Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.6 LAdmitted-Finance 209 SEWAK COLONY PATIALA PUNJAB | PATIALA | PUNJAB | 140401 | -15.60% | ₹12.6 L | L1 | Admitted-Finance |
Tender Value
₹15.0 L
EMD Value
₹29,950
Closing Date
1 May 2026, 3:00 pmClosed
EXECUTIVE ENGINEER
ELEC DIV PWD B AND R AMRITSAR
Providing battery backup based fully adaptive Vehicle Management System at Qadian Chungi, Tehsil Balata Distt Gurdaspur.
2026_CEPW_166950_1
6/2026-27, 24.04.2026
Open Tender
Electrical Works
180 days
BATALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
₹29,950
21 May 2026
24 Apr 2026
1 May 2026
24 Apr 2026
1 May 2026
24 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- | |||||
| 1.01 | CAT 6 LAN cable | - | Metre | - | - |
| 2DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- | |||||
| 2.01 | Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) | - | Metre | - | - |
| 3Supply, Installation ,testing & commissioning (SITC) of 4G Modem & SIM Card based Data Receiving & Sending Communication Devices working on Serial/I2C/ ModbusTCP/ EThernet TCP/IP protocols to be connected with separate City Signal Dashboard & Cloud Server System having following features and compatible for receving & sending data of Traffic Signal Controllers Systems. The device should allow for the following tasks: i. Register & Login for the Application to communicate with the existing Controller Systemsii. Location of Traffic Signal Systems iii. Sending Programs and Data to the Controller Stations iv. Live display of Power supply/Connectivity/Signal System UP or failure status v. Live Display of Traffic SIgnal Lights working with 4g time lag vi. App notification trigger to various Officials for Signal Failures indicators such as Power failure/ Signal Lights OFF (Optional) vii. Traffic Synchronisation Status, if any viii. Back-end admin panel for Maintenance Officials to pull out historical data of Signal Working fix. Fully customized Reporting module x. Switching ON/OFF Traffic SIgnals xi. Report for Special events at Traffic Signal System xi. Notification to concerned Officers and Contractors for failure of Traffic Signal Supply. Multiple alerts shall be configurable The device should be compatible with existing Traffic Signal Controllers complete in all respect as desired by the Engineer-in-charge:-at site | |||||
| 4SITC of Intelligent Motherboard Controller compatible with GSM Model and facility for connectivity to control room, Vehicle Actuation Cameras and ATCS mode for Vehicle Management with Live SKIP Timer and Camera Integration. The detailed specifications of the controller are as below: -HARDWARE Memory : NOVRAM with built in battery battery backup System clock: Calendar clock (RTC) with minimum 5 years Battery back-up clock Accuracy of Programming 1 sec per week Programming Facility Through external Engineering Application WITH BLUETOOTH operation FEATURES Number of signals Minimum 16 signals group should be programmable as either vehicular or Pedestrian groups. Additional Programmable dummy groups as desirable.Number of stage 16 stages Outputs The Motherboard should have Connector to connect further to the Sub Control Unit Vehicle Actuation: RS232/RS485/DI ports should be provided for communication with sensors and inbuilt software should be provided for Vehicle Actuation Facility so as to run the Traffic Signal in Vehicle Actuation Mode. The control system should have facility for working in Vehicle Actuation Mode. It should sense the inputs from various existing Traffic Sensors and adjust the Traffic Signals according to the intensity of traffic on all four/six roads of the Traffic Junction. The controller should be programmable so as to work in Vehicle Actuation with Cameras/Sensors etc at a particular time of the day/whole day/particular date etc. The controller should be integrated with Vehicle Detector cards, Vehicle Sensors cards etc. complete in all respects.Area Traffic control compatibility Controller should have live Ethernet/internet port for connecting to the area traffic control centre. Live port should be provided and testing / demo should be done /displayed before commissioning of controller . No hardware/software should be required to be provided up to controller at later stage when connection is required for area controller .ENVIRONMENTAL FEATURES Operating voltage:24VDC Temperature 00 C to 700 C Relative Humidity Max 95%The controller shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement.complete in all respect as desired by the Engineer-in-charge:-at site | |||||
| 5SITC of Traffic Light sub control unit with facility of Output Isolation Through solid state devices with zero cross output solid state switching isolated from control circuit by optical isolation in male female plug type single module. The solid state device should not be used for switching ON/OFF of more than 2 Nos. LED Lamps including shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement. The Sub Control unit shall be provided with Overload/over voltage protection and modular plug-in type system shall be provided for easy maintenance. The Unit shall also be provided with Indicators for Operator use complete in all respects with continuous input voltage current control & overload complete in all respect as desired by the Engineer-in-charge:-at site | |||||
| 6LED SIGNAL HEAD ASSEMBLY:- SITC of IP-65 Approved One Aspect signal Head LED Light Assembly of 300mm dia fabricated from polycarbonate materials die moulded Complete in all respects of nominal size 380 X 350mm complete in all respect with LED type traffic signals glasses. The visor shall be fabricated from UV Stabilised HDPE Materials of length min 254 mm depth and tilted 50 along the geometrix axis from the back side to front end as per IS 7537-1974 and the assemblies shall have provision for mounting of pole to permit directional adjustments. The lenses of red, amber or green colour shall be fabricated from 5mm dia LED’s of light intensity of minimum 5000 mcd and the electronic switching circuit wired on printed circuit board of epoxy material with transparent covering glass of polycarbonate materials. LED Viewing Angle should be 23 degree with max. Forward Current as 20 mA & lamp shall be visible from 400m under normal atmospheric conditions (Conforming to IEC60529) a) Glass with a minimum of 190 LED’s of Red/Amber colour.complete in all respect as desired by the Engineer-in-charge:-at site . | |||||
| 6.01 | Glass with a minimum of 190 LED’s of Red/Amber colour. | - | Each | - | - |
| 6.02 | Glass with a minimum of 66 LED’s of Green colour in Arrow/Walking Man hape. | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf