Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-Finance | ₹18.3 L | L1 | Accepted-Finance 1st lowest |
| 2 | L2₹18.3 LRejected-Finance | ₹18.3 L | L2 | Rejected-Finance 2nd lowest |
| 3 | L3₹18.3 LRejected-Finance | ₹18.3 L | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹45,761
Closing Date
17 Jan 2026, 12:30 pmClosed
Executive Engineer, PWDte
Bankura
Electrical Installation works and SITC of AC System for Modification of meeting hall in existing building at Krishi Bhawan, Bankura.
2026_WBPWD_982423_1
WBPWDTE/EE/BED/NIQ_47/Q of 2025-26
Open Tender
ELECTRICAL WORKS ORG
60 days
Krishi Bhawan
Please refer Tender documents.
3 documents required · 3 mandatory
₹45,761
11 Feb 2026
2 Jan 2026
19 Jan 2026
2 Jan 2026
17 Jan 2026
2 Jan 2026
PART A(I) : INTERNAL EI WORK S & F of 3 nos.415V, 200A rating Porceline Kit-Kat Fuse unit & 1 no. Brass Neutral connector on hard rubber/porceline insulator on 12mm thick hylam sheet of size 500mm x 350mm fixed on flat iron frame on wall.
Distn. Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 19mm bore, 3mm thick polythene pipe complete with all accessories embedded in wall to light / Fan / Call bell point as per GS with with Modular type switch (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) following average run. 8 Mtr
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switch(Make- Legrand, Model- Myrius or equivalent model of Crabtree/ Equivalent make as per direction of E.I.C) as per GS. On Board
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works as stated below 19 mm dia 3 mm thick
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works as stated below 25mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. 3 x (1.5 sqmm) (for separate power plug) (Make:-Finolex/RR Kabel/Gloster/Mescab)
2x(2.5 sqmm)+1x(1.5 sqmm) (for computer board & power socket)
2x(4 sqmm)+1x (2.5 sqmm)
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [VTPN DB to 12W SPN DB]
2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC [VTPN DB to 16W SPNDB]
S & F solderless Copper socket by crimping of Copper wires. a)1.5 sq mm
b) 2.5 sq mm
c) 4 sq mm
d) 6 sq mm
e) 10 sq mm
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works incl. supply & fixing bakelite/perspex top cover by Brass screws as per GS. 175 x 100 x 65
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per direction of EIC. 6 Way ( Up to 160 A ) Make - L&T Enclosure (LTVD06MGN) or equivalent make of Legrand/ABB/Seimens as directed by EIC.
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand / Schneider/L&T/Siemens/ABB) as per direction of EIC] 125A
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way Crabtree Enclosure (DCDKSHODCW12) / Seimens Enclosure (8GB32102RC12) / ABB Enclosure (SCHM10) or equivalent model of Legrand] as per direction of EIC.
2+16 Way (Make:- Legrand Enclosure 607713 or equivalent make of Schneider/Cabtree/L&T/Siemens/ABB) as per direction of EIC.
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ L&T) as per direction of EIC. ] 40 A DP [for SPNDB]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/L&T/ ABB) as per direction of EIC. ] 6-32 SP
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical / SPNDB enclosure with IP-42/43 as per GS 4/6/8 Way (Vertical)
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection (Make-Legrand)(for 1ph UPS)
Supplying and fixing 63A DP Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc.(Make:- Havells/HPL/Standard/L&T). [for UPS Bypass]
Supply of 2/3/3.5/4 Core XLPE Insulated & Sheathed Armoured Copper Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: MESCAB/ Gloster/Polycab/ Havells/RR Kabel] 4 Core 70 Sq. mm [ From O/G TPN SFU to VTPN ] [ NS ]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. As per GS. From 70sqmm to 150sqmm
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support- 200x50x1.25mm (18SWG)
Supply& Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 200x50x1.25mm (18SWG)
Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 200x50x1.25mm (18SWG)
Supply & Fixing of perforated GI cable tray cross member with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 200x50x1.25mm (18SWG)
Supply & Fixing of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the reducer incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 200x50x1.25mm (18SWG)
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 Core 70 Sq. Mm
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 Module
Supplying & Fixing modular type socket /socket (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C), in exsisting Modular board incl. connections. 6 A 5-pin modular type 5 pin socket
6 A modular type switch
Supply & Fixing 240 V, 1 nos. 16A & 3 nos. 6 A, 3 pin Modular type plug socket with 1 nos. 16A & 3 nos. 6 A Modular type switch (Brand approvedby EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) & necy. Connections.
Supply & Fixing 240 V, 25 A, Modular type AC starter (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube Single Fittings (make- Philips, Cat No. TMC-502 P1xT-LED 22W or equivalent model of CG / Surya / Wipro/Havells) incl. 1 no. 18W Master LED Tube Cat No. 865 T8 (Pc)
S & F of Either 36W 600mm x 600mm (2x2) recess mounted LED light fittings with CRCA powder coated housing high efficency PMMA diffuser or 40W Round Recessed LED Downlight Luminaries suitable for False Ceilling complete with electronic driver after cutting false ceiling, Incl. connections. as per direction of EIC.(make- Crompton Pollux LCTLRP-30-FO-CDL/ or equivalent model of Philips/ Surya / Wipro/Havells).
Supply & Fixing of 28W LED Striplight suitable for False Ceilling application. The luminaire has efficacy of 100 lm/w, Incl. making connections with all necessary accessories as per direction of EIC.(make- Philips LED Sky Cove Strip 5M WW/NW/CW with driver or equivalent model of Crompton/ Surya / Wipro/Havells)
Fixing only single/twin LED batten light fitting suspended from the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as per GS.
Supply & fixing 450 mm sweep Air Circulatior fan(high speed) with metal body,canopy & blades( Make -Crompton TORPEDO (HS) or equivalent make of USHA/Bajaj/Havells/Orient as approve by E.I.C.) with necessary wooden board on wall with nuts, bolts, washer etc. as per direction of EIC.
Supply & fixing 300 mm Heavy Duty Exhaust fan (Make-Crompton Heavy Duty EXHD300-6-1 or equivalent make of USHA/Bajaj/Havells/Orient as approved by E.I.C] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust as per direction of E.I.C. 12"( 300mm ) Speed >= 900 RPM
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS (12")
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe.
Supplying & fixing earth bus bar of galvanized (HotDip) MS flat 25 mm x 6mm on wall having clearance of 6mm from wall including providing drilled holes on the bus bar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mmGalvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No.-4 SWG
No.-10 SWG
PART A(II):AIR CONDITIONING SYSTEM SITC of 1 Ph,240V, 50Hz, 1.9-2 TR Capacity Non inverter Split type A.C. machine( cooling Only),having features (i)Body of Indoor Unit made of Fire retardant material, (ii)minimum ISEER rating 3.88 (iii)Nominal Cooling capacity: 7.2KW or 6048kcal/Hr (iv) Input Power Consumption(Max): 2.5 KW (v)Minimum Air discharge rate:777 CFM, (vi) Refrigerant: R32 (vii) Compressor: Rotary compressor or as per OEM Standard (viii) Conderser & evaporator Coil: Should be made of copper or as per OEM Standard (ix) Noise level of IU: not more than 50 dB (x)Energy efficiency (min. ISEER-3.8) incl. Remote etc. to complete the installation including connection and Fixing of pipe & cable as per direction of EIC (Make :- Mitsubishi Electric MU-AGZ24VF or equivalent make of Daikin cat no. FTKL60U) / O-General/ Mitsubishi Heavy) including installation kit. N.B.:The AC machines are to be delivered at site free of cost.
Supply and fixing of HVAC grade copper pipe of following sizes for liquid and Gas line between ODU and IDU [make :Hitachi Ryoku/Nippon] 5/8"( Gas Line)
1/4" (Liquid Line)
Supply & fixing of Insulation properly wrapped with tape (Polyehylene Foam/ Nitryle Rubber Foam )of following thickness for Liquid & Gas Line.(Make- Armacell/K-Cell/Supreme) 5/8"( Gas Line) 9 mm thichness
1/4" (Liquid Line) 9 mm Thickness
Supply & Charging of R-32 Refrigerant.
Supply and fixing of 4 core 2.5sq.mm PVC insulated unsheathed copper flexible power cable for inter connection between IDU &ODU.(Make-Havels/Gloster/RR/Polycab)
Supply and fixing of 18mm dia PVC flexible pipe with nylon rainforced including jointing materials for drainage of water.
Charges for Cutting 20 inch wall for laying CU & Drain Pipe of Split Type 1.5 Ton / 2 Ton AC Machine.
PART A(III) :- SITC OF UPS SYSTEM Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 25mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. (Make:-Finolex/Gloster/Mescab) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
Supply, installation & Testing and Commissioning of 6 KVA, 240 Volt 1 phase INPUT and 1 phase OUTPUT UPS with SMF Battery bank for 1 hour backup, Having following Specification : IGBT based double conversion True Online UPS with built-in Isolation Transformer on the Inverter output, input and output EMI Filter, Redundant processor, Voltage Range Input -- 160V-300V AC, Frequency-46 to 54 Hz, Output--220V AC Phase to Phase (+/- 1%) on 100% load, Frequency-50 Hz +/- 0.5%, Output Power Factor: 0.9 or better, Efficiency >=92% on rated full load, DC Voltage- (as per manufacturer standard). Minimum VAH for 1 hour back up 10080 VAH; Battery make - Exide/Quanta , Including Battery Rack, Inter Connection of above Batteries with Suitable copper interlinks, Lugs etc. as required UPS General & Safety Standards: CEI EN 62040-1 ; EN 62040 - 2 : 2006; IEC 62040 - 3 Quality Certification: ISO 9001:2015; ISO 14001:2015; ISO 50001:2018: & ISO 45001: 2018 E-Waste Certification: EPR authorization from CPCB, Govt. of IndiaApproved Make: Numeric/APC/Emersion .
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.24 MB
2911.pdf
Additional Documents • 0.13 MB
BOQ_2396353.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid