Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC Responsive |
| 2 | L2₹3.6 Cr+₹14,822.06 (0.04%)Rejected-Finance Y 49 Y BLOCK HAUZ KHAS SOUTH WEST DELHI NEW DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | ₹3.6 Cr+₹14,822.06 (0.04%) | L2 | Rejected-Finance Not Responsive |
Tender Value
₹3 Cr
EMD Value
₹6 L
Closing Date
10 Dec 2020, 5:00 pmClosed
Executive Engineer
CCS HAU, Hisar
Construction of building of College of Agriculture (Phase-III i.e. library and examination hall) at Bawal. (including PH and EI works)
2020_HRY_151869_1
3178-C
Open Tender
Civil Works
Works
270 days
COA, Bawal
Please refer Tender documents.
6 documents required · 6 mandatory
₹15,000
₹6 L
27 Jan 2021
27 Nov 2020
14 Dec 2020
27 Nov 2020
10 Dec 2020
27 Nov 2020
Amount
Civil work 1 to 117:- Earth work excavation in ordinary soil exclusive of compensation of earth- {HSR 6.2 (b)} (b) Earth-work undressed with a combined lead upto 15 metres including breaking of clods
Dressing of earthwork :- (i) New work or remodelling work {HSR 6.3(i)}
Earth work in excavation in foundations, trenches, etc .in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches ,stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres (HSR 6.6)
(a) Earth filling under floors with surplus soil, excavated from foundation and taken only from outside the building plinth, in 15 cm layers, including ramming watering and consolidating lead upto 30 metres {HSR 6.13 (a)}
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 m and lift upto 1.5 m. (a) soft/loose soil {HSR 6.25 (a)}
Extra for smooth exposed concrete finish as desired which is not to be touched or plastered but is to be left as it comes out of the shuttering for columns (square or rectangular or polygonal in plan) {HSR 9.9(45% of labour rate)}
Extra for smooth exposed concrete finish as desired which is not to be touched or plastered but is to be left as it comes out of the shuttering for corbel, parapets, fascias and other similar items, including edges. {HSR 9.11(45% of labour rate)}
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth. (HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59 + Note) Second storey
Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work , placing and fixing in position, complete at the ground level or in first storey (HSR 10.77)
Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in tiles and channels and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete at the ground level or in first storey (HSR 10.78)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects (HSR 10.81)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects (HSR 10.81 + Note) Second storey
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects. (HSR 10.82)
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects. (HSR 10.82 + Note) Second storey
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects (HSR 10.82 + Note)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. (HSR 10.86)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects (HSR 10.86+ Note) Second storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by item nos. 10.82,10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centring and shuttering , laid in position, complete in all respects.(HSR 10.89)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects, (For work upto 1.5 metres below ground level) (HSR 10.90)
(a) Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 {HSR 10.95 (a)}
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with 2 coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded. (HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth (HSR 11.2)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7+ Note) Second storey
(a) 11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure {HSR 11.48(a)}
(a) 11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure (HSR 11.48 (a) + Note) Second storey
11.43 cm thick brick wall with every fourth course reinforced with hoop-iron laid in 1:4 cement stone dust (from crusher) mortar in superstructure. (HSR 11.51)
11.43 cm thick brick wall with every fourth course reinforced with hoop-iron laid in 1:4 cement stone dust (from crusher) mortar in superstructure. (HSR 11.51+ Note) Second storey
11.43 cm thick brick wall laid in cement stone dust (from crusher) mortar 1:4 without reinforcement in foundation and plinth. (HSR 11.52)
11.43 cm thick brick wall laid in cement stone dust (from crusher) mortar 1:4 in superstructure (HSR 11.53)
11.43 cm thick brick wall laid in cement stone dust (from crusher) mortar 1:4 in superstructure (HSR 11.53+ Note) Second storey
Providing 5.72 cm brick dalli facing with brick size 22.86 cm X 11.43 cm X 5.72 cm thick to be obtained after cutting of bricks laid in cement sand mortar 1:3 on RCC lintels, beams fascia etc. including centring and shuttering complete. (HSR 11.98)
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13 + Note) Second Storey
Providing and fixing cast iron rain water non pressure pipe, I.S.I. mark with ears with screw and wooden plugs fixed on wall face including filling joints with spun-yarn and cement mortar 1:2 excluding head and shoe, etc. {HSR 13.45 (b)} (b) 150mm dia pipe
Extra over rate of item nos. 13.45(b) in case lead joints are used instead of cement joints {HSR 13.46 (b)}
Providing and fixing C.I. plain bends in position with gutter, etc.{HSR 13.49 (b)} (b) 150 mm dia pipe
Top khurra 0.6 m X 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13..50)
Bottom khurra on ground 1.2 m X 0.6 m consisting of brick-on-edge laid in cement mortar 1:3 over 75 mm cement concrete 1:8:16 including 12 mm thick cement plaster 1:3 (HSR 13.57)
Cement concrete 1:2:4 gola 10 cm X 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64)
Providing and lying cinder concrete in cement 1:15 (1 cement and 15 cinder) on terraced roofs & ( Ist storey) , laid to slope , including consolidating the same (HSR 13.66)
Providing and fixing PVC rain water pipe 6 kg pressure of ISI mark in cement mortar during masonry work {HSR 13.89 (a)} (a) 100 MM dia PVC pipe 6 kg pressure
Providing and fixing PVC bend ISI mark {HSR 13.90(a)} (a) 100 MM dia PVC Bend
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvanized mild steel item (galvanized @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre to centre along main 'T'. The system should rest on periphery walls/partitions with the help of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling (HSR 14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4)
Conglomerate floor 40 mm thick in 2 coats, under layer 30 mm thick of cement concrete 1:2:4 and top layer 10 mm thick 1:1.5 cement grit ( 1 part of cement : 1.5 part of stone grit) Baed on (Based on HSR 14.9)
18 mm thick grey polished skirting or dado consisting of bottom layer of 15 mm thick cement sand plaster 1:3 and finished with 3 mm thick topping of neat cement rubbed and polished including rounding off junction with floors (HSR 14.18)
Precast terrazzo tiles of 20 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and over the base in floors, treads of steps and landings including rubbing and polishing {HSR 14.44 (a)} (a) In ordinary grey cement
Precast terrazzo tiles of 20 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and over the base in floors, treads of steps and landings including rubbing and polishing. {HSR 14.44 (a) +Note} (a) In ordinary grey cement Second storey
Precast chequered tiles of 20 mm thickness in ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and over the base in floors, treads of steps and landings. (HSR 14.45)
Precast terrazzo tiles of 12.5 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 10 mm thick cement coarse sand plaster 1:3 and jointed with neat cement slurry in skirting, dado and risers of steps, including rubbing and polishing complete. {HSR 14.47 (e)} (e) In grey cement mixed with black, red or chocolate pigment.
Kotah stone flooring, minimum 25 mm thick, in any pattern as specified over 20 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62) (Note: The floor shall be finished with granite polish and nothing shall be paid extra).
Kotah stone flooring, minimum 25 mm thick, in any pattern as specified over 20 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62 + Note) (Note: The floor shall be finished with granite polish and nothing shall be paid extra). Second storey
Kotah stone 20 mm thick in skirting risers of steps, dados pillars and wall facing(lining) in any pattern as specified 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66) (Note: The skirting shall be finished with granite polish and nothing shall be paid extra).
Kotah stone 20 mm thick in skirting risers of steps, dados pillars and wall facing(lining) in any pattern as specified 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66 + Note) (Note: The skirting shall be finished with granite polish and nothing shall be paid extra). Second storey
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in flooring laid in any patterns as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles (HSR 14.89) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS & RAK ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in skirting / dado laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles (HSR 14.90) Note : Tile shall be of premium quality (first quality of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS & RAK ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this
Providing and fixing ceramic tiles/ anti skid tiles of size 400 mm x 400 mm or above size of approved make in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. (HSR 14.91) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSONS & RAK ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manufacturer) of approved make in all colour, shades except burgundy, bottle green, black of any size of approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement coarse sand mortar 1:3 and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete. {HSR 14.92 (b)} (b) Size of ceramic glazed tiles 300 mm x 450 mm
Providing edge moulding to 17-20 m thick granite stone counters, vanities etc. including machine polished to edge to give high finish etc. complete as per design apprvoed by Engineer-In-Charge (Moulding) {HSR 14.98 (i)} (i) Single moulding
12 mm thick cement plaster 1:4 on walls (HSR 15.5 + Note) Third storey
12 mm thick cement plaster 1:6 on walls (HSR 15.7)
12 mm thick cement plaster 1:6 on walls (HSR 15.7 note) Second storey
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12)
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12 + Note) Second storey
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52)
10 mm thick cement plaster 1:4 on underside of ceiling (HSR 15.52 + Note) Second storey
Cement pointing 1:2 flush on flat brick flooring (HSR 15.71 + Note) Second storey
Cement pointing on stone slab pavement with cement mortar 1:2 (HSR 15.73)
12 mm thick cement coarse sand plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :- {HSR 15.76) (a)} (a) Vertical (+) extra cost of coarse sand
12 mm thick cement coarse sand plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :- {HSR 15.76 (b)} (b) Horizental (+) extra cost of coarse sand
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :- (HSR 15.77 (a) Vertical
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :-{HSR 15.77 (b)} (b) Horizental
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded :-{HSR 15.77 (b) + Note} (b) Horizental Second storey
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead , linseed oil, varnish and chalk mitti including finishing the surface to required finish complete (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping, etc. (HSR 16.2)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.3)
Applying priming coat with metal primer on new steel or iron work including preparation of surface (HSR 16.9)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Providing two coats of exterior acrylic emulsion paint . {HSR 16.79 (b)} (b) 1st quality
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Commercial hard wood such as hollock, champ, chikrassy and chaplash ,etc.,(non coniferous timber other than teak conforming to I.S. specification No. 1003 kiln seasoned), shutters with vertical styles and rails, as specified in the statement No.1 ( attached in the end of this chapter) , with two Nos. plywood panels of the specified thickness, mentioned below , tongued and grooved including the cost of iron hinges, screws, chocks/cleats, stops ,etc. ,complete fixed in position excluding the cost of tower bolts and handles but including the labour for fixing the same- (HSR 17.30 (a) + Note) a) 35 mm thick (12 mm thick BWR Grade-II ply wood panel) Note: Nothing shall be paid extra for additional vertical style (any size) if required by the Architect or by the Engineer-in-Charge)
Proving and fixing 35 mm thick glazed door and windows shutters of commercial hard wood such as hollock, champ, chikrassy and chaplash, etc. ( non-coniferous timber other than teak confirming to I.S. specifications No. 1003 kiln seasoned), with vertical styles and rails, as specified in the statement no.1 ( attached in the end of this chapter), with glass panes of 4 mm thickness , tongued and grooved including the cost of iron hinges , screws, chocks/cleats, stops , etc., complete fixed in position excluding the cost of tower bolt and handles but including the labour for fixing the same. (Based on HSR 17.30 (a) + 17.24 (c ) (a) 35 mm thick ( 4 mm thick glass panes)
Supplying and fixing hydraulic door closer, I.S.I. mark, with necessary screws , etc., complete- {HSR 17.82 (c )} (c) I.S.I. designation No. III ( size of door 851 mm to 1000 mm)
Providing and fixing sliding bolt with nuts and screws, etc., complete. {HSR 17.83 (b) (ii)} (b) Aluminium (ii) size 250 mm X 16 mm
Providing and fixing 0.50 mm thick aluminium sheet, including cost of necessary screws, etc., complete (HSR 17.87)
Factory manufactured solid flush door shutters, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops, etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- {HSR 17.93 (a) (iii)} (a) commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminated core and lipped edges (iii) 35mm thick
Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS;733 and IS; 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete (HSR 17.95 + Note (I) Fixed portion (Powered Coated Aluminium sections dyed to required shade according to IS;1868, minimum powder coating 50 micron)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS; 733 and IS;1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including clear angle, aluminium snap beading for glazing/ paneling C.P. brass/ stainless steel screws, etc. complete. (HSR 17.96 + Note (I) Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including of cost of PVC/ neoprene gasket required including Aluminium fitting. Aluminium sections/ beading shall have powder coating of 50 micron both side
Providing and fixing 12 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS;12823 grade I type II in paneling fixed in aluminium doors. Windows shutters and partition frames with CP brass/ stainless steel screws etc. complete {HSR 17.97 (b)} (b) Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, windows, ventilator shutter and partitions etc. with PVC/ neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items). {HSR 17.98(b)} (b) With float glass panes of 5.0 mm thickness.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS; 6315 marked for doors including cost of cutting floors as required embedding in floors and cover plats with brass pivot and single piece M.S. sheet outer box. (HSR 17.99} (a) With Stainless Steel cover plate.
Providing fixing aluminium round shape handle of outer dia 100 mm with screws etc. complete. {HSR 17.102(i)} (i) Anodized (AC-15) Aluminium.
Wrought iron and mild steel (using angles, flats square bars. tees and channels) ladders, grills, gratting frames, window guards, iron door openable or fixed stair case or parapet or any other type of railing , gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Supplying and fixing glass panes including special metal sash putty of approved make {HSR 18.30 (b)} (b) Glass panes 4 mm thick, exceeding 40 sq dm areas
Pressed steel sheet frames (chowkhats), consisting of 2.00 mm thick steel sheet of the specified section, including iron lugs (hold fasts, iron hinges, confirming to PWD specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red led non-setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs, complete:-{HSR 18.34 (a)} (a) Door and window frame of size 89 mm x 50 mm with 40 mm wide single rebate.
Pressed steel sheet frames (chowkhats), consisting of 2.00 mm thick steel sheet of the specified section, including iron lugs (hold fasts, iron hinges, confirming to PWD specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red led non-setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs, complete:-{HSR 18.34 (b)} (b) Door and window frame of size 76mmx 38mm with 35mm wide single rebate.
Providing and fixing 15 mm to 18 mm thick Z-Black granite stone (polished) on work top including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing 15 mm to 18 mm thick Sardarali granite stone (polished) in flooring including matching grains laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing 15 mm to 18 mm thick Sardarali granite stone (polished) in skirting/dado including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete.(NS)
Providing and fixing C.I. grating over 100 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Providing and fixing C.I. grating over 150 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Providing and fixing 45 mm wide solid and 30 mm wide jali Zebra type (PCL rainbow or any other equivalent make as approved by Engineer In charge) horizontal venetian blinds of required size and shape, fixed in position including rawl plugs and screws etc. complete in all respect (NS)
Earth filling under floors with dune sand (tibba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete. (NS)
Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continous chemical barrier under and all round the column pits, wall trenches, basement excavation, top surface of plinth filling junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits etc., complete as per PWD specifications (plinth area of the building at ground floor only shall be measured of payment (NS) (the material i.e. Chlorphriphos Emulsifiable concentrate 20% with 1% conentration shall be arranged by the contractor)
Providing and fixing 12 mm thick toughened glass ( Saint Gobin make) for door shutter including making holes for fixing accessories such as handles, L-connectors and cut out for floor machine etc., complete in all respect as directed by the Engineer In Charge. (excluding cost of handles, connectors and floor machine). (NS)
Providing and fixing 12 mm thick toughened glass ( Saint Gobin make) as fixed panels in powder coated aluminium sections & beadings for glazing, fixed in position, complete in all respect as directed by the Engineer In Charge, but excluding element of aluminium sections and beadings which shall paid separately under HSR item. (NS)
Providing and fixing Glass Accessories i.e. handle of size 600 mmx 30 mm of DORMA make (model XL-C 3004) including cost of stainless steel screws etc., complete in all respect as directed by the Engineer In Charge. (NS)
Providing and fixing Glass Accessories i.e. Glass Door package with lock (Floor machine) of DORMA make (model XL-C 4001) including cost of stainless steel screws etc., complete in all respect as directed by the Engineer In Charge. (NS)
Providing and fixing frosted film of approved make shade and colour, fixed in position on toughened glass including making design/ pattern as per architectural drawing and design complete in all respect. (NS)
Providing and fixing 3’-0” high staircase railing of stainless steel of 304 grade of approved make consisting of the followings:- i. Main pillar of 100 mm dia. stainless steel pipe of 16 gauge with 6” dia. stainless steel cup of round shape at top. ii. Hand rail of 50 mm dia. stainless steel pipe of 18 gauge. iii. Balusters 2’-6” high of 40 mm dia. stainless steel pipe of 18 gauge with 3” dia. stainless steel cup of round shape at top. iv. Intermediate 3 Nos. 19 mm dia. stainless steel pipes of 18 gauge fixed horizontally throughout the length. Including holders, Mild steel plate of round shape for fixing balusters, stainless steel balls, rawl plugs and other petty items, fixed in position, complete in all respect as per drawing and design. (NS)
PH work 118 to 202:- Excavation for pipe lines running under pressure in trenches and pits, in streets & lanes including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, cutting trees and bushes, etc., refilling consolidation and watering of refill. In 15 cm layers and restoration of unmetalled or unpaved surface to its original condition, including the cost of dewatering of rain water, diversion of traffic, night signals, fixing caution boards, crossing over trenches for access to the houses, watching fencing, etc., and disposal of surplus soil outside and inside the town, involving lead up to one K.M. in ordinary soil:-(HSR 6.9(a)} (a) without tembering and shorting upto 1.5 metres depth
Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawing including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimension, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc., night signals, profiles, pegs, sight rails, boning rods, crossing over trenches, for access to the houses, watching, fencing, etc., fixing and maintenance of caution boards, refilling of trenches, watering of refill, in 15 cm layers, ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, up to a lead of 1 K.M. in ordinary soil {HSR 6.10(a)} (a) for depth of excavation not exceeding 3 metres below ground level
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth.(HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41)
Cement conc. 1:2:4 with stone aggregate 20 mm nominal size for reinforced conc. Work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respects. (HSR 10.82)
Extra over item Nos.10.79 to 10.94, if 1:1½:3 mix is used instead of 1:2:4. {HSR 10.95(a)}
First class brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.(HSR 11.8)
12 mm thick cement plaster 1:5 (HSR 15.6)
Steel work, fixed independently without connecting plates, including cutting hoisting and fixing in position in:- {HSR 18.1 (a)} (a) R.S. Joist
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. {HSR 28.18(b) (i)} INCLUDING COST OF SPECIALS (i) 15 mm internal diameter of pipe line
(ii) 20 mm internal diameter of pipe line {HSR 28.18(b) (ii)}
(iii) 25 mm internal diameter of pipe line {HSR 28.18(b) (iii)}
(v) 40 mm internal diameter of pipe line {HSR 28.18(b) (v)}
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. (HSR 28.21 (a) (a) 15 mm internal diameter
(b) 20 mm dia (HSR 28.21 (b)
(c) 25 mm dia (HSR 28.21 (c)
(e) 40 mm dia (HSR 28.21 (e)
Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections:- {HSR 28.22(c)} (c) 20 mm internal diameter
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 28.24 (a) (a) 11.43 cm thickness wall
(b) 22.86 cm thickness wall (HSR 28.24 (b)
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including repointing, replastering, replacing bitumen and colour or white washing where required. {HSR 28.26(b)} (b) 115 mm thickness of roof of floor
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. {HSR 28.29 (b)} (b) 20 mm internal diameter
(c) 25 mm internal diameter {HSR 28.29 (c)}
(e) 40 mm internal diameter {HSR 28.29 (e)}
Constructing brick masonry inspection chambers sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/C.C. topping. 50 mm thick with 455 mm x 455 mm/ 455 mm x 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 29.84 (b) (b) size 450 mm x 600 mm inside ( with 455 mm x 610 mm cover and frame single seal pattern 1 weighing 38 kg with C.C. topping)
(c) size 600 mm x 900 mm inside ( with 455 mm x 610 mm cover and frame single seal pattern 1 weighing 38 kg with C.C. topping) (HSR 29.84 (c)
Extra for over 0.30 meter depth of inspection chamber:- {HSR 29.85 (c)} (c) 600 mm x 900 mm
Providing slat glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with is: 651 and their lowering, cutting, jointing and testing as desired in HSR item No. 29.38, 29.39, 29.40, including the cost of jointing materials as well as carriage, loading, unlloding stacking, handing, re-handling etc. complete in all respects to the satisfaction of Engineer-In Charge. (HSR 29.95) 150 mm internal dia
Providing and fixing in position best Indian make (to the approval of the Engineer-in-charge). Indian type Orissa or orya water closet suite for sinking into floor, with raised foot treads complete with 100 mm H.C.I ‘P’ trap with or without vent as required and all other necessary fittings as fully described in item no. 30.1 above (without cost of C.I. high level flushing cisterns) (based on 30.2(a)(i)} (a) 580 mm (i) WHITE
Providing and fixing in position best Indian make European type water closet suite with concealed ‘P’ of ‘S’ trap with or without vent (as approved by the Engineer-in-Charge) and all other necessary fittings as fully described in item No. 30.3 above (without cost of C.I. high level flushing cisterns) {based on HSR 30.6(i)} (White)
Extra over item no. 30.3 to 30.6 for providing and fixing best Indian make plastic hygenic seat with lid complete instead of hollow black or white plastic seat and lid. {HSR 30.13 (i)} (i) White plastic seat ( Solid)
Extra for providing and fixing 32 mm dia. G.I/ C.P flush pipe complete with accessories instead of 32 mm dia. Galvanised telescopic flush pipe with clips ( as required by the Engineer-in-charge) {HSR 30.15(b)} (b) 32mm dia C.P brass flush pipe
Providing and fixing in position best Indian make a range of four uninals flat back or angular lipped front 610 mm high in vitreous chinaware with two Nos. 5 litres capacity best Indian make C.I automatic flushing cistern with fittings and flush pipe etc. complete as fully described in Item No. 30.25 above {HSR 30.28 (i)} Range of four Usrinals (i) White
Extra for providing and fixing vitreous automatic flushing Cistern including fittings and brackets of C.I. flushing cistern complete {HSR 30.37(b)(i)} 10 ltr. capacity cistern (i) White
Extra for providing and fixing standard size C.P. brass flush pipe complete with fittings instead of G.I flush pipe complete {HSR 30.38 (iv)} (iv) For a range of four urinals
Providing and fixing 25 mm thick marble partitions for different type of urinals. {HSR 30.40(b)(II)(i)} (b) Vitreous Chainaware Partition Plate (II) LARGE SIZE 835 mm x 355 mm (i) White
Providing and fixing in position best Indian make Lavatory suites (with full anti splash rim in vitreous chinaware and all other necessary fittings as fully described in item No.30.41 above. White {HSR 30.42(ii)} ii.) Size 530mm x 430mm with one No. tap
Providing and fixing in position 32 mm dia G.I waste pipe embedded in wall or lead waste pipe (weighing 3.47 kg per meter and 2.8 mm thick) up to floor level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge) (HSR 30.48)
Providing and fixing in position best Indian make chromium plated brass bottle trap 32 mm diameter {HSR 30.50}
Providing and fixing 40mm G.I waste pipe embedded in walls or lead waste pipe weighing 4.46 kg/ metre and 3.0 mm thick up to floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)
Providing and fixing in position best Indian make paper holders fixed into wall with C.P brass screws complete in all respects including cutting and making good the walls etc. {HSR 30.67(a)} (a) C.P. brass
Providing and fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on asbestos sheet ground fixed in position by means of 4 nos. chromium plated brass screws and washers over rubber washers and rawl plug embedded in the wall of chromium plated brass clamps with C.P brass screws ( as required by the Engineer-in-charge) complete including cutting and making good the walls etc. {HSR 30.71(a)(i)} (a) INDIAN MAKE (i) 600mmx450mm
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P brass screws and rawl plugs etc. complete including cutting and making good the walls etc. {HSR 30.73(a)(i)} (a) C.P. BRASS (i) One way
Providing and fixing in position 15 mm i/d C.P brass bib cocks of best quality ( as required by the Engineer-in-charge) {HSR 30.75(a)} (a) Bib cock lond body.
(c) Bib cock {HSR 30.75(c)}
Providing and fixing in position C.P brass stop cock (as approved by the Engineer-in-charge) {HSR 30.76(a)(ii)} (a) 15 MM STOP COCK (ii) concealed stop cock with flange
Providing and fixing C.P brass liquid soap container of best quality (as required by Engineering-In-Charge). (HSR 30.77)
Providing and fixing in position best Indian make C.P brass inlet connection 15mm with 375mm pipe and C.P brass nuts. {HSR 30.83}
Providing and fixing in position H.C.I soil waste vent or antisyphonage pipes to I.S.I specifications of E.L.C manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floors etc. and making good to its original condition but excluding cost of lead jointing. {HSR 30.84 (a )} (labour rate) (a) 100 mm internal diameter
(b) 75 mm internal diameter {HSR 30.84 ( b)} (labour rate)
Providing lead caulked joints to H.C.I pipes and specials conforming to I.S.I specification of E.L.C manufacture or any other reputed firm including cost of lead yarn, fuel and tools etc. {HSR 30.87(a)} (a) 100 mm internal diameter
(b) 75 mm internal diameter {HSR 30.87(b)}
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S flat not less than 5mm of the approved design for fixing C.I soil waste vent or anti pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting {HSR 30.88(a)} (a) for 100mm internal diameter pipes
(b) for 75mm internal diameter pipes {HSR 30.88(b)}
Providing and fixing H.C.I. floor traps I.S.I. marked of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under the around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc., minimum depth of water should be 150 mm with a minimum seal of 50 mm {HSR 30.89(b)} (b) With 75 mm internal dia outlet
Providing and fixing in position H.C.I specials for soil, waste, vent or anti-syphonage pipes to I.S.I marked including cutting and wastage etc/., and making good to its original condition but excluding cost of lead jointing. {HSR 30.91 (a)(i)} (a) For 100 Mm I/D Pipes (i) heal rest bend
(ii) Double junction with door 100 mm x 100 mm x 100 mm x100 mm {HSR 30.91(a)(ii)}
(xiii) Bend with door {HSR30.91(a)(xiii)}
(xiv) Bend plain {HSR30.91(a)(xiv)}
(xvi) Cowls {HSR30.91(a)(xvi)}
(xxii) Collars {HSR30.91(a)(xxii)}
(b) For 75 Mm I/D Pipes (i) heal rest bend {HSR30.91(b)(i)}
(xiii) Bend with door {HSR30.91(b)(xiii)}
xvii) Cowls {HSR30.91(b)(xvii)}
(xviii) Collars {HSR30.91(b)(xviii)}
Cutting chase in brick walls in cement or in floor for embedding G.I. or H.C.I. pipe lines and making good the same to its original condition {HSR 30.95(a) (a)size 75 mm X 75 mm
Providing and fixing in position automatic brass ball valves in tanks. {HSR 30.110 (b) (iii)} (b) With plastic ball (iii) 25 mm internal diameter
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm X 150 mm cast iron cover weighing approximately 7.26 kg. and frame clear opening 300 mm X 300 mm and outside size 330 mm X 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:8:16 in foundations, and cement concrete 1:2:4 in coping around C.I. cover and frame et. With three coats of black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm {HSR 30.114(b)} (b) 100 mm internal diameter H.C.I. gully trap
Providing and fixing HDPE WATER STORAGE TANKS of sintex, diplas O.K. Supreme make with covers/ lids marked with IS: 12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow & scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction of Engineer-in- Charge. (HSR 30.119) 2000 Ltr. Capacity
Supply of GI pipe 'B' Class ISI Marked Ravindra/Jindal/Parkash(Surya) Make. (NS) (a)15 mm i/d
(b)20 mm i/d
(c ) 25 mm i/d
(d) 40 mm i/d
Supply of GI Union Couplings of UNIK/UNCO make . (NS) (a)15 mm i/d
(b) 20 mm i/d
(c) 25 mm i/d
(d) 40 mm i/d
Supply of Gun Metal Peet Valve ISI Marked of DRP/Leader/Bajaj make (NS) (a) 20 mm i/d
(b) 25 mm i/d
(c) 40 mm i/d
Providing and fixing in position PVC flushing cistern 8.0 ltrs. capacity of Hindware/Cera/perryware make ISI marked, white, alongwith fittings complete in all respect. (NS)
Supply and fixing in position stainless steel sink made of 1 mm thick Salem stainless steel sheet along with fittings of Blue Star/ Jayna make or equivalent as per AISI 304 (18/8), complete in all respect. (NS) Bowl size = 560 mm x 405 mm x 178 mm Overall size = 610 mm x 460 mm x 178 mm
Providing and installation of self contained drinking water cooler of fully stainless steel body (FSS) with refrigerant R-134 A, cooling capacity 120 liters per hour and storage capacity 120 liter suitable on operating power supply 230 ± 10 %, 50-Hz single face AC complete in all respect. Make = Usha/Voltas/Blue star as approved by the Engineer Incharge (N.S.)
Providing and fixing in position R.O./water purifier (to be fixed with water cooler) with 7 liter storage capacity and 15 liter per hour purification capacity complete in all respect to the satisfaction and direction of the Engineer Incharge. Make- Kent/Acquaguard (N.S).
Electrical ( including AC & fire fighting) item No. 203 to 364:- (c ) Moulded case circuit breakers:- S/E of moulded case circuit breaker on wall or on existing pedestal including bonding to earth and necessary connections:- {HSR 31.12 (c ) (i)} (i) 15 amp. 60 amp. 415
(ii) 100 amp. To 220 amp. {HSR 31.12 (c ) (ii)}
(iv) 300 amp. To 400 amp. {HSR 31.12 (c ) (iv)}
S/E of miniature circuit breaker/isolator 240/415 V in the existing distribuiton board including making necessary connections:-{ HSR 31.17 (ii)} (ii) SP MCB 6 amp. To 32 amp.
(iii) SPN MCB 40 to 63 amp.
S/E of Fittings and Accessories:- (xxvi) S/E of hexagonal M.S. box 1.60 mm thick having each side 8 cms, 7.5 cms deep, top covered with M.S. lid by means of screws including 10 mm dia 30 mm long mild steel rod made into suitable suspension hook and erected in R.C.C. slab for ecrection of fan, the bottom covered with 3 mm thick bakelite sheet with suitable holes, painting etc. complete with all labour and material required to complete the job. {HSR 31.18 (xxvi)}
Pipe Laying:- S/E of pipe for wiring purpose including bends inspection boxes etc. where necessary and painting as required:- {HSR 31.21 (xv)} (xv) Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on surface.
(xvi) Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness on surface. {HSR 31.21 (xvi)}
(xvii) Heavy gauge welded conduit pipe 32 mm dia 1.60 mm thickness on surface. {HSR 31.21 (xvii)}
(xxi) Heavy gauge welded conduit pipe 20 mm dia 2.00 mm thickness flushed. {HSR 31.21 (xxi)}
(xxii) Heavy gauge welded conduit pipe 25 mm dia 2.00 mm thickness flushed. {HSR 31.21 (xxii)}
(xxiii) Heavy gauge welded conduit pipe 32 mm dia 1.60 mm thickness flushed. {HSR 31.21 (xxiii)}
(xxx) Supply and erection of PVC pipe of 6 kg. Pressure, laid 1 metre below ground level complete, including digging refilling of the trench with jointing etc:- {HSR 31.21 (xxx) (b)} (b) PVC pipe 80 mm dia
Earthing:- (i) Earthing with G.I earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required. {HSR 31.22 (i)}
(ii) Extra for using salt and char coal/coke for pipe earth electrode as required. {HSR 31.22 (ii)}
(iii) Earthing with G.I. earth plate 600 mm x 600 mm x 600 mm x 6 mm thick including accessories and providing enclosures accessories and providing enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. {HSR 31.22 (iii)}
(iv) Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. {HSR 31.22 (iv)}
(v) Extra for charcoal or coke and salt for G.I plate or copper plate earth electrode. {HSR 31.22 (v)}
(x) Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. {HSR 31.22 (x)}
(xi) Supplying and laying 25 mm x 5 mm GI strip in 40 mm dia G.I pipe from earth electrode as required. {HSR 31.22 (xi)}
(xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I wire in 15 mm dia G.I. pipe from earth electrode as required. {HSR 31.22 (xii)}
(xiv) Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required with all labour and material. {HSR 31.22 (xiv)}
(xv) Pdg. and fixing 25 mm x 5 mm G.I strip on surface or in recess for connection etc. as required with all labour and material. {HSR 31.22 (xv)}
(xvi) Pdg. and fixing 4.00 mm dia G.I. wire on surface or in recess for loop earthing as required. {HSR 31.22 (xvi)}
S/E of under gground cable 1 metre below ground level covered with sand and bricks including necessary connections digging and refilling of trenches:- {HSR 31.25 (xxx)} (xxx) 120 sq mm 3 ½ Core cable (Armoured)
(xxxii) 185 sq mm 3 ½ Core cable (Armoured) {HSR 31.25 (xxxii)}
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections:-{HSR 31.26 (v)} (v) 16 sq mm 2 Core cable (Armoured)
(xxx) 120 sq mm 3 ½ Core cable (Armoured) {HSR 31.26 (xxx)}
(xxxii) 185 sq mm 3 ½ Core cable (Armoured) {HSR 31.26 (xxxii)}
Supply and erection of suitable compression type brass Cable glands for underground Cable:-{HSR 31.28 (v)} (v) 120 Sq mm to 185 Sq mm cable 3 to 3 ½ Core
Street Lights:- III. (xv) Supply and erection of 32 mm dia meter 1.5 m long bracket (B-class) making an angle of 10o to 15o with horizontal plane for mounting street light fitting fixing of G.I. brackets on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps Including cost of cutting, welding of G.I pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. {HSR 31.30 III (xv)}
Miscellaneous:- (i) Supply of M.S. pipe ( B-Class) for suspension rod of ceiling fan including theading if required.{HSR 31.35(i)(a)} (a) 15 mm dia
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. {HSR 31.40 (i)} (i) Cable size 1.5 sqmm
(ii) Cable size 2.5 sqmm {HSR 31.40 (ii)}
(iii) Cable size 4 sqmm {HSR 31.40 (iii)}
(iv) Cable size 6 sqmm {HSR 31.40 (iv)}
(v) Cable size 10 sqmm {HSR 31.40 (v)}
S/E of PVC conduit pipe ISI marked (medium) recessed in wall/ceiling etc. including cost of PVC bends, insepection box and all other material required to complete the job in all respect upto to the entire satisfication of the Engineer-in charge of the work.{HSR 31.44 (b)} (b) 25 mm dia
Supply and erection of copper lugs including crimping etc. upto the entire satisfaction of Engineer-in-charge of the work.{HSR 31.45 (a)} (a) 1.5 sqmm to 2.5 sqmm
(b) 4 sqmm to 6 sqmm {HSR 31.45 (b)}
Providing and fixing modular type accessoriesm of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 31.56) 10 amp. 1 way switch
20 amp. Switch (HSR 31.56)
10 amp. Socket (HSR 31.56)
16 amp. Socket (HSR 31.56)
Bell push (HSR 31.56)
Fan Regulator (HSR 31.56)
Call bell Dring-Dong (monitca) (HSR 31.56)
Blinking plate (HSR 31.56)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate incluidng concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete In all respects. (HSR 31.57) 1 & 2 Modules
3 Modules (HSR 31.57)
4 Modules (HSR 31.57)
6 Modules (HSR 31.57)
8 Modules (HSR 31.57)
12 Modules (HSR 31.57)
Supply installation testing and commissioning of wall free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet required hardware 3 mm thick bakelite sheet providing all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/Red oxide primer followed by 2 coats of powder cating in grey or required shade after rinsing. the panle having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/ switch wear.Transparent arcylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra tiems side walls and cable alley compartments shall be haiving bolted type doors with detachable extension type strcture. the panel will be complete with control wiring ( copper) and fuse protection ( only outer area on all sides shall be measured ) (HSR 31.63)
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat srinkable PVC insulation complete in all respect. (HSR 31.64)
S/E of mark double walled corrugated ( DWC) HDPE pipe laid 1 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket/ cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer incharge of the work. {HSR 31.67(i)} (i)HDPE pipe 63/50 mm outer dia/inner dia
Supply & Erection of hot dip Galvanized octagonal pole of 3 mm thickness with base plate including cost of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manutacturer design should be hot dipped galvanzied pole complete with door locking arrangement terminal plate consisting of 2 Nos. 100 A, 4 pole natural links including connection etc. with suitable connecting arrangement for 2 Nos. MCBS kit kat including R.C.C. 1:1:5:3 for foundation of size 0.7 M X 0.7 M X 1.8 M with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C. for fixing the pole with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer-in charge of work. {HSR 31.68 (i)} (i) 7 Mtr. Long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220x220x12 mm
S/E of heavy duty 4 pole on load change over load breaker switch comprising of switch 63 to 400 amp. Suitable for operation on 4.15 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel 7 including making necessary connection with petty material required to complete the job.{HSR 31.74 (iii)} (iii)200 amp. 4 pole ON load changeover switch
Supply and laying of multicore telephone cable condutor size 0.51 mm bright annealed copper condutor PVC insulated and sealed in existing pipe channel and making necessary coneection complete in all respect up to the entire satisfaction of the Engineer-in chage of the work. {HSR 31.78 (i)} (i) 2 Pair telephone wire
(iii)10 Pair telephone wire {HSR 31.78 (iii)}
S/E/T/C of cat- 6 cable in existing pvc conduit pipe/pvc channel complete in all resepect with all labour and material required to complete the jon in all respect. (HSR 31.80)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator etc. wih rating 5 star {NS} i) 1200mm sweep. Make: Usha, Orient, Crompton.
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. i) 1400mm sweep. Make: Usha, Orient, Crompton
S/E of surface/wall mounted ≤36W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 4000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial)Make: Philips, Havells, Wipro, Bajaj. (NS)
Supply of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 300mm(12”) sweep Make: Orient, Usha, Khaitan, Havells. (NS)
S/E of recessed type 42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600k to 6500k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥140 lm/w, Average life >50000hours, complete with all accessories as required with connections.Code :- PLANO2*2PLR42WLED865S (Industrial) Make Havell's or Philiphs , Bajaj (NS)
S/E of Single Arm bracket 1.5mtr Long 40mm dia G.I bracket with suitable seelve as per pole top dia galvanised with all petty material required to complete the job for satisfaction of Enginneer in charge. (NS)
S/E of Double Arm bracket 1.5mtr Long 40mm dia G.I bracket with suitable seelve as per pole top dia galvanised with all petty material required to complete the job for satisfaction of Enginneer in charge. (NS)
SITC of astronomical time switch degree of protection IP 20 two module voltage 230 V AC, 50 Hz Astronomical programmable every one minute back up of 6 years 28 memory locations, current capacity 16A with 1 changeover (ICO) total 28 programmes. Ambient temperature -10 degree to +55 degree with 32 amp. contactor three phase with 32 amp. DP MCB and 25 amp. SP MCB. Make: Indo Asian, Philips, Havells, Wipro, Bajaj or HPL (NS)
S/E of 125KVA Silent DG set having frequency 50Hz PF 0.8 voltage 415V 3 phase , governing class as per ISO 8528 part - V G3 , noise level < 75 , fuel consumption at 100% load is 27.4ltr , at 75% load is 20.2 ltr at 50% load 15.3 ltr fuel tank capacity 230 ltr weight of genset with canopy approx 2290kg on wet, overall dimensions 3200*1300*1795mm , 12V electrical battery , engine kirloskar / cumins alternator stamford / kirloskar make rated output 114.7 to 156 with 6 no. cylinder bore x stroke 105*125 rated speed 1500 lube oil sump capacity 14 coolant capacity 21 , insulation class H alternator efficiency 92.5 max at 100% load , max time to build up rated voltage at rated RPM < 20% with suitable size solid foundation with reinforcement & CC foundation as per standard specifications as per manufacturer and erection with connection of cables , earthings etc and petty material required to complete the job in all respect with satisfaction of EIC Kirloskar green / cummins. (NS)
S/E of Wall Mounting Fan 300 mm sweep with mesh wire guard Having 3 speed control ISI Mark Make Bajaj,Orient,Havells (NS)
Supply, Installation, Testing and Commissioning of Interactive Flat Panel Wall Mount - Technology TFT LCD with DLED Backlit; Display size (diagonal) 86" or Higher. Aspect Ratio 16:09; Resolution 3840 x 2160 4K Ultra HD; Flicker Free Yes with Blue Light Filter; static contrast ratio 1200:1 (typ): brightness 350 nits:display clour 1.07B colours:input ports HDMI x 3:VGAx1;display portx1;audiox1;CVBS(AV);RS232x1;PC slotx2;Slotin for pc built inx1;Wifi module slot built in x 1;output port HDMI x1;audio (earphone out)x1;SPIDFx1;LAN RJ45 x1;USB3.0 type A x3;2.0 typeA x3;2.0 type B(for touch) x2 ;Speaker 16 w x2 ;Touch type :IR recognition;touch resolution:32767x32767,Touch point:20 points;writing :10 points; response time<15ms;support: windowsVersion:5.1;CPU:ARM quad core cortex A53 1.2Ghz;GPU ARM Mali-450 MP 4;Memory:2 GB;Storage:16GB eMMC;Networking:10/100M auto-identtification and DHCP;Anti Scratch-Anti Glare Minimum 7 H scratch resistant and anti glare ;mirror extending flexibility to allow content to be mirrored on two IFB simultanesouly through HDMI out.Save option built in save option directly to Google Drive and One Drive. (NS)
Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. (NS) (i) 10 pair DP Make:- DELTON/ FINOLEX/ HAVELLES
S/E of Telephone Jack Modular type complete in all respect. Make: Anchor or equiv.(NS)
Supply, Installation and commissioning of 1 x 20 KVA UPS Each UPS of 20 KVA/18 KW should have following specifications in addition to tender requirements : True online double conversions, IGBT Rectifier & inverter based UPS. Three phases Input/ three phase output with SMF batteries Suitable for 30 Min backup on Full load (20 KVA) at 0.8 output power factor. Input voltage range 360-478V at 100% load, 220-478 V @ 50% load. Input power factor 0.99,Output THD is less than 3% for linear load. Less than 5 % for nonlinear load. Crest factor 3:1, over load 125% for 10 min, 150% for 1 min and should be able to operate continuously at 115% load on bypass mode. Battery voltage Adjustable from 384VDC to 480 VDC on site. Battery Bank sizing as 42 AH x 40 nos. X 1 String. Battery type should be Valve regulated lead-acid (VRLA) of make Exide/Panasonic/QUANTA/Rocket. Audible noise level should not exceed 63 dB (A). Parallel communication port, RS232. USB EPO and SNMP interface, BMS interface are required. EMC-IEC62040-2 safety-IEC62040 II operating temperature 0-40 deg C, relative humidity 95% Non-Condensing. No derating e to 40 Deg temp.. UPS shall have inbuilt Input Isolation Transformer. static by pass and manual by pass built in required. Third party test report through accredited lab like TUV is required for IEC 62040-3 and IP20. UPS should be provided with environment monitoring probe to measure temperature and humidity of UPS room. UPS shall have dust filter sat Air Inlet level to improve UPS reliability. LCD Display indicating all important parameters. SNMP software should be compatible to Microsoft windows XP, Windows Vista, Window 8, Window server 2003 R2, UPS software should be compatible to google chrome, Mozilla fire fox and Microsoft internet explorer. Battery rack, battery interlinks battery breaker, battery to UPS cable as required should be provided with UPS systems. (NS) Make: Elnova, Eaton, Peagasus,GE,Gutor
Supply, Installation, Testing and Commissioning of Digital Podium – Material: Mild Steel; Should have Tray for Keyboard. ( Keyboard Dimension Standard Lenovo Keyboard); Should have built-in Visualizer and 19” Interactive Panel .It should also have the flexible options in sizes for the 19” or 21.5” Interactive Panel to fit in; Interactive Panel motorised positioning up and down as per the user convenience; Should have single Sliding tray to Protect the Interactive panel and for the controller;The top of the Podium should be wooden. Should have a space for the Desktop PC and for the equipments to fit in as per the International standards. Sliding Shelf 1) For Placement of extra laptop or Document 2) Drawer For Visualizer with Lock; Door Lock – Yes. Central Control System Should be able to control from the Controller with easy identified keys - Projector On Off , Motorised Screen Up & Down , Switching between PC, Visual Presenter and laptop, Volume Control. Front Panel should have- 17 Membrane keys for control, Power Plug 0f 220 Volt Power out for Laptop etc.,VGA Port X 01, 3.5mm Audio Input X 01,Network Port wired Internet x 01,USB X 02 Ports ,Ports for 6.35mm Microphone Input Back Panel of the Controller should have - Should have Projector IR Controller ,Should have 1 RS 232 Projector Control ,Should have 2 x 2 VGA matrix, Should have 2 HDMI Input and 1 HDMI Out, Should have 2 USB Ports for front, Connectivity, Should have Network Port for front connectivity, Should have2 Video In and 2 Video out, 2 Audio (Left) in , 2 Audio (Right) in, Should have 1 x Projector Power , 1 x Electric Screen Power; Built-in inputs on the left hand side : HDMI x 1, VGA x 1, USB Ports x 2, Power Plug x 1, Audio Mini In x 1, RJ 45 x 1, Microphone Input x 1, Video In x 1, Audio in (Left and Right) x 2 Signal Switching :The Interactive Monitor touch should work independently for the both Laptop and PC. (NS)
CCTV:- Supply Installation testing & commissioning of 4MP IP Network Dome Camera with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Image Sensor : 1/3” 4 Megapixel Progressive scan CMOS sensor or better Effective Pixels : 2688(H)x1520(V)) or better Electronic Shutter : Auto/Manual, 1/3(4)~1/100000s Scanning System : Progressive Mini. Illumination : 0.08Lux/F2.0(Color); 0Lux (IR on) S/N Ratio : More than 50dB Min. IR LEDs Length ≥50m IR Leds : 1 Day/Night : Auto(ICR) / Color / B/W Back Light Compensation : BLC / HLC / WDR(120DB) White Balance : Auto/Natural/Street Lamp/Outdoor/Manual Motion Detection : Off/On (4Zone, rectangle) Focal Length : 2.8mm Region of Interest : off/on(4Zone) Angle of View : H: 104° ,V: 57° Video Compression : H.265+/ H.265 Resolution : 4MP (2688x1520)/3MP(2304x1296)/ 2MP(1920× 1080)/720P(1280× 720) Frame Rate (3 Stream) : Main stream (4MP (1 ~ 25/30fps)) & Sub stream : D1(1 ~ 25/30fps)& Third Stream : 720P (1 ~ 25/10fps) Digital Zoom : 16x Bit Rate : H.265: 14 ~ 9984Kbps Network Ethernet : RJ-45 (10/100Base-T) Flip : 0°/90°/180°/270° Protocol : HTTP; HTTPs; TCP; ARP; RTSP; RTP; UDP; SMTP; FTP; DHCP; DNS; DDNS; PPPOE; IPv4/v6; QoS; UPnP;NTP; Bonjour; 802.1x; Multicast; ICMP; IGMP; SNMP Compatibility : ONVIF SD Card : Min 128GB SD card support Power Supply : DC12V, PoE (802.3af) Working Environment : -30°C~+60°C / Less than 95%RH (no condensation) Ingress Protection : IP67 Audio Interface : Built-in-Mic Intelligence (IVS) : Tripwire, Intrusion, Object Abandoned/Missing , Advanced Intelligent Functions : Face Detection Certification : CE, FCC,UL alongwith test report of the product (NS) MAKE : DAHUA/PANASONIC/HONEYWELL/HYUNDAI
Supply Installation testing & commissioning of 2MP WDR IR Bullet Network Camera with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Image Sensor : 1/2.8” 2 Megapixel Progressive scan CMOS sensor or better Effective Pixels : 1920(H)x1080(V)) or better Electronic Shutter : Auto/Manual, 1/3~1/100000s S/N Ratio : More than 50dB IR Distance ≥60m IR Leds : 4 Day/Night : Auto(ICR) / Color / B/W Back Light Compensation : BLC / HLC / WDR(120DB) White Balance : Auto/Natural/Street Lamp/Outdoor/Manual Focal Length : 3.6mm Angle of View : H: 87° ,V: 46° Video Compression : H.265+/ H.265 Resolution : 1080P(1920x1080)/1.3M(1280x960)/ 720P(1280×720) Frame Rate (3 Stream) : Main stream 1080P (1~50/60fps) & Sub stream : D1(1 ~ 50/60fps)& Third Stream : 1080P (1 ~ 25/30fps) Bit Rate : H.265: 14K ~ 9984Kbps Motion Detection : Off/On (4Zone, rectangle) Region of Interest : off/on(4Zone) Flip : 0°/90°/180°/270° Network Ethernet : RJ-45 (10/100Base-T) Protocol : HTTP; HTTPs; TCP; ARP; RTSP; RTP; UDP; SMTP; FTP; DHCP; DNS; DDNS; PPPOE; IPv4/v6; QoS; UPnP;NTP; Bonjour; 802.1x; Multicast; ICMP; IGMP; SNMP Compatibility : ONVIF Digital Zoom: 16x SD Card : Min 128GB SD card support Power Supply : DC12V, PoE (802.3af) Working Environment : -30°C~+60°C / Less than 95%RH (no condensation) Alarm : 1 channel In: 5mA 5VDC, 1 channel Out: 300mA 12VDC Vandal Resistance : IK10 Ingress Protection : IP67 Casing: Metal Audio Interface : 1/1 Channel In/out Intelligence (IVS) : Tripwire, Intrusion, Object Abandoned/Missing , Advanced Intelligent Functions : Face Detection Certification : CE, FCC,UL alongwith test report of the product. (NS) MAKE : DAHUA/PANASONIC/HONEYWELL/HYUNDAI
Supply Installation testing & commissioning of Video Management Server with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications (NS)
Supply Installation testing & commissioning of outdor 4*4 box with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.(NS) MAKE : STRONGER/MOLEX/AMP)
Supply Installation testing & commissioning of 6TB surveillance hard disk with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : WD-PURPLE/SEGATE
Supply Installation testing & commissioning of 12 U Server Rack with all Accesserieos with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/VPRO/DYNAMIC/APW/I-BALL
Wifi system:- Supply Installation testing & commissioning of AP Management License with 3 years comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUCKUS/CISCO/ARUBA
Supply Installation testing & commissioning of Indoor Access Point with secure Mounting Bracket and with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : The Access Point should have 2 auto MDX, auto-sensing 10/100/1000 Mbps RJ-45, with POE support on one port, and one USB port. AP should be IOT ready from day 1. The APs should support the IEEE 802.11a, 802.11b, 802.11g , 802.11n & 802.11ac Wave2 standards. It should support minimum 3 MU-MIMO clients simalteniously. The AP must support Dual Band Concurrent Operation - 2.4GHz and 5GHz. Should support 3 spatial streams on both radio bands for an aggregate capacity of 1.75 Gbps including 450Mbps on 2.4Ghz. The AP shall have a Minimum Rx Sensitivity of -100 dBm. The access points should be centrally managed. In some small isolated environments the AP should be able to function as a full-fledged stand-alone access point without the requirement of a controller. Security mechanisms should be in place to protect the communication between the Access Point controller and the Access Points. Since most radio interference come from the WLAN network itself the vendor should specify what mechanisms such as beam steering/ adaptive antenna technology/ beamforming are available in combination to focus the energy on the destination STA and minimize radio interference with the surrounding of the AP. The vendor should specify if the activation of such feature is still compatible with 802.11n spatial multiplexing. Since the WLAN network will be using an unlicensed band the solution should have mechanisms that reduce the impact of interference generated by other radio equipment operating in the same band. The access point should be able to detect clients that have dual band capability and automatically steer those client to use the 5GHz band instead of the 2.4GHz band. The antennas to be dual polarised and should be integrated inside the access point enclosure to minimize damage and create a low profile unit that does not stand out visually. The access point should support 802.1q VLAN tagging The access point should support WPA2 enterprise authentication and AES/CCMP encryption. AP should support Authentication via 802.1X and Active Directory. Implement Wi-Fi alliance standards WMM, 802.11d, 802.11h and 802.11e Note:- The complete description and specification/details of this item may be seen in item No. 288 under sub-head Bill of Quantities of bid document uploaded with this tender, before quoting rate of this item the contractor may see the pdf of bid document uploaded with this tender. The job of this items shall be got done as per bid document uploaded. (MAKE : RUCKUS/CISCO/ARUBA) (NS)
Internet :- Supply Installation testing & commissioning of 48 Port Non POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support having following technical specifications : Switch architecture should be Fixed Form factor/ stackable based. Switch should have wire-speed, non-blocking and fanless designe Architecture. Switch should have minimum of 48 x 10/100/1000 Mbps RJ45 ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port with 10G MMF. Switch should have minimum of 136 Gbps or more data switching capacity and 95 Mpps or more forwarding throughput. Access Switch should have stacking capability with minimum stacking bandwidth of 40Gbps and should support a minimum of 8 units in a stack from day one. Switch should support min 16 K MAC addresses and min 4000 active VLANs. Switch should have full Layer 2 features like STP, RSTP, MSTP/PVST, LACP/IEEE802.3ad, ACL, QoS and IGMPv1/v2/v3 from day one. Switch should have Static Routing for IPv4 & IPv6 from day1. Access Switch should be upgradable to support advance Layer 3 features like, RIPv1/v2, OSPF v2, OSPFv3, and HSRP/VRRP in future with an additional software license upgrade. Should support 4K IGMP Groups. Should support 8 queues per port and security protocols like RADIUS, TACACS/TACACS+, AAA & SSH. Switch should be quoted with 3 years direct OEM TAC support and Next Business day hardware shipment. Proposed switch should be IPv6 logo certified, including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : RUCKUS/CISCO/HP (NS)
Supply Installation testing & commissioning of 24 Port POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Switch should offer Wire-Speed and Non-Blocking Switching with 24 10/100/1000 RJ45 PoE/PoE+ Ethernet ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port . Access Switches should support non-blocking switching fabric capacity of minimum 88 Gbps and minimum line-rate forwarding capacity of 57 Mpps. Access switch should support minimum 16K MAC addresses and minimum 4K active VLANs. Access Switch should have stacking capability with minimum stacking bandwidth of 40Gbps and should support a minimum of 8 units in a stack from day one. Access switch should support up to 8 hardware queues per port Access Switch should support full Layer 2 features like STP, RSTP, LACP, ACL, QoS, IGMP v1/v2 from day 1. Access Switch should support basic L3 features like IPv4 & IPv6 static routing, Layer 3/4 ACLs, ECMP, virtual interfaces and routed interfaces from day 1. Access Switch should be upgradable to support advance Layer 3 features like, RIPv1/v2, OSPF v2, OSPFv3, and HSRP/VRRP in future with an additional software license upgrade. Access Switch should support minimum 1K IPv4 routes. The Access Switch should support IPv6 management features like IPv6 ping, IPv6 trace route, IPv6 Telnet, IPv6 TACACS, IPv6 and IPv6 RADIUS. All Switches and Transceivers should be of same OEM make. Access switch should support minimum 4K ACL rules ACL per Switch. Access switch should support SNMP v1/v2/v3, SSH, NTP and web management Access switch should have 1G of RAM and 2G of Flash Memory. (NS) MAKE : RUCKUS/CISCO/HP
Supply Installation testing & commissioning of 10GBASE-SR,SFPP MMF LC CONNECTOR with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : BROCADE/CISCO/HP
Supply Installation testing & commissioning of DIRECT ATTACHED SFPP ACTIVE COPPER with 10G speed, 1M with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : BROCADE/CISCO/HP
Supply Installation testing & commissioning of 1 Port British Style Shuttered Faceplate (3*3) including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of SL Series Category 6 Modular Jacks, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of Category 6 Patch Cord 7feet, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of 24Port Unloaded Straight Jack pannel, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of Horizontal PVC Cable Manager - 1U , including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/Molex/belden
Supply Installation testing & commissioning of 12U Wall Mount rack with front glass door lockable, Fans 90 Cfm 230 Vac, PDU Horizontal 5Amp with 6 Schokets, Cantilever Tray-1U, Horizontal PVC Cable Manager and Hardware front panel Mtg. including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/NETRACK/VPRO
Ductable Type indoor unit - VRV Supply, installation, testing and commissioning of ducable type indoor unit with cordless remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. Ductable Units 2530 CFM /7.5 TR (NS) Make:-Fujitsu, General, Trane, York, Gree
4-way Cassette Type indoor unit - VRV Supply, installation, testing and commissioning of 4-way Cassette type (Round flow) indoor unit with cordless remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. 4-Way Cassette Units 888 CFM / 2.5 TR (NS) Make:-Fujitsu, General, Trane, York, Gree
4-way Cassette Type indoor unit - VRV Supply, installation, testing and commissioning of 4-way Cassette type (Round flow) indoor unit with cordless remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. 4-Way Cassette Units 630 CFM /2.0 TR (NS) Make:-Fujitsu, General, Trane, York, Gree
4-way Cassette Type indoor unit - VRV Supply, installation, testing and commissioning of 4-way Cassette type (Round flow) indoor unit with cordless remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. 4-Way Cassette Units 412 CFM / 1.2 TR (NS) Make:-Fujitsu, General, Trane, York, Gree
Touch screen controller for indoor units controller - VRV Supply, installation, testing and commissioning of LED Display Type Centralized Controller (Which can control 364 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls.(NS) Cordless Remote Control Make:-Fujitsu, General, Trane, York, Gree
Corded Remote Control (for item No. 102) (NS) Make:-Fujitsu, General, Trane, York, Gree
Supply, installation, testing and commissioning of imported refrigerant Y- joints/ headers. (NS) Make:-Fujitsu, General, Trane, York, Gree
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. (NS) Make:- Mandev, Totaline, Mexflow, Parasmani . 28.6 mm OD
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. (NS) Make:- Mandev, Totaline, Mexflow, Parasmani . 22.2 mm OD
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. (NS) Make:- Mandev, Totaline, Mexflow, Parasmani . 19.1 mm OD
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. (NS) Make:- Mandev, Totaline, Mexflow, Parasmani . 15.9 mm OD
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. (NS) Make:- Mandev, Totaline, Mexflow, Parasmani . 12.7 mm OD
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. (NS) Make:- Mandev, Totaline, Mexflow, Parasmani . 9.5 mm OD
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. (NS) Make:- Mandev, Totaline, Mexflow, Parasmani . 6.4 mm OD
Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller.(NS) Make:-National, Belton Cable, KEI , Polycab
Providing and fixing and in position the following PVC pipes for condensate drain duly insulated with kinny foam & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the shaft dor vertical risers) (NS) Make:-Suprime, Polypack, Polycab, 25 mm dia
Providing and fixing and in position the following PVC pipes for condensate drain duly insulated with kinny foam & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the shaft dor vertical risers) (NS) Make:-Suprime, Polypack, Polycab, 32 mm dia
Air Distribution Site Fabricated Duct Supply,Fabrication , Installation and testing of sheet metal ducts in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. (NS) 0.63mm (24 gauge) GSS
Supplying, installing, testing and balancing of aluminium supply/return air grills of various sizes. Each grill shall be with fixed horizontal front bar at Zero/15 Deg deflection through the collar and register. (NS) Aluminium Exh./return air grilles without damper of make as approved by Engineer-In-charge.
Supplying, installing, testing and balancing of Aluminium Return air 2- Slot Diffuser without damper of make as approved by Engineer-In-charge. (NS)
Supplying, installing, testing and balancing of Aluminium Volume control dampers for Slot Diffusers & supply air collar of Linear Grille of make as approved by Engineer-In-charge. (NS)
INSULATION WORKS MECHANICAL INSULATION DUCT LINE ACOUSTIC TREATMENT Supply and Application of acoustic lining within the supply air duct Fiber Glass wool of 32kg./m³ density). as per specifications and drawings of make as approved by Engineer-In-charge. (NS) 25mm thick (For Duct)
SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0.032 W/moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0.15ng/Pa.Sec.m. (NS) 9 MM Thick of make as approved by Engineer-In-charge.
ASSOCIATED ELECTRICAL WORKS The rates for the distribution boards from the Breakers and instruments shall also include the following : Wiring for light / Fan points with 1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible FRLS wires of approved make in 1.6 mm thick 25 mm dia MS conduit including cost of providing & fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a 6 amp 240 Volt Modular Plate type switches of approved quality, colour, make and design with moulded cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper earth wire for loop earthing etc. complete TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link. All MCB’s shall be of minimum 10 KA breaking capacity. The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic microprocessor releases as per BOQ and following : i. MCCB rating upto 250 Amps with thermal magnetic releases. ii. MCCB above 250 Amps with microprocessor releases. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. i. IP 42 for indoor panels. ii. IP 55 for ODU panel. Note:- The complete description and specification/details of this item may be seen in item No. 323 under sub-head Bill of Quantities of bid document uploaded with this tender, before quoting rate of this item the contractor may see the pdf of bid document uploaded with this tender. The job of this items shall be got done as per bid document uploaded. (NS)
CABLING (POWER ) Power Cabling and Earthing: Supply, installation, testing & commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved) of make approved by Engineer In-charge. (NS) 4Cx16 Sqmm
Control Cabling Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required of make approved by Engineer In-charge. 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. (NS)
Control Cabling Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required of make approved by Engineer In-charge. 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. (NS)
Control Cabling Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required of make approved by Engineer In-charge. 300 mm. Width x 50mm. Depth x 1.6mm. Thickness. (NS)
Providing and fixing following size of G.I. strip / G.I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring / on cable tray/ on surface including G.I. clamps etc. complete as required of make approved by Engineer In-charge. 6 SWG G.I. wire
Fire Hydrant System:- Supply, Installation, Testing & Commissioning of: Single headed, CI /SS ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63mm dia instantaneous type female outlet complete with Gun Metal cap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type 'A') (NS)
Supply, Installation, Testing & Commissioning of: First-Aid Fire Hose Reel wall mounting swinging type complete with drum, bracket, ball valve and 20mm dia.x 30M long high pressure Hose Reel tubing as per IS:444 with Gun Metal shut-off nozzle having 5mm dia. orifice. The Hose Reel shall strictly confirm to IS : 884-1985. (NS)
Supply, Installation, Testing & Commissioning of: Non-percolating flexible hose (RRL type-'A') ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneous type SS/ Gun Metal 63 mm dia. IS marked Male and female couplings (IS:903) bound and riveted to hose pipe with Gun Metal rivets and 1.5 mm Gun Metal wire. (NS)
Supply, Installation, Testing & Commissioning of: SS 63mm dia short size branch pipes with 20 mm dia nozzle with 63mm instantaneous coupling ISI marked (IS: 903) (NS)
Supply, Installation, Testing & Commissioning of Gun Metal Fire Brigade connection (Suction collecting head) consisting of 63 mm dia instantaneous type male coupling with built-in check valves and 100 mm dia. flanged outlet complete with bolts, nuts and rubber insertions as required as per IS:904-1983. (NS) Two Way
Supply, Installation, Testing & Commissioning of: Weather proof hose cabinets fabricated from 16 g M.S. Sheet with full glass door and locking arrangement, suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (NS)
Supply, Installation, Testing & Commissioning of: Air-release Valve. (NS)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 200 mm dia IS 1239 (Make: Tata/ Jindal)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 150 mm dia IS 1239 (Make: Tata/ Jindal) with wraping coat
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 150 mm dia IS 1239 (Make: Tata/ Jindal)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 100 mm dia IS 1239 (Make: Tata/ Jindal)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 80 mm dia IS 1239 (Make: Tata/ Jindal)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 65 mm dia IS 1239 (Make: Tata/ Jindal)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 50 mm dia IS 1239 (Make: Tata/ Jindal)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 32 mm dia IS 1239 (Make: Tata/ Jindal)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (NS) 25 mm dia IS 1239 (Make: Tata/ Jindal)
Supply, Installation, Testing & Commissioning of slim seal Dual plate non-return valves (PN 1.6) complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes. (NS) 150 mm dia
Supply, Installation, Testing & Commissioning of slim seal Dual plate non-return valves (PN 1.6) complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes. (NS) 100 mm dia
Supply, Installation, Testing & Commissioning of slim seal Dual plate non-return valves (PN 1.6) complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes. (NS) 80 mm dia
Providing and fixing Slim seal Butterfly valves (PN 1.6) complete with matching flanges rubber insertion, nuts. bolts and washer etc. of following sizes. (NS) 150 mm dia nominal bore
Providing and fixing Slim seal Butterfly valves (PN 1.6) complete with matching flanges rubber insertion, nuts. bolts and washer etc. of following sizes. (NS) 100 mm dia nominal bore
Providing and fixing of Ball valve 50 mm dia, complete in all respect of make approved by Engineer- In charge. (NS)
Structure of support pipe made of MS pipes of different dias, complete in all respect of make approved by Engineer- In charge. (NS)
Providing, fixing, testing and commissioning 15 mm Chrome plated gunmetal sprinkler head with quartz bulb set to operate at specified 68 degree temperature pendent, complete in all respect of make approved by Engineer- In charge (NS)
Supplying and fixing Fire Sprinkler Fexible Drop 1000 mm, complete in all respect of make approved by Engineer- In charge. (NS)
Supplying and fixing of rosette plate for sprinkler, complete in all respect of make approved by Engineer- In charge. (NS)
FIRE PUMPS, VALVES & ACCESSORIES Supplying, Installation, Testing & Commissioning of Local Fire authrity approved Electric Driven Main fire pump for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D and E (A) Horizontal Single / Multi stage Centrifugal End suction, back pull type pump complete (B) Material of construction : Pump Casing - Cast Iron, Impellor-Bronze, Shaft-SS 410, Packing- Mechanical Seal (C) Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head (D) Squirrel cage induction motor suitable for 3 phase, 415 V, 50 HZ, Ac supply 2900 RPM T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible coupling, coupling guard complete in all respect . (E) Common bed plate fabricated from mild steel channel for installation of pump and Motor (F) Suitable cement concreat foundation duly plastered with anti vibration pads. 1620 LPM suitable for 70 Mtr Head, single stage, 2900 RPM Make: Kirloskar/ M&P. (NS)
SITC of Local fire authority approved Diesel Engine driven Pump (of make approved by Engineer- In charge) suitable for automatic operation as per discharge defined beolw consisting of the following details given as A, B, C, D, E and F . (A) Horizontal Single / Multi stage Centrifugal End suction, back pull type pump complete for delivery of below mentioned discharge complete (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal (C) Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head (D) Radiator cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter minimum 10 M length, with muffler, day oil tank of 300 ltrs capacity with first charge and hand operated oil pumping set. (F) Suitable cement concreat foundation duly plastered with anti vibration pads. 1620 LPM suitable for 70 Mtr Head, single stage, 1800 RPM (NS)
SITC of Horizontal single stage Jockey pump (Bharat-II) (of make approved by Engineer-In charge) with CI Body, Bronze impellor, SS shaft, mechanical seal coupled with Squirrel cage induction motor for automatic operation suitable for three phase, 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed plate fabricated from mild steel channel, Suitable cement concreat foundation duly plastered with anti-vibration Pad. 180 LPM suitable for 70 Mtr Head.(NS)
SITC of Pressure Switch, complete in all respect of make approved by Engineer- In charge (NS)
SITC of Pressure Gauge, complete in all respect of make approved by Engineer- In charge (NS)
SITC ofFoot valve 150 mm dia, complete in all respect of make approved by Engineer- In charge (NS)
SITC of Y stainer 150 mm dia, complete in all respect of make approved by Engineer- In charge (NS)
SITC of Y stainer 80 mm dia, complete in all respect of make approved by Engineer- In charge (NS)
SITC of Air Vessel: NB: 200mm (8mm thik) H:1.mtr. Including air release valve and Draining arrangement, complete in all respect of make approved by Engineer- In charge (NS)
AV Science And Technologies Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .