Karnataka Power Corporation Limited
PRAKASH M
Rectification of Simplex make(4100U) Fire Alarm control panel of Unit-1 and 2 at BTPS
KPCL/2024-25/PS/WORK_INDENT2575
KPCL/2024-25/PS/WORK_INDENT2575
Open
Power stations
Two Tender Document System(Two Cover)
KPCL Executive Engineer SAFETY Office BTPS Bellary
4 documents required · 0 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
The bidder should have executed the similar nature of work such as Rectification and commissioning of Fire Detection and Alarm system and Fire Alarm control Panel, OR Erection, Testing AND commissioning of Fire Detection and Alarm system and Fire Alarm control Panel OR The bidder should have executed complete Plant maintenance works of any Thermal power plant in 210MW .The bidder should have satisfactorily executed the above said works, as a Prime contractor for an amount of not less than 15.81 Lakhs in any of the preceding FIVE years.Work done value of previous years shall be given weightage of 10% per year to bring them to the present price level of the financial year, in which tenders are invited.The intending bidder shall submit the work order and relevant work done certificate as a documentary proof issued by the competent authority. On demand original shall be produced for verification.
The agency should have PF, GST,ESI, PAN, Insurance, Valid Labor license with statutory department and shall upload original copy of above registration certificate in e-portal
The Bidder should have achieved in at least two financial years an average annual financial turnover of 31.61 Lakhs in any two of the preceding FIVE financial years. The bidder shall furnish the Profit and Loss statement duly certified by chartered accountant as a documentary proof. On demand original shall be produced for verification. Financial turnover of previous years shall be given weightage of 10% per year to bring them to present price level of the financial year in which tenders are invited.
The declaration by the bidder that None of his contracts have been terminated OR foreclosed on account of his default in KPCL or elsewhere during last five years
The bidder should be Original Equipment Manufacturer / Original Equipment Supplier/Authorised service/Authorised dealer of Simplex make Fire Alarm and detection system or M/s. Tyco(M/s. Johnson Controls International ) . If the bidder is an authorized dealer/authorized service, bidder should mandatorily submit duly signed authorization certificate for participating in the tender.
₹800
₹63,240
11 Feb 2025
11 Feb 2025
27 Feb 2025
18 Feb 2025
20 Feb 2025
Rectification of Simplex make(4100U) Fire Alarm control panel of Unit-1 and 2 at BTPS
Providing, installation, testing & commissioning of Simplex Network Card with wired media Module, 4100-6014 / 4100-6058, make:simplex
Providing, installation, testing & commissioning of Simplex TRUESITE GUI Sofware with PC, License key / Dongle Key, PCI Network Card with wired media Module. Make: Simplex
Providing, installation, testing & commissioning of Simplex Addressable FAS panel 4100ES 2x40 character, 3 Bay Panel, Including 1no CPU, 1no EX-PS, 1no Network Card, 10nos Loop Cards, required power s...
Providing, installation, testing & commissioning of Simplex SPS card, 4100-5401. Make -Simplex
Providing, installation, testing & commissioning of Simplex CPU card, 4100-7158. Make-Simplex
Providing, installation, testing & commissioning of Simplex RUI Mother board. Make-simplex
Providing, installation, testing & commissioning of ES-PS Master Controller without
Display - English, CPU Card, ES Power
Providing (120 V to 240 V 50/60 Hz, 24 V Aux. Relay, 24 V Aux.
Power Tap/Simpl...
Providing, installation, testing & commissioning of Xps Card. Make-simplex
Providing, installation, testing & commissioning of RS232 Card. Make-simplex
Rectification of Unit 1 Loop Cards, establishing communication with local ID net Devices. Proper Communication of field devices with loop cards should be ensured in presence of site engineer in charge...
Rectification of Unit 2 Loop Cards and establishing communication with local ID net Devices. Proper Communication of field devices with loop cards should be ensured in presence of site engineer in cha...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
FDA 10.02-FINAL UPLOADED_Rev.pdf
Tender Document • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .