Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹4.2 L+₹10,486 (2.54%)Rejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance Being L2 |
Tender Value
Refer Docs
EMD Value
₹12,400
Closing Date
12 Jun 2023, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2023_MES_587255_3
GE(S)/PAT/T-75/PN/2022-23
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Patiala and Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹12,400
Yes
24 Jun 2023
23 May 2023
14 Jun 2023
23 May 2023
12 Jun 2023
30 May 2023
Amount
AIR CONDITIONER WINDOW TYPE/SPLIT TYPE M&L for Servicing of installed Window type Air conditioner of any make 1.5/2.00 TR ton capacity including taking down , dismantling from grill , taking out air conditioner, removing all electrical components, cleaning the AC coils & fin using bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing moving parts and reassembling complete all as specified and directed by Engineer-in-Charge. Note :- Various check to be doneduring servicing of Window type Ac 1.5/2.0 TR and spares/items required for replacement of unsv spare/item will be measured under relavant items.
M&L for Servicing of installed Split Air conditioner of any make 1.5/2.0 TR capacity indoor and out door units including taking down , dismantling from grill , taking out air conditioner , removing all electrical components, cleaning with brush , condenser, washing with presure water , oiling moving parts and reassembling complete all as specified and directed by Engineer-in-Charge. Note :- Various check to be doneduring servicing of Split type Ac 1.5/2.0 TR and spares/items required for replacement of unsv spare/item will be measured under relavant items.
Carrying out gas leakage check and rectifrying /arresting the same by brazing and recharging refrigerant gas, comissioning and testing for 1.5/2.0 TR capaity Window/Split AC complete all as specified and directed by Engineer-in-Charge. Note :- Gas wiil be measured under relevant item.
Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the AC unit of any capacity and type for satisfactory performance complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of defective front grill decorative suitable for window type AC's 1.5/2.00 ton capacity of any make such as LG/Videocon/Voltas/FEDDER LLOYED / BLUE STAR / CARRIER etc as per the original/existing model of air conditioner complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of operating knobs of window type AC's of any make of make and model as per the existing model/size complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement of air filter as per original sample complete all as specified for AC's 1.5/2.0 Ton of any type/any make complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable Air Conditioner cap. 1.5/2.0 ton from any posn. and removing unserviceable burnt sealed unit ( compressor ) from AC and S & Fix new compressor unit and testing on required pressure and installing at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item complete all as specified and directed by Engineer-in-Charge. Make of compressor : VOLTAS/BLUESTAR/Lloyd/carrier.
Disconnecting & Taking down unserviceable Automatic Voltage Stabilizer 4/5 KVA rating (provided for AC only. Checking & Reair of Operating Relays, Timer Relay, Relay Coil & its coneections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Transformer, high/low voltage output fault. Installing at its original position after repair and testing complete all as specified and directed by Engineer-in-Charge. Note :- Major Items for repair will be measured under relavant items.
Supply in replacement of set of Relay 04P. Relay 25 Amp - Qty 04 Nos & 01P. Relay 25 Amp (12volts)-Qty 01 No complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Timer relay for 1.5/2.0 TR AC complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Auto Swing Synchronous Motor having 5-6 rpm, 230 Volts, 50 Hz, 3 W suitable for 1.5/2.0 TR AC complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Blower/Condensor Fan PVC body matching to existing blower, suitable for window type AC 1.5/2.0 TR complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Blower/Condensor Fan 708/102 mm PVC body matching to existing blower, suitable for Split type AC 1.5/2.0 TR complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Capacitor AC 40-45 mfd matching to existing rating capacitor, suitable for compressor of window AC 1.5/2.0 TR complete all as specified and directed by Engineer-in-Charge.
M&L for checking of unsv PCB board of window/Split type AC 1.5/2.0 TR for cleaning of PCB by applying cleaning solution, testing of circuits, replacement of transistor/IC's, soldering work, AC to DC converter etc. and assembling the same after testing and working complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of remote of original company suitable to existing one or match to Split/Window AC, complete all as specified and directed by Engineer-in-Charge.
WATER COOLERS M&L for Servicing of installed Water Cooler of capacity 40/40, 40/80 & 150 Ltr of any make including taking down, dismantling from any position, disconnecting all electricl/water connections, testing of compressor functionability, testing for gas leakage/arrest of leakage, pressure of refrigerant, testing of Fan Motor, checking of flexible drain pipe, water inlet/outlet PVC pipe, checking of float valve, checking of Thermostate, operating knobs & Copper Capillary tubes, Cleaning of Cooling Coils & Fin using Bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing of moving parts and reassembling the same complete all as specified and directed by Engineer-in-Charge. Note :- Various check to be done during servicing of Water Cooler any type any capacity and spares/items required for replacement of unsv spare/item will be measured under relavant items.
Taking down unserviceable water cooler 40/80 litre cap from any posn and removing unserviceable burnt sealed unit ( compressor ) from water cooler and S & Fix new compressor unit and testing on required pressure and installing cooler at its original posn. complete all as specified and directed by Engineer-in-Charge. Note : Cost of filling with refrigerant gas is included in unit rate of this item. Make of compressor : USHA / SIDWALL / COOLSTAR / SRIRAM.
Taking down unserviceable water cooler 120/150 litre cap. from any posn. and removing unserviceable burnt sealed unit ( compressor ) from cooler and S & F new compressor unit and testing on required pressure and installing cooler at its original posn. complete all as specified and directed by Engineer-in-Charge. Note : Cost of filling with refrigerant gas is included in unit rate of this item. Make of compressor : USHA / SIDWALL / COOLSTAR / SRIRAM.
Supply & replacement of thermostat switch suitable for water coolers including knobs, plate and screws for 40/80/120/150 ltr capacity complete all as specified and directed by Engineer-in-Charge. Make : RANUTRAL / DENFOSS .
Supply and replacement Running Capacitor suitable for water cooler 40/80/150 ltr capacity complete all as specified and directed by Engineer-in-Charge. Make : USHA/UNISTAR.
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/150 ltr complete all as specified and directed by Engineer-in-Charge.
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/80 ltr complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement of Over Load Protection Relay for Water cooler 120/150 litre cap complete all as specified and directed by Engineer-in-Charge. Make : RENUTROL/SRI RAM /Indofoss
Supplying and replacement of Over Load Protection Relay for Water cooler 40/ 80 litre cap complete all as specified and directed by Engineer-in-Charge. Make : RENUTROL/SRI RAM /Indofoss
Supplying and replacement of Starting Capacitor for Water Cooler 120/150 litre cap complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement of Starting Capacitor for Water Cooler 40/80 litre cap complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable Fan Motor of Water Cooler of 150 litres capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting , clips and commissioning and testing complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable fan motor of water cooler of 40/80 ltr capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting, clips and commissioning and testing complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable Fan Motor & S&F new Fan Motor suitable for water cooler of cap 40/80 ltrs capacity complete all as specified and directed by Engineer-in-Charge Make COOL HOME/AUE/CROMPTON.
Taking down old unserviceableFan Motor of Water Cooler 150 Ltr. S&F new fan motor suitable for the same Water Cooler complete all as specified and directed by Engineer-in-Charge. Make COOL HOME/AUE/CROMPTON. NOTE : All items retrieved from this sec of sch. shall be property of contractor and contractor shall lafford credit for this account as per sch of credit.
Supply and replacement stainless steel water tap 15 mm dia, pressing type, self releasing, chromium plated push cock heavy duty (as per existing) complete all as specified and directed by Engineer-in-Charge.
Cleaning of water cooler body of capacity 40/40, 40/80/150 ltrs internally and externally including scraping and removing all scales and dirt etc. Repair to body to stop leakage and replacing unserviceable screws, nut & bolts etc. spray painting of water cooler with synthetic enamel paint hammer tone paint including prepairation of surfaces and applying red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement PVC flexible copper cable 3 core 40/0.0076 length complete all as specified and directed by Engineer-in-Charge.
Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the Compressor of Water Cooler of any capacity and type for satisfactory performance complete all as specified and directed by Engineer-in-Charge.
supply in replacement of Stailless Steel Basin Tray of water Cooler 40/80/150 Ltr complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Drain pipe flexible of size 1.5 inches long upto 1.5 mtr suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Water Inlet PVC pipe of 15 mm size including connecting to the water supply point to water cooler storage tank inlet point & ensure for no leakage of water from both points, suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Float Ball & Valve Assembely matching to the existing unsv float Ball & Assembely including fixing suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engineer-in-Charge.
Supply in replacement of Copper Capilary tube of dia 0.026 mm upto 8 to 10 feet length including High/Low Pressure convertor device, matching to the existing unsv device & capilary tubes including fixing suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engineer-in-Charge.
REFRIGERATORS/DEEP FREEZERS M&L for Servicing of installed Refrigerator 180/200/250/280/300/310/315 Ltr capacity and Deep Freezer of capacity 320 Ltr of any make including taking down, dismantling from site, disconnecting all electricl connections, testing of compressor for functionability, pressure of refrigerant, checking of Thermostate, operating buttons, testing of PCB Board & Copper Capillary tubes, Cleaning of Condensor Coils from inner side using Bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing of moving parts icludingprovinding minor nut/screws et.c and reassembling the same complete all as specified and directed by Engineer-in-Charge. Note :- Various check to be done during servicing of Refrigerator & Deep Freezer any type any capacity and spares/items required for replacement being unsv will be measured under relavant items.
Taking down unserviceable Refrigerator 300/310/315 Ltr capacity from the site and transporting to workshop for repair, removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as specified and directed by Engineer-in-Charge. Make : SRIRAM / KIRLOSKAR.
Taking down unserviceable Refrigerator 180/200/250/280 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as specified and directed by Engineer-in-Charge. Make : SRIRAM / KIRLOSKAR.
Taking down unserviceable Deep Freezer 300/320 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as specified and directed by Engineer-in-Charge. Make : SRIRAM / KIRLOSKAR.
Recharging of Refrigerant Gas R-134A complete including testing of leakage and testing the Compressor of Refrigerator/Deep freezer of any capacity and type for satisfactory performance complete all as directed by Engineer-in-Charge.
Supply in replacement of Copper Capilary tube of dia 0.031 mm having lenth upto 8 to 10 feet including High/Low Pressure convertor device, matching to the existing unsv device including fixing of the same suitable for 310/315/320 Ltr capacity Refrigerator/Deep Freezer complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing as in repairs of Refrigerator door (plastic) complete with tension spring as per original complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing as in repairs of 320 Ltr acpacity Deep Freezer door (Plastic) complete with tension spring as per original complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing as in repairs lce Tray plastic as per original complete all as specified and directed by Engineer-in-Charge.
Supply &Fixing as in repairs fruit/ vegitable Tray as per original complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing as in repairs fruit/vagitable Glass cover complete as per original complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of pigmy Lamps (bulb) of refrigerator complete as per existing complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing as in repairs Refrigerator door seal (gasket)/flexible elastic strip attached to the outer edge of refrigerator or freezer compartment in the Refrigerator/Deep Freezer of cap 180/310/315/320 Ltr complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing as in repairs door megmetic gasket complete as per original make for refrigerator 300/310 ltr capacity complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement Relay Box type for 310/315 Ltr capacity refrigerator complete all as specified and directed by Engineer-in-Charge.Make : RENUTROL/SRI RAM .
Supplying and replacement of Over Load Protector Single Phase 230 Volts, 50 Hz suitable for Refrigerator/Deep Freezer 180/300/310/315 Ltr capacity complete all as specified and directed by Engineer-in-Charge. Make : Renutral/SRIRAM
Supplying and replacement of door lock with two keys as per original specification for Refrigerator 180/310/315 Ltr complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement of drian water Collector container made of PVC suitable for Refrigerator 180/300/310/315 Ltr Capacity complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement of Copper Filter Drier in Refrigerator 180/310/315 Ltr capacity complete all as specified and directed by Engineer-in-Charge.
Disconnecting & Taking down unserviceable Automatic Voltage Stabilizer upto 2 KVA rating connected to Refrigerator/Deep Freezer/Water Coolers. Carry out repair to Operating Relays, Timer Relay, Relay Coil & its connections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Soldering work, Transformer, high/low voltage output fault. Installing at its original position after repair and testing complete all as specified and directed by Engineer-in-Charge. Note :- Cost of spares/parts required to be replacement will be included in quoted rate.
Supplying and replacement of voltmeter of range 0-500 volts single phase 230/240 volts, 50 Hz suitable for Refrigerator/Deep Frizeer 180/310/315 Ltr capacity complete all as specified and directed by Engineer-in-Charge.
Supplying and replacement of Indian Thermostate for single door/double door Refigerator 180/310/315 Ltr/Deep Freezer 320 Ltr as per existing rating of thermostate compatible for Voltas/Samsung/Usha/Blue Star/Kelvinator/Godrej/Whirlpool complete all as specified and directed by Engineer-in-Charge.
u and v engineers and consultants
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .