Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC 736 PARAGDAS MANDIR NIRMOCHAN GHAT AYODHYA 224123 | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.0 L+₹27,940.40 (4.14%)Rejected-Finance 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹7.9 L+₹1.1 L (16.8%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹8.8 L+₹2.1 L (30.9%)Rejected-Finance | L4 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | His And Her Enterprises L3 | disha construction L1 | FUTURE Inc. L2 | D K Engineers and contractors L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | S&F in repair of 15mm bore GI pipe medium grade with all fittings and fixtures complete fixed to wall/ceiling or laid in floor /trenches etc. complete all as specified and directed by Engr-in-charge.
Note - Excavation & earth work shall be measured and paid separately) | 200 | RM | 160 ₹32,000 | 88 ₹17,600 | 80 ₹16,000 Lowest | 175 ₹35,000 |
| 2.00 | All as per item No. 1.00 here-in-before but 20 mm bore. | 400 | RM | 180 ₹72,000 | 100 ₹40,000 | 88 ₹35,200 Lowest | 195 ₹78,000 |
| 3.00 | All as per item No. 1.00 here-in-before but 25 mm bore. | 420 | RM | 230 ₹96,600 | 120 ₹50,400 | 98 ₹41,160 Lowest | 225 ₹94,500 |
| 4.00 | All as per item No. 1.00 here-in-before but 50 mm bore. | 200 | RM | 380 ₹76,000 | 275 ₹55,000 | 245 ₹49,000 Lowest | 401 ₹80,200 |
| 5.00 | All as per item No. 1.00 here-in-before but 80 mm bore. | 50 | RM | 580 ₹29,000 | 502 ₹25,100 | 405 ₹20,250 Lowest | 751 ₹37,550 |
| 6.00 | Refixing old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) including cleaning of pipes of 20mm bore complete all as specified and directed by Engr-in-charge. | 20 | RM | 50 ₹1,000 | 43 ₹860 | 38 ₹760 Lowest | 51 ₹1,020 |
| 7.00 | All as per item No. 6.00 here-in-before but 25 mm bore. | 30 | RM | 55 ₹1,650 | 47 ₹1,410 | 40 ₹1,200 Lowest | 51 ₹1,530 |
| 8.00 | S&F gun metal globe or gate valve 'ISI marked' with iron wheel head screwed both end for iron pipe all as per latest IS specifications of 15mm bore complete all as specified and directed by Engr-in-charge. | 15 | Each | 600 ₹9,000 Lowest | 695 ₹10,425 | 658 ₹9,870 | 951 ₹14,265 |
| 9.00 | All as per item no. 8.00 here-in-before but 20 mm bore. | 25 | Each | 700 ₹17,500 Lowest | 818 ₹20,450 | 715 ₹17,875 | 1,151 ₹28,775 |
| 10.00 | All as per item no. 8.00 here-in-before but 25 mm bore. | 35 | Each | 800 ₹28,000 Lowest | 1,156 ₹40,460 | 945 ₹33,075 | 1,201 ₹42,035 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
15 Aug 2025, 6:00 pmClosed
AGE (I) Ayodhya
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
REPAIR/MAINT AND REPLACEMENT OF OLD UNSERVICEABLE GI/DI WATER PIPE LINES,GATE VALVES AND CONNECTING WORKS AT AYODHYA CANTT
2025_MES_721254_1
8400/098/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Ayodhya Cantt
₹20,000
Yes
11 Dec 2025
18 Jul 2025
18 Aug 2025
18 Jul 2025
15 Aug 2025
1 Aug 2025
Amount
S&F in repair of 15mm bore GI pipe medium grade with all fittings and fixtures complete fixed to wall/ceiling or laid in floor /trenches etc. complete all as specified and directed by Engr-in-charge. Note - Excavation & earth work shall be measured and paid separately)
All as per item No. 1.00 here-in-before but 20 mm bore.
All as per item No. 1.00 here-in-before but 25 mm bore.
All as per item No. 1.00 here-in-before but 50 mm bore.
All as per item No. 1.00 here-in-before but 80 mm bore.
Refixing old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) including cleaning of pipes of 20mm bore complete all as specified and directed by Engr-in-charge.
All as per item No. 6.00 here-in-before but 25 mm bore.
S&F gun metal globe or gate valve 'ISI marked' with iron wheel head screwed both end for iron pipe all as per latest IS specifications of 15mm bore complete all as specified and directed by Engr-in-charge.
All as per item no. 8.00 here-in-before but 20 mm bore.
All as per item no. 8.00 here-in-before but 25 mm bore.
All as per item no. 8.00 here-in-before but 50 mm bore.
Attending complaint for rectification of leakage of 80mm bore GI Pipe line including excavation, returning and filling, screwing and threading etc including fittings like unions, sockets, bends, elbows, tees, nipples etc as per site requirement and complaint shall be rectified within 24 Hrs from date of complaint complete all as specified and directed by Engr-in-charge.
All as per item No. 12.00 here-in-before but 50 mm bore.
All as per item No. 12.00 here-in-before but 25 mm bore.
All as per item No. 12.00 here-in-before but 20 mm bore.
All as per item No. 12.00 here-in-before but 15 mm bore.
M&L for replacement of old rusted flat iron clamp of size 370 mm length 80 mm width and 6 mm thickness along with 25 / 50 mm hole in centre of the clamp and fixing of 25 / 50 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the desired curve on flat iron suitable for fixing on 150 mm pipe mains complete all as specified and directed by Engr-in-charge.
M&L for replacement of old rusted flat iron clamp of size 370 mm length 65 mm width and 6 mm thickness along with 20 / 15 mm hole in centre of the clamp and fixing of 20 / 15 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the curve on flat iron suitable for fixing on 150 mm pipe mains complete all as specified and directed by Engr-in-charge.
M&L for replacement of old rusted flat iron clamp of size 270 mm length 80 mm width and 6 mm thickness along with 25 / 50 mm hole in centre of the clamp and fixing of 25 / 50 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the curve on flat iron suitable for fixing on 100 mm pipe water mains complete all as specified and directed by Engr-in-charge.
M&L for replacement of old rusted flat iron clamp of size 270 mm length 65 mm width and 6 mm thickness along with 20 / 15 mm hole in centre of the clamp and fixing of 20 / 15 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the curve on flat iron suitable for fixing on 100 mm pipe water mains complete all as specified and directed by Engr-in-charge.
Attending complaint for rectification of leakage in 150 mm bore DI pipe line with push on joints complete by rubber gasket or flange spigot and socket fitting, any bend or tee including necessary nut bolts & washers etc including excavation for any lenght of pipe by using labour as well as returning,filling complete all as specified and direcrted by Engr-in-charge.
All as per item No. 21.00 here-in-before but 100 mm bore.
Attending complaint for rectification of leakage in 150 mm bore DI pipe line with flanged joints fixed to pillar of RCC overhead reservoir upto 21 meters height or below ground level complete by rubber or fibre board gasket, blank flange with screwing or threading on lathe machine, desired chemicals for leakage inside floor of overhead tanks where pipes are attached including necessary nut bolts & washers etc including excavation by using labour as well as returning,filling complete all as specified and direcrted by Engr-in-charge.
All as per item No. 23.00 here-in-before but 100 mm bore.
S&F in repair Union 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 25 above but 20 mm bore
All as per item ser No 25 above but 25 mm bore
All as per item ser No 25 above but 50 mm bore
S&F in repair Socket 'ISI marked' for iron pipe all as per latest IS specifications of sixe 15 mm bore.
All as per item ser No 26 above but 20 mm bore
All as per item ser No 26 above but 25 mm bore
All as per item ser No 26 above but 50 mm bore
S&F in repair Nipple of length 6'' 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 27 above but 20 mm bore
All as per item ser No 27 above but 25 mm bore
All as per item ser No 27 above but 50 mm bore
S&F in repair Nipple of length 4'' 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 28 above but 20 mm bore
All as per item ser No 28 above but 25 mm bore
All as per item ser No 28 above but 50 mm bore
S&F in repair Elbow 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 29 above but 20 mm bore
All as per item ser No 29 above but 25 mm bore
All as per item ser No 29 above but 50 mm bore
S&F in repair Long 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 30 above but 20 mm bore
All as per item ser No 30 above but 25 mm bore
All as per item ser No 30 above but 50 mm bore
S&F in repair Plug 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 31 above but 20 mm bore
All as per item ser No 31 above but 25 mm bore
All as per item ser No 31 above but 50 mm bore
S&F in repair Reducer of size 15*20mm 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 32 above but 20*25 mm bore
S&F in repair TEE of size 25*25*20mm 'ISI marked' for iron pipe all as per latest IS specifications of size 15 mm bore.
All as per item ser No 33 above but 25*25*25 mm bore
Taking out GI pipe 15/20/25 mm dia from wall/floor internally cleaning the pipe with pressure jet. refixing the pipe in same position complete all as specified and directed Note : Excavation or Earth work if involved will be measured separately.
Taking out GI pipe 50/80 mm dia from wall/floor internally cleaning the pipe with pressure jet. refixing the pipe in same position complete all as specified and directed Note : Excavation or Earth work if involved will be measured separately.
M&L for rubber gasket joints for spigot and socket pipes and fittings of size 150 mm dia complete all as specified and directed by Engr-in-charge.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for laying / taking out water supply pipe line in soft/loose soil, taking out excavated material,forming bottom etc complete all as specified and directed Engr-in-charge.
Returning filling in including,spreading ,levelling watering and well ramming in layer in n.exc 25 cm in soft/lose soil all as specified directed Engr-in-charge.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point as in soft/loose soil complete all as specified and directed Engr-in-charge.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 10 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 7.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
Repair and maintenance of defective Monoblock motor pump any make & model of capacity upto 2.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
M&L for applying two coats of synthetic enamel paint on distribution header of DI pipes & fittings including writing of location to be fed on each disribution point including sluice valves of various pump houses after scraping/ preparing of old surfaces complete all as specified and directed by Engr-in-charge.
M&L for making of Poster related to Water conservation with writing slogan on external surfaces of pump house boundary wall in suitable colour after preparation of old complete external boundry wall surface by taking down of old/ broken tiles,scraping, washing, rubbing down and stopping of distempered and painted and applying two coat of cement based paint on complete external surface of pump house boundary wall complete all as specified and directed by Engr-in-charge.[Note: - (i) Before applying cement paint, the complete external boundry wall surface shall be thoroughly wetted to control surface suction. (ii) Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used] complete all as specified and directed by Engr-in-charge.
FUTURE Inc. (BID ID -3383065)
His And Her Enterprises (BID ID -3380407)
D K Engineers and contractors (BID ID -3385616)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .