Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance AIMANATHU CHANGANASSERY KURICHY P O KOTTAYAM | CHANGANASSERY | KOTTAYAM | KERALA | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical NON-RESPONSIVE |
Tender Value
₹19 L
Closing Date
16 Sept 2021, 2:00 pmClosed
DY. GEN. MANAGER
Office of the Deputy General Manager, JKPCC Ltd., Unit Electrical, Rail Head Complex Jammu.
Providing and Fixing of internal Electrification work at Indoor Stadium Gool, Ramban.
2021_PWDJK_138677_1
e-NIT No. 17/ELECT of 2021-22 Dt. 09-09-2021.
Open Tender
Electrical Works
Item Rate
90 days
RAMBAN
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
Financial Controller, JKPCC Ltd.
Exempted
Dy. Gen. Mgr. Elect. Unit, JKPCC Ltd.
24 Sept 2021
10 Sept 2021
16 Sept 2021
10 Sept 2021
16 Sept 2021
10 Sept 2021
11 Sept 2021
Amount
Sub Head-I(Wiring) Providing Primary light point wiring using 2 x 2.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit,with modular switch, modular plates & suitable GI Box.Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(SB Controlled Primary light Points) Make:- KEI/POLYCAB/PARAMOUNT
Looping above light point ( say secondary light point using 3 x 1.5mm2 stranded copper/FRLS PVC insulated wires laid in 20 mm Dia. PVC MMS conduit;with modular switch, modular plates & suitable GI Box;. . Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture. (SB Controlled Secondary light Points) Make:- KEI/POLYCAB/PARAMOUNT
Providing Primary light point wiring using 2 x 2.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(DB Controlled Primary light Points) Make:- KEI/POLYCAB/PARAMOUNT
Looping above light point ( say secondary light point using 3 x 1.5mm2 stranded copper/FRLS PVC insulated wires laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(DB Controlled Secondary light Points) Make:- KEI/POLYCAB/PARAMOUNT
Wiring for fan point/ exhaust Fan/call bell point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in Surface/ recessed medium class PVC Conduit , with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.Make:- KEI/POLYCAB/PARAMOUNT 2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM EARTH WIRE
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM EARTH WIRE
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 25 amps modular Multi pin socket outlet with connection,painting etc. as required.
Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required(NORTHWESTAnchor Roma Plus/L&T)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (NORTHWESTAnchor Roma Plus/L&T)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Sub Head-III(DB's and MCB's) Supplying and fixing following way,Prewired TP&N PPI Distribution Board of Sheet Steel for 415 Volts on surface/Recess complete with Ready to use DBs - Provided with 100A insulated phase bus-bars,neutral bar/s with shroud/s, earth bar/s , sticking saddles , cement spill protector ,color-coded interconnecting wire set , cable ties , blanking plates and circuit identification labels.The D.B should be IK-09 Compliant.(The Cost of D.B is without MCB's)(IP Rating-43)(SIEMENS/SCHNEIDER/NORTHWEST) 6Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(6+6+6) SP MCB's O/G's)
Supplying,Installation ,Testing and Commissioning of Four Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required 25 Amps
Supplying and Fixing Following rating,Double Pole (Single Phase and Neutral),240 Volts Residual Current Circuit Breaker (RCCB) having a sensitivity of current upto 300 ma in the existing MCB DB Complete with connections ,testing and commissioning as required. 40 Amps
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Double Pole
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 8 Way
Supplying and Laying of B-Class 80 mm Dia Size G.I Pipe under the Road/Floor not less than 1 mtr below the Ground Level including cutting the Road/Floor and making Good the same as required.
Sub Head-IV(Lightning Conductor and Earthing) ENVIRONMENTALLY SAFE MAINTENANCE FREE EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value. Supply, installation, testing and commissioning of Advanced Maintenance Free environment friendly Earthing system consisting of 1 no. of 3mtr length, 17.2 mm dia UL certified earth electrode made of high tensile low carbon steel circular rods, molecularly bonded copper on outer surface (minimum copper bonding thickness-250 microns) with GI terminals to connect incoming strips, (Environment friendly backfill compound duly certified as per ANSI/NSF standard 60/Toxic content certificate as safe for use near potable ground water resources strictly as per specification enclosed. Make- SHREE ELECTRODES/OBO BETTERMANN/ERICO Earth pit chamber (300mm x 300mm) with CI cover for the above.
Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.
Sub Head -V(SITC of Fans and Fittings) SITC of Ceiling Fan,Capacitor type suitable for low voltage operation including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 1200 MM SWEEP
SITC of pre-wired 18 Watt Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture should have System Efficacy of 85 Lumens/Watt. (PHILIPS/WIPRO/BAJAJ) Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired 6 Watt Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture should have System Efficacy of 85 Lumens/Watt. (PHILIPS/WIPRO/BAJAJ) Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired LED Street Light Fixture Bracket Mounted Fitting 90 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required. The Light Fixture should have System Efficacy of 85 Lumens/Watt. .Refrence Model:- Bajaj BRTFG 90 W LED I (PHILIPS/WIPRO/BAJAJ) Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired Surface Mounted LED Flood Light Fitting 250 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture Should Have System Efficacy of 125 Lumens/Watt. Refrence Model:- WIPRO LF-20-342-060-57 G2 250 W (PHILIPS/WIPRO/BAJAJ)
SITC of pre-wired Surface Mounted LED Flood Light Fitting 350 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture Should Have System Efficacy of 125 Lumens/Watt. Refrence Model:- WIPRO LF-20-442-060-57 G2 350 W (PHILIPS/WIPRO/BAJAJ)) Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired Surface Mounted LED Flood Light Fitting 80 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture Should Have System Efficacy of 130 Lumens/Watt. Refrence Model:-WIPRO LF-19-931-060-57-XX 80 W (PHILIPS/WIPRO/BAJAJ) Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
Supply of AC 230/250 Volts, 50 Hz exhaust fan with louveres of Following Sizes including connection etc. complete as required . Makes:-(WADBROS/CATA/VENTS/EXPLAIR) 150 mm
ON/OFF/TRIP Lamps(02 Sets) APFCR 5 Stage(01 Nos) SMPS Suitable for 24 Volt Coils for Contactor Operation TPN Mcb 6A (06 Nos) DLM(02 Nos) OUTGOINGS MCCB 63 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(03Nos) MCCB 40 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(03 Nos) MCCB 32 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(01 Nos) MCCB 25 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(01 Nos) MCCB 16 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(02 Nos) MCCB 20 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(02 Nos) 5A Capacity Duty Contactor 480 Volts (02 Nos) 12.5A Capacity Duty Contactor 480 Volts (02 Nos) 7% 5 KVAR ,440 Volts Detuned Reactors(02 Nos) 7% 10KVAR ,440 Volts Detuned Reactors(02 Nos) Power Capacitors 7.5 KVAR 480 Volts(02 Nos) Power Capacitors 12.5 KVAR 480 Volts(02 Nos) Load Bearing Members to be made out of 1.6 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.
Servo Transformer/UPS/Lightning Conductor/Under Ground Cables and Accessories Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required . 90mm/75mm
Supply , loading , Transport ,Unloading , shifting ,laying, testing and commissioning of 11KV/1.1KV Grade XLPE/PVC insulated aluminium/copper multistrande conductor steel of armoured/flexible braid power cables as per the specification. Laying of Cables in horizontal/vertical formation on cable trays, supported along RCC/steel structures if required , pipe racks and cable supports provided,Ground , include unloading, shifting upto site at various location/levels, unpacking & inspection.The scope includes clamping of cables by ready made spacers, saddles or clamps fabricated out of Aluminium strip 3 mm thick along veritacal runs and wherever specified,cutting of the cable as per actual mesurement/cable schedule, Treasing and Clamping of Cable on cable tray velcrow tap of minimum 20mm width or clamping materials in Aluminium or PVC cable tie as per site Conditions.Makes:-(Polycab/KEI/Paramount) 3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required 3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supplying and Installing Following Size of Perforated G.I Cable Tray with Perforation not more than 17.5% in convenient Sections ,joined with connectors ,suspended from the Ceiling including bolts and Nuts ,etc as required. 200mm (W) x 50 mm (H) wide cable tray perforated type
450mm (W) x 50 mm (H) wide cable tray perforated type
Sub Head-VII(ELV) Supplying,Installation,Testing and Commissioning of I/O Modules Complete with Box,RJ-45 Socket,Front Plate as per the Satisfaction of the Engineer Incharge.(SCHNEIDER/LEGRAND/NORTHWEST)
Supplying,Installation,Testing and Commissioning of I/O Modules Complete with Box,RJ-11 Socket,Front Plate as per the Satisfaction of the Engineer Incharge.(SCHNEIDER/LEGRAND)
Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required. 25mm PVC Conduit
Supplying and Drawing of UTP4 pair CAT-6 LAN cable in the existing surface/Recessed Steel/PVC Conduit as required .
Supplying and Drawing of 3 Plus 1 CCTV cable in the existing surface/Recessed Steel/PVC Conduit as required .
Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/PVC conduit as required.
Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC, Make : AMP/Krone/Schenider
Supply, installation, testing and commissioning of Junction Boxes/DB-20 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC
Supply, installation, testing and commissioning of 20 Pair jelly filled armoured cable of 0.5mm of each Pair Telephone Cable in the existing surface/ recessed steel/ PVC conduit, complete in all respect as per specification and desired by EIC
Supplying,Installation,Testing and Commissioning of 40 Inches Full H.D LED Display Monitor as per the Specifications attached.(SAMSUNG/LG/SONY)
Supply, Installation, Testing and Commissioning of Digital video recorder (DVR) having following features. Input : 16 channel video and audio inputs
Supply, Installation, Testing and Commissioning of 2 Megapixel 1080P Full HD IR Bullet Camera.
Supply, Installation, Testing and Commissioning of 8 TB Surveillance AV Storage Device.
Supply,Installation,Testing and Commissioning of Full Brass Network Connectors and Power Connector
Supply,Installation,Testing and Commissioning of 12V 10A Power Supply Units for Bullet Cameras
ROYAL ENGINEERS AND CONTRACTORS
M.K.Brothers
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .