Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹48.6 L+₹4.7 L (10.8%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 3 | L3₹50.5 L+₹6.6 L (15.1%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 4 | L4₹52.8 L+₹8.9 L (20.4%)Rejected-Finance ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | L4 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 5 | L5₹55.1 L+₹11.2 L (25.4%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DINJAN
COMMANDER WORKS ENGINEERS DINJAN
COMPREHENSIVE MAINT AT SARAIBARI AREA IN JORHAT MIL STN
2023_MES_633981_2
84245E8
Open Tender
Civil Works
Item Rate
270 days
GE JORHAT
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE JORHAT
₹90,000
Yes
22 Mar 2024
9 Feb 2024
28 Feb 2024
9 Feb 2024
21 Feb 2024
16 Feb 2024
Amount
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed.
Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 25 mm thick finished even and fair complete all as specified and directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges or slab staging for water tank complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 20 cm X 20 cm X 25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 15 mm thick bedding of cement mortar(1:6) all as specified and as directed.
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M & L for hardcore (broken bricks) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and smooth without using extra cement complete all as specified and directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, glossy finish of approved colour, laid in required colour and pattern over 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. Note- Rate of Sand filling shall be measured and paid separately.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for plastering 15 mm thick on other than fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer-in-charge.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed
M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M & L for mild steel round bars10 mm dia, Fe 410 W(Gde E-250)/Fe 290 (Gde E-165), cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exceeding 10 kg each brackets (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed.
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed.
Supply only galvanized steel chain link fence fabric of mesh size 100 mm X 100 mm, made out of 3.15 mm nominal dia of mesh wire.
Fixing only galvanized steel chain link fence fencing including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc. including provn of binding wire complete all as specified and as directed.
S & F in repairs galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to any type of standards, rails, straining bolts including securing or tying at crossings with and provision of galvanised iron binding wire, GI staples or steel pins, etc. complete all as specified and as directed (two strand of line wire will be measured as one unit).
S & F mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long complete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc into primary parts.
Dismantling posts or struts (wood, steel or RCC.) any section embedded in concrete, brick work, masonry, etc., including taking out embedded portion and making good disturbed ground
Dismantling fencing wire mesh, any type complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping/ concealed including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
M & L for point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for capping casing point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for concelled point wiring for one 3 pin/ 5 pin 6 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC pipe of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for capping casing point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch, 6 A, single pole, two way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F in repairs switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F in repairs switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and indicator and fuse complete all as specified and as directed.
S & F in repairs step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
Supply only fan capacitor 2.5 MFD complete all as specified and directed. MAKE : Bajaj / Universal / Usha.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F LED tube light nominal power 20 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F LED panel type, recess type, ceiling mounted light fitting 36 watts with high power LEDs as light source and electronic driver complete all as specified and as directed.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of casing/capping shall be measured and paid as one unit length.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of casing/capping shall be measured and paid as one unit length.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F angle holder Bakelite 6A, 230 volt make Anchor complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 8 way with 200 Amps rated bus bar, 415 volt, IP43 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, including taking down old unsv DB, complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP43 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, including taking down old unsv DB, complete all as specified and as directed.
S&F MCB TPN 63 Amp 'B' series 10KA 240 volts complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A-63A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Supplying only in repairs, PVC insulated cable for working voltages of 1100 V, PVC sheathed, 2 core, flat or circular nominal cross sectional area of main conductor 4 sqmm, solid copper conductor, ISI marked as per IS 694 complete all as specified and as directed.
S & F in repair MCCB, Fixed Thermal & Fixed Magnetic setting, 4 pole, 415 volts, 25 kA, 63 A complete all as specified and as directed.
S & F in repair MCCB, Fixed Thermal & Fixed Magnetic setting, 4 pole, 415 volts, 25 kA, 100A complete all as specified and as directed.
S & F in repair MCCB, Fixed Thermal & Fixed Magnetic setting, 4 pole, 415 volts, 25 kA, 125 A complete all as specified and as directed.
S & F in repair MCCB, Fixed Thermal & Fixed Magnetic setting, 4 pole, 415 volts, 36 kA, 200 A complete all as specified and as directed.
S & F MCCB DB vertical, TPN, 160 A, double door, 8 way, IP43 protection with provision for door earthing and mechanical impact strength IK 08 complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S & F in repairs bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F in repairs for modular switch, 1 way, 6 A, 1 module complete all as specified and as directed.
S & F in repairs modular bell push, 6A, 1 module, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed
S & F in repairs modular switch socket combination, 3 modules with 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F in repairs (3 pin and 2 pin) combined modular socket outlets, 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F in repairs modular switch, 16A, single pole, one way, one module, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F in repairs (3 pin and 3 pin) with common earthing pins, combined modular socket outlets, 6A & 16A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F in repairs Modular fan regulator, 120 W, 2 modules complete all as specified and as directed.
S & F in repairs buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F in repair cylindrical shape, integral decorative LED bollard luminaries 9 watt, mushroom shape opal acrylic diffuser, die-cast aluminium base, inbuilt drive with 4.5 kV surge protection, base plate and fixing hole suitable to be mounted on concrete pedestal, IP65 protection with high power LEDs as light source complete all as specified and as directed.
Supply and fixing LED inverter type bulb of capacity 09 Watt complete all as specified and directed.
Supply and fixing LED inverter type bulb of capacity 12 Watt complete all as specified and directed.
S & F in repairs slim, compact, aluminium die cast edge lit panel, recess mounted round fixture with opal diffuser and separate electronic driver, ceiling cutout 210 mm dia, 18 watt, colour temperature 3000k to 6500k as per Model No. LHEBHDP5IZ1W018 of Havells or equivalent of Make mentioned under Appendix ‘B’ to Particular Specification complete all as specified and as directed.
S & F in repairs slim, compact, aluminium die cast edge lit panel, recess mounted square fixture with opal diffuser and separate electronic driver, ceiling cutout 160 mm X 160 mm, 12 watt, colour temperature 3000k to 6500k as per Model No. LHEBHEP5IZ1W012 of Havells or equivalent of Make mentioned under Appendix ‘B’ to Particular Specification complete all as specified and as directed.
S & F in repairs slim, compact, aluminium die cast edge lit panel, recess mounted round fixture with opal diffuser and separate electronic driver, ceiling cutout 180 mm dia, 15 watt, colour temperature 3000k to 6500k as per Model No. LHEBHDP5IZ1W015 of Havells or equivalent of Make mentioned under Appendix ‘B’ to Particular Specification complete all as specified and as directed.
Preparation of old decorated surfaces on walls and applying one coat of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed.
M & L for preparation of old surface of walls including chajjas, facias etc. by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of weather proof acrylic exterior paint (100% Acrylic) including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for preparation of old surfaces of wall by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of cement base paint complete all as specified and as directed.
M & L for complete removal of existing treatment and preparation of surfaces and applying two coats of cement base paint complete all as specified and as directed.
M & L for complete removal of existing finish on walls including chajjas, facias etc. and filling of holes and flake out portion with appropriate quality putty and applying two coat of weather proof acrylic exterior paint (100% Acrylic)over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of old painted wood or wooden surfaces, of any description, not exceeding 10 cm width or girth when unconnected with other painting or when painted in different tint and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
M & L for preparing galvanised surfaces of roof to receive painting by coating with mordant solution including washing and cleaning and applying two coats of antisol roof paint of Berger or equivalent of Make as mentioned under Appendix "B" over a coat of primer as per the manufacturer's instruction complete all as specified and as directed.
Complete removal of existing treatment and treating with two coats of 100% Premium acrylic emulsion paint having VOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over new surfaces complete all as specified and directed.
Complete removal of existing treatment and treating with two coats of 100% Premium acrylic emulsion paint having VOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over a coat of 1mm thick wall care putty complete all as specified and directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement mixing with WPC complete all as specified and as directed. Note- WPC shall be measured and paid separately.
M & L for 15 mm thick cement plaster on fair faces of bricks/ concrete surfaces in cement mortar 1:6 including plastered surfaces shall be finished even & smooth without using extra cement all as specified and as directed by Engineer-in-Change
Preparing newly plastered surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over a coat of 1mm thick wall care putty complete all as specified and directed.
M & L for writing letters or figures in (Roman/ Indic Script) (Bold/ Italic/ Capital/ Smaller type) not exceeding 30 cm in height with synthetic enamel paint complete all as specified and as directed.
M & L cutting / cleaning away small trees, sapling, shrubs and uprooting roots from brick wall, chajjas including taking out complete root and making good surfaces in cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate or in cement mortar (1:4) to match the existing surface all as specified and as directed.
Material and labour for repair to overhang portion of chajja, facia, dropwall etc for continuous work by providing PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) and finished with CM (1:3) after taking down of damaged portion of RCC work by maintaining same level including all necessary formwork and finished the surface to match with the existing surface by providing same finish complete all as specified and directed. (Height of work to be considered upto 8.00 mtr from FFL of ground floor). (Note : Wherever reinforcement is required to be provided will be paid separately under relevant item and contractor have to inform the department one day in advance after binding of reinforcement for measurement otherwise no payment will be considered on this account).
M&L for seven stage cleaning and sterilization of inside the RCC/PVC water storage tank of capacity not exceeding 500 ltr of any description and in any position comprising following cleaning and sgterilization of water tanks through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/RERBAC-G-65/Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make : rays Cleantech/Indus watertech/satya enterprise. Location : SAA seven stages are as under plants :- (a) First staage is to drain out the water by using exit valve or high capacity dewatering system. (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/Inoxi-60/Nb-69 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks (c) Third stage is fresh water cleaning by high speed jet pump. (d) Fourth stage first bacteria screening is decrtification by using TERBAC-G5/Inohor-5/NB-10 a Govt Laboratory certified branded halogen compound. (e) Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified,branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69. Note : (i) Company will submit government laboratory test certificate of TERBAC-G5/inchor-5/nb-10,terbac-g65/inoxli-60/nb-69, befroe cleaning and name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning and sterilization staffs should be under accidental insurance coverage (ii) Outlet pipe of OHT to avoid entering scals and the same shall be reconnected after cleaning the oht and the quoted rate is deemed to include for the rovision (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tanks sterilization (iv) Contractor will be responsible for rectification of complaints occurred during cleaning the tanks ie. no water in tank/over flow due to broken of float valve/blockage and the cost of making good to be included in quoted rates.
M&L for seven stage cleaning and sterilization of inside the RCC/PVC water storage tank of capacity not exceeding 1000 ltr of any description and in any position comprising following cleaning and sgterilization of water tanks through bacteriological treatment by suing TERBAC g5/Inchor-5/NB-10/RERBAC-G-65/Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make : rays Cleantech/Indus watertech/satya enterprise. Location : SAA seven stages are as under plants :- (a) First staage is to drain out the water by using exit valve or high capacity dewatering system. (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/Inoxi-60/Nb-69 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks (c) Third stage is fresh water cleaning by high speed jet pump. (d) Fourth stage and first bacteria screening is decrtification by using TERBAC-G5/Inohor-5/NB-10 a Govt Laboratory certified branded halogen compound. (e) Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified,branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69. Note : (i) (i) Company will submit government laboratory test certificate of TERBAC-G5/inchor-5/nb-10,terbac-g65/inoxli-60/nb-69, befroe cleaning and name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning and sterilization staffs should be under accidental insurance coverage (ii) Outlet pipe of OHT to avoid entering scals and the same shall be reconnected after cleaning the oht and the quoted rate is deemed to include for the rovision (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tanks sterilization (iv) Contractor will be responsible for rectification of complaints occurred during cleaning the tanks ie. no water in tank/over flow due to broken of float valve/blockage and the cost of making good to be included in quoted rates.
Material, T&P and labour for cleaning of sewage line of any dia/bore using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed.
Material, T&P and labour for cleaning of manholes using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed.
Material, T&P and labour for cleaning of blockage of WC, wash basin, floor trap, nahani trap, gully trap (GT), kitchen, bath etc. (carrying soil waste) in any length upto the first manhole using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and removing night soil/ silted sludge/ waste material outside MD land unprohibited by any authority and following the statutory law/ guidelines complete all as specified and as directed.
Material, T&P and labour for cleaning/ desludging of septic tank/ soak well of any capacity and size users using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land complete all as specified and as directed.
M & L for cleaning/de-silting of loose mud, rubbish etc from drain bed including uprooting of vegetative growth throughly and wire brushing including flushing with water so as to achieve smooth flow of water in drain of bed width up to 60 cm and any depth etc complete all as directed by Engineer in charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position below or above ground floors, not exceeding 15 cm in depth complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound.
Cutting into existing manholes for connecting new drains of pipe of nominal size 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes of size 150 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
M & L for concrete bed to drain pipes of internal diameter 150 mm, in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
M&L for HDPE double wall corrugated (DWC) high density polythene pipes cut to length/size as per site requirement having corrugation on the outer wall and plain surface on the inner wall confirming to IS : 16098 (Part I & II) 2013 and stiffness class-8 laid in trenches for sewage line with and incl all fitting as required at site for internal dia 150mm complete all as specified and as directed.
S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge.
S & F PVC-U, type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge.
S & F PVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F PVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F UPVC vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F UPVC branch piece, Wye (45⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply and fix in repairs PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exceeding 400 sqm, depth of pot hole exceeding 50 mm but not exceeding 100 mm including rolling over the broken surfaces using 8 to 10 tonnes power roller to required camber and gradient complete all as specified and as directed.
M & L for 7.5 cm thick (compacted thickness) WBM, with coarse aggregates of granite, trap or basalt of grading 2 (63 to 45 mm size) or of grading 3 (53 to 22.4 mm size), spread, rolled and compacted to required gradient and camber with three wheel-power roller of 80 to 100 kN capacity or an equivalent vibratory roller complete all as specified and as directed.
Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
M & L for applying evenly a priming coat with bituminous primer (paving grade bitumen VG-10 grade) @ 10 kg per 10 sq metres complete all as specified & as directed.
M & L for applying evenly a tack coat with bituminous primer (paving grade bitumen VG-10 grade) @ 5 kg per 10 sq metres complete all as specified & as directed.
M & L for bituminous concrete 40 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5.5% by weight of total mix & hydraulic lime/cement(OPC-43 Grade) filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate on MINUS side variation in quantity of bitumen if any shall be priced at the rate of ₹55 per kg. No claim whatsoever shall be made for adjustment in plus side.
Repair to potholes any depth, exe 30 mm and not exceeding 1 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc., cutting around edges to at least 25 mm in depth, making good by applying tack coat at the rate of 05 kg per 10 Sqm, putting in bituminous macadam well rammed and sealed with bitumen 9.8 kg per 10 sqm blinded with 0.09 cum stone chippings, 6.3 mm size and rolled and compacted with power roller 8 to 10 tonnes to required camber and gradient complete all as specified and as directed.
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and as directed.
S&F cat eye solar reflective type of metal body alloy of size 100x100x20mm with PAMA striplens reflector fixed with and including MS stud of suitable size as per manufacturer instructions complete all as specified and directed by the Engr-in-charge.
S & F solar road studs of size not less than 125X 125 X 25 mm made of weather resistance aluminium alloy and poly carbonate material electronically welded micro- prismatic lens with abrasion resistant coating as approved by the Engineer in charge. The cats eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM E: 809 as recommended in BS: 873 part 4 :1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. The solar panel shall be high efficiency mono crystalline 2.5 V/60 m A and the battery shall be one Ni-mh type (1.2 V/1200 m Ah) high temp for backup of 36 hours full charging. The flash frequency shall be 60 ± 5 times per minute. Make- Model no 111 JUGNU of Dark Eye or equivalent makes as given in Appx B
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
M & L for 7.5 cm thick (compacted thickness) granular sub base GSB with coarse aggregates of kankar or laterite of grading 2 (63 to 45 mm size) or of grading 3 (53 to 22.4 mm size), spread, rolled and compacted to required gradient and camber with an equivalent vibratory roller complete all as specified and as directed.
PEE BEE INDIA
M/S AJOY DUTTA CHOWDHURY & CO
M/S DHAR AND DHAR
M/S GOPAL ROY AND CO
SUBHAS CONSTRUCTIONS
A K DUTTA CHOWDHURY AND CO
NIHAR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .