| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC 143 C DR RAJENDRA ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | L1 | Accepted-AOC AOC | |
| 2 | L2₹5.1 L+₹60,250 (13.3%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Higher quoted amount | |
| 3 | L3₹6.4 L+₹1.8 L (40.3%)Rejected-Finance | L3 | Rejected-Finance Highest quoted amount |
Tender Value
Refer Docs
EMD Value
₹9,319
Closing Date
29 Mar 2024, 2:00 pmClosed
ASSISTANT ENGINEER Kolkata Central Electrical Sub
OFFICE OF THE ASSISTANT ENGINEER Kolkata Central Electrical SubDivision two PWD 14 Beliaghata Main Road Kolkata 700015
Supply installation testing and commissioning of Air conditioning system at rooms of President and the entire office room of the establishment for DCDRC KOL UNIT four
2024_PWDE_686451_1
WBPWD/AE/31/Q/KCESD/II of 2023-24(2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
DCDRC KOLKATA UNIT 4
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,319
OFFICE OF THE AE KCESD 2 PWD
13 Aug 2025
15 Mar 2024
2 Apr 2024
15 Mar 2024
29 Mar 2024
21 Mar 2024
21 Mar 2024
Amount
Supply, Installation,Testing & Commissioning of split type AC machines having capacity Cooling Capacity range (6.6-7.0 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99),air-flow range CFM(780-850) both condenser and cooling coils made of copper tube connecting chord with plug top confirming to ISI 1391 (Part-I & Part-II) with all amendments. (Make-O-General/Mitsubishi Electric/Mitsubishi Heavy/)
Supply, Installation,Testing & Commissioning of split type AC machines having capacity Cooling Capacity range (5.2- 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99),air-flow range CFM(560-600) both condenser and cooling coils made of copper tube connecting chord with plug top confirming to ISI 1391 (Part-I & Part-II) with all amendments. (Make-Make-O-General/Mitsubishi Electric/Mitsubishi Heavy/)
Supply and laying of refrigerent copper pipe minimum thickness 1.15mm, liquid line 1/4" dia and gas line 5/8" dia(make- Royku/Mandeep) and insulation of copper pipe by nitril rubber insulation tube of minimum thickness 19mm(Make- Aroflex/Acoflex) incl. S&F of 3 core 2.5 sqmm PVC insulated copper wire(brand approved by EIC) for connecting indoor and outdoor units also rapping insulation and copper wire with GKB Gold raping tape.
Supply & installation of 25 mm PVC drain pipe line (25mm/32mm OD,HD 1 mm thick) of the following size with 6mm nitrile rubber insulation and with proper supports & brackets as per direction (i) 25mm dia. (Supreme/oriplast)
Breazing of copper pipes(1/4" and 1/2") by welding.
Hiring charges for scaffolding arrangement including dismantling at the end work and carriage, for AC machine installation, per storey of building per vertical run.
Lyric International
AIR COOL ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .