TPMO & fuse set etc. with bolts & nuts
Clamps for LT T-off with bolts & Nuts
LT PVC Cable 3.5x70/35 sq mm
Concreting of poles
Danger baord Barbed wire including jumper
Copper L-piece 50x225x10mm (LS)
Copper L-piece 62x225x12 mm (LS)
Al Leg long barrel off size (LS)
4 core LT MCB with box (LS)
Plinth for size 2x2x1.5M
T/F 250 KVA earthing (Neutral & Body)
LT fuse set Protection Unit for 250 KVA DT with SMC Box
PRC Connector
Dead End Clamps
Sspension Clamps
Concreting Stay set
LT fuse set Protection Unit for 63 KVA DT with SMC Box
Cross Arm Holding Clamps with nuts&bolts
Three Phase Distribution box Clamps
Clamps for T/F(75x8mm)
LT fuse set Protection Unit for 100 KVA DT with SMC Box
Above work shall be done as per UPPCL/RESPO Rules.
M/S YASHI ENTERPRISES (BID ID -5537881)
M/S RAJ ASSOCIATES (BID ID -5537878)
C B S ENTERPRISES (BID ID -5537887)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .