Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.7 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹14.4 L+₹67,519.30 (4.93%)Rejected-Finance H NO 13149 STREET NO 3 SHIV COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹14.8 L+₹1.1 L (7.77%)Rejected-Finance MCB Z 5 04939 GURU GOBIND NAGAR BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | 3 | Rejected-Finance Not Lowest |
Tender Value
₹14.6 L
EMD Value
₹29,000
Closing Date
15 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Addn/alteration cook house Bldg No P-146 and P-147 of Inf Bn-II at Mil Stn Abohar
2021_MES_436463_1
GE ABH-04/21-22
Open Tender
Civil Works
Item Rate
120 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category a (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
Garrison Engineer Abohar
₹29,000
Yes
14 Aug 2021
18 May 2021
17 Jun 2021
18 May 2021
15 Jun 2021
2 Jun 2021
60 days
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge .
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work
M & L mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge .
All as per Srl item No. 4 here in before but 5mm and over for as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge.
M & L RCC 1:2:4, (nominal mix), type B-1using 20mm graded stone aggregates for slabs supported on walls, beams, columns and in shelves, the like all as specified and directed by Engineer - in - Charge .
M & L form work to soffits of suspended slabs such as roof slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge .
M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
Demolition of brick work built in cement mortar all as specified and directed by Engineer - in - Charge.
M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
All as above but except bricks all as specified .
M & L brick work with sub class ‘B’ old size burnt fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
Dismantling floor or wall tiles including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer - in – Charge.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick cement sand (1:4) as in backing coat complete all as specified .
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer - in - Charge.
M & L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid over and including 15mm thick screed bed in cement mortar 1:6 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
M & L Machine cut kota stone slab 20 - 25 mm thick in riser of steps,skirting,dado and pillar over cement screed base laid over and including 10mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
M & L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick cement mortar 1:4 all as specified and directed by Engineer - in - Charge .
Cutting ,grinding,cleaning and treating the surface of existing kota stone flooring withbeeswax polishing complete as directed by Engr-in Charge.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.0 Sqm each & refixing in same opening all as specified and directed by Engineer - in - Charge .
S & F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified .
Hacking out old broken glass from metal frame including punching or drilling out old glazing pins and providing and fixing new ones complete all as specified and directed by Engineer - in - Charge .
S & F figured glass 4mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pan complete all as specified and directed by Engineer - in - Charge .
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm with waste pipe PVC 40mm dia all as specified and directed by Engineer-in-Charge . (ISI Marked)
S&F in repair 15mm bore bib taps,chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, secrewed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in- charge.
S & F in repairs 15mm bore stop cock one way fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified .
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm all as specified and directed by Engineer - in – Charge.
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing all as specified .
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified .
S & F Vitreous china wash hand basin white flat black of size 550 x 440mm including brackets, waste pipe and waste fitting 40mm brass chromium plated and waste pipe and 15mm dia PVC connection with brass nuts as in repairs complete all as specified and as directed .
S & F in repairs CP Towel rail 16 mm dia 600 mm long superior quality complete all as specified .
S & F soap dish fixed as chromium plated all as specified & directed.
Taking down steel tubing 15mm bore and connections including cleaning for refixing/ removal complete all as specified and directed by Engineer - in – Charge.
Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified and directed by Engineer - in - Charge .
S & F 15mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge .
Taking down steel tubing 20mm bore and connections including cleaning for refixing/ removal complete all as specified and directed by Engineer - in – Charge.
Fixing only tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified and directed by Engineer - in - Charge .
S & F 20mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge .
Dismantling water tanks of capacity exceeding 250 litres and not exceeding 500 litres all as specified and directed by Engineer - in - Charge.
S & F rotational moulded polythene water storage tanks, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed by Engineer - in - Charge .
S & F ball brass valve 20mm bore dia high pressure with polythene float and fly nuts complete screwed with iron pipe or brass ferrule and fixed all as specified and directed by Engineer - in - Charge .
S & F gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore complete all as specified and directed by Engineer – in – Charge.
S & F gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore complete all as specified and directed by Engineer – in – Charge.
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete.
S & F PVC pipes (SWR) single socketed with rubber ring joints 75mm dia laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge .
S&F for 75mm bore PVC (SWR) junction single,(single T) equal or unequal with access door .
S&F for 75mm bore PVC (SWR) junction double,(double T) equal or unequal with access door .
S&F PVC ( SWR) bends any radius bore of 75 mm with access door all as specified and directed by Engineer - in - Charge
S&F for 75 mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement.
S & F grating round 125mm with waste hole of PTMT (minimum weight 40 gms) all as specified and directed by Engineer - in - Charge.
Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge.
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L three coats of white wash including preparing new plastered or unplastered surfaces of ceiling complete all as specified and directed by Engineer - in - Charge.
M & L two coats of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
M& L for three coat of colour wash on New surface of walls including necessary preparation
M & L two coat of colour wash to old decorated plastered or un-plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in - Charge.
M & L applying two coat of cement base paint on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge
M & L two coats of cement paint on plastered wall surfaces including preparation of surface after complete removal of existing treatment complete all as specified and directed by Engineer - in - Charge .
M&L for preperation of old wooden surface and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified .
Providing and applying microfibre reinforced UV resistant Acrylic polymer coating three coats having solid contents 69% polymer content 35% & tensile strength 2.6 N/mm2 of Dr. Fixit Newcoat/stat/Parex or equivalent with a paint brush over existing roof surface after removal of all loose material, lime dust etc. with wire brushes, coir brushes from roof surface to get absolutely cleaned surface free of foreign contaimnant filling of cracks wherever found with polymer based mortar, and after repairing the surface apply primer coat with Dr. Fixit Primeseal. Polyester reinforced fiber net laid on the surface after the first coat and all the joints of bricks is repaired by polymer based mortar. Undulation on the surface repair before executing the water proofing treatment including 15mm thick plaster in CM 1:4 as screed finished even joint of slab and wall of roof complete all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' SECTION-II (E&M PORTION)
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out comlete all as specified.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc comlete all as specified.
Removing excavated material n exc 50m and depositing where as directed at a level n exc. 1.5 m above the starting point comlete all as specified.
Sand filling under flooors or in foundation including and consolidation as as specified and directed at site comlete all as specified.
M & L brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes including provision of cable gland/aluminium lugscomplete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and as directed.
M & L point wiring (Concealed) with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete all as directed for the following.
One light/Bell/fan point controlled by one way switch 5 Amp.
one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq mm size complete.
one 3 pin socket outlet, 5 Amps on independent board with other switches, with cables 1.5 sq mm size complete.
Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
Description all as per item No 08 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep suitable lenth and painted with red oxide primer in place of unserviceable shunken box complete for housing switches, , regulators, bell push etc, complete all as directed for the following.
One light / fan point controlled by one way piano switch 5 Amp.
One socket point 5 Amp on an independent board.
One socket point 5 Amp on same board
Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
S & F switch piano ,flush type single pole, one way 5 amp, 2way 5 Amp,/bell push all as directed.
S & F switch piano ,flush type single pole, one way 6/15 Amps 5 pin complete all as speccified aand directed.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete.
M & L for celling rose 3 pin/pvc/ polycarbonate isolated body complete all as specified and as directed.
M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska SSK-SQ2001 20W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
S&F sheet metal enclouser TPN DB having facility to fix MCCB incomer upto 125Amps (Load line) and MCBs in outgoing, TPN 8 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways s all as specified and directed by Engg-in-Charge.
S&F MCB SPN 63 Amps, 240 Volts complete all as specified.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
M&L for submain wiring comprising single core ,4 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete, including provision of 2x6 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per item No 30 here in before but ,2 Runs of 6 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
Description all as per item No 30 here in before but ,2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge .
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Supply and fixing MCCB TPN ( 4 pole) 100 Amps 415 Volts of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :IndoAsian Cat No: 830330 to 830335 or equvalent of Havells/LegrandSchneider/HPL/Standard
Supply and fixing MCB TPN 63 Amp, 10 KA 415 Volt in repair. Make : Havells/Legrand
S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in Schedule 'A' of Item No 31 & 32).
S&F for Condenser 2/2.5 MFD. (Make : Universal (metal body).
S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
Supply only ball bearing number of 6201/6202/6203/6204 as required. (Make : SKF/NBC).
Supply only gun metal bush as required.
Taking down/dismantling complete Ceiling/exhaust fans of any size for spray painting with two coat of synthetic enamel paint of approved colour including filling cavities with filler on coat after cleaning all dust etc. including re-assembling the same and testing after writing of MES NO on completion.
S&F batton holder insulated body with back plate inluding 12 watts LED lamp complete all as specified.
S & F GI tube light grade galvanised of size 40 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge. (MAKE: JINDAL/PRAKASH/SURYA)
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska/Polycab as recommended by Engr-Incharge and approved by GE.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water.
S&F for copper (CP) hot water pipe 450 mm length (heavy duty) for Geyser, connection with check nut and washer.
S & F BLDC (brushless direct current) Motor Ceiling fan 1200 mm sweep 5 star rating , single phase 240 volts, power consumption 26 Watt to 32 Watt on turbo mode with remote control, 220 CUM/Min. single phase, 50Hz. 240 volts warranty 2 years on product complete and accessories. Make: Atomberg Gorilla/Havells Efficiencia Neo/Crompton/ White or equvalent of CG/Luminous/Orient
S & F Geyser storage type, electric driven of capacity 25 Ltrs 5 star rating, with 8 bar pressure with standing ,rust proof, rust proof fire retardant cable adj thermostat anti corrosion protective device inner tank mild steel with glass lined coating including PVC connections and grouting of bolts with nut of suitable size including cement work for make good the disturbed surface etc complete all as specified and as directed .Make:: Bajaj cat No Caldia or equavalent in CG, Havells,
S&F Exhaust fans (Heavy duty) 450 mm sweep 230/240 volts single phase with self closing louvers GI off mode protection against birds etc and provision of cutting of walls suitabully for fixing exhaust fan and necessary plastering and making good the disturbed surface to match with existing complete all as specified. Make: Havells ventilair DB 300 mm or equvalent of Orient/Usha/
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
M/s Verma Construction Company
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .