Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC Awarded to M/S MK Enterprises | |
| 2 | Rejected-Technical AT KHUDGADDA NEW BASTI SAWANG BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | - | Rejected-Technical Not Evaluated | |
| 3 | Rejected-Technical AT WASHERY ROAD KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Not Evaluated |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
31 May 2024, 4:00 pmClosed
Staff officer ENM
Office of the staff officer EnM kathara Area
Internal electrical repair/maintenance of partial rewiring with switch board,switches, socket outlet, MCB board,main switch and earth continuity etc at Qtr no B/5,SPL 3A/2,SPL 3B/1,SPL 3A/3,2A-2,WB-52 under G M Unit Kathara.
2024_CCL_308599_1
GMKTA/SOEnM/E-tender/24-25/02
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Kathara Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
21 Jun 2024
20 May 2024
1 Jun 2024
21 May 2024
31 May 2024
21 May 2024
21 May 2024 - 28 May 2024
Amount
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with Modular type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVCinsulated Copper conductor single core cable etc. as required. (Group –“C”)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x1.5Sq.mm+ 1.5sq.mm earth wire)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x2.5Sq.mm+ 2.5sq.mm earth wire)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x4Sq.mm+ 4sq.mm earth wire) for main service connection
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (5/6 Amp Switch).
…………Do…………….5/6Amps. Socket outlet
…………Do…………...15/16 Amps Switch
………..Do…………… 15/16 Amps Socket
Supplying and fixing of modular type electronic regulator Supplying & fixing stepped type electronic fan type regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
Supplying and fixing metal /PVC box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps modular type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).COST FOR EACH
Supplying and fixing metal /PVC box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps modular type switch, connection, painting etc. as required.COST for EACH
Supplying and fixing of following sizes of medium class PVC conduit/ cashing along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.(20mm dia PVC conduit/ cashing )
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Details of cost for 1 Metres
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr. long etc. with charcoal/coke and salt asrequired.
Supplying, installation, testing and commissioning of following capacity overhead distribution bus trunking with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections with provision of tapping points for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply including jointing of sections, bends, earthing with 2 runs of galvanised iron strips, all installation accessories etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 A TP&N Details of cost for one each
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door . Details of cost for one
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Providing of PVCboard 8''x10''
Providing of PVC board 4''x6''
Total impact of GST for the purpose of CTC
M/S SHYAM ELECTRICALS
M/S S K ELECTRICAL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_319766.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .