| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 CrAccepted-AOC | ₹8.3 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹8.6 Cr+₹28.3 L (3.39%)Rejected-Finance NOT SPECIFIED | ₹8.6 Cr+₹28.3 L (3.39%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹9.0 Cr+₹63.8 L (7.65%)Rejected-Finance | ₹9.0 Cr+₹63.8 L (7.65%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹9.1 Cr+₹81.0 L (9.71%)Rejected-Finance | ₹9.1 Cr+₹81.0 L (9.71%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹11.4 Cr+₹3.1 Cr (37.2%)Rejected-Finance PROP ZISHAN ALI ADARSH NAGAR NEW BUS STAND RAMGARH CANTT RAMGARH | ₹11.4 Cr+₹3.1 Cr (37.2%) | L5 | Rejected-Finance BEING L5 |
Tender Value
₹8.3 Cr
EMD Value
₹7.4 L
Closing Date
27 Apr 2022, 6:00 pmClosed
CE AF UDHAMPUR
CE AF UDHAMPUR ZONE
PROVN OF AF SHARE OF WORKS FOR MAFI-II PROJECT AT AF STN SRINAGAR
2022_MES_505474_1
CEAFU-12/2021-22
Open Tender
Civil Works
Lump-sum
600 days
SRINAGAR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
GE (AF) SRINAGAR
₹7.4 L
Yes
2 Jul 2022
3 Feb 2022
2 May 2022
3 Feb 2022
27 Apr 2022
5 Apr 2022
Amount
Total amount of Sch 'A' Part-I (BUILDING WORK)
Total amount of Sch 'A' Part-II (INTERNAL ELECTRIFICATION WORK)
Total amount of Sch 'A' Part-III (Section-I) (INTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' part-III (Section-II) (INTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F C P health Faucets with flexible tube 15mm dia for EWC including all connection complete all as specified and directed.
Total amount of Sch 'A' Part-IV (Section-I)( EXTERNAL ELECTRIFICATION WORK)
Total amount of Sch 'A' part-IV (Section-II) EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
(c) CT shall be resin-cast and shall be free from absorption of moisture and be connected at outgoing side ,shall be provided with 3(three) nos dual core dual ratio current transformer having following particulars :- (i) Ratio - 100-50/5-5A (ii) No of core - Two (for metering and protection) (iii) Accurcy class 5P 15 for protection core and 0.5 for metering core . (iv) VA Burden - 15VA for protection core and 10VA for metering core. (v) Short time - 18.4 KA for 1 second d)Self powered microprocessor controlled numeric relay comprising of three over current , one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxliary supply.Make- ABB/SIEMENS (III) Bus coupler Vacuum Circuit Breaker 630A, HT, 11KV three phase, AC supply, 350MVA ,18.3KA breaking capacity, short circuit ratings 1 second, complete:- with out any protection and metering-02No Note : Both the buscoupler should be electrical and mechanical interlocked so as to avoid turning on of both VCBs simultaneously.Bus coupler to be provided with Trunking chamber and meet out existing panel specification.
VCB PANEL SHOULD COMPRISE OF THE FOLLOWING FEATURES :- (a) Push buttons for accepting faults and reset. (b) LED indicating lamps for (duly control wired up) (i) Auto strip (ii) Spring charge (iii) Fault Alarm (iv) Trip Circuit Healthy (v) Trip circuit Unhealthy (vi) Breaker ON (vii) Breaker OFF c) RS 485 communication d) Motor operated spring stored energy trip for closing and opening of the breaker. e) Manual charging / operating arrangement. f) Fuses for metering and protection system g) One No. internal bus earthing with flat GI strip of size 50x 6mm h) one No. of space heater with thermostat i) One No. of inside lamp with switch ( 40W 230V) j) One No. of plug point with switch( 5A, 230V) k) Copper bus bar common for out going feeders with PVC sleeves l) Complete control panel wiring with copper wire of size not less than 2.5 sqmm m) Civil design for foundation should be done all as per instructions manual of manufacturer.
Note:- (a) The VCB shall be tested for High Voltage test, Primary Injection test & Secondary Injection test individualy at site after erection before commissioning and the same is deemed to be to included in the quoted rate. (b) VCB shall be drawout type and their should be provision of extendable. (c) Whole scheme shall be as per schematic line diagram arranged by the contractor from manufracture and shall be approved by the GE before execution. (d) Unit rate shall included the cost of danger notice baord, 11KV grade 25 cm CRCA ISI Marked, 11 KV grade, chequred type rubber mat 1 meter width and length equvalent to the width of the panel, Two sets of operating and maintenence manual, spares list, periodical mainenance chart / manual, lay out of panel / wiring shall be included in the rate quoted, (e) Cost of any civil work required to install the panels shall be deemed to be included in the rate of panel
Note :- (i) PT shoud be 3 Phase , 5 Limb or 3 single phase with star connection made to form 3 phase . (ii) PT shall be resin cast type and connected at Incoming side. Shall be mounted on with drawable rack/housing complete. (e) CT shall be resin-cast and shall be free from absorption of moisture and be connected at outgoing side ,shall be provided with 3(three) nos dual core dual ratio current transformer having following particulars :- (i) Ratio - 100-50/5-5A (ii) No of core - Two (for metering and protection) (iii) Accurcy class 5P 15 for protection core and 0.5 for metering core . (iv) VA Burden - 15VA for protection core and 10VA for metering core. (v) Short time - 18.4 KA for 1 second f)Self powered microprocessor controlled numeric relay comprising of three over current , one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxliary supply. g) Trip circuit supervision relay h) Master trip relay . (iii) Bus coupler vacuum circuit breaker 630A, HT, 11KV three phase,AC supply , 350MVA , 18.3 breaking capacity, short circuit rating 1 second, complete without any protection and metering - 02 No
Note : Both the buscoupler should be electrical and mechanical interlocked so as to avoid turning on of both VCBs simultaneously.Bus coupler to be provided with Trunking chamber and meet out existing panel specification. VCB PANEL SHOULD COMPRISE OF THE FOLLOWING FEATURES :- (a) Push buttons for accepting faults and reset. (b) LED indicating lamps for (duly control wired up) (i) Auto strip (ii) Spring charge (iii) Fault Alarm (iv) Trip Circuit Healthy (v) Trip circuit Unhealthy (vi) Breaker ON (vii) Breaker OFF c) RS 485 communication d) Motor operated spring stored energy trip for closing and opening of the breaker. e) Manual charging / operating arrangement. f) Fuses for metering and protection system g) One No. internal bus earthing with flat GI strip of size 50x 6mm h) one No. of space heater with thermostat i) One No. of inside lamp with switch ( 40W 230V) j) One No. of plug point with switch( 5A, 230V) k) Copper bus bar common for out going feeders with PVC sleeves
l) Complete control panel wiring with copper wire of size not less than 2.5 sqmm m) Civil design for foundation should be done all as per instructions manual of manufacturer. Note:- (a) The VCB shall be tested for High Voltage test, Primary Injection test & Secondary Injection test individualy at site after erection before commissioning and the same is deemed to be to included in the quoted rate. (b) VCB shall be drawout type and their should be provision of extendable. (c) Whole scheme shall be as per schematic line diagram arranged by the contractor from manufracture and shall be approved by the GE before execution. (d) Unit rate shall included the cost of danger notice baord, 11KV grade 25 cm CRCA ISI Marked, 11 KV grade, chequred type rubber mat 1 meter width and length equvalent to the width of the panel, Two sets of operating and maintenence manual, spares list, periodical mainenance chart / manual, lay out of panel / wiring shall be included in the rate quoted, (e) Cost of any civil work required to install the panels shall be deemed to be included in the rate of panel
Supply, Installation, testing and commissioning of 3 phase 50 Hz, Dry Type, Cast resin distribution transformer of ratings 750 kVA(Bidirectional the same shall be used as step down and step up as per requirement), 11/0.433 kV , indoor type ,Natural Air Cooled (ANAN) , conforming IS: 11171/1985 IS: 2026 Part ( I TO IV), and IEC726/1982.The transformer shall be suitably design to work satisfactorily under the tropical conditions of SRINAGAR .The windings of the transformers shall be connected to Delta on the primary side and star (Y) on the secondary side. The neutral of the LT winding shall be brought out to a separate terminal. The vector group shall be Dyn-11.The transformer should be provided with winding tapped on HV side with Number of tap positions: 7 nos and. Voltage variations : (+) 5 percent to (-) 10 percent in steps of 2.5 % for variation of HV Voltage to be changed by means of hand operated "OFF LOAD" tap changing gear switch externally operated with mechanical locking and a position indicator, the winding temperature rise over an ambient temperature of 50°C shall not exceed 90°C when measured by resistance method. i.e. Max. Temperature of the winding shall not exceeds 140°C and losses of transformer as per ECBC norms, Arcing horns for HT bushings for indoor type transformer. The transformer shall be supplied with standard accessories and comprising of following specification as under:- (a)Core: The core shall be of high grade cold rolled grain oriented (C.R.G.O) annealed silicon steel lamination confirming IS: 1271/1958 secured properly using frames, clamps and bolts. (b)Winding: HV & LV winding shall be done using High conductivity Electrolytic copper with insulation “F” class grade.
(c )Enclosure: Enclosure shall be rectangular and shall be built of electrically welded MS sheet wire mesh or perforated sheet for ventilation and comply with IP 43 protection as per IS: 2147/IEC 529. (d)Lifting lugs -04 nos for vertical lifting and pulling lugs -04 nos for horizontal pulling .(e) Bidirectional mild steel rollers 150 mm. diameter and 75mm. width -04 nos .(f)H. V. & L. V. BUSHING : Porcelain/ Epoxy HV and LV Bushings of appropriate voltage and current ratings shall be mounted in HV and LV cable box. The high voltage bushings (3nos.) shall be provided with R-Y-B colour coding marking & shall conform to IS 3347.Brass rods of suitable. dia.-03 nos for HV Bushing terminal and Tinned copper rods of suitable dia 04 nos for LV Bushings terminals/extension for cable lug connections, with necessary nuts, check nuts and plain thick tinned washers.(g)Terminal marking plates and rating plates.: Terminals shall be provided with terminal marking plates. The transformer shall provide with riveted rating plate. The entries of the rating plate shall be indelibly marked (for example by etching, engraving or stamping).(h)Transformer should be provided with Platform mounting channel of suitable size (With holes suitable for axle of roller) -2 Nos.(j)Painting:- The surface of the enclosure shall be properly pre-treated /phosphated in a seven enclosure process and shall be applied with a powder coating of 40 microns thickness of suitable colour code as per directions.(k) Four earth terminals per transformer, each suitable for earth conductors of size 32 x 6 mm GI strip for earthing of the body and neutral of the transformers. (l) Winding temperature indicator (WTI) -01 Nos.(m)The HV and LV side cable box with gland shall be provided.(n) Any civil work including foundation if any shall be as per OEM recommendation and the same shall be included in the cost of item.
Supply, Installation, testing and commissioning of 3 phase 50 Hz, Dry Type, Cast resin distribution transformer of ratings 750 kVA, 11/0.433 kV , indoor type ,Natural Air Cooled (ANAN) , conforming IS: 11171/1985 IS: 2026 Part ( I TO IV), and IEC726/1982.The transformer shall be suitably design to work satisfactorily under the tropical conditions of SRINAGAR .The windings of the transformers shall be connected to Delta on the primary side and star (Y) on the secondary side. The neutral of the LT winding shall be brought out to a separate terminal. The vector group shall be Dyn-11.The transformer should be provided with winding tapped on HV side with Number of tap positions: 7 nos and . Voltage variations : (+) 5 percent to (-) 10 percent in steps of 2.5 % for variation of HV Voltage to be changed by means of hand operated "OFF LOAD" tap changing gear switch externally operated with mechanical locking and a position indicator, the winding temperature rise over an ambient temperature of 50°C shall not exceed 90°C when measured by resistance method. i.e. Max. Temperature of the winding shall not exceeds 140°C and losses of transformer as per ECBC norms, Arcing horns for HT bushings for indoor type transformer. The transformer shall be supplied with standard accessories and comprising of following specification as under:- (a)Core: The core shall be of high grade cold rolled grain oriented (C.R.G.O) annealed silicon steel lamination confirming IS: 1271/1958 secured properly using frames, clamps and bolts. (b)Winding: HV & LV winding shall be done using High conductivity Electrolytic copper with insulation “F” class grade.
(c )Enclosure: Enclosure shall be rectangular and shall be built of electrically welded MS sheet wire mesh or perforated sheet for ventilation and comply with IP 43 protection as per IS: 2147/IEC 529. (d)Lifting lugs -04 nos for vertical lifting and pulling lugs -04 nos for horizontal pulling .(e) Bidirectional mild steel rollers 150 mm. diameter and 75mm. width -04 nos .(f)H. V. & L. V. BUSHING : Porcelain/ Epoxy HV and LV Bushings of appropriate voltage and current ratings shall be mounted in HV and LV cable box. The high voltage bushings (3nos.) shall be provided with R-Y-B colour coding marking & shall conform to IS 3347.Brass rods of suitable. dia.-03 nos for HV Bushing terminal and Tinned copper rods of suitable dia 04 nos for LV Bushings terminals/extension for cable lug connections, with necessary nuts, check nuts and plain thick tinned washers.(g)Terminal marking plates and rating plates.: Terminals shall be provided with terminal marking plates. The transformer shall provide with riveted rating plate. The entries of the rating plate shall be indelibly marked (for example by etching, engraving or stamping).(h)Transformer should be provided with Platform mounting channel of suitable size (With holes suitable for axle of roller) -2 Nos.(j)Painting:- The surface of the enclosure shall be properly pre-treated /phosphated in a seven enclosure process and shall be applied with a powder coating of 40 microns thickness of suitable colour code as per directions.(k) Four earth terminals per transformer, each suitable for earth conductors of size 32 x 6 mm GI strip for earthing of the body and neutral of the transformers. (l) Winding temperature indicator (WTI) -01 Nos.(m)The HV and LV side cable box with gland shall be provided.(n) Any civil work including foundation if any shall be as per OEM recommendation and the same shall be included in the cost of item.
Supply, installation, testing and commissioning of indoor type oil cooled isolation transformer 750 KVA,IS 2026, three phase, metalic body, unbalanced type copper wound with standard fittings and accessories, input voltage of 415 volt +/- 5% output voltage 415 volt+/- 5% , IP-42 , vector group Dyn-11, of frequency 50Hz and with following description including first fill of transformer oil of oil IS 335 ISI marked:- (a) Method of cooling - Oil cooled. (b) Ratio - 1: 1 (c ) Insulation class -Class -E (d) Winding Temperature - Less than 55* C (e) Full load lossess- Less than 5% (f) No load lossess - Less than 0.5% (g) Mounting - On wheel detachable type (h) Potential difference between Earth to Neutral voltage - Less than 01 volt. Note :- a)In addtion to the above all standard fittings to be provided as per ISI norms. (b) PCC foundation concrete and coping shall be as per OEM recommendation.
S & F Voltage stabilizer servo controlled suitable for automatic operation, three phase, naturally of cooled indoor type & designed for input variation between 340 V to 480 V with output voltage stabilized at 415 V with accuracy ±2.5% and speed of correction 8 volt/second for single phase and 20volt/second for phase to phase of capacity 750 KVA conforming to IS. 9815 (Part-II), with first filling of oil and with necessary by pass arrangement and provision of Digital display voltmeter and amp meter of suitable rating. All the three phases will be corrected independently, Suitable for Balanced or 100% Unbalanced Supply. The stabilizer should have protection against short circuit, over load, high/low voltage cut off and phase sequencer complete all as specified with following parameters as under : 1. Input Voltage Range: 340-480 V 2. Output Voltage:- 415V + /- 1% 3. Frequency Range:- 50 Hz + /- 5% 4. Output Current:- not less than 1050 amps 5. Wave Form Distortion:- Nil 6. Response Time:- Less than 10ms 7. No Load Loss:- Less than 0.4% and Full load losses :-Less than 2.5% 8.Efficiency:-98-99% 9. Duty Cycle: Continuous 24x7 10. Cooling: Oil Cooled Natural
11. Degree of Protection: IP-30 Types. 12.Ambient temperature operation from –20° C to 50° C 13 .Copper wound in CRGO laminations variable Auto transformers one for each phase. 14. Heavy duty AC synchronous motor for individual phase correction. 15. Copper wound in CRGO laminations buck/boost transformer for each phase.16. Control circuits for individual phase control. In addition to above the stabilizer should be provided with Two Nos. Earthing terminals, Cable end boxes for incoming and outgoing side for terminating cables, Oil level indicator, filling & drain valve, lifting lugs, wheels, provision for Auto/Manual control from the front panel complete all as specified and as directed by Engr-in-charge.”
Supply,testing and commissioning indoor L.T.Panel board factory fabricated indoor cubicle type totally enclosed made out of 2.00 mm thick sheet metal enclosure with angle iron frame of suitable size, CPRI approved, IP-42 for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, removable bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands of suitable size for cable entry and exit complete with necessary internal wiring with stranded copper conductor FRLS PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar rating 1750 Amp for 3 phase & half of neutral mounted on epoxy insulator-01 Set including connecting the following.
Supply,testing and commissioning indoor L.T.Panel board factory fabricated indoor cubicle type totally enclosed made out of 2.00 mm thick sheet metal enclosure with angle iron frame of suitable size, CPRI approved, IP-42 for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, removable bottom gland plate bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands of suitable size for cable entry and exit complete with necessary internal wiring with stranded copper conductor FRLS PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar rating 1750 Amp for 3 phase & half of neutral mounted on epoxy insulator-01 Set including connecting the following. (For PS1 and PS2))
Supply,testing and commissioning indoor weather & dust vermin proof L.T.Panel board factory fabricated indoor cubicle type totally enclosed made out of 2.00 mm thick sheet metal enclosure with angle iron frame of suitable size, CPRI approved, IP-42 for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, removable bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor FRLS PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar rating 1750Amp for 3 phase & half of neutral mounted on epoxy insulator-01 Set including connecting the following. (PS1 and PS2)
M&L for boring of holes under road, pavement, hard standing not less than 2mtr by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of HT Cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed.
Supply and fixing cable route indicator, consisting of 200mm dia 6mm thick cast iron to be painted with brown colour with inscription casting as HT Cable 11000 Volts grade,and fixed with and including hot dipped GI angle of size 40mm x 40mm x 6mm, 0.60m long, GI bolts, nuts embedded in ground in route of cable with and including PCC 1:3:6 type C2 of size 200mm x 200mm x 300mm all as directed.
Supply and fixing rubber mat of size 1m x 2m x 19mm for 11 KV sub station complete all as specified and directed.
Supply and fix LED street light 100/105/110 W IP 65, incl Street light Brackets & fixing arrangements as per site requirement complete all as specified and directed.,
Supply and fix MS box made out of 2 mm thick MS sheet of size (15 cmx10cmx8cm) incl 2 nos bus bar of suitable size and one MCB 6 Amp SPN and fixed on pole with clamps, bolts,nuts complete with two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Total amount of Sch 'A' Part-V (Section-I) (EXTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' part-V (Section-II)( EXTERNAL WATER SYPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
M&L for Cutting of the existing GI pipe line 80 mm dia and inserting "T" size 80x80x25mm including connecting piece of 40/25 mm including necessary fittings, excavation/ earth work complete all as specified and directed.
Construction of valve chamber of size 600x600x600mm internal size suitable for valves with PCC 1:4:8 type D2 for foundation and brick wall in cement mortar 1:4 PCC 1:2:4 type B1 for coping rendering in CM (1:4) 15mm thick including provn of mild steel sheet cover 3.15mm thick on 40x40x6mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work all as spfd and as directed.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated complete all as specified and directed.
Total amount of Sch 'A' Part-VI (Section-I) (PLUMBING WORK)
Total amount of Sch 'A' part-VI (Section-II) ( PLUMBING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F 110 mm PVC (SWR) bend complete all as specified and directed.
S&F 75 mm PVC (SWR) bend complete all as specified and directed.
Total amount of Sch 'A' Part-VII (ROAD/PATH/CULVERT WORK)
Total amount of Sch 'A' Part-VIII (LIGHTENING PROTECTION WORK)
Total amount of Sch 'A' Part-IX ( BOUNDARY WALL, FENCING AND GATE WORK)
Total amount of Sch 'A' Part-X (Section-I) (AREA DRAINAGE WORK)
Total amount of Sch 'A' part-X (Section-II) ( AREA DRAINAGE WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
M&L for boring of holes under/along runway and taxi tracks by trenchless technology using ultrasound technique using necessary machineries including laying of HDPE pipe fo dia upto 350mm of PE 60, PN 6.3 grade at 2.5 M deep below including suitable cap at ends and inserting 4mm GI wire, complete all as specified and directed.
Total amount of Sch 'A' Part-XI (Section-I) (SEWAGE DISPOSAL WORK)
Total amount of Sch 'A' part-XI (Section-II) ( SEWAGE DISPOSAL WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F CI manhole covers 600mm dia. Complete all as specified and directed.
S & F of LLDPE tank for 10 user including vent shaft and other necessary fixing arrangement complete all as specified and directed.
Total amount of Sch 'A' Part-XII (Section-I) (WINTER SUMMER APPLAINCES WORK)
Total amount of Sch 'A' part-XII (Section-II) (WINTER SUMMER APPLAINCES WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply,installation,commissioning and testing high wall with cordless remote with inbuilt Heating and Cooling arrangement split type air conditioner of capacity 1.5 TR type inverter split suitable for non CFC refrigirant gas incl material and labour for the following works involved for smooth functioning & installation of outdoor/indoor units for split type AC all as directed by Engr-in-charge Make- O-general/Hitachi/blue star or equivalent approved by AO (a) Fixing the heating & cooling unit with grounting nuts, cutting groove to wall for gas pipe and water drainage pipe complete. (b) S&F cutting, bent to shape copper pipe of appropriate size from outdoor unit to indoor unit by cutting holes to wall incl brazing the copper pipe, fixing union all as required at site. © S&F pvc pipe 20 mm dia transparent flexible heavy duty for drainage pipe (approx-3.0 M). (d) Insulation of both the copper pipe with insulating material and covering the complete pipes with pvc casing & caping of size 75x75mm for mechanical protection of copper pipe complete.
(e) Charging of correct quantity non CFC refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete on load up to saitisfaction of EIC. (f) S&F MS bracket factory made, fixed on wall through fastener of appropriate size and guage for installation of out door unit (condensing unit) complete all as direced. (g) M&L for provision of shed for outdoor unit made of MS sheet 2.0 mm thick and MS angle 40x40x5mm complete. Note - (i) All other connected civil works and other miscellaneous works required for installation of split AC & proper functioning including making good all damaged/altered wall surfaces complete all as specified and directed.
Supply,installation,commissioning and testing high wall with cordless remote with inbuilt Heating and Cooling arrangement split type air conditioner of capacity 2.0 TR type inverter split suitable for non CFC refrigirant gas incl material and labour for the following works involved for smooth functioning & installation of outdoor/indoor units for split type AC all as directed by Engr-in-charge Make-O-general/Hitachi/blue star or equivalent approved by AO (a) Fixing the heating & cooling unit with grounting nuts, cutting groove to wall for gas pipe and water drainage pipe complete. (b) S&F cutting, bent to shape copper pipe of appropriate size from outdoor unit to indoor unit by cutting holes to wall incl brazing the copper pipe, fixing union all as required at site. (c) S&F pvc pipe 20 mm dia transparent flexible heavy duty for drainage pipe (approx-3.0 M). (d) Insulation of both the copper pipe with insulating material and covering the complete pipes with pvc casing & caping of size 75x75mm for mechanical protection of copper pipe complete.
(e) Charging of correct quantity non CFC refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete on load up to saitisfaction of EIC. (f) S&F MS bracket factory made, fixed on wall through fastener of appropriate size and guage for installation of out door unit (condensing unit) complete all as direced. (g) M&L for provision of shed for outdoor unit made of MS sheet 2.0 mm thick and MS angle 40x40x5mm complete. Note - (i) All other connected civil works and other miscellaneous works required for installation of split AC & proper functioning including making good all damaged/altered wall surfaces complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
Supply and fix street light panel with digital 24 Hr timer with 63 Amp 4pole MCCB and contactor of 63A rating.
Total amount of Sch 'A' Part-XIII (SECTION-I) (ADDITION ALTRATION TO SERVER WORK)
Total amount of Sch 'A' part-XIII (SECTION-II) (ADDITION ALTRATION TO SERVER WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F aluminium composite panels, 5mm thick as in doors, of any colour, shape, size and design fixed on aluminium frame work including all necessary fittings and fixtures and necessary taping, complete all as per manufactures instructions, complete all as specified.
Total amount of Sch 'A' part-XIV (SPECIAL ITEM OF WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F access flooring with tiles of size of 600x600mm finished high pressure laminate finish of using USF 100, grade panel with edge support rigid grid (ESRG) system, able to take concentrated load of 450 Kg, ultimate concentrated load of 1125 Kg, Uniformly distributed load of 2025 Kg/Sqm and steel pedestal axial load of 22 KN incl understructure for 300mm finished height, complete all as specified.
Supply only panel viewing area 500 X 500mm, complete all as spcified.
Supply only single directional air flow grill 55% perforation area with volume control damper, complete all as specified.
Supply only grommets wire manager series 75 PVC, complete all as specified.
Supply only panel lifter double cup, complete all as specified.
Total amount of Sch 'A' Part-XV (EARTH WORK AND SITE CLEARANCE WORK)
Total amount of schedule 'A' Part-XVI schedule of credit of Rs 2775.00 for retrieved material on page 100 of tender documents in PDF format which will be deducted offline during acceptance of tender.
United Sales Corporation
M/S Rather and Sons
ALCO ENGINEERSPVT LTD
SHAH AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .