Closing Date
23 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR MAINT TO SHED FOOTPATH PLINTH PROTECTION CULVERTS DRAIN COVER SLABS AND CERTAIN MISC BR WORKS IN ZONE A AREA AT GMS UNDER GE I GOS
2021_MES_446393_1
8000/30/21-22/0929/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹50,000
Yes
9 Aug 2021
28 May 2021
25 Jun 2021
28 May 2021
23 Jun 2021
16 Jun 2021
Amount
S&F pre- painted galvalume aluminum zinc corrugated steel based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping serews complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed.
M&L preparation of new steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed.
S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/ hard standing surface finished even and fair complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base,floor , plinth protection etc and finishing cement concrete even and fair complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed.
M&L for providing Glass strip of 6 mm thick and 40 mm deep in hardstanding for making panels complete all as specified and directed.
M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of mortar in CM 1:4 for laying floor finishes complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for finishing cement concrete even and smooth using extra cement complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in Surface channels and drains etc complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed.
Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 500 ltr n.exc 1000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
S&F in repair ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repair ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed.
S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc complete all as specified and directed.
Dismantling fencing wire mesh any type etc complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out making good the disturbed surface if required in soft/ loose soil complete all as specified and directed.
M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Mild Screw bolts (Machine made) with hexagonal or square head at one ends and to fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm complete all as specified and directed.
S&F PVC coated chain link of 3.16mm dia mild steel galvanised fencing of mesh size 75 mmx 75mm as per IS : 2721-2003 weight n exc 4.00 kg per sqm complete all as specified and directed.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 300 mm to 450 mm internal dia of pipe complete all as specified and directed.
S&F in repair reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 300mm dia complete all as specified and directed.
S&F in repair reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 450mm dia complete all as specified and directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm high etc complete all as specified and directed. (Note : Rates to be deemed fit for all security measures while working in heights more than 6m from GL).
Taking down rolling shutters including all hardware fittings complete all as specified & directed
S&F 1 mm thick of steel rolling shutters without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, push pull or manual type complete all as specified and directed.
S&F 1 mm thick of steel rolling shutters without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, but gear operated type with bevel gear box and crank handle complete all as specified and directed.
S&F Ball bearing for rolling shutters complete all as specified and directed.
M&L Cutting holes in brick walls exc one brick but not exc two brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
Taking down cover hood of existing rolling shutters (gear operated/ manually size any type ) carefully and completely over hauling the shutters by applying grease and oil in bearing, springs, guide cannels, operating rods, shaft gear boxes, gear wheel etc straightening thoroughly shutter blades, guide channels anchoring rods etc and fixing back the over hood in position and ensure smooth functioning of shutters complete all as directed. (Note : worn out part for replacement will be measured and paid separately.)
Supply and fixing in repairs only following parts of steel rolling shutters complete all as specified and directed:- (a) MS gear box complete incl handle and anchoring rod as of approved quality
(b) Ball bearing suitable for rolling shutter
(c) Guide channel 3" (3.50 mm thick)
(d) Cover hood made of 1 mm thk plain GI Sheet pattern
(e) Bottom plate 5" (2.25mm)
(f) C Class pipe 50 mm dia in shaft
(g) Anchoring rod of 25 mm dia of MS pipe
(h) Safety lever locks MS with 4 levers
M&L Removing old paints by paint removes or burning off by blow lamps and cleaning with scrapers, any number of coats,any width or girth complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, thickness of metal to be welded exc 3 mm but n exc 6 mm complete all as specified and directed. (Note : Taking down the article and refixing in position after welding shall be measured separately)
M&L for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, thickness of metal to be welded exc 6 mm but n exc 9 mm complete all as specified and directed. (Note : Taking down the article and refixing in position after welding shall be measured separately)
Taking down the grills/ gratings or material to be welded and refixing in position after welding complete all as specified and directed.
Taking down Collapsible steel gates incl all hardware fitting complete all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed .
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed
M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on newly prepared surfaces including, rubbing with sand paper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and applying three coat of white wash complete all as specified and directed.
M/S K MURALIDHARA PATRA
V.Venkata Ramaiah
M/s Ats Electricals
HARAGOURI SUPPLIERS
M/S SIWALIK AND CO
ABC CONSTRUCTION COMPANY
M/s MAA BHAIRABI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .